• Title/Summary/Keyword: Fluid dynamics

Search Result 3,476, Processing Time 0.034 seconds

Effect of Boundary Slip Phenomena in Nanoimprint Lithography Process (나노임프린트 리소그래피 공정에서 Slip에 의한 경계 효과)

  • Lee, Young-Hoon;Kim, Nam-Woong;Sin, Hyo-Chol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.2
    • /
    • pp.144-153
    • /
    • 2009
  • It is widely known that no-slip assumptions are often violated on regular basis in micrometer- or nanometer-scale fluid flow. In the case of cavity-filling process of nanoimprint lithography(NIL), slip phenomena take place naturally at the solid-to-liquid boundaries, that is, at the mold-to-polymer or polymer-to-substrate boundaries. If the slip or partial slip phenomena are promoted at the boundaries, the processing time of NIL, especially of thermal-NIL which consumes more tact time than that of UV-NIL, can be significantly improved. In this paper it is aimed to elucidate how the cavity-filling process of NIL can be influenced by the slip phenomena at boundaries and to what degree those phenomena increase the process rate. To do so, computational fluid dynamics(CFD) analysis of cavity filling process has been carried out. Also, the effect of mold pattern shape and initial thickness of polymer resist were considered in the analysis, as well.

Behavior Characteristics of Swirl-Twin Spray with Changing Swirl Angle (선회각도변화에 따른 2유체 선회분무의 거동특성)

  • Kang, Wan-Bong;Cha, Keun-Jong;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.943-948
    • /
    • 2000
  • The Twin-fluid Swirl Nozzles are used in many parts of the industry to produce homogeneous spray. This study is to investigate the effects of outer air swiller and inner water swiller on atomization of liquid.. The experiment was carried out with increasing air-flow rate at constant liquid-flow rate and with changing outer air swiller angle and inner water swiller angle. A Particle Dynamics Analyzer(PDA) was used to measure drop size, mean and ms values of axial velocity, number density and Sauter mean diameter(SMD). The axial mean velocity and SMD of droplets were measured along the center line and radial directions. It was found that the higher air flow-rate resulted in the smaller Sauter mean diameter of liquid spray and the higher axial mean velocity of droplets. This experimental results will be conveniently used for the preliminary design stage of twin-fluid nozzle development.

  • PDF

Numerical Analysis of Unsteady Thermo-Fluid Behavior for Launched Body using Chimera Mesh (키메라 격자를 이용한 발사체의 비정상 열유동해석)

  • Son, D.H.;Sohn, C.H.;Ha, J.H.
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1013-1018
    • /
    • 2010
  • This paper presents a numerical evaluation of the launch dynamics and thermo-fluid phenomena for gas generator launch eject system. The existing gas dynamic model for launching eject body used ideal gas and adiabatic assumption with empirical energy loss model. In present study, a turbulent Navier-Stokes solver with CHIMERA mesh is employed to predict the detail unsteady thermo-fluid dynamics for the launched body. The calculation results show that proper grid number is necessary for good agreement with experimental data. The important effects for accurate prediction are a gap distance and thermal boundary condition on the wall. The computational results show good agreement with experiment data.

Study on Fluid Flow and Thermal Characteristics in a Nanoscale Channel Using MD Simulation (분자 동역학 시뮬레이션을 이용한 나노 스케일 채널 내에서의 유체 유동 및 열적 특성에 관한 연구)

  • Choi, Yong-Seok;Kim, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1880-1884
    • /
    • 2004
  • To analyze the fluid flow and thermal characteristics in a nanoscale system, the planar Poiseuille flow of a Lennar-Jones liquid through parallel plates formed by fixed atoms is studied using nonequilibrium molecular dynamics simulations. The role of important simulation parameters such as the channel width, the magnitude of external field, the temperatures of the top and bottom plates, and the interaction potential parameter between fluid and wall atoms, which affect flow patterns and heat transfer rate inside the channel, are investigated. Under the various simulation conditions, interesting phenomena deviated from the continuum predictions have found.

  • PDF

Numerical Study on the Effect of the Internal Temperature Distribution in the Cyclone Dust Collector (사이클론 집진장치의 내부 온도 변화에 따른 집진효율에 관한 전산해석적 연구)

  • Hyun, Daegeun;Cha, Hyuksang
    • Particle and aerosol research
    • /
    • v.10 no.4
    • /
    • pp.155-162
    • /
    • 2014
  • The internal temperature will change depending on operation conditions and material of cyclone dust collector. This study compares the results of collection efficiency and temperature distribution on the different heat flux at wall of dust collector. The previous researcher's experiment results were used to confirm the reliability of CFD(Computational Fluid Dynamics) model. Based on this verified CFD model, we extended the analysis on the cyclone dust collectors. In CFD study, we used RNG k-epsilon model for analysis of turbulence flow, fluid is air, the velocity at inlet is 10 m/s, the temperature of air is $600^{\circ}C$. Because of the difference of outer vortex and inner vortex temperature, the collection efficiency will reduce with the increase of heat flux, showed the highest collection efficiency at heat insulation.

Thermal Distribution of Bi-Te Thermoelectric Module with the thickness of Polymer Sheet (고분자 필름의 두께변화에 따른 Bi-Te계 열전모듈의 열분포 특성)

  • Byeon, Jong-Bo;Kim, Bong-Seo;Park, Soo-Dong;Lee, Hee-Woong;Kim, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1675-1677
    • /
    • 2005
  • In case of attaching thermoelectric module and heat source, the polymer sheet is attached on the $AL_{2}O_3$ plate, which Is cold and hot side of thermoelectric module, in order to enhance mechanical safty of the system. It is impossible to calculate the exact distribution of temperature and flow pattern of inner gap of thermoelectric module. Therefore CFD(Computational Fluid Dynamics) analysis was executed to determine the thermo-fluid phenomena and distribution by Fluent. As the result of these analysis, heat transfer was dominated by conduction and the difference of temperature was linear distribution according to the thickness of polymer sheet.

  • PDF

Research on the Output Characteristic of Thermoelectric Module according to the thickness variation of Polymer Pad (고분자 필름의 두께변화에 따른 열전소자의 출력 특성변화에 관한 연구)

  • Jang, Ho-Sung;Kim, Jae-Jung;Kim, In-Kwan;Kim, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.976-981
    • /
    • 2006
  • In case of attaching thermoelectric module and heat source, the polymer pad is attached on the $Al_2O_3$ plate, which is cooling side of thermoelectric module, in order to enhance mechanical safety of the system. It is impossible to calculate the exact distribution of temperature and flow pattern of inner gap of thermoelectric module. Therefore CFD(Computational Fluid Dynamics) analysis was executed to determine the thermo-fluid phenomena and distribution by Fluent. As the result of these analysis, heat transfer was dominated by conduction and the difference of temperature was linear distribution according to the thickness of polymer sheet.

  • PDF

Diffusion Range and Pool Formation in the Leakage of Liquid Hydrogen Storage Tank Using CFD Tools

  • Kim, Soohyeon;Lee, Minkyung;Kim, Junghwan;Lee, Jaehun
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.653-660
    • /
    • 2022
  • In liquid hydrogen storage tanks, tank damage or leakage in the surrounding pipes possess a major risk. Since these tanks store huge amounts of the fluid among all the liquid hydrogen process facilities, there is a high risk of leakage-related accidents. Therefore, in this study, we conducted a risk assessment of liquid hydrogen leakage for a grid-type liquid hydrogen storage tank (lattice-type pressure vessel (LPV): 18 m3) that overcame the low space efficiency of the existing pressure vessel shape. Through a commercially developed three-dimensional computational fluid dynamics program, the geometry of the site, where the liquid hydrogen storage tank will be installed, was obtained and simulations of the leakage scenarios for each situation were performed. From the computational flow analysis results, the pool formation behavior in the event of liquid hydrogen leakage was identified, and the resulting damage range was predicted.

Oscillating Water Column (OWC) Wave Energy Converter Part 1: Fixed OWC

  • Yang, Hyunjai;Jung, Hyen-Cheol;Koo, WeonCheol
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.280-294
    • /
    • 2022
  • This study reviews the recent development and research results of a fixed oscillating water column (OWC) wave energy converter (WEC). The OWC WEC can be divided into fixed and floating types based on the installation location and movement of the structure. In this article, the study on a stationary OWC WEC, which is close to commercialization through the accumulation of long-term research achievements, is divided into five research categories with a focus on primary energy conversion research. These research categories include potential-flow-based numerical analysis, wave tank experiments, computational fluid dynamics analyses toward investigation of fluid viscous effects, U-shaped OWC studies that can amplify water surface displacement in the OWC chamber, and studies on OWC prototypes that have been installed and operated in real sea environments. This review will provide an overview of recent research on the stationary OWC WEC and basic information for further detailed studies on the OWC.

SIMILARITY ANALYSIS OF HEART ARRHYTHMIA WITH FLUID VORTEX-NUMERICAL APPROACH (유체와류현상과 심장부정맥의 상관성 연구-수치적 접근)

  • Shim, E.B.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.221-223
    • /
    • 2010
  • Considering the similarity between fluid vortex and arrhythmogenic reentrant waves in heart, we applied the non-dimensionalization method in fluid dynamics to arrhythmia analysis and discovered a new non-dimensional simulation results, there was a threshold value of the number that resulted in the induction of a reentrant wave.

  • PDF