• Title/Summary/Keyword: Fluid field

Search Result 2,250, Processing Time 0.026 seconds

Flow Field Measurement in Catalytic Converter-Comparison with Computational Fluid Dynamics Analyses (촉매 변환기의 내부 유동장 측정-CFD 해석과 비교)

  • Yoo, Seoung-Chool;Jang, Sung-Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.3
    • /
    • pp.197-202
    • /
    • 2014
  • The efficiency of a catalytic converter depends on the flow distribution across a system's chemically active substrate. If irregularities or non-uniform flow patterns exist, the system's conversion efficiency decreases, whereas the manufacturing cost increases. Therefore, it is important to analyze the internal flow of a catalytic converter. In this study, flow pattern measurements along the minor axis were recorded at the mid and exit planes of a ceramic honeycomb catalytic converter at flow rates of 37.8 l/s and 94.4 l/s. Flow distributions of the measurement plans were compared with an automotive company's computed velocity profiles. Measurements along the minor axis showed uneven velocity profiles. The ${\upsilon}$-velocity components between the honeycomb bricks were small but somewhat erratic opposite the intake side of the converter, however, they became flatter in measurements recorded near the intake entrance. For almost all velocity values, the computer model suggested velocities greater than the measured values.

A Numerical Study on the Effect of Mountainous Terrain and Turbine Arrangement on the Performance of Wind Power Generation (지형에 따른 발전기 배치가 풍력 발전 성능에 미치는 영향에 관한 수치해석 연구)

  • Lee, Myung-Sung;Lee, Seung-Ho;Hur, Nahm-Keon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.10
    • /
    • pp.901-906
    • /
    • 2010
  • A three-dimensional flow simulation was performed to investigate the flow field in a wind farm on a complex terrain. The present study aims to examine the effects of mountainous terrain and turbine arrangement on the performance of wind power generation. A total of 49 wind turbines was modeled in the computational domain; detailed blade shape of the turbines was considered. Frozen rotor method was used to simulate the rotating operation. The torque acting on the turbine blades was calculated to evaluate the performance of the wind turbines. The numerical results showed details of the flow structure in the wind farm including the velocity deficit in the separated flow regions; this velocity deficit was due to the topographical effect. The effect of the wake induced by the upstream turbine on the performance of the downstream wind turbine could also be observed from the results. The methodology of the present study can be used for selecting future wind-farm sites and wind-turbine locations in a selected site to ensure maximum power generation.

Verification experiment of a ground source multi-heat pump at cooling mode (지열원 시스템 히트펌프의 냉방 성능 특성에 관한 실증 연구)

  • Lim, Hyo-Jae;Kang, Shin-Hyung;Choi, Jae-Ho;Choi, Jong-Min;Moon, Je-Myung;Kwon, Young-Seok;Kwon, Hyung-Jin;Kim, Rock-Hee
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.21-26
    • /
    • 2008
  • Recently, small and medium-sized buildings have employed a multi-heat pump. The major benefits of the multi-heat pump over a conventional system are that it is easier system to maintain along with a diversification of facility use, and high comfortability. The performance of multi-heat pump systems can be enhanced by using geothermal energy instead of air source energy. This paper describes the multi-heat pumps applied in an ground source heat pump system for an actual building. The performance of a ground source multi-heat pump installed in the field was investigated in cooling mode. The maximum COP of the systems with single U-tube and double tube ground loop heat exchangers were 6.6 and 6.0, respectively. It is suggested that the new algorithms to control the flow rate of secondary fluid for ground loop heat exchanger have to be developed in order to enhance the performance of the system.

  • PDF

CFD Analysis of Axial Flow Cyclone Separator for Subway Station HVAC System (지하역사 공기조화기에 적용 가능한 미세먼지 제거용 사이클론의 수치해석적 연구)

  • Kim, Jin-Kwan;Kim, Ho-Joong;Lee, Myung-Jun;Kim, Tae-Sung;Kwon, Soon-Bark
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.546-550
    • /
    • 2008
  • In this study, 3-dimensional Computational Fluid Dynamics (CFD) analysis was induced to simulate air flow and particle motion in the axial flow cyclone separator. The commercialized CFD code FLUENT was used to visualize pressure drop and particle collection efficiency inside the cyclone. We simulated 4 cyclone models with different shape of vane, such as turning angle or shape of cross section. For the air flow simulation, we calculated the flow field using standard ${\kappa}-{\varepsilon}$ turbulence viscous model. Each model was simulated with different inlet or outlet boundary conditions. Our major concern for the flow filed simulation was pressure drop across the cyclone. For the particle trajectory simulation, we adopted Euler-Lagrangian approach to track particle motion from inlet to outlet of the cyclone. Particle collection efficiencies of various conditions are calculated by number based collection efficiency. The result showed that the rotation angle of the vane plays major roll to the pressure drop. But the smaller rotation angle of vane causes particle collection efficiency difference with different inlet position.

  • PDF

Development and validation of a non-linear k-ε model for flow over a full-scale building

  • Wright, N.G.;Easom, G.J.;Hoxey, R.J.
    • Wind and Structures
    • /
    • v.4 no.3
    • /
    • pp.177-196
    • /
    • 2001
  • At present the most popular turbulence models used for engineering solutions to flow problems are the $k-{\varepsilon}$ and Reynolds stress models. The shortcoming of these models based on the isotropic eddy viscosity concept and Reynolds averaging in flow fields of the type found in the field of Wind Engineering are well documented. In view of these shortcomings this paper presents the implementation of a non-linear model and its evaluation for flow around a building. Tests were undertaken using the classical bluff body shape, a surface mounted cube, with orientations both normal and skewed at $45^{\circ}$ to the incident wind. Full-scale investigations have been undertaken at the Silsoe Research Institute with a 6 m surface mounted cube and a fetch of roughness height equal to 0.01 m. All tests were originally undertaken for a number of turbulence models including the standard, RNG and MMK $k-{\varepsilon}$ models and the differential stress model. The sensitivity of the CFD results to a number of solver parameters was tested. The accuracy of the turbulence model used was deduced by comparison to the full-scale predicted roof and wake recirculation zone lengths. Mean values of the predicted pressure coefficients were used to further validate the turbulence models. Preliminary comparisons have also been made with available published experimental and large eddy simulation data. Initial investigations suggested that a suitable turbulence model should be able to model the anisotropy of turbulent flow such as the Reynolds stress model whilst maintaining the ease of use and computational stability of the two equations models. Therefore development work concentrated on non-linear quadratic and cubic expansions of the Boussinesq eddy viscosity assumption. Comparisons of these with models based on an isotropic assumption are presented along with comparisons with measured data.

Wind pressure on a solar updraft tower in a simulated stationary thunderstorm downburst

  • Zhou, Xinping;Wang, Fang;Liu, Chi
    • Wind and Structures
    • /
    • v.15 no.4
    • /
    • pp.331-343
    • /
    • 2012
  • Thunderstorm downbursts are responsible for numerous structural failures around the world. The wind characteristics in thunderstorm downbursts containing vortex rings differ with those in 'traditional' boundary layer winds (BLW). This paper initially performs an unsteady-state simulation of the flow structure in a downburst (modelled as a impinging jet with its diameter being $D_{jet}$) using a computational fluid dynamics (CFD) method, and then analyses the pressure distribution on a solar updraft tower (SUT) in the downburst. The pressure field shows agreement with other previous studies. An additional pair of low-pressure region and high-pressure region is observed due to a second vortex ring, besides a foregoing pair caused by a primary vortex ring. The evolutions of pressure coefficients at five orientations of two representative heights of the SUT in the downburst with time are investigated. Results show that pressure distribution changes over a wide range when the vortices are close to the SUT. Furthermore, the fluctuations of external static pressure distribution for the SUT case 1 (i.e., radial distance from a location to jet center x=$D_{jet}$) with height are more intense due to the down striking of the vortex flow compared to those for the SUT case 2 (x=$2D_{jet}$). The static wind loads at heights z/H higher than 0.3 will be negligible when the vortex ring is far away from the SUT. The inverted wind load cases will occur when vortex is passing through the SUT except on the side faces. This can induce complex dynamic response of the SUT.

A Study on Vietnam Food Culture -Fermented Fish sauce Culture and Daily meal- (베트남의 식문화에 관한 연구 -어장문화와 일상식-)

  • Cho, Hoo-Jong;Yoon, Duk-Ihn
    • Journal of the Korean Society of Food Culture
    • /
    • v.12 no.3
    • /
    • pp.289-299
    • /
    • 1997
  • This study was performed with survay in the field and literature. The result were; 1. In Vietnam, They took their meal in three times a day. They have taken Nuoc nam (fish sauce) with sliced red pepper, half a lime, etc... in every day every night. Fish Sauce was prepared with small fish (generally fresh- water fish), the same amount of salt, and stored in 8 months, and made filltered fluid. It's Nuoc mam. They have gained protein sauce from it. 2. Their basic menu were composed with rice, soup, food with marine products and meat (generally pork), various vegetables, tropical fruit. 3. Food of cereals were Com Trang (white rice), Pho (rice noodle), Chao (rice gruel), Banh Trang (rice paper), Banh mi (bread) etc... Food of meat were Ho sua, Banh bao chien (barbecued little pork), Suon Nuon (grilled pork), Cha Lua (sausage of pork) etc..., Thit be nhung (grilled beef, Dog meat, Chicken, Duck, Frog. Food of fish were generally fresh-water fish, Ca Chien (grilled fish), Canh chua (soup with sour taste), Ca chem chung (steamed fish with fragrant vegetable), Lobster, Crab, Oyster, Cuttlefish, Shellfish, etc... Food of vegetables were Doa Hanh (Kimchi with a welsh onion), Rau xao hon hop (roasted vegetables), Goi Tom (salad), Canh he dau hu (soup) etc..., and They took much food of trophical fruit, Tra (Tea), Coffee, Lua Moi (distilled liquor). 4. For example, Their Daily meal were composed of Sup Bong Ca (Soup), Heo Sua, Banh Bao Chien (barbecued little Pork), Top Hap (steamed shrimp), Cua (steamed Crab), Luon Um (bioled a fresh-water eel), Lau Thap Cam, Hai Sam Sac Nam Dong Co, Trai Cay.

  • PDF

Crystal Chemistry and Paragenesis of Aluminum Sulphates from Mudstones of the Yeonil Group (I): basaluminite, hydrbasaluminite, and metabasaluminite (연일층군 이암에서 산출되는 알루미늄 황산염 광물의 결정화학 및 생성 (I): 배사알루미나팅, 하이드로베사알루미나이트 및 메타배사알루미나이트)

  • 노진환
    • Journal of the Mineralogical Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.1-12
    • /
    • 1998
  • In Pohang area, basaluminite accompanying a little amounts of hydrobasalumnite, super-genetically occurs as whitish cryptocrystalline (2-4 $\mu\textrm{m}$) clay-like aggregates in the vicinity of altered carbonate concretions embedded within mudstones of the Tertiary Yeonil Group. A hydrobasaluminite changed readily into a basaluminite at room temperature in air, and, in turn, into a metabasaluminite when heating to 150$^{\circ}$~30$0^{\circ}C$. For the basaluminite, a monoclinic unit-cellparameters (a=14.845$\AA$, b=10.006$\AA$, c=11.082$\AA$, $\beta$=122.15$^{\circ}$) were calculated by X-ray powder diffraction data. Its basal reflections (001 and 002) are XRD analyses strongly indicate that the aluminum sulphate mineral has a layer structure and, at least, three types of water, i.e., (1) interlayer water (9.0 wt %), (2) crystal water (8.0 wt %), and (3) structural water (19.0 wt %). may present in its lattice. Based on TG-DTG data combined with EDS and IR analyses, a new chemical formula of Al5SO4(OH)134H2O was given to the basaluminite. Field occurrence and stable isotope data ($\delta$18O, $\delta$D, $\delta$34S) for the basaluminite seem to reflect that it was formed by the leached meteoric solution from surrounding mudstones during or after uplifting. An interaction of the acid solution with carbonate concretion and the resultant local neutralization of the fluid rich in Al3+ and SO42- are major controls on the basaluminite formation.

  • PDF

Study on Thermal Stress Occurred in Concrete Energy Pile During Heating and Cooling Buildings (냉난방 가동 모사에 따른 콘크리트 에너지파일의 열응력 해석에 대한 연구)

  • Sung, Chihun;Park, Sangwoo;Kim, Byungyeon;Jung, Kyoungsik;Choi, Hangseok
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.2
    • /
    • pp.12-18
    • /
    • 2015
  • The energy pile, used for both structural foundations and heat exchangers, brings about heat exchange with the ground formation by circulating a working fluid for heating and cooling buildings. As heat exchange occurs in the energy pile, thermal stress and strain is generated in the pile body and surrounding ground formation. In order to investigate the thermo-mechanical behavior of an energy pile, a comprehensive experimental program was conducted, monitoring the thermal stress of a cast-in place energy pile equipped with five pairs of U-type heat exchanger pipes. The heating and cooling simulation both continued for 30 days. The thermal strain in the longitudinal direction of the energy pile was monitored for a 15 operation days and another 15 days monitoring followed, without the application of heat exchange. In addition, a finite element model was developed to simulate the thermo-mechanical behavior of the energy pile. A non-linear contact model was adopted to interpret the interaction at the pile-soil interface, and thermal-induced structure mechanics was considered to handle the thermo-mechanical coupled multi-field problem.

Numerical Analysis of Wave-Current Interaction Phenomenon Using the Spectral Element Method (스펙트랄요소법(SEM)을 이용한 파랑-조류 상호작용 현상 수치해석 연구)

  • Sung, Hong-Gun;Hong, Key-Yong;Kyung, Jo-Hyun;Hong, Sa-Young
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.181-186
    • /
    • 2006
  • In this paper, generation mechanisms of ocean freak waves are briefly introduced in the context of wave-current interaction phenomena. The present model of the fluid motion is based on the Navier-Stokes equations incorporating velocity-pressure formulation because of need to model the nonlinear wave interaction with spatially non-uniform current field. In order to deal with the free surface motion, an Arbitrary Lagrangian-Eulerian (ALE) description is adopted. As an accurate and efficient numerical tool, the spectral element method is presented with general features and specific treatment for the wave-current interaction problem. As an intermediate stage of development, solution procedure and characteristics aspects of the present modeling and numerical method are addressed in detail, and preliminary numerical results prove its accuracy and convergence.

  • PDF