• 제목/요약/키워드: Fluid Capacity

검색결과 564건 처리시간 0.026초

지반 기진력을 받는 구조물의 진동제어를 위한 자기유변 감쇠기의 실험적 연구 (An Experimental Study on a Magneto-Rheological Fluid Damper for Structural Control Subject to Base Excitation)

  • 김병현;정종안;문석준
    • 한국소음진동공학회논문집
    • /
    • 제14권8호
    • /
    • pp.767-773
    • /
    • 2004
  • Semi-active control systems have attracted a great deal of attention in recent years, because they offer the adaptability of active devices without requiring large Power sources. One of the most Promising semi-active devices proposed for structural control is magneto-rheological fluid dampers (MR damper). In this paper, an MR damper having the capacity of about 1 ton was designed and fabricated. and series of tests were performed to grasp the fundamental Performance characteristics of it. It was also applied to a 6-story steel structure under random excitation and 3-different seismic excitations for the confirmation of its validity on structural vibration absorption. Through this study, the techniques and know-hows for MR damper production were acquired.

나노 파운틴펜의 동적해석에 관한 연구 (A Study on Dynamic Analysis of Nano Fountain Pen)

  • 이영관;김훈모;김윤제;이석한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.922-929
    • /
    • 2006
  • In this study, flow characteristics of the FPN (Fountain Pen Nano-Lithography) using active membrane pumping are investigated. This FPN has integrated chamber, micro channel, and high capacity reservoir for continuous ink feed. The most important aspect in this probe provided control of fluid injection using active membrane pumping in chamber. The flow rates in channel by capillary force are theoretically analyzed, including the control of mass flow rates by deflection of membrane. The above results are compared with numerical simulations that calculated by commercial code, FLUENT. The velocity of fluid in micro channel shows linear behaviors. And the mass flows are proportional to the second order function of pumping pressure that is imposed to membrane.

  • PDF

Performance Evaluation of a Variable Frequency Heat Pump Air Conditioning System for Electric Bus

  • Peng, Qinghong;Du, Qungui
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권1호
    • /
    • pp.13-22
    • /
    • 2015
  • This study presents a simulation model of a heat pump air conditioning system with a variable capacity compressor and variable speeds fans for electric bus. An experimental sample has been developed in order to check results from the model. Effects on system performance of such working conditions as compressor speed, evaporator fans speeds and the condenser fans speeds have been simulated by means of developed model. The results show that the three speeds can be adjusted simultaneously according to actual working condition so that the AC system can operate under the optimum state which the control objects want to achieve. It would be a good and simple solution to extend the driving ranges of EVs because of the highest efficiency and the lowest energy consumption of AC system.

공동주택 연도 내의 자연 대류를 고려한 열-유동 해석 (Numerical Study on the Natural-Convection in a Shaft of an Apartment)

  • 박성근;김상규;용호택;최형권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.88-93
    • /
    • 2005
  • In this paper, the heat and fluid flow analysis in a shaft of an apartment has been performed in order to investigate the pressure distribution inside a shaft considering both natural and forced convection. The present CFD approach can be used in estimating the capacity of roof ventilator of an apartment reasonably. Furthermore, flow patterns inside a shaft have been examined for some operating conditions of hood system.

  • PDF

회전형(回轉型) 축열식(蓄熱式) 열교환기(熱交換器)에서의 온도효율(溫度效率)에 관한 연구(硏究) (A Study on the Temperature Effectiveness of the Rotary Type Regenerative Heat Exchanger)

  • 김광수
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 1989
  • This paper treats the temperature effectiveness of the two-fluid counterflow regenerator in a rotary type. To avoid continual interpolation and to obtain the simple result in calculating that, it obtained the particular solution for the direct-transfer-type counterflow heat exchanger by the graphical procedures. Also, it introduced the empirical formula for the influence of the ratio of rotor matrix to minimum working fluid heat capacity rate with the particular solution induced. Particularly, substituting the published results of temperature effectiveness into the program, it obtained the simple and convenient equation which can applicate in the counterflow regenerator in a rotary type. To compare and discuss the results induced, selecting the regenerative air preheater and applying the their running datum and specifications to the related results, it shows that the above results are agree with the published results within absolute relative error, 3.0%.

  • PDF

Fluid-Structure Interaction Modeling and Simulation of CMP Process for Semiconductor Manufacturing

  • Sung, In-Ha;Yang, Woo-Yul;Kwark, Ha-Slomi;Yeo, Chang-Dong
    • 정보저장시스템학회논문집
    • /
    • 제7권2호
    • /
    • pp.60-64
    • /
    • 2011
  • Chemical mechanical planarization is one of the core processes in fabrication of semiconductors, which are increasingly used for information storage devices like solid state drives. For higher data capacity in storage devices, CMP process is required to show ultimate precision and accuracy. In this work, 2-dimensional finite element models were developed to investigate the effects of the slurry particle impact on microscratch generation and the phenomena generated at pad-particle-wafer contact interface. The results revealed that no plastic deformation and corresponding material removal could be generated by simple impact of slurry particles under real CMP conditions. From the results of finite element simulations, it could be concluded that the pad-particle mixture formed in CMP process would be one of major factors leading to microscratch generation.

10kW급 상반전 조류터빈의 설계와 성능에 관한 연구 (Design and Performance Evaluation of a 10kW Scale Counter-Rotating Tidal Turbine)

  • 황안둥;양창조
    • 한국유체기계학회 논문집
    • /
    • 제17권1호
    • /
    • pp.47-53
    • /
    • 2014
  • This paper aims to present the design and performance evaluation of a counter-rotating tidal turbine using CFD and to compare its performance with single rotor. The device scale is 10kW and the rotating part consists of two rotors which rotate in opposite direction. Compared with conventional single rotor, the counter-rotating system shows higher power efficiency at high stream velocity but lower efficiency at low stream velocity. The added counter-rotated rotor together helps improve the energy absorption capacity but has influence on the upstream rotor that reduces its performance. In terms of power capture, the designed counter-rotating tidal turbine is more advantageous in high speed tidal condition.

표면조직 가공한 유압부품면에서의 윤활특성 (Lubrication Characteristics of Surface Textured Hydraulic Machine Components)

  • 이준오;박태조
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권4호
    • /
    • pp.26-31
    • /
    • 2012
  • Friction reduction between sliding hydraulic machine components is required to improve efficiency and reliability of hydraulic machineries. It is recently reported that surface texturing on sliding bearing surfaces can reduce the friction force highly. In this paper, numerical analysis is carried out to investigate the effect of dimple numbers and inlet boundary pressures on the lubrication characteristics of a parallel sliding bearing using a commercial computational fluid dynamics (CFD) code, FLUENT. The results show that the pressure distribution, load capacity, dimensionless friction force and leakage with dimple number and their locations, and inlet pressures. The overall lubrication characteristics are highly affected by dimple numbers and boundary pressure. The numerical method adopted and results can be used in design of efficient hydraulic machine components.

열전소자와 PF Type 진동형 히트파이프를 이용한 냉.난방기에 관한 연구 (The Experimental Study on Cooling-Heating System Using Thermoelectric Module and Parallel Flow Type Oscillating Heat Pipe)

  • 김종수;임용빈;조원호
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.741-747
    • /
    • 2004
  • The purpose of this study was to develop a cooler/heater using a thermoelectric module combined with a parallel flow type oscillating heat pipe with R-142b as a work ing fluid. The experiment was performed for 16 thermoelectric modules (6 A/15 V, size: 40${\times}$40${\times}$4 mm), varying design parameters of the heat pipe (inclination angle, working fluid charging ratio, etc) . Experimental results indicate that the optimum charging ratio and the inclination angle of the parallel flow type oscillating heat pipe were 30% by volume and 30%, respectively. The maximum cooler/heater capacity were 479W (COP : 0.47) and 630W (COP : 0.9), respectively.

다공성소결윅구조에 따른 루프 히트파이프에서 압력손실의 이론적 분석 (Theoretical Analysis of the Pressure Drop in Loop Heat Pipe by Sintered Porous Wick Structure)

  • 이기우;이욱현;박기호;이계중;전원표;인현만
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1225-1230
    • /
    • 2004
  • In this paper, the pressure drops were investigated according to the sintered porous wick structure in loop heat pipe(LHP) by theoretical analysis. LHP has the wick only in evaporator for the circulation of working fluid, so utilizes porous wick structure which pore diameter is very small for large capillary force. This paper investigates the effects of different parameters on the pressure drops of the LHP such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity. Working fluid is water and the material of sintered porous wick is copper. According to the these different parameters, capillary pressure, pressure drop in wick were analized by theoretical design method of LHP.

  • PDF