• Title/Summary/Keyword: Fluidized reactor

Search Result 262, Processing Time 0.028 seconds

Characteristics of Co-Combustion of Korean Anthracite with Bituminous Coal in a Circulating Fluidized Bed (순환유동층에서 유.무연탄 혼소 특성)

  • Lee, J.M.;Kim, J.S.;Lee, E.M.
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.3
    • /
    • pp.1-9
    • /
    • 2005
  • The characteristics of co-combustion of Korean anthracite and bituminous coal was determined in a TGA and a lab-scale CFB reactor. The combustion reactivity of Korean anthracite (E = 51.2 kcal/mol) was much lower than that of bituminous coal (E = 14.5 kcal/mol). As the addition amount of the bituminous coal into the anthracite was increased, the reactivity of the anthracite was found to be improved. The effluent rate of the emission gases from the CFB reactor was not changed appreciably when each coal burned. As the bituminous coal was added, however, the effluent rate of the emissions was increased. The unburned carbon in fly ash from the CFB reactor was decreased with increasing the ratio of bituminous coal in co-combustion. But as the ratio of the bituminous coal was larger than 40 %, the combustion reactivity was not increased any more.

  • PDF

Retrospect on Refractories in Water Treatment (기존 정수처리방법으로 제거가 어려운 유기물에 대한 실험적 연구)

  • 우달식;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.17-23
    • /
    • 1995
  • As a basic experiment to develope biological pretreatment proces~ in water treatment, the experiments on biodegradability and isothermal adsorption of activated carbon were performed on refractories such as humic acid, $NH_3-N$, phenol and ABS which caused the problems in drinking water treatment. Also, the treatabilities on humic acid were examined in the continuous flow type reactors. The removal efficiencies of humic acid, $NH_3-N$, phenol and ABS in the biodegradable experiments for 5 days were 20.1%, 73.4%, 91.7% and 97.5%, respectively. In the isothermal adsorption test of refractories on activated carbon to be used as a media in the continuous flow type reactors, ABS and phenol are adsorbed easily, but humic acid and $NH_3-N$ are difficult to be done. The removal efficiencies of humic acid in granular activated carbon(GAC) reactor were about 7-8% higher than in biological activated carbon(BAC) reactor. The removal efficiencies of humic acid in biological fluidized bed(BFB) reactor were about 30% in GAC media, but were almost zero in sea sand media.

  • PDF

Removal of Ammonium-Nitrogen {$NH_4^+$ -N) Using Immobilized Nitrifier Consortium in PVA(PolyvinylalcohoI) (PVA에 고정화된 Nitrifier Consortium을 이용한 암모니아성 질소의 제거)

  • 서재관;서근학;김성구
    • KSBB Journal
    • /
    • v.14 no.1
    • /
    • pp.51-57
    • /
    • 1999
  • The immobilization of nitrifier consortium was carried out for the application to recirculating aquaculture system(RAS). The abilities of $NH_4^+$-N removal by immobilized nitrifier consortia prepared with boric acid treated, ethanol treated, ad freezing-thawing treated PVA beads at the concentration 15% were examined. To identify the possibility of applying the beads in the fluidized bed reactor, characteristics of beads were evaluated. The suitable bead was boric acid treated beads which had highest ammonia removal rate of 16.09 g/$m^3$/day. It took 12 days for nitrifier consortium immobilized beads to be stable for the removal of $NH_4^+$-N. Life spans of the beads were more than three months with aggressive aeration in the fluidized ed reactor when nitrifier consortia immobilized in PVA beads were used. In order to apply the nitrifier consortium immobilized beads to aquaculture facility, the continuous reactor was used for 49 days with synthetic aquacultural water containing 2 mg/L ammonia. The highest ammonia removal rate of 31.87 g/$m^3$/day was observed when hydraulic residence time was 0.6 hour(36min.).

  • PDF

Effects of Operating Variables on CO Conversion of WGS Catalyst in a Fluidized Bed Reactor Equipped with Bed Insert (내부 삽입물을 적용한 유동층 반응기에서 WGS 촉매의 CO 전화율에 미치는 조업변수들의 영향)

  • Park, Jihye;Lee, Dongho;Park, Youngeheol;Moon, Jongho;Rhee, Youngwoo;Ryu, Hojung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.2
    • /
    • pp.209-217
    • /
    • 2014
  • To enhance the performance of SEWGS system by holding the WGS catalyst in a SEWGS reactor, a spring type bed insert was developed. In this study, effects of operating variables such as steam/CO ratio, gas velocity, syngas concentration on CO conversion were investigated in a fluidized bed reactor using the spring type bed insert to hold the WGS catalyst as tablet shape. CO conversion increased initially as the steam/CO ratio increased. But further increment of the steam/CO ratio caused decreasing of CO conversion because of increment of gas velocity and decrement of syngas concentration. Moreover, CO conversion decreased as the gas velocity increased and the syngas concentration decreased at the same steam/CO ratio. Continuous operation up to 48 hours (2 days) was carried out to check reactivity decay of WGS catalyst supported by spring type bed insert. The average CO conversion was 99.04% and we could conclude that the WGS reactivity at those conditions was maintained up to 48 hours.

Effect of Bed Insert Geometry on CO Conversion of WGS Catalyst in a Fluidized Bed Reactor for SEWGS Process (SEWGS 공정을 위한 유동층 반응기에서 내부 삽입물의 모양이 WGS 촉매의 CO 전환율에 미치는 영향)

  • Ryu, Hojung;Kim, Hana;Lee, Dongho;Jin, Gyoungtae;Park, Youngcheol;Jo, Sungho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.6
    • /
    • pp.535-542
    • /
    • 2013
  • To enhance the performance of SEWGS system by holding the WGS catalyst in a SEWGS reactor using bed inserts, effect of bed insert geometry on CO conversion of WGS catalyst was measured and investigated. Small scale fluidized bed reactor was used as experimental apparatus and tablet shaped WGS catalyst and sand particle were used as bed materials. The cylinder type and the spring type bed inserts were used to hold the WGS catalysts. The CO conversion of WGS catalyst with the change of steam/CO ratio was determined based on the exit gas analysis. Moreover, gas flow direction was confirmed by bed pressure drop measurement for each case. The measured CO conversion using the bed inserts showed high value comparable to previous results even though at low catalyst content. Most of input gas flowed through the bed center side when we charged tablet type catalyst into the cylinder type bed insert and this can cause low $CO_2$ capture efficiency because the possibility of contact between input gas and $CO_2$ absorbent is low in this case. However, the spring type bed insert showed good reactivity and good distribution of gas, and therefore, the spring type bed insert was selected as the best bed insert for SEWGS process.

Steam Activated Carbon Preparation Using HTFBR from Biomass and its Adsorption Characteristics

  • Asirvatham, J. Herbert;Gargieya, Nikhar;Paradkar, Manali Sunil;Prakash Kumar, B.G.;Lima Rose, Miranda
    • Carbon letters
    • /
    • v.9 no.3
    • /
    • pp.203-209
    • /
    • 2008
  • The objective of this work is to study the feasibility of the preparation of the activated carbon (AC) from coconut tree flowers using high temperature fluidized bed reactor (HTFBR). The activating agent used in this work is steam. The reactor was operated at various activation temperature (650, 700, 750, 800 and $850^{\circ}C$) and activation time (30, 60, 120 and 240 min) for the production of AC from coconut tree flowers. Effect of activation time and activation temperature on the quality of the AC preparation was observed. Prepared AC was characterized in-terms of iodine number, methylene blue number, methyl violet number, ethylene glycol mono ethyl ether (EGME) surface area and SEM photographs. The best quality of AC from coconut tree flowers (CFC) was obtained at an activation temperature and time of $850^{\circ}C$ and 1 hr restectively. The effectiveness of carbon prepared from coconut tree flowers in adsorbing crystal violet from aqueous solution has been studied as a function of agitation time, carbon dosage, and pH. The adsorption of crystal violet onto AC followed second order kinetic model. Adsorption data were modeled using both Langmuir and Freundlich classical adsorption isotherms. The adsorption capacity $q_m$ was 277.78 mg/g., equilibrium time was found to be 180 min. This adsorbent from coconut tree flowers was found to be effective for the removal of CV dye.

Effects of Bed Insert Geometry and Shape of WGS Catalysts on CO Conversion in a Fluidized Bed Reactor for SEWGS Process (SEWGS 공정을 위한 유동층 반응기에서 내부 삽입물의 모양 및 WGS 촉매의 형상이 CO 전환율에 미치는 영향)

  • Ryu, Hojung;Kim, Hana;Lee, Dongho;Bae, Dalhee;Hwang, Taeksung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.2
    • /
    • pp.150-159
    • /
    • 2013
  • To enhance the performance of SEWGS system by holding the WGS catalyst in a SEWGS reactor using bed inserts, effects of insert geometry and shape of WGS catalysts on CO conversion were measured and investigated. Small scale fluidized bed reactor was used as experimental apparatus and WGS catalyst (particle and tablet) and sand were used as bed materials. The parallel wall type and cross type bed inserts were used to hold the WGS catalysts. The CO conversion with steam/CO ratio was determined based on the exit gas analysis. The measured CO conversion using the bed inserts showed high value comparable to physical mixing cases. Moreover, gas flow direction was confirmed by bed pressure drop measurement for each case. Most of input gas flowed through the catalyst side when we charged tablet type catalyst into the bed insert and this can cause low $CO_2$ capture efficiency because the possibility of contact between input gas and $CO_2$ absorbent is low in this case. New bed insert geometry was proposed based on the results from this study to enhance contact between input gas and WGS catalyst and $CO_2$ absorbent.

Hydrogen Generation Characteristics of SMART Process with Inherent $CO_2/H_2$ Separation (CO$_2/H_2$ 원천분리 SMART 공정의 수소생산특성)

  • Ryu, Ho-Jung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.55-58
    • /
    • 2007
  • To check the feasibility of SMART (Steam Methane Advanced Reforming Technology)system, an experimental investigation was conducted. A fluidized bed reactor of diameter 0.052 m was operated cyclically up to the $10^{th}$ cycle, alternating between reforming and regeneration conditions. FCR-4 catalyst was used as the reforming catalyst and calcined limestone (domestic, from Danyang) was used as the $CO_2$ absorbent. Hydrogen concentration of 98.2% on a dry basis was reached at $650^{\circ}C$ for the first cycle. This value is much higher than $H_2$ concentration of 73.6% in the reformer of conventional SMR (steam methane reforming) system. However, the hydrogen concentration decreased because the $CO_2$ capture capacity decreased as the number of cycles increased.

  • PDF

Combustion Characteristic of Paper Sludge Using TGA Reactor (열중량 반응기를 이용한 제지슬러지의 연소 특성)

  • Yook, Chan-Nam;Kim, Jung-Soo;Han, Kwang-Soo
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.48-58
    • /
    • 2003
  • To obtain the preliminary design data for combustion of paper sludges, decomposition characteristics and combustion kinetics of paper sludges reactor have been determined in a TGA reactor. Also, the combustion characteristics of paper sludges have been determined in a fluidized bed reactor. The data obtained from the TGA reactor indicate that dewatering of paper sludge is terminated at temperature below 130${\circ}$C. With heating rate of 20${\circ}$C/min, combustion is terminated at temperature below 340${\circ}$C .The combustion rate is found to be first order with respect to temperature and oxygen concentration. Activation energies for paper wastes are found to be 570, 700, 2600, 4600 Kcal/mole, respectively. The calcination conversions were investigated with the operating temperature and residence time. In this investigation, it was found that calcination conversion was affected by the operating temperature and residence time. The optimum conditions of operating temperature and mean residence time were 850${\circ}$C and 6 minutes of respectively.