• Title/Summary/Keyword: Fluid field

Search Result 2,250, Processing Time 0.037 seconds

Numerical Sudy on Bubbling Fluidized Bed Reactor for Fast Pyrolysis of Waste Lignocelluosic Biomass (폐목질계 바이오매스의 급속열분해 기포유동층 반응기에 대한 수치해석적 연구)

  • Lee, Ji Eun;Choi, Hang Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.10
    • /
    • pp.710-716
    • /
    • 2013
  • New and renewable energy sources have drawn attention because of climate change. Many studies have been carried out in waste-to-energy field. Fast pyrolysis of waste lignocelluosic biomass is one of the waste-to-energy technologies. Bubbling fluidized bed (BFB) reactor is widely used for fast pyrolysis of the biomass. In BFB pyrolyzer, bubble behavior influences on the chemical reaction. Accordingly, in the present study, hydrodynamic characteristics and fast pyrolysis reaction of waste lignocellulosic biomass occurring in a BFB pyrolyzer are scrutinized. The computational fluid dynamics (CFD) simulation of the fast pyrolysis reactor is carried out by using Eulerian-Granular approach. And two-stage semi-global kinetics is applied for modeling the fast pyrolysis reaction of waste lignocellulosic biomass. To summarize, generation and ascendant motion of bubbles in the bed affect particle behavior. Thus biomass particles are well mixed with hot sand and consequent rapid heat transfer occurs from sand to biomass particles. As a result, primary reaction is observed throughout the bed. And reaction rate of tar formation is the highest. Consequently, tar accounts for 66wt.% of the product gas. However, secondary reaction occurs mostly in the freeboard. Therefore, it is considered that bubble behavior and particle motions hardly influences on the secondary reaction.

Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform (수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구)

  • Namgung, Hyeong-Gyu;Park, Sechan;Kim, Minhae;Kim, Soo-Yeon;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • The imbalance of air supply and the exhaust on subway platforms has led to the installation of platform screen doors in underground subway stations. This imbalance causes the accumulation of pollutants on the platform and loss of comfort due to the lack of ventilation. In this study, a floor exhaust system was optimized using computational fluid dynamics (CFD) and an optimization program. The optimized floor exhaust system was manufactured and tested experimentally to evaluate the particle collection efficiency. CFX 17.0 and HEEDS were used to analyze the flow field and optimize the principal dimensions of the exhaust system. As a result of the three-step optimization, the optimized floor exhaust system had a total height of 1.78 m, pressure drop of 430 Pa, and particle collection capability of 61%. A fine dust particle collection experiment was conducted using a floor exhaust system that was manufactured at full scale based on the optimized design. The experiment indicated about 65% particle collection efficiency. Therefore, the optimized design can be applied to subway platforms to draw in exhaust air and remove particulate matter at the same time.

Diagnosis of the Liquid Transportation Pipe in the Petroleum Industry using Sealed Gamma-ray Source(137Cs) (밀봉감마선원(137Cs)을 이용한 석유화학산업의 유체이송배관 내 가동 중 이상 진단기술)

  • Kim, Jin-Seop;Jung, Sung-Hee;Kim, Jong-Bum
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.794-799
    • /
    • 2005
  • With the quantitative growth of the petroleum industry, the pipe facilities that connect each process increased significantly and the corresponding maintenance and repair costs of the pipe facilities increased as well. The diagnosis techniques to check a pipe efficiency while in operation are few in Korea, but in the advanced countries the pipe diagnosis using gramma-ray source was on-going research since 1960's. In this study, field experiments were performed to analyze the reasons for abnormal operation of the pipe connected to a distillation tower, and the degree of abnormality was estimated using a sealed gamma-ray source ($^{137}Cs$). Gamma radiation counts were measured by a detector (NaI) positioned outside the pipe-wall diametrically opposite to the gamma source. The results showed that a gas zone section's distribution pattern was different from the pattern of nearby fluid in a pipe. Th diagnosis technique using a gamma radiation source was proved to be an effective and reliable method, offering the information on the fluid distribution in pipe.

Carbapenemase-Producing Klebsiella oxytoca Detection Using Molecular Methods (분자학적 방법을 이용한 Carbapenemase-Producing Klebsiella oxytoca 검출)

  • Yang, Byoung Seon;Park, Ji Ae
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.4
    • /
    • pp.428-435
    • /
    • 2019
  • The rapid increase and dissemination of carbapene mases, such as Klebsiella pneumoniae carbapenemase (KPC), has become a major problem within the field of healthcare-related infection. There are few antibiotics to treat carbapenem-resistant Enterobacteriaceae (CRE) infections, so the identification of resistant bacterial mechanisms is critical to initiate infection control and conduct epidemiological research. A rapid and effective method for detecting KPC-producing bacteria is needed to avoid therapeutic failures and introduce measures to prevent and control the dissemination of these multi-resistant bacteria. During the study period, 31 isolates (seven isolates of Acinetobacter spp., six isolates of Morganella morganii, five isolates of Pseudomonas aeruginosa, five isolates of Proteus mirabilis, one isolate of Proteus vulgaris, two isolates of Enterobacter cloacae, one isolate of Enterobacter aerogenes, one isolate of Klebsiella pneumoniae, one isolate of Klebsiella oxytoca, one isolate of Serratia marcescens and one isolate of Escherichia coli) were identified by the VITEK. Gram negative rod bacteria were the most frequently isolated from urine (35.5%), blood (19.4%), sputum (16.1%), pus (9.7%), ascitic fluid (9.7%), tracheal aspirates (6.5%) and bile juice (3.2%). Analysis using the PCR method identified the blaKPC gene in the K. oxytoca1 strain, but the blaIMP, blaVIM and blaOXA-48 genes are not amplified. In conclusion, diagnosis using the PCR method can accurately and quickly diagnose KPC, thus establishing quick preventive measures to prevent the spread of KPC in hospitals.

A study on the optimization design of pulse air jet system to improve bag-filter performance (여과집진기의 탈진 성능 향상을 위한 충격 기류 분사 시스템 최적화 설계에 관한 연구)

  • Hong, Sung-Gil;Jung, Yu-Jin;Park, Ki-Woo;Jeong, Moon-Heon;Lim, Ki-Hyuk;Suh, Hye-Min;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3792-3799
    • /
    • 2012
  • The dedusting characteristics of pulse air jet type dedusting system which is widely applied in the industries were identified by utilizing the computational fluid dynamics (CFD) and the dedusting performance in modified shape of dedusting unit was compared in this study. The review on the dedusting air volume, air stream distribution and inflow velocity distribution on each shape of dedusting part showed that the case of installing the nozzle on the blow tube (Case-3) and the case of installing the double intaking tube to the venturi (Case-4 and Case-5) were more excellent than the structure (Case-1) which is widely applied in the field in its amplification effect on the air volume and extension of stream width. The specification of venturi was decided to apply the selected Case-5 for the option of the commercial back filter. It is considered that the dedusting air volume will be maintained in maximum in the case of 50 mm and 90 mm for the diameter of internal and external intaking pipe respectively.

Estimation of 3-D Hydraulic Conductivity Tensor for a Cretaceous Granitic Rock Mass: A Case Study of the Gyeongsang Basin, Korea (경상분지 백악기 화강암 암반에 대한 삼차원 수리전도텐서 추정사례)

  • Um, Jeong-Gi;Lee, Dahye
    • The Journal of Engineering Geology
    • /
    • v.32 no.1
    • /
    • pp.41-57
    • /
    • 2022
  • A workflow is presented to estimate the size of a representative elementary volume and 3-D hydraulic conductivity tensor based on fluid flow analysis for a discrete fracture network (DFN). A case study is considered for a Cretaceous granitic rock mass at Gijang in Busan, Korea. The intensity and size of joints were calibrated using the first invariant of the fracture tensor for the 2-D DFN of the study area. Effective hydraulic apertures were obtained by analyzing the results of field packer tests. The representative elementary volume of the 2-D DFN was determined to be 20 m square by investigating the variations in the directional hydraulic conductivity for blocks of different sizes. The directional hydraulic conductivities calculated from the 2-D DFN exhibited strong anisotropy related to the hydraulic behavior of the study area. The 3-D hydraulic conductivity tensor for the fractured rock mass of the study area was estimated from the directional block conductivities of the 2-D DFN blocks generated for various directions in 3-D. The orientations of the principal components of the 3-D hydraulic conductivity tensor were found to be identical to those of delineated joint sets in the study area.

Numerical Analysis of Runup and Wave Force Acting on Coastal Revetment and Onshore Structure due to Tsunami (해안안벽과 육상구조물에서 지진해일파의 처오름 및 작용파력에 관한 수치해석)

  • Lee, Kwang Ho;Kim, Chang Hoon;Kim, Do Sam;Yeh, Harry;Hwang, Young Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3B
    • /
    • pp.289-301
    • /
    • 2009
  • In this work, wave run-up heights and resultant wave forces on a vertical revetment due to tsunami (solitary wave) are investigated numerically using a numerical wave tank model called CADMAS-SURF (CDIT, 2001. Research and Development of Numerical Wave Channel (CADMAS-SURF). CDIT library, No. 12, Japan.), which is based on a 2-D Navier-Stokes solver, coupled to a volume of fluid (VOF) method. The third order approximate solution (Fenton, 1972. A ninth-order solution for the solitary wave. J. of Fluid Mech., Vol. 53, No.2, pp.257-271) is used to generate solitary waves and implemented in original CADMAS-SURF code. Numerical results of the wave profiles and forces are in good agreements with available experimental data. Using the numerical results, the regression curves determined from the least-square analysis are proposed, which can be used to determine the maximum wave run-up height and force on a vertical revetment due to tsunami. In addition, the capability of CADMAS-SURF is demonstrated for tsunami wave forces acting on an onshore structure using various configuration computations including the variations of the crown heights of the vertical wall and the position of the onshore structure. Based on the numerical results such as water level, velocity field and wave force, the direct effects of tsunami on an onshore structure are discussed.

Performance of Various Drug-Eluting Stent Geometries Measured Using Computational Analysis (여러 형상을 고려한 약물분출 스텐트의 성능에 대한 수치해석적 연구)

  • Seo, Tae-Won;Barakat, Abdul I.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.601-607
    • /
    • 2012
  • In this study, we performed computational fluid dynamic simulations to explore how the detailed design of drug-eluting stents affects both the flow field in the vicinity of the stent as well as the concentration of the eluted drug at the endothelial cell surface. Simulations were performed on three idealized stent geometries we developed and on geometries approximating three commercial stents,: Medtronic's Aurora stent, Cordis's BX Velocity stent, and Boston Scientific's Wallstent. An important contribution of the present study is the introduction of the stent effectiveness index (EI), which provides a quantitative assessment of stent performance and an objective basis for comparing the performance of different stents. Among the three commercial stents studied, our simulations have revealed that the BX Velocity stent is associated with the lowest in-stent EI values for the range of flow Reynolds numbers studied ($200{\leq}Re{\leq}800$). In addition to commercial stent designs, we investigated the EI in three idealized stents and determined that a spiral stent provides excellent performance (low EI) under all flow conditions investigated.

Investigation of flowfield characteristics of a square prism having a front triangular prism by PIV (PIV에 의한 정면에 삼각주를 가진 정방형주 주위의 유동장 특성분석)

  • Ro, Ki-Deok;Kim, Jae-Dong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.205-209
    • /
    • 2016
  • The flowfield characteristics of a square prism having a small triangular prism at the upstream side were investigated by visualizing the flow field using PIV. The ratio of the width of the triangular prism to that of the square prism and the gap ratios between the square and triangular prisms were selected as the experimental parameters. The results are summarized as follows. The Strouhal number measured on the wake side of the square prism, which had the same characteristics as the drag reduction rate, increased, and then decreased with the gap ratio for the same width ratio. For a square prism having a small triangular prism, the stagnation regions were represented at the upstream and downstream sides of the square prism. The size of the stagnation region increased with the width ratio at the upstream side of the square prism, and decreased at the downstream side.

An integrated model for pore pressure accumulations in marine sediment under combined wave and current loading

  • Zhang, Y.;Jeng, D.-S.;Zha, H.-Y.;Zhang, J.-S.
    • Geomechanics and Engineering
    • /
    • v.10 no.4
    • /
    • pp.387-403
    • /
    • 2016
  • In this paper, an integrated model for the wave (current)-induced seabed response is presented. The present model consists of two parts: hydrodynamic model for wave-current interactions and poro-elastic seabed model for pore accumulations. In the wave-current model, based on the fifth-order wave theory, ocean waves were generated by adding a source function into the mass conservation equation. Then, currents were simulated through imposing a steady inlet velocity on one domain and pressure outlet on the other side. In addition, both of the Reynolds-Averaged Navier-Stokers (RANS) Equations and $k-{\varepsilon}$ turbulence model would be applied in the fluid field. Once the wave pressures on the seabed calculated through the wave-current interaction model, it would be applied to be boundary conditions on the seabed model. In the seabed model, the poro-elastic theory would be imposed to simulate the seabed soil response. After comparing with the experimental data, the effect of currents on the seabed response would be examined by emphasize on the residual mechanisms of the pore pressure inside the soil. The build-up of the pore water pressure and the resulted liquefaction phenomenon will be fully investigated. A parametric study will also be conducted to examine the effects of waves and currents as well as soil properties on the pore pressure accumulation.