• 제목/요약/키워드: Fluid resistance

검색결과 624건 처리시간 0.026초

고강도콘크리트의 고속펌핑을 위한 압송성평가 및 예측모델에 관한 연구 (Development of Evaluation and Prediction Model for Concrete High Speed Pumping)

  • 김형래;조호규;정웅택
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.201-203
    • /
    • 2012
  • The establishment of the technology for evaluating friction resistance and pipe pressure and the relation of the fluid characteristics and pumpability of concrete is essential for the evaluation of concrete pumping performance for high speed construction of super-tall building. So, this study focuses on quantitative evaluation of concrete fluid characteristics and surface friction resistance under the change of concrete mix proportion and pumping condition. In this study, we measured the rheology of concrete and pipe pressure and surface friction characteristics when pumping. And, relations between the rheology characteristics of concrete and pumping performance was investigated by experiment. As the result of the experiment, high regression between the surface friction and pressure gradient was confirmed. And, prediction model to evaluate the friction resistance coefficient and pipe pressure reduction coefficient was suggested.

  • PDF

Effect of Free Surface Based on Submergence Depth of Underwater Vehicle

  • Youn, Taek-Geun;Kim, Min-Jae;Kim, Moon-Chan;Kang, Jin-Gu
    • 한국해양공학회지
    • /
    • 제36권2호
    • /
    • pp.83-90
    • /
    • 2022
  • This paper presents the minimum submergence depth of an underwater vehicle that can remove the effect of free surface on the resistance of the underwater vehicle. The total resistance of the underwater vehicle in fully submerged modes comprises only viscous pressure and friction resistances, and no wave resistance should be present, based on the free surface effect. In a model test performed in this study, the resistance is measured in the range of 2 to 10 kn (1.03-5.14 m/s) under depth conditions of 850 mm (2.6D) and 1250 mm (3.8D), respectively, and the residual resistance coefficients are compared. Subsequently, resistance analysis is performed via computational fluid dynamics (CFD) simulation to investigate the free surface effect based on various submergence depths. First, the numerical analysis results in the absence of free surface conditions and the model test results are compared to show the tendency of the resistance coefficients and the reliability of the CFD simulation results. Subsequently, numerical analysis results of submergence depth presented in a reference paper are compared with the model test results. These two sets of results confirm that the resistance increased due to the free surface effect as the high speed and depth approach the free surface. Therefore, to identify a fully submerged depth that is not affected by the free surface effect, case studies for various depths are conducted via numerical analysis, and a correlation for the fully submerged depth based on the Froude number of an underwater vehicle is derived.

원통형 다전극식 정전용량-전기전도도 센서를 이용한 연료전지 차량용 냉각수의 유전특성 평가 (Evaluation about Dielectric Property of Heat Transfer Fluids for Fuel Cell Vehicle using Cylindrical Multi-Terminal Capacitive-Conductive Sensor)

  • 김재훈;김주한;김윤형;최강월;한상옥;용기중
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1087-1094
    • /
    • 2010
  • We have developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid. It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Also to assess diagnosis characteristics of heat transfer fluid, i.e. coolant, we have performed accelerated aging test using developed sensor attached to cooling system. Consequently, it was measured dielectric and electric resistance of coolant to estimate and analyse for dielectric properties by degradation condition.

EMP 방호시설의 덕트 및 배관 최적 설계 방안 (Design Optimization for Air Ducts and Fluid Pipes at Electromagnetic Pulse(EMP) Shield in Highly Secured Facilities)

  • 방승기;김재훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권4호
    • /
    • pp.15-24
    • /
    • 2014
  • This study conducted a computational fluid dynamics(CFD) analysis to find an appropriate diameter or sectional area of air ducts and fluid pipes which have an electromagnetic pulse(EMP) shied to protect indoor electronic devices in special buildings like military fortifications. The result shows that the optimized outdoor air intake size can be defined with either the ratio of the maximum air velocity in the supply duct to the air intake size, or the shape ratio of indoor supply diffuser to the outdoor air intake. In the case of water channel, the fluid velocity at EMP shield with the identical size of the pipe, decreases by 25% in average due to the resistance of the shield. The enlargement of diameter at the shield, 2 step, improves the fluid flow. It illustrated that the diameter of downstream pipe size is 1step larger than the upstream for providing the design flow rate. The shield increases friction and resistance, in the case of oil pipe, so the average flow velocity at the middle of the shield increase by 50% in average. In consideration of the fluid viscosity, the oil pipe should be enlarged 4 or 5 step from the typical design configuration. Therefore, the fluid channel size for air, water, and oil, should be reconsidered by the engineering approach when EMP shield is placed in the middle of channel.

진공청소기용 팬-모터 어셈블리의 시스템-레벨 분석 (System-level Analysis of a Fan-motor Assembly for Vacuum Cleaner)

  • 박창환;박경현;장경식
    • 한국유체기계학회 논문집
    • /
    • 제20권1호
    • /
    • pp.5-14
    • /
    • 2017
  • A fan-motor assembly in a vacuum cleaner is analyzed through system-level analysis method. This system consisted of three components, a fan, motor, and the flow resistance of the motor, or of the vacuum cleaner. System-level analysis method is characterized by the combination of torque matching at a constant throttling condition between the fan and the motor and the pressure drop at a constant flow rate due to the flow resistance of the motor, or of the vacuum cleaner. The performance characteristics of the fan-motor assembly and the vacuum cleaner system could be predicted over the whole range of operation, based on the characteristics of each component. The predicted performance of the vacuum cleaner system through system-level analysis agreed well with the experimental results within 4.5% difference of pressure and 6% difference of the efficiency. The effect of flow resistance of a motor is investigated and it is found that the efficiency decrease of fan-motor assembly at the constant flow rate due to the flow resistance of a motor is determined by the flow resistance ratio(FRR), which is defined as a ratio of flow resistance of motor and the flow resistance of a constant throttling condition of a given point. The fan-motor assembly(S2 model) was modified to reduce the FRR from 9.0% to 2.4% and the experimental result shows that the efficiency of S2 model was improved by about 3% at best efficiency point.

Numerical Study on the Extrapolation Method for Predicting the Full-scale Resistance of a Ship with an Air Lubrication System

  • Kim, Dong-Young;Ha, Ji-Yeon;Paik, Kwang-Jun
    • 한국해양공학회지
    • /
    • 제34권6호
    • /
    • pp.387-393
    • /
    • 2020
  • Frictional resistance comprises more than 60% of the total resistance for most merchant ships. Active and passive devices have been used to reduce frictional resistance, but the most effective and practical device is an air lubrication system. Such systems have been applied in several ships, and their effects have been verified in sea trials. On the other hand, there are some differences between the results predicted in model tests and those measured in sea trials. In this study, numerical analyses were carried out for a model and a full-scale ship. A new extrapolation method was proposed to improve the estimation of the full-scale resistance of a ship with an air lubrication system. The volume of fluid (VOF) method was considered for the numerical models of the air layer. The numerical method was validated by comparing the experimental data on the air layer pattern and the total resistance.

니켈-크롬 합금 보철물 주위 치은 열구내에서 발견된 니켈 내성 균주에 관한 분자생물학적 연구 (A STUDY OF NI-RESISTANT BACTERIA ISOLATED FROM GINGIVAL CREVICULAR FLUID ON THE PATIENTS WEARING NI-CR ALLOY PROSTHESIS (IN TERMS OF MOLECULAR BIOLOGICAL ASPECTS))

  • 채영아;우이형;이성복
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.207-222
    • /
    • 2003
  • As a material of metal-ceramic prosthesis, nickel as a form of Ni-Cr alloy has been used for many dental prostheses in many cases. However, several problems in use of the alloy have been revealed (ex ; tissue stimulation, skin allergy, hypersensitivity cytotoxicity and carcinogenecity). Little is known about nickel with respect to the relationship between Ni-prosthesis and gaining of Niresistance in oral microorganisms. The present study was undertaken to check whether use of Ni-prosthesis leads to occurrence of Ni-resistant microorganisms. So this study may suggest the possible relationships between the oral microorganisms and nickel-resistance in oral environment. Bacteria were isolated from the gingival crevicular fluid on the patients wearing Ni-Cr prosthesis. The isolated bacteria were tested fir their Ni-resistance in nickel containing media at different concentration from 3mM to 110mM. E. coli HB101 was used as control. The Ni-resistant bacteria were isolated and biochemically identified. The Ni-resistant bacteria were tested several biochemical, molecular-biological tests. Performed tests were : measuring the growth curve, antibiotic test, growth ability test in liquid media, isolation of the chromosome and plasmid, digestion of DNA by restriction enzyme, electrophoresis of chromosome and plasmid DNA, identification of Ni-resistant genes by the DNA hybridization. The results were as follows 1) The bacteria isolated from gingival crevicular fluid on the patients wearing Ni-Cr alloy prosthesis showed nickel-resistance. 2) The isolated microorganisms grew at nickel containing media of high concentrations (60mM-110mM). 3) Based on the biochemical tests, the isolated microorganisms were identified as Enterococcus faecalis(13 cases), Klebsiella pneumoniae(1 case) and Enterobacter gergoviae(1 case). 4) Enterococcus faecalis expressed not only nickel resistance but also the multi-drug resistance to several antibiotics ; chloramphenicol, kanamicin, streptomycin, lincomycin, clindamycin, However, all strain showed the sensitivity against the tetracycline. 5) DNA hybridization result suggests that there is no homology between the previously known gene of nickel resistance in Klebsiella pneumoniae and chromosomal DNA of Enterococcus faecalis.

원자력 발전소 격납 건물의 수위 측정을 위한 열식 레벨 측정기 개발 (Development of Thermal Type Fluid Level Transmitter for Water Level Measurement of Containment Building in Nuclear Power Plant)

  • 윤준용;성낙원;이철호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.404-410
    • /
    • 2001
  • A new thermal type fluid level transmitter was designed and tested at the HITROL R&D institute. The relation of heat transfer and electric resistance was adopted as an operation principle. The length of a fabricated level transmitter was two meters and a water under normal temperature was used as a working fluid for the experiment Finally, the new product could have a high precision, acceptable accuracy and reasonable response time. Foreign-made level transmitter of this type is under in use for measuring water level of containment building in nuclear power plants so far. It is expected that new product will substitute it.

  • PDF

전단농화유체가 함침된 Kevlar 직물의 방검 및 방침 특성 (Puncture and Cutting Resistance Characteristics of Shear Thickening Fluid Impregnated Kevlar Fabrics)

  • 이복원;김일진;이연관;김천곤;윤병일;백종규
    • Composites Research
    • /
    • 제21권5호
    • /
    • pp.23-30
    • /
    • 2008
  • 칼이나 송곳 같이 날카로운 날이 있거나 같이 뽀족한 도구를 사용한 위협을 군인 뿐 아니라 경찰이나 경호원들에게 쉽게 일어날 수 있다. 이러한 위협으로부터 보호하기 위한 방호복의 소재의 적용하기 위해 방탄소재로 사용되는 Kevlar 직물을 사용하였으며 방검 및 방침 특성 향상을 위해 나노입자가 충진된 전단농화유체(Shear thickening fluid)를 함침하였다. National Institute of Justice 시험 격에 따라 송곳과 칼을 제작하여 낙하충격시험기를 사용한 방검 및 방침특성 평가시험을 수행하였다. 전단농화유체는 각각 100nm, 300nm, 500nm 기의 구형 나노 $SiO_2$ 입자를 충진시켜 제작하였으며 전단농화유체의 함침과 나노 입자의 크기가 갖는 방검 및 방침 특성에 대한 영향력을 평가하였다. STF를 함침한 Kevlar 직물은 송곳을 사용한 낙하충격시험에서는 미처리 직물에 비해 좀 더 높은 충격하중을 지지하며 견고히 송곳의 침투에 저항하는 우수한 방침 특성을 보여준 반면 칼을 사용한 방검시험에서는 효과를 보여주지 못하였다. 특히 전단농화유체를 구성하는 나노입자의 크기는 방침 특성을 결정하는 주요한 인자임을 확인하였다.

양수의 대장균에 대한 세균증식 억제효과 (Bacterial Growth-inhibiting Activity of Amniotic Fluid Against E. coli)

  • 김수용;최명식;장우현;차창룡
    • 대한미생물학회지
    • /
    • 제22권3호
    • /
    • pp.233-240
    • /
    • 1987
  • The amniotic fluid provides a medium in which the fetus can readily move, cushions him against possible injury and helps him maintain an even temperature. Besides above mentioned functions, investigators reported that human amniotic fluid contains host-resistance factors which prevent bacteria from producing infectious disease and this activity shows difference among human racial groups or bacterial genera, species and strains. 40 amniotic fluid specimens from Korean women in their second and third trimesters of pregnancy were examined for inhibiting the growth of Escherichia coli. And various factors which might affect bacterial growth inhibiting activity such as pH, initial inoculum size, concentration of amniotic fluid, and heat resistance, were also tested using a strongly inhibitory amniotic fluid specimen. Finally plate diffusion tests were carried out using other strongly inhibitory amniotic fluid. The following results were obtained: 1. Of the 40 fluid samples examined, 18 specimens(45%) had inhibitory activity and samples from women in their second trimester of pregnanancy showed non-inhibitory activity(2 specimens). 2. The pH of the fluids varied between 7.43 and 8.33. There was no correlation between pH and inhibitory activity. 3. No. 19 amniotic fluid showed bacteriostatic activity after 24 hours incubation when an inoculum of $10^2$ organisms per milliliter was used, but non-inhibitory with an inoculum of $10^3$ and $10^4$ bacteria per milliliter. 4. The content of amniotic fluid in culture media influenced E. coli growth. At 90 percent, E. coli was inhibited growth but at 10 percent and 50 percent. 5. Inhibitory activity of No. 19 amniotic fluid was retained after heating to $50^{\circ}C$ for 30 minutes or 100^{\circ}C$ for 30 minutes. 6. Plate diffusion tests with No. 27 amniotic fluid showed that 0.7ml amniotic fluid gave clear zone of growth inhibition around the central well but 0.2ml and 0.1ml amniotic fluids were not.

  • PDF