• Title/Summary/Keyword: Fluorescence method

Search Result 1,017, Processing Time 0.027 seconds

Extended Injectant Mole-Fraction Imaging of Supersonic Mixing using Acetone PLIF

  • Takahashi, Hidemi;Ikegami, Shuzo;Hirota, Mitsutomo;Masuya, Goro
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.781-789
    • /
    • 2008
  • The fluorescence ratio method for processing planar laser induced fluorescence(PLIF) data was generalized for quantitative imaging of the injectant mole-fraction in supersonic mixing flowfields. The original fluorescence ratio approach was introduced by Hartfield et al. for tests in a special closed-loop wind tunnel to eliminate the effects of thermodynamic property variations in compressible flowfields and to provide a quantitative means of mole-fraction measurement. However, they implicitly assumed that the tracer molecules were seeded at the same fraction in both main and secondary flows. In the present study, we proposed generalizing the Hartfield method by considering differences in the tracer seeding rates. We examined the generalized method in a mixing flowfield formed by sonic transverse injection into a Mach 1.8 supersonic air stream. The injectant molefraction distribution obtained from PLIF data processed by our new approach showed better agreement with the gas chromatograph than one based on the Hartfield method.

  • PDF

Fluorescece Microscope using Total Internal Reflection for Measuring Biochip (내부 전반사 방식에 의한 바이오칩 측정 장비)

  • Bae, Soo-Jin;Kang, Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1694-1698
    • /
    • 2007
  • This study suggests a new fluorescence microscope to observe micro-samples within fluorophore in a variety of biomedical fields including the fluorescence analysis of a biochip, such as a DNA micro-array. A fluorescence microscope is a device for irradiating light onto a micro-object, executing an excitation and fluorescence emission process. In this study, it adopts a total internal reflection fluorescence(TIRF) method to excite a whole micro-sample substrate different from an existing way which uses an evanescent wave resulting from a total internal reflection on the micro-sample surface. Suggested TIRF microscope can reduce optical noise and obtain images with higher sensitivity thus obtain precise information about the density, quantity, location, etc. of a flurophore, and can simultaneously process separate images even when plurality of fluorophores having different excitation and fluorescent wavelength ranges is distributed, thus easily obtain information about the fluorophores.

An Experimental Investigation of Air Fuel Ratio Measurement using Laser Induced Acetone Fluorescence (아세톤 형광을 이용한 공연비 측정 기법 연구)

  • Park Seungjae;Huh Hwanil;Oh Seungmook
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.353-356
    • /
    • 2002
  • Planar laser induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Preliminary investigation was performed to measure quantitative air excess ratio distribution in an engine fueled with LPG. It is known that fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone was excited by KrF excimer laser (248nm) and its fluorescence image was acquired by ICCD camera with a cut-of filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile was suggested. Raw images were divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which was taken by a calibration process, were converted to air excess ratio distribution. This investigation showed instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

  • PDF

Fluorescence Characterization of LaRC PETI-5, BMI, and LaRC PETI-5/BMI Blends

  • Cho, Donghwan;Yang, Gyeongmo
    • Fibers and Polymers
    • /
    • v.3 no.2
    • /
    • pp.60-67
    • /
    • 2002
  • In the present study, the fluorescence behavior ova phenylethynyl-terminated imide (LaRC PETI-5) resin, a bismaleimide (BMI) resin, and various LaRC PETI-5/BMI blends with different blend compositions has been characterized as a function of heat-treatment temperature, using a steady-state fluorescence technique with a front-face illumination method far solid-state films. It is observed that there are distinguishable changes in the spectral shape, size, and position of fluorescence with varying heat-treatment temperature in the pure and blend samples. The result is qualitatively explained in terms of charge transfer complex formation as well as microenvironmental change with local mobility and viscosity occurring in the LaRC PETI-5, BMI, and their blends during the cure process. The result also implies that a steady-state fluorescence technique may be a useful tool to understand the processing conditions of polyimides and their blends in the film form on the basis of their thermo-photophysical responses.

Development of Photo-sensor for Integrated Lab-On-a-Chip (집적화된 Lab-On-a Chip을 위한 광센서의 제작 및 특성 평가)

  • 김주환;신경식;김용국;김태송;김상식;주병권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.4
    • /
    • pp.404-409
    • /
    • 2004
  • We fabricated photo-sensor for fluorescence detection in LOC. LOC is high throughput screening system. Our LOC screens biochemical reaction of protein using the immunoassay, and converts biochemical reaction into electrical signal using LIF(Laser Induced Fluorescence) detection method. Protein is labeled with rhodamine intercalating dye and finger PIN photodiode is used as photo-sensor We measured fluorescence emission of rhodamine dye and analyzed tendency of fluorescence detection, according to photo-sensor size, light intensity, and rhodamine concentration. Detection current was almost linearly proportional to two parameters, intensity and concentration, and was inversely proportional to photo-sensor size. Integrated LOC consists of optical-filter deposited photo-sensor and PDMS microchannel detected 50 (pg/${mu}ell$) rhodamine. For integrated LOC including light source, we used green LED as the light source and measured emitted fluorescence.

Fluorescence Immunoassy of HDL and LDL Using Protein A LB Film

  • Choi, Jeong-Woo;Park, Jun-Hyo;Lee, Woo-Chang;Oh, Byung-Keun;Min, Jun-Hong;Lee, Won-Hong
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.6
    • /
    • pp.979-985
    • /
    • 2001
  • A fluorometric detection technique for HDL (High Density Lipoprotein) and LDL (Low Density Lipoprotein) was developed for application in a fiber-optic immunosensor using a protein A Langmuir-Blodgget (LB) film. For the fluorescence immunoassay, antibodies specific to HDL or LDL were imobilied on the protein A LB film, and a fluorescence amplification method was developed to overcome their weak fluorescence. The deposition of protein A using the LB technique was monitored using a surface pressure-are $({\pi}-A)$ curve, and the antibody immobilization of the protein A LB film was experimentally verified. The immobilized antibody was used to separate only HDL and LDL from a sample, then the fluorescence of he separated HDL or LDL was amplified. The amount of LDL or HDL was measured using the developed fiber optic fluorescence detection system. The optical properties resulting from the reaction of HDL or LDL with o-phtaldialdehyde, detection range, response time, and stability of the immunoassay were all investigated. The respective detection ranges for HDL and LDL were sufficient to diagnose the risk of coronary heart disease. The amplification step increased the sensitivity, while selective separation using the immobilized antibody led to linearity in the sensor signal. The regeneration of the antibody-immobilized substrate could produce a stable and reproducible immunosensor.

  • PDF

Trace Analysis of Uranium in Aqueous Samples by Laser-induced Fluorescence Spectroscopy (레이저를 이용한 용액중의 미량 우라늄 분석)

  • Jung, Kwang-Woo;Kim, Jeong-Moog;Kim, Cheol-Jung;Lee, Jong-Min
    • Nuclear Engineering and Technology
    • /
    • v.19 no.4
    • /
    • pp.242-248
    • /
    • 1987
  • A sensitive, direct method for the determination of trace amounts of uranium in solution has been developed utilizing laser-induced fluorescence spectroscopy and a fluorescence enhancing reagent 'Fluran.' Standard addition technique is incorporated into the analysis to eliminate sample matrix effects. Analytical data show that a detection limit of 0.1 ppb (part per billion) uranium has been achieved and the precision of the analysis is in the range of 5% relative standard deviation. Results using the laser fluorescence method on many sets of unknown samples have been compared against corresponding values determined by other methods.

  • PDF

CdTe Quantum Dots as Fluorescent Probes for Josamycin Determination

  • Peng, Jinyun;Nong, Keliang;Mu, Guangshan;Huang, Fengying
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2727-2731
    • /
    • 2011
  • A new method for the determination of josamycin has been developed based on quenching of the fluorescence of 3-mercaptopropionic acid-capped CdTe quantum dots (MPA-CdTe QDs) by josamycin in ethanol. Reaction time, interfering substances on the fluorescence quenching, and mechanism of the interaction of CdTe QDs with josamycin were investigated. Under optimum conditions, the relative fluorescence intensity was linearly proportional to the concentration of josamycin between 12.0 and 120.0 ${\mu}g\;mL^{-1}$ with a correlation coefficient of 0.9956 and a detection limit of 2.5 ${\mu}g\;mL^{-1}$. The proposed method was successfully applied to commercial tablets, and the results were satisfactory, i.e. consistent with those of high-performance liquid chromatography (HPLC).

Distribution of the Concentration of Fuel Vapor in DI Gasoline Sprays Under Evaporation Condition (증발 조건에서 직분식 가솔린 분무의 증기 농도의 분포)

  • Hwang, S.C.;Choi, D.S.;Cha, K.J.;Kim, D.J.
    • Journal of ILASS-Korea
    • /
    • v.4 no.4
    • /
    • pp.1-8
    • /
    • 1999
  • The concentration and spatial distribution of vapor phases in DI (Direct Injection) gasoline spray were measured quantitatively by exciplex fluorescence method. Fluorobenzene and DEMA (diethylmethylamine) in a solution of hexane were used as the exciplex-forming dopants. The fluorescence intensity of vapor phase were obtained by ICCD camera with the appropriate filter The relationship between fluorescence intensity and vapor concentration was induced fer the purpose of a quantitative analysis. The 2-D vapor/liquid images of fuel spray were captured under the evaporation condition, and the spatial distribution of vapor concentration was obtained. The spatial distribution of liquid phase had hollow-cone shape. And the vapor phase was widely distributed in the whole spray. The behavior of vapor phase was significantly affected by second flow such as entrainment, vortex, while that of liquid phase was scarcely affected.

  • PDF

QUANTITATION OF BARBITURATES IN URINE BY GC/MS AND ITS COMPARISON TO FLUORESCENCE POLARIZATION IMMUNOASSAY

  • Choo, Hea-Young;Park, Jeongeun;Park, Myung-Ja
    • Toxicological Research
    • /
    • v.7 no.1
    • /
    • pp.29-35
    • /
    • 1991
  • Barbiturates are commonly abused tranquilizer and a rapid method to determine these drugs in biological samples is needed. In this study, was screened barbiturates in urine specimens by the fluorescence polarization immunoassay method(FPIA) and the positive samples were confirmed and identified by the more definitive GC/MS method. Fifteen positive smples which have barbiturate values higher than 0.5 ng/ml were analyzed by the GC/MS method. Eight samples were identified as phenobarbital and five samples were identified as crotilbarbitone.

  • PDF