• Title/Summary/Keyword: Fluid-bed

Search Result 219, Processing Time 0.022 seconds

Analysis on ventilation efficiency by CFD simulation for breathing zone in bed room (CFD해석에 의한 침실 호흡역의 환기효율 분석)

  • Yoo, Bok-Hee;Yoon, Chung-Sook
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.11-16
    • /
    • 2002
  • Indoor air environment is one of the most important factors that affect resident's health and comfort level. In this paper, the influence of ventilation efficiency with different types of furniture arrangement at breathing zone in a room was analyzed by numerical simulation based on computational fluid dynamics(CFD). The furniture layout of students' bedroom have been classified by three different patterns so that SVE3(scale for ventilation efficiency3) in the rooms was analyzed for air flow distribution. According to the results of the study, SVE3 has the maximum value in spaces between furnitures and each comer of the room. The furniture arrangement influences the ventilation efficiency. It was con finned that ventilation effective in a room is not uniformly distributed as compared the breathing zone with all the area in a room. It means that a study of ventilation efficiency was considered relatively with target zone(a residential or breathing zone) and all the area in a space.

Particle Attrition Characteristics in a Bubbling Fluidized Bed Under High Temperature and High Pressure Conditions (고온 고압 조건하의 기포유동층 반응기에서의 입자 마모특성)

  • Moon, Jong-Ho;Lee, Dong-Ho;Ryu, Ho-Jung;Park, Young Cheol;Lee, Jong-Seop;Min, Byoung-Moo;Jin, Gyoung Tae
    • Clean Technology
    • /
    • v.20 no.4
    • /
    • pp.359-366
    • /
    • 2014
  • Attrition characteristics of PKM1-SU particles, $CO_2$ absorbents for pre-combustion $CO_2$ capture process, and FCC particles, catalytic particles for hydro cracking of crude oil, were investigated at high temperature and high pressure conditions. Particle attrition tests were executed at various kinds of temperature ($0-400^{\circ}C$) and pressure (0-20 bar) conditions in a cylinder type bubbling fluidized bed with 15.1 cm diameter, 120 cm height and 1 mm orifice-sparger tube. Attrited particles before and after tests were analyzed by BET, optical microscopy, and particle size analyzer. Effects of bed material height (solid inventory) and steam injection were also verified by using ASTM D5757-95, conventional attrition test method.

A Feasibility Study on the Mixed Refrigerant Composition in the Rankine Cycle Empowered by Cold Energy (냉열을 이용한 랭킨 사이클 방식의 발전시스템에서 혼합냉매유체 조성비의 적용한계 분석)

  • Jeong, Moon;Cho, Eunbi;Hwang, Inju;Kang, Choonhyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.3
    • /
    • pp.14-18
    • /
    • 2016
  • The power generation system using cold energy, which evolves in a large amount during the vaporization process of the liquefied natural gas, was designed in favor of the Rankine cycle with a mixed refrigerant as the working fluid. In this study it is intended to identify the allowable limits of the working fluid composition in respect of equipment safety in the Rankine cycle-type power generation system driven by the cold energy. The thermodynamic properties of the working fluid, which is a hydrocarbon mixture, were calculated with the Peng-Robinson model. In the steady state simulation of the power generation system by using a commercial tool Aspen HYSYS, the feed conditions of LNG Test Bed Train No.1 along with some necessary assumptions were incorporated. The results indicated that deterioration of the mechanical performance of the equipment as well as its safety would be brought about if contents of $C_2H_6$ and $C_3H_8$ in the mixture become, respectively, too high or too low.

Seismic control of offshore platform using artificial neural network (인공신경망을 이용한 해양구조물의 지진시 진동제어)

  • Kim, Dong Hyawn;Kim, Ju Myung;Shim, Jae Seol
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.2
    • /
    • pp.175-181
    • /
    • 2009
  • An intelligent control technique using a neural network is proposed for offshore structures exposed to sea-bed earthquakes. Fluid-structure interaction effect was considered in developing controller and a training algorithm for the neural network is presented. In the numerical example, the performance of the proposed neural network controller was compared with that of a passive controller and uncontrolled structures. Based on the example, it can be concluded that the proposed neuro-control scheme can be used for offshore structures with nonlinear characteristics due to its interaction with fluid.

Optimal Measuring Point Selection Method of Indoor Temperature using CFD Analysis (CFD 해석을 이용한 실내 온도 최적 측정 위치 선정 방법)

  • Lee, Min-Goo;Jung, Kyung-Kwon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.7
    • /
    • pp.1559-1566
    • /
    • 2012
  • This paper proposed the method to find out the optimal sensing point of temperature in test-bed with the sensor of temperature, such as real residence. We selected optimal locations by checking temperature change which was simulated by the means of CFD (Computational Fluid Dynamics) and the variation of air flow. We made 3-dimensional model of the testbed using DesignBuilder software, and ran the CFD. We selected the optimum temperature measurement location of 1.5 m height from the floor and low temperature variation. The experiments were conducted 30 temperature and humidity sensors in real place. After that, we confirmed the results of temperature change.

Effect of Curing and Compression Process on the Drug Release of Coated Ion-Exchange Resin Complexes

  • Jeong, Seong-Hoon;Wang, Hun-Sik;Koo, Ja-Seong;Choi, Eun-Joo;Park, Ki-Nam
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.2
    • /
    • pp.67-73
    • /
    • 2011
  • Ion exchange resins can be one of the good carriers for sustained drug release. However, the sustained release may not be enough only with themselves and hence film coating with rate controlling polymers can be applied to have a further effect on the drug release. Due to the environmental and economic issues of organic solvent for the polymer coating, aqueous polymeric systems were selected to develop dosage forms. Among the many aqueous polymeric dispersions for the film coating, EC (ethylcellulose) based polymers such as Aquacoat$^{(R)}$ ECD and Surelease$^{(R)}$ were evaluated.A fluid-bed coating was applied as a processing method. The drug release rate was quite dependent on the coating level so the release rate could be modified easily by changing different levels of the coating. The drug release rate in the Aquacoat$^{(R)}$ coated resin particles was strongly dependent on curing, which is a thermal treatment to make homogeneous films and circumvent drug release changes during storage. After dissolution test using the compressed tablets in which the coated resin particles are contained, inhomogeneous coating and even pores could be observed showing that the mechanical properties of EC were not resistant to granulation and compaction process. However, when tablets were prepared in different batches, the release profiles were almost identical showing the feasibility of the coated resin particle as incorporated into the tablet formulation.

A Numerical Study on Coughed Particle Dispersion and Deposition in Negative Pressure Isolation Room according to Particle Size (음압격리병실에서의 기침 토출입자의 입경에 따른 확산 및 침적에 대한 수치해석 연구)

  • Jung, Minji;Hong, Jin Kwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.2
    • /
    • pp.37-44
    • /
    • 2018
  • Purpose: This study investigates the influences of coughing direction and healthcare worker's location on the transport characteristics of coughed particles in airborne infection isolation room (AIIR), which is commonly called negative pressure isolation room, with a downward ventilation system. Methods: Computational Fluid Dynamics (CFD) was used to simulate the airflow and for tracing the behavior of particles. Results: The results show that the airflow pattern and coughing direction have a significant influence on the characteristics of particle dispersion and deposition. When healthcare workers are in the isolation room with the patient who is lying on the bed, it is recommended to be located far from the anteroom to reduce the exposures from infectious particles. And when the patient is lying, it is more effective in removing particles than when the patient is in Fowler's position. Although it is an isolation room that produces unidirectional flow, coughing particles can spread to the whole room and a large number of particles can be deposited onto patient, bed, side rails, healthcare worker, ceiling, floor, and sidewall. Implications: Following the patients' discharge or transfer, terminal cleaning of the vacated room, furniture, and all clinical equipment is essential. Also, it is necessary to establish detailed standard operating procedure (SOP) in order to reduce the risk of cross-contamination.

Preparation and Dissolution Characteristics of Sustained Release Granules Containing Indapamide (인다파마이드가 함유된 서방형 과립의 제조 및 용출 특성)

  • Park, Ji-Seon;Seo, Hui;Kim, Byung-Jin;Jeong, Sang-Young;Shin, Byung-Cheol;Yuk, Sun-Hong;Hwang, Sung-Joo;Cho, Sun-Hang
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.2
    • /
    • pp.105-110
    • /
    • 2008
  • Indapamide (4-chloro-N-(2-methyl-1-indolinyl)-3-sulfamoyl-benz-amide) is an oral antihypertensive diuretic agent indicated for the treatment of hypertensive. The diuretic and natriuretic effects are mainly due to the structure of o-chlorobenzenesulfonamide. The objective of this study was to formulate sustained release indapamide granules and assess their formulation variables. Granules were prepared by fluid bed coating method and consist of drug layer and membrane layer. The granules were coated with HPC and ethyl cellulose along with plasticizer dibuthyl sebacate. The release of indapamide depended on the type of Eudragit such as RS and NE 30 D used in the formulation controlled release layer. These results obtained clearly suggest that the sustained release oral delivery system for indapamide could be designed with satisfying drug release profile approved.

Analysis of the factors influencing headache and backache following lumbar puncture (요추 천자 후 발생하는 두통 및 요통에 영향을 주는 요인의 분석)

  • Lee, Sang Taek;Chung, Sochung;Park, Yong Mean;Bae, Sun Hwan;Yu, Jeong Jin;Lee, Ran
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.8
    • /
    • pp.856-860
    • /
    • 2008
  • Purpose : This study aimed to examine the factors influencing the appearance of headache and backache following diagnostic lumbar puncture in children, focusing on the need for strict bed rest after lumbar puncture. Methods : We studied 70 two-fifteen-year-old pediatric patients who underwent diagnostic lumbar puncture from July 2005 to July 2007 at Konkuk University Hospital. We divided them into two groups. Patients in the first group (n=24) were allowed free mobility and patients in the second group (n=46) were to have strict bed rest for four hours after puncture. Data were analyzed by age, sex, number of puncture attempts, cell counts and pressure in the cerebrospinal fluid (CSF), duration of bed rest, and occurrence of headache and backache. Results : The rate of complications was not significantly related to sex, age, presence of enterovirus, CSF pressure, or postural headache. The occurrence of headache was significantly correlated with white blood cell (WBC) count in CSF (P=0.043). Symptom frequency did not differ significantly between the groups. Backache was significantly related to the frequency of puncture attempts (P=0.046). Conclusion : Strict bed rest following diagnostic lumbar puncture in children does not influence headaches and backaches. These are respectively related to the WBC count on the CSF profile and the frequency of attempts. Therefore, after lumbar puncture, absolute bed rest is not necessary and patients are more comfortable with free mobility.

Abducens Nerve Palsy after Lumbar Spinal Fusion Surgery with Inadvertent Dural Tearing

  • Cho, Dae-Chul;Jung, Eul-Soo;Chi, Yong-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.581-583
    • /
    • 2009
  • Abducens nerve palsy associated with spinal surgery is extremely rare. We report an extremely rare case of abducens nerve palsy after lumbar spinal fusion surgery with inadvertent dural tearing, which resolved spontaneously and completely. A 61-year-old previous healthy man presented with chronic lower back pain of 6 weeks duration and 2 weeks history of bilateral leg pain. He was diagnosed as having isthmic spondylolisthesis at L4-5 and L5-S1, and posterior lumbar interbody fusion was conducted on L4-5 and L5-S1. During the operation, inadvertent dural tearing occurred, which was repaired with a watertight dural closure. The patient recovered uneventfully from general anesthesia and his visual analogue pain scores decreased from 9 pre-op to 3 immediately after his operation. However, on day 2 he developed headache and nausea, which were severe when he was upright, but alleviated when supine. This led us to consider the possibility of cerebrospinal fluid leakage, and thus, he was restricted to bed. After an interval of bed rest, the severe headache disappeared, but four days after surgery he experienced diplopia during right gaze, which was caused by right-side palsy of the abducens nerve. Under conservative treatment, the diplopia gradually disappeared and was completely resolved at 5 weeks post-op.