• 제목/요약/키워드: Fluorescence.

검색결과 4,397건 처리시간 0.027초

Effect of Ganglioside $G_{M3}$ on the Erythrocyte Glucose Transporter (GLUT1): Conformational Changes Measured by Steady-State and Time-Resolved Fluorescence Spectroscopy

  • Yoon, Hae-Jung;Lee, Min-Yung;Jhon, GiI-Ja
    • BMB Reports
    • /
    • 제30권4호
    • /
    • pp.240-245
    • /
    • 1997
  • Interactions between ganglioside $G_{M3}$ and glucose transporter, GLUT1 were studied by measuring the effect of $G_{M3}$ on steady-state and time-resolved fluorescence of purified GLUT1 in synthetic lipids and on the 3-O-methylglucose uptake by human erythrocytes. The intrinsic tryptophan fluorescence showed a GLUT 1 emission maximum of 335 nm, and increased in the presence of $G_{M3}$ by 12% without shifting the emission maximum, The fluorescence lifetimes of intrinsic tryptophan on GLUT1 consisted of a long component of 7.8 ns and a short component of 2,3 ns and $G_{M3}$ increased both lifetime components. Lifetime components were quenched by acrylamide and KI. Acrylarnide-mduced quenching of long-lifetime components was partly recovered by $G_{M3}$ However. KI-induccd quenching of short- and long-lifetime components was not rescued by $G_{M3}$. The anisotropy of 1.6-diphenyl-1.3.5-hexatriene (DPH)-probed dimyristoylphosphatidylcholine (DMPC) model membrane was also increased with $G_{M3}$ incorporation, The transport rate of 3-O-methylglucose increased by 20% with $G_{M3}$ incorporation on the erythrocytes, Therefore, $G_{M3}$ altered the environment of lipid membrane and induced the conformational change of GLUT1.

  • PDF

유기용매 중에서 Chlorophyll-a의 흡광 및 형광 (제1보) (The Absorbance and Fluorescence of Chlorophyll-a in Organic Solution (I))

  • 이중화;김병수;강정희;박면용
    • 대한화학회지
    • /
    • 제26권4호
    • /
    • pp.218-223
    • /
    • 1982
  • chl-a는 $5.12{\times}10-6M$ 이상의 농도와 건조된 ethyl ether, benzene, iso-octane중에 소중합체로 존재하고 이 용매에 n-prOH를 소량씩 가할때 단위체로 변함을 확인하였다. 형광은 중합체인 경우에 세게 나타나지만 중합정도에 따라 변하며 단위체인 경우는 약하게 나타났다. 그리고 n-prOH를 용매에 가할 때 흡광과 형광의 ${\lambda}_{max}$은 모두 장파장쪽으로 이동하였다. soret/red band의 비는 흡광도가 감소할수록 작아졌으며 chl-a의 농도에 따른 흡광도는 $1.0{\times}10^{-6}$M 정도의 용액에서 최대값을 나타냈다.

  • PDF

Quinine Assay with Home-Built UV-LED Fluorometer: Quantitative Analysis, Photo-Bleaching, Fluorescence Quenching, and Urine Analysis

  • Cheon, Tae-Min;Cheong, Byeong-Seo;Cho, Han-Gook;Kim, Jin-Hee;Kim, Kyoug-Soo
    • 대한화학회지
    • /
    • 제56권5호
    • /
    • pp.577-582
    • /
    • 2012
  • Quinine quantitative analysis, photo-bleaching, fluorescence quenching, and urine analysis have been performed by means of a UV-LED fluorometer, which can be easily built and used in a high-school laboratory. The quinine detection range is estimated to be 0.05-80 ppm, enough for many classroom luminescence experiments. The quinine content in commercial tonic water is determined from the calibration curve, and UV photo-bleaching of this anti-malarial drug is demonstrated with clear wavelength dependence. Halide quenching of quinine fluorescence is also observed and the increase in quenching efficiency in the order of $Cl^-$, $Br^-$, and $I^-$ is evident. Urine analyses for the student volunteers have been carried out and the results clearly reveal excretion of the ingested quinine. The student participants are exuberant throughout the course of this study and sense the practices resourceful.

LOC 형광검출 소자를 위한 광 다이오드의 제작 및 특성 평가 (Development of Photo-diode for LOC fluorescence detector)

  • 김주환;신경식;김용국;김상식;주병권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.100-103
    • /
    • 2003
  • Signal detection technologies such as fluorescence, charge and electrochemical detection used in the monolithic capillary electrophoresis system to convert the biochemical reaction into the electrical signal. The fluorescence detection using photodiodes that measure fluorescence emitted from eluting molecules is widely used for the monolithic capillary electrophoresis system. In this paper, in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. The p-i-n diode has higher sensitivity than photodiode. Considering these results, we fabricated p-i-n diodes on the high resistive$(4k{\Omega}{\cdot}cm)$ wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of p-i-n diode can be decreased by the application of finger pattern has parallel resistance structure from $571{\Omega}$ to $393{\Omega}$.

  • PDF

다중형광영상 연구를 위한 영상기반 시스템 개발 (Development of Image-based System for Multiple Fluorescence Imaging Study)

  • 윤웅배;김홍래;이현민;김영재;김광기;유헌;이승훈
    • 한국멀티미디어학회논문지
    • /
    • 제18권12호
    • /
    • pp.1445-1452
    • /
    • 2015
  • In these days, fluorescent materials such as ICG or 5-ALA is used for the brain surgery. The patients who underwent brain tumor surgery has been increased during last 30 years and the survivorship rate increased 22∼33% in 5 years. Recently, the Fluorescence induction surgery is developed for more safety and improved the resection rate for the glioma in the neurosurgery field. In this study, we proposed fluorescence area detection method for ICG and 5-ALA fluorescence induced surgery using acquired images from image processing. Accuracy was 99.21% from ICG images, and 99.51% from 5-ALA images. Matthews correlation coefficient was 88.67% from ICG images, and 90.49% from 5-ALA images.

Development Behavior of Vaporizing Sprays from a High-Pressure Swirl Injector Using Exciplex Fluorescence Method

  • Choi, Dong-Seok;Kim, Duck-Jool;Hwang, Soon-Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제14권10호
    • /
    • pp.1143-1150
    • /
    • 2000
  • The effects of ambient conditions on vaporizing sprays from a high-pressure swirl injector were investigated by an exciplex fluorescence method. Dopants used were 2% fluorobenzene and 9% DEMA (diethyl-methyl-amine) in 89% solution of hexane by volume. In order to examine the behavior of liquid and vapor phases inside of vaporizing sprays, ambient temperatures and pressures similar to engine atmospheres were set. It was found that the ambient pressure had a significant effect on the axial growth of spray, while ambient temperature had a great influence on the radial growth. The spatial distribution of vapor phase at temperatures above 473K became wider than that of liquid phase after half of injection duration. From the analysis of the area ratio for each phase, the middle part (region II) in the divided region was the region which liquid and vapor phases intersect. For liquid phase, fluorescence-intensity ratio was greatly changed at lms after the start of injection. However, the ratio of vapor phase was nearly uniform in each divided region throughout the injection.

  • PDF

Green Fluorescent Protein(GFP)의 Fluorescence-Activated Cell Sorter(FACS) 분석을 통한 유전자 이입의 최적화 (Optimization of Gene Transfection Using Fluorescence-Activated Cell Sorter(FACS) Analysis of Green Fluorescent Protein(GFP))

  • 김태경;박민태;이균민
    • KSBB Journal
    • /
    • 제14권3호
    • /
    • pp.377-379
    • /
    • 1999
  • CHO/dhfr- 세포에 대해 LipofectAmine$^{TM}$을 이용한 유전자 이입 효율을 증가시키기 위하여 지질과 DNA의 최적 농도를 구하였다. Reporter 유전자로서 GFP 유전자를 이용하였으며, 여러 농도의 지질 DNA로 유전자 이입된 각 세포군에서 나타나는 green fluorescence intensity를 FACS 분석함으로써 유전자 이입 효율을 정량화 할 수 있었다. 그 결과 24-well plate에서 $2.0{\mu}L$LipofectAmine$^{TM}$$0.4{\mu}g$ DNA를 조합하여 사용했을 때 최적의 유전자 이입 효율이 나타남을 알 수 있었다. 또한, GFP는 유전자 이입 최적화를 수행하는 데에 여러가지 면에서 유용한 수단이 될 수 있음을 확인할 수 있었다.

  • PDF

고속 트립토판 자가형광 이미징을 위한 시공간적 집중 기반의 라인 스캐닝 이광자 현미경 개발 (Development of line-scanning two-photon microscopy based on spatial and temporal focusing for tryptophan based auto fluorescence imaging)

  • 이준호;남효석;김기현
    • 한국가시화정보학회지
    • /
    • 제11권2호
    • /
    • pp.41-45
    • /
    • 2013
  • Two-photon microscopy (TPM) is minimally-invasive 3D fluorescence microscopy based on nonlinear excitation, and TPM can visualize cellular structures based on auto-fluorescence. Line-scanning TPM is one of high-speed TPM methods without sacrificing the image resolution by using spatial and temporal focusing. In this paper, we developed line-scanning TPM based on spatial and temporal focusing for auto-fluorescence imaging by exciting the tryptophan. Laser source for this system was an optical parametric oscillator (OPO) and it made near 570 nm femtosecond pulse laser. It had 200fs pulse width and 1.72 nm bandwidth, so that the achievable depth resolution was 2.41um and field of view (FOV) is 10.8um. From the characterization, our system has 3.0 um depth resolution and 12.3 um FOV. We visualized fixed leukocyte cell sample and compared with point scanning system.

형광물질을 이용한 대기 중 오존 Passive Sampler의 개발 (Development of a Passive Sampler using a Fluorescence Material for the Ambient Ozone)

  • 임봉빈;정의석;김선태
    • 한국대기환경학회지
    • /
    • 제20권4호
    • /
    • pp.483-491
    • /
    • 2004
  • The purpose of this study is to develop an ozone passive sampler and to evaluate its performance p-Acetamidophenol using as the reagent for ozone reacts specifically with the ambient ozone to produce a fluorescence material (p-acetamidopheonl dimer). The volume of absorbent solution and the extraction time determined at suitable conditions for measuring ozone were 100$\mu$L and 60 min, respectively. The changes of fluorescence were observed with incresing the storage period of passive samplers in ambient air. but the cool storage in a refrigerator did not remarkably influence the increase of fluorescence. The measurement for the precision oi the passive sampling was carried out with duplicate measurement of passive samplers. The intra-class correlation coefficients of passive samplers using dry and wet filters were 0.992 and 0.962, respectively The results from field validation tests indicated practical agreement (dry filter: r=0.963, wet filter: r=0.995) between the passive sampler and an UV photometric $O_3$ analyzer. The limit of quantification of ozone passive samplers with sampling time of 8 hr (wet filter) and 24 hr (dry filter) were 8.0 ppb and 2.7 ppb, respectively.

Fluorescence Quenching Causes Systematic Dye Bias in Microarray Experiments Using Cyanine Dye

  • Jeon, Ho-Sang;Choi, Sang-Dun
    • Genomics & Informatics
    • /
    • 제5권3호
    • /
    • pp.113-117
    • /
    • 2007
  • The development of microarray technology has facilitated the understanding of gene expression profiles. Despite its convenience, the cause of dye-bias that confounds data interpretation in dual-color DNA microarray experiments is not well known. In order to economize time and money, it is necessary to identify the cause of dye bias, since designing dye-swaps to reduce the dye-specific bias tends to be very expensive. Hence, we sought to determine the reliable cause of systematic dye bias after treating murine macrophage RAW 264.7 cells with 2-keto-3-deoxyoctonate (KDO), interferon-beta $(IFN-{\beta})$, and 8-bromoadenosine (8-BR). To find the cause of systematic dye bias from the point of view of fluorescence quenching, we examined the correlation between systematic dye bias and the proportion of each nucleotide in mRNA and oligonucleotide probe sequence. Cy3-dye bias was highly correlated with the proportion of adenines. Our results support the fact that systematic dye bias is affected by fluorescence quenching of each feature. In addition, we also found that the strength of fluorescence quenching is based on not only dye-dye interactions but also dye-nucleotide interactions as well.