• Title/Summary/Keyword: Fluid-bed

Search Result 219, Processing Time 0.025 seconds

Three Cases of Tetracyclines Induced Esophageal Ulcer (Tetracyclines이 원인으로 생각되는 약제성 식도궤양 3례)

  • Lee, Heon-Ju;Chung, Moon-Kwan;Kim, Chong-Suhl
    • Journal of Yeungnam Medical Science
    • /
    • v.1 no.1
    • /
    • pp.179-183
    • /
    • 1984
  • In recent years, an increasing number of drugs have been reported to cause direct esophageal damage. More than 30 cases on tetracyclines induced esophageal ulcer have been reported since the first description of tetracycline induced esophageal ulcer by Bokey and Hugh in 1975. In Korea, only one case of doxycycline-induced esophageal ulcer has been reported. Authors have experienced 3 cases of esophageal ulcer probably caused by tetracyclines. The patients had taken their capsules just before going to bed with little fluid intake. About 6-8 hours later they had felt substernal burning sensation and epigastric discomfort. Gastrofiberscopy revealed relatively well demarcated circular ulcers on the mid esophagus. An esophagogram showed no apparent abnormality. Patients's symptomas became negligible with antacid treatment within 2-5 days. One of the causes of the esophageal ulcer is thought to be the delay in transit time of drugs and direct esophageal damage from mucosal contact when tablets are ingested in the recumbent position without an accompanying proper quantity of fluid. If only physicians endow patients with more concern about drug induced esophageal ulcer, they could find out more increasing number of drug induced esophageal ulcers by gastroscopic examination and thereby could prevent tetracycline induced esophageal ulcer.

  • PDF

A Study on the Method for Measuring the live Calorific Value of LNG in storage tank using LNG Densitometer (LNG 밀도계를 이용한 저장 탱크 내 LNG 발열량 실시간 측정방법에 관한 연구)

  • Ha, Young-Cheol;Lee, Seong-Min
    • Korean Chemical Engineering Research
    • /
    • v.49 no.1
    • /
    • pp.35-40
    • /
    • 2011
  • The low caloric LNG, which didn't meet the gas interchangeability of Korea, has been imported from 2005 winter season. Amount of this LNG imports has been increased from year to year. In the near future, very low caloric LNG (calorific value ${\leq}$ 9,500 kcal/$Nm^3$) such as CBM, Shale LNG will be imported large amounts. For this reason, we need a method for monitoring live calorific values(CV) of LNG in each storage tank to supply gasified LNG with interchangeable CV at LNG receiving terminal. This study was conducted to develope the method for measuring the live CVs of LNG in each storage tank using LNG densitometer. For this purpose, the accurate correlation between CV and density of LNG was derived and the uncertainty of this method was evaluated and also the measuring system for CVs was constructed at LNG receiving terminal. To verify this method, the results of measurement using this method were compared with the field data of LNG analysis and the results showed that the deviations were 0.17~0.47%.

A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume) (방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구)

  • An, Yang-ki;Kim, Jee-young;Kim, Kum-hee;Jang, Hee-soo;Jung, Jung-pil;Choi, Jong-woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.

Hand Hygiene Compliance among Visitors at a Long-term Care Hospital in Korea: A Covert Observation Study

  • Jung, Min Young;Kang, JaHyun
    • Research in Community and Public Health Nursing
    • /
    • v.30 no.1
    • /
    • pp.99-107
    • /
    • 2019
  • Purpose: This study aimed to assess hand hygiene (HH) compliance among visitors at a long-term care hospital in South Korea. Methods: The study was conducted at a 502-bed long-term care hospital located in Gyeonggi-do Province. From July 1 to August 15, 2017, including more than 6 weekends and one holiday, a trained observer covertly assessed visitors' HH at all five units (360 beds in total) of the study hospital building until the completion of 1,000 HH opportunities (i.e., 200 opportunities per unit). The modified World Health Organization (WHO) HH observation form was used. Instead of professional categories and the "before clean/aseptic procedure" moment, the estimated age range for each visitor were recorded in four categories: children (<14 years old), adolescents (14~18), adults (19~64), and the elderly (${\geq}65$). The collected data were analyzed using SPSS 22.0. Results: A total of 1,000 HH opportunities were observed from 766 visitors (an average of 1.31 per visitor) and the overall HH compliance rate was 20.3%. Overall, 53.7% of the HH cases were performed with soap and water. Among the 4 HH moments, the "after body fluid exposure risk" moment showed the highest compliance rate (83.5%); 93.9% used soap and water. The most commonly exposed potential body fluid among visitors was saliva (48.1%). Conclusion: For hospital visitors in long-term care hospitals, HH education programs including HH moments need to be developed and implemented. Further studies are necessary to evaluate visitors' HH compliance in various hospital settings and find the related variables influencing visitors' HH.

A Study on CFD of Turbo fan and Fabrication of Turbo Fan with Honeycombs by PBF (터보 팬의 유동해석 및 허니콤 구조가 적용된 터보 팬의 PBF 3D 프린팅 제작에 관한 연구)

  • Jin, Chul-Kyu;Lee, Haesoo;Lee, Un-Gil;Woo, Jae-Hyeog
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.899-908
    • /
    • 2022
  • In this study, a study was conducted to localize a large aluminum turbo fan used for tank powerpack. The turbo fan was scanned with a 3D scanner and then 3D modeling was performed. Computational fluid dynamics (CFD) were performed from the performance conditions of the fan, and structural analysis was performed using the pressure data obtained from CFD. The fan was reduced to 1/5 size by applying the geometric similarity. A 1/5 size fan has a honeycomb structure inserted into the front shroud and back shroud to reduce the weight by 5.3%. A 1/5 size fan was printed using a PBF 3D printer, and a 1/5 size fan with honeycombs was also printed. The pressure drop of 8.67 kPa and the required power of 138.19 kW, which satisfies the performance conditions of the fan, were confirmed from the results of CFD. The values of the maximum deformation amount of 0.000788 mm and the maximum effective stress of 0.241 MPa were confirmed from the structural analysis results. The fan printed by the PBF 3D printer had the same shape as the modeling, and the shape was perfect. There are no defects anywhere in appearance. However, the condition of the outer surface of the fan's back shroud is rough compared to other locations. The fan in which the honeycomb was inserted was also perfectly output, and the shape of the honeycomb was the same as the modeling.

FBR CFD Simulation of Steam Methanol Reforming Reaction using Intrinsic Kinetic Data of Copper-impregnated Hydrotalcite Catalyst (구리가 함침된 하이드로탈사이트 촉매의 고유 키네틱 데이터를 이용한 메탄올 수증기 개질반응의 고정층 반응기 CFD 시뮬레이션)

  • Jae-hyeok Lee;Dongil Shin;Ho-Geun Ahn
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.78-85
    • /
    • 2023
  • Fixed-bed reactor Computational Fluid Dynamics (CFD) simulation of methanol steam reforming reaction was performed using the intrinsic kinetic data of the copper-impregnated hydrotalcite catalyst. The activation energy of the copper hydrotalcite catalyst obtained from the previous study results was 97.4 kJ/mol, and the pre-exponential was 5.904 × 1010. Process simulation was performed using the calculated values and showed a similar tendency to the experimental results. And the conversion rate according to the change of the reaction temperature (200 - 450 ℃) and the molar ratio of methanol and water was observed using the intrinsic kinetic data. In addition, mass and heat transfer phenomena analysis of a commercial reactor (I.D. 0.05 - 0.1m, Length 1m) was predicted through axial 2D Symmetry simulation using the power law model of the above kinetic constants.

On Reasonable Boundary Condition for Inclined Seabed/Structure in Case of the Numerical Model with Quadrilateral Mesh System (사각격자체계 수치모델에서의 경사면 처리기법에 관하여)

  • Hur, Dong-Soo;Lee, Woo-Dong;Bae, Ki-Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.591-594
    • /
    • 2008
  • Present study aims at the development of a reasonable boundary condition for a structure over inclined seabed in case of the numerical model with quadrilateral mesh system. The technique for the inclined impermeable/permeable boundary in the quadrilateral mesh is newly proposed. The new technique and LES-WASS-3D model (Hur and Lee, 2007) have been used for the investigation of the dynamics of fluid field, and validated through the comparison with a typical stair-type boundary condition. 3-Dimensional numerical model with Large Eddy Simulation is called LES-WASS-3D, and is able to simulate directly interaction of WAve Structure Sea bed/Sandy beach.

A Survey on Prehospital Emergency Medical Service for the Improvement of Acute Coronary Syndrome Assessments - Focus on the Jecheon.Danyans Area - (급성관상동맥증후군 환자의 병원 전 119구급의료서비스 실태 및 개선방안 -충북 제천.단양을 중심으로-)

  • Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.293-299
    • /
    • 2008
  • From January, 2004 to July, 2007, 97 patients were diagnosed with Acute coronary syndrome(ACS) in Emergency Medical Center in Jecheon City in Korea. Among 97 patients, the prehospital assessment rates were as follows ; blood pressure check(27.80%, pulse rate check(33.0%), respiration check(23.7%). In hospital emergency care, oxygen supply was 52.6%, absolute bed rest was 12.4%, electrocardiogram(EKG) check was 4.1%, and nitroglycerin and intravenous fluid therapy was 0%. Therefore, ACS patients have not received sufficient prehospital cares till now. In order to improve the proficiency of the first aid emergency medical technicians(EMTs), it is necessary to provide the continuing On-the-job training(OJT) programs for prehospital emergency care.

Dynamic Analysis of Guyline in the Offshore Guyed Towers Considering Sea Bed Contact Conditions (심해용 Guyed Tower 계류선의 해저면과의 접촉조건을 고려한 동적 해석)

  • 이명우;박우선;박영석
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.3 no.4
    • /
    • pp.244-254
    • /
    • 1991
  • The numerical analysis on tile behaviour of mooring system in the offshore guyed tower is presented. The governing equilibrium equations are derived by the principle of virtual work. The drag and inertia effects of fluid are included in a Morrison type equation. The finite element method is used in the computation. Geometric nonlinearities for the analysis of the mooring line are considered in which both modified Newton-Raphson method and Newmark-$\beta$ method are employed. Numerical experiments show the validity and the capability of the developed mathematical formulation.

  • PDF

Direct Open Venous Drainage: An Alternative Choice for Flap Congestion Salvage

  • Park, Su Han;Choi, Woo Young;Son, Kyung Min;Cheon, Ji Seon;Yang, Jeong Yeol
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.3
    • /
    • pp.143-146
    • /
    • 2015
  • In this report, we present a scalp defect reconstruction with lateral arm free flap. We highlight the difficulty in obtaining a recipient vein and the venous drainage managed through an open end of the donor vein. A 52-year-old woman presented with a pressure sore on the left scalp. A lateral arm free flap was transferred to cover this $8{\times}6cm$ defect. The arterial anastomosis was successful, but no recipient vein could be identified within the wound bed. Instead, we used a donor venous end for the direct open venous drainage. In order to keep this exposed venous end patent, we applied heparin-soaked gauze dressing to the wound. Also, the vein end was mechanically dilated and irrigated with heparin solution at two hour intervals. Along with fluid management and blood transfusion, this management was continued for the five days after the operation. The flap survived well without any complication. Through this case, we were able to demonstrate that venous congestion can be avoided by drainage of the venous blood through an open vessel without the use of leeches.