• Title/Summary/Keyword: Fluorescence polarization immunoassay

Search Result 13, Processing Time 0.025 seconds

QUANTITATION OF BARBITURATES IN URINE BY GC/MS AND ITS COMPARISON TO FLUORESCENCE POLARIZATION IMMUNOASSAY

  • Choo, Hea-Young;Park, Jeongeun;Park, Myung-Ja
    • Toxicological Research
    • /
    • v.7 no.1
    • /
    • pp.29-35
    • /
    • 1991
  • Barbiturates are commonly abused tranquilizer and a rapid method to determine these drugs in biological samples is needed. In this study, was screened barbiturates in urine specimens by the fluorescence polarization immunoassay method(FPIA) and the positive samples were confirmed and identified by the more definitive GC/MS method. Fifteen positive smples which have barbiturate values higher than 0.5 ng/ml were analyzed by the GC/MS method. Eight samples were identified as phenobarbital and five samples were identified as crotilbarbitone.

  • PDF

SCREENING OF BENZODIAZEPINES IN URINE BY THE IMMUNOASSAY AND QUANTITATION BY GC-NPD METHOD

  • Park, Jongsei;Park, Jeongeum;Park, Myung-Ja
    • Toxicological Research
    • /
    • v.7 no.1
    • /
    • pp.21-27
    • /
    • 1991
  • We developed a simple method to determine benzodiazepines in biological samples using electron capature detectors and nitrogen-phosphorous detectors. The extraction of 13 benezodiazepines in urine at pH 9.5 with toluene and its analysis in GC/NPD showed the peaks in 9-16 min. In this retention time range, the biological backaground was fairly low and the drugs could be identified in low concentrations. The benzodiazepines in urine samples were screened by the fluorescence polarization immunoassay and positive samples were confirmed by the GC/NPD method.

  • PDF

Application of Fluorescence Polarization Immunoassay for the Screening of Ochratoxin A in Unpolished Rice (현미에서의 오크라톡신 A의 검색을 위한 형광편광면역분석법의 응용)

  • Park, Jung-Hyun;Chung, Duck-Hwa;Lee, In-Seon
    • Journal of Life Science
    • /
    • v.16 no.6
    • /
    • pp.1006-1013
    • /
    • 2006
  • To High Throughput Screening (HTS), a homogeneous fluorescence polarization immunoassay (FPIA) was developed for the quantitative determination of ochratoxin A(OTA) using a $Victor^3$ (PerkinElmer). The homologous tracer, fluorescein-labelled OTA-EDF were synthesized and a specific OTA antibody has been used in the development of the method. It allowed the determination of OTA in the concentration range 0.5-200 ng/ml, with the detection limit of 0.3 ng/ml. The method developed was highly specific and reproducible. OTA spikes in unpolished rice extracts were determinable by FPIA with good recovery. For naturally contaminated unpolished rice samples some disagreement was observed between the results obtained by FPIA and HPLC, which could be related to the a little matrix effect observed for FPIA. Further research is needed to validate the procedure. On the basis of these initial results, this FPIA appears to meet the performance criteria for OTA screening of food samples without a complicated clean-up.

Diagnostic Accuracy of the Quidel Sofia Rapid Influenza Fluorescent Immunoassay in Patients with Influenza-like Illness: A Systematic Review and Meta-analysis

  • Lee, Jonghoo;Song, Jae-Uk;Kim, Yee Hyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.3
    • /
    • pp.226-236
    • /
    • 2021
  • Background: Although the Quidel Sofia rapid influenza fluorescent immunoassay (FIA) is widely used to identify influenza A and B, the diagnostic accuracy of this test remains unclear. Thus, the objective of this study was to determine the diagnostic performance of this test compared to reverse transcriptase-polymerase chain reaction. Methods: A systematic literature search was performed using MEDLINE, EMBASE, and the Cochrane Central Register. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and a hierarchical summary receiver-operating characteristic curve (HSROC) of this test for identifying influenza A and B were determined using meta-analysis. A sensitivity subgroup analysis was performed to identify potential sources of heterogeneity within selected studies. Results: We identified 17 studies involving 8,334 patients. Pooled sensitivity, specificity, and DOR of the Quidel Sofia rapid influenza FIA for identifying influenza A were 0.78 (95% confidence interval [CI], 0.71-0.83), 0.99 (95% CI, 0.98-0.99), and 251.26 (95% CI, 139.39-452.89), respectively. Pooled sensitivity, specificity, and DOR of this test for identifying influenza B were 0.72 (95% CI, 0.60-0.82), 0.98 (95% CI, 0.96-0.99), and 140.20 (95% CI, 55.92-351.54), respectively. The area under the HSROC for this test for identifying influenza A was similar to that for identifying influenza B. Age was considered a probable source of heterogeneity. Conclusion: Pooled sensitivities of the Quidel Sofia rapid influenza FIA for identifying influenza A and B did not quite meet the target level (≥80%). Thus, caution is needed when interpreting data of this study due to substantial betweenstudy heterogeneity.

The Effect of Cephalosporins on the Stability of Gentamicin and Tobramycin in Human Serum (세파로스포린계 약물이 겐타마이신, 토브라마이신의 혈청중 안정성에 미치는 영향)

  • Kim, In Wha;Lee, Suk Hyang;Shin, Hyun Taek;Kim, Myung Min;Choi, Kyung Eob
    • Korean Journal of Clinical Pharmacy
    • /
    • v.6 no.2
    • /
    • pp.28-31
    • /
    • 1996
  • The in vitro inactivation of gentamicin and tobramycin by four cephalosporins (cefotetan, cefuroxime, cefodizime, cefotiam) in human serum was investigated. Each cephalosporin was added to human serum samples containing gentamicin sulfate or tobramycin sulfate. Blank samples containing only aminoglycosides were used as controls. Samples were stored at -20, 4 and $25^{\circ}C$ and were analyzed for aminoglycoside concentrations by fluorescence polarization immunoassay ($TDxFLx^{TM}$ system) at 0, 2, 4, 8, 12, 24, 48 and 72 hours after mixing. The serum containing cefotiam stored at $25^{\circ}C$ showed significant inactivation of gentamicin by $12\%$ at 72 hours. The results indicate that cefotitan, cefuroxime and cefodizime do not inactivate gentamicin and tobramycin while cefotiam inactivates gentamicin.

  • PDF

The Influence of Assay Error Weight on Gentamicin Pharmacokinetics Using the Bayesian and Nonlinear Least Square Regression Analysis in Appendicitis Patients

  • Jin, Pil-Burm
    • Archives of Pharmacal Research
    • /
    • v.28 no.5
    • /
    • pp.598-603
    • /
    • 2005
  • The purpose of this study was to determine the influence of weight with gentamicin assay error on the Bayesian and nonlinear least squares regression analysis in 12 Korean appen dicitis patients. Gentamicin was administered intravenously over 0.5 h every 8 h. Three specimens were collected at 48 h after the first dose from all patients at the following times, just before regularly scheduled infusion, at 0.5 h and 2 h after the end of 0.5 h infusion. Serum gentamicin levels were analyzed by fluorescence polarization immunoassay technique with TDxFLx. The standard deviation (SD) of the assay over its working range had been determined at the serum gentamicin concentrations of 0, 2, 4, 8, 12, and 16 ${\mu}g$/mL in quadruplicate. The polynominal equation of gentamicin assay error was found to be SD (${\mu}g$/mL) = 0.0246-(0.0495C)+ (0.00203C$^2$). There were differences in the influence of weight with gentamicin assay error on pharmacokinetic parameters of gentamicin using the nonlinear least squares regression analysis but there were no differences on the Bayesian analysis. This polynominal equation can be used to improve the precision of fitting of pharmacokinetic models to optimize the process of model simulation both for population and for individualized pharmacokinetic models. The result would be improved dosage regimens and better, safer care of patients receiving gentamicin.

Assay Error for Improved Pharmacokinetic Modeling and Simulation of Vancomycin (반코마이신의 약물동태학적 모델링과 시뮬레이션의 향상을 위한 분석오차)

  • Burm, Jin Pil
    • YAKHAK HOEJI
    • /
    • v.57 no.1
    • /
    • pp.32-36
    • /
    • 2013
  • The purpose of this study was to determine the influence of assay error for improved pharmacokinetic modeling and simulation of vancomycin on the Bayesian and nonlinear least squares regression analysis in 24 Korean gastric cancer patients. Vancomycin 1.0 g was administered intravenously over 1 hr every 12 hr. Three specimens were collected at 72 hr after the first dose from all patients at the following times, at 0.5 hr before regularly scheduled infusion, at 0.5 hr and 2 hr after the end of 1 hr infusion. Serum vancomycin levels were analyzed by fluorescence polarization immunoassay technique with TDX-FLX. The standard deviation (SD) of the assay over its working range had been determined at the serum vancomycin concentrations of 0, 20, 40, 60, 80 and $120{\mu}g/ml$ in quadruplicate. The polynomial equation of vancomycin assay error was found to be SD $({\mu}g/ml)=0.0224+0.0540C+0.00173C^2$ ($R^2=0.935$). There were differences in the influence of weight with vancomycin assay error on pharmacokinetic parameters of vancomycin using the nonlinear least squares regression analysis but there were no differences on the Bayesian analysis. This polynomial equation can be used to improve the precision of fitting of pharmacokinetic models to optimize the process of model simulation both for population and for individualized pharmacokinetic models. The result suggests the improvement of dosage regimens for the better and safer care of patients receiving vancomycin.

Pharmacokinetics of Two Cyclosporine Formulations Using FPIA and HPLC Assay in Volunterrs

  • Kwon, Kwang-Il;Kim, Moo-Heon;Park, Jong-Woo;Lee, Chang-Hyun
    • Archives of Pharmacal Research
    • /
    • v.18 no.6
    • /
    • pp.385-390
    • /
    • 1995
  • The analytical methods for the analysis of cyclosporine (CsA), a fluorescence polarization immunoassay (FPIA) and HPLC method, were compared in a pharmacokinetic study of two CsA soft capsule formultaions ($Sandimmun^{\circledR}$; Sandoz, $Implanta^{\circledR}$; Hanmi). Sixteen healthy volunteers completed the study and each subjected single doses ($4{\tiems}100$ mg) of the test and the reference formulations in a two-way crossover design with a one-week drug-free interval between doses. Following each administration, whole blood concentrations of CsA were monitored over a period of 24 hour by both FPIA and HPLC methods. Blood concentrations nad pharmacokinetic parameters determined by either analytical method showed large intersubject variation, with the FPIA data showing relatively higher magnitude of intersubjecte variation than the HPLC data. The blood concentrations determined by FPIA were 1.1-1.3 times higher than those determined by HPLC. There were strong and significant correlations between the two methods (r>0.83 : p<0.0001). Intersubuject variation for the $AUC_{inf}{\;}and{\;}AUC_{24hr}$ of the test formulation was slightly reduced without statistical significance (paried -t test : p>0.05 $t_{max}$ was earlier nad $C_{max}$ was slightly lower for the test formulation, $AUC_{24h}, {\;}C_{max}, {\;}T_{max}$ and MRT determined separately from the data obtained by the two methods for the two formulations were examined by analyses of variance (ANOVA) for the bioequivalency evaluation. Results of ANOVA and confidence limits of terst/reference ratios of $AUC_{24th}$, $C_{max}$, $t_{max}$ and MRT, and statistical tests indicated the bioequivalence of the two formulations (i.e., test/reference ratio was within $100{\times}20%$) except for $C_{max}$ and $t_{max}$. The mean of tmax also showed 11.1% and 9.3% differences but the detection limit were 29.2% and 29.6% as determined by FPIA and HPLC resepctively. This experiments suggest that the data yielded for the two formulations demonstrated that they were bioequivalent.

  • PDF