• Title/Summary/Keyword: Flue-gas temperature

Search Result 230, Processing Time 0.022 seconds

A Study on the Oxy-Combustion of the Coal in Drop Tube Furnace (Drop Tube Furnace에서 석탄의 순산소 연소 특성)

  • Roh, Seon Ah;Yun, Jin Han;Lee, Jung Kyu;Keel, Sang In;Min, Tai Jin;Kim, Sang-Bok;Park, In-Yong;Han, Bangwoo;Kim, Jin-Tae
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.367-371
    • /
    • 2021
  • The oxy-combustion system is one of the carbon recovery and storage technologies (CCS: Carbon capture & storage) that performs coal combustion using pure oxygen and recirculated flue gas. This is a technology that facilitates storage of carbon dioxide by generating an exhaust gas consisting of only carbon dioxide without a process of separating carbon dioxide and nitrogen when coal is burned using pure oxygen and recirculated flue gas mixture instead of a conventional air combustion system that produces carbon dioxide and nitrogen mixed exhaust gas. In this study, the characteristics of generated NO and SO2 as atmospheric pollutants during oxy-combustion were examined using O2/CO2 mixed simulation gas. The reaction temperature was varied from 900 ℃ to 1200 ℃ and oxygen partial pressure was varied from 30% to 50%. The results showed that NO and SO2 concentrations in flue gas increased as the oxygen concentration and the reaction temperature in the furnace increased. The partial pressure of CO2 in flue gas also increased as the oxygen concentration and the reaction temperature in the furnace increased. As a results of comparing NO production of 30% O2/CO2 oxy-combustion with air combustion, NO in flue gas increased with reaction temperature in both experiments and NO of oxy-combustion was 40 ~ 80 ppm lower than that of air combustion.

Desulfurization Characteristics of Domestic Anthracite by Limes at Bench Scale Pressurized Fluidized Bed Combustor . (벤치규모 가압유동층연소로에서 석회석에 의한 국내무연탄의 탈황특성)

  • Han, Geun-Hui;Ryu, Jeong-In;Jin, Gyeong-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1373-1383
    • /
    • 2001
  • The desulfurization characteristics of anthracite in a bench scale pressurized fluidized bed combustor are investigated. The coal used in the experiment is domestic anthracite from Kangwon Taeback area. The desulphurization experiment is performed with limestone from Chungbuk Danyang. The pressure of the combustor is maintained at 6 atm, and the combustion temperatures are 850, 900, and 950$\^{C}$. The superficial gas velocities are 0.9, 1.1, and 1.3 m/s. The excess air ratio is varied from 5 to 35%. The Ca/S mole ratios are 0.5, 1.5, 2.5 and 4.5 mole. All experiments are executed at 2m bed height. Consequently, SO$_2$ concentration in the flue gas is increased with incresing bed temperature and superficial gas velocity. However SO$_2$ concentration is decreased with incresing excess air ratio and Ca/S mole ratio.

The Studies on the Thermal Resistant Properties of $WO_3/TiO_2$ and $V_2O_5-WO_3/TiO_2$ Catalysts for NOx Reduction of Flue Gases from Industrial Boiler and on Catalyst Surface Acid Characteristics (産業用 보일러의 燃燒 排가스 中 NOx 處理를 위한 SCR 用 $WO_3/TiO_2$$V_2O_5/TiO_2$ 觸媒들의 耐熱特性과 表面 酸特性에 關한 硏究)

  • 이중범;임상윤;정석진;성준용
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.31-42
    • /
    • 1990
  • In order to suggest an efficient catalyst systems for NOx reduction of flue gases from industrial boilers, $TiO_2$ supported $WO_3-V_2O_5, V_2O_5$ and $WS_2$ catalysts were tested for the performances of NOx reduction at high reactin temperature range (250-500$^\circ$C) using a simulated flue gas system. It was found that while the proposed $WO_3/TiO_2$ and $WO_3-V_2O_5/TiO_2$ catalysts showed a significant high NOx reduction efficiency at about 350-400$^\circ$C, the conventional commercial catalyst of $V_2O_5/TiO_2$ showed a significant drop in NOx reduction efficiency due to the excessive $NH_3$ oxidation. From the measurement of surface acidities of those catalysts, it was found that the acidity are well correlated with the activities of NOx reduction. The reason of high activity of $WO_3$ series catalysts at high reaction temperature seems due to the low value of surface excess oxygen compared with that of $V_2O_5/TiO_2$ seems equivalent to the acid site of that catalyst.

  • PDF

Adsorption characteristics of $SO_2$ on Vermi Cast (지렁이 분변토의 $SO_2$ 가스 흡착특성)

  • 김춘희;고경숙;안철우
    • Journal of Environmental Science International
    • /
    • v.9 no.2
    • /
    • pp.145-149
    • /
    • 2000
  • The purpose of this study was to determine whether Vermi Cast could be used effectively to remove $SO_2$ from flue gas, and then to investigate optimum adsorption conditions. The Vermi Cast used as adsorbent was mechanically screened with 8~20 mesh sieve. The adsorption data for $SO_2$ were regressed using the Freundlich isotherm. The fit was generally satisfactory ($R^2$=0.945~0.982). With the temperature changes from 2$0^{\circ}C$ to 4$0^{\circ}C$, the constant k in Freundlich isotherm qe= $kCe^{1/n}$, decreased from 1.409 at 2$0^{\circ}C$to 0.297 at 4$0^{\circ}C$, and the exponent 1/n were decreased from 0.343 to 0.134. With the bed depth changes from 10cm to 30cm, the adsorption capacity expressed as mmol of $SO_2$ adsorbed per g of Vermi Cast increased from 0.247 to 0.381. Moisture content is an important parameter in the $SO_2$ adsorbed were observed over 0.3mmol $SO_2$ /g Vermi Cast. The best adsorption capacity was 0.487mmol $SO_2$ /g Vermi Cast, and it was obtained with moisture content 37%, temperature 2$0^{\circ}C$. From the above results, ti might be concluded that Vermi Cast is effectively as a good adsorbent to remove $SO_2$ from flue gas.

  • PDF

Determination of Char Oxidation Rates with Different Analytical Methods (국내 수입탄 촤의 산화반응률 측정을 위한 해석기법 비교)

  • Lee, Byoung-Hwa;Song, Ju-Hun;Kang, Ki-Tae;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.11
    • /
    • pp.876-885
    • /
    • 2009
  • Char oxidation experiments were performed with a sub-bituminous roto-middle coal in the Drop Tube Furnace (DTF) at atmospheric pressure condition. While temperatures varied between 900, 1100, 1400 $^{\circ}C$, particle size, mass, particle temperature, and CO/$CO_2$ concentration were obtained to be used for kinetic analysis of the char oxidation. This study addresses several different methods to analyze the char consumption rate, which are classified as energy balance method, ash-traced mass method, flue-gas based method, and particle size based method. The char consumption rate obtained with such methods was compared with the results of Monson et al.$^{(24)}$ While there are some differences between them because of differences in experimental apparatus and parameters to be measured, the kinetic results seems to be reasonable enough to be incorporated in a numerical modeling of coal combustion.

Adsorption Characteristic of Carbon Dioxide on Activated Carbon Impregnated with Piperazine (Piperazine으로 함침된 활성탄의 이산화탄소 흡착 특성)

  • Choi, Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.22 no.7
    • /
    • pp.847-853
    • /
    • 2013
  • Functionalized adsorbent has been synthesized by piperazine(Pz) on activated carbon. Quantitative estimations of $CO_2$ were undertaken using gas chromatography with GC/TCD and the prepared adsorbents were characterized by BET surface area and FT-IR. It was also studied effect of various parameters such as piperazine loadings and adsorption temperature. The specific surface area decreased from $1212.0m^2/g$ to $969.8m^2/g$ by impregnation and FT-IR revealed a N-H functional group at about $1400cm^{-1}$ to $1700cm^{-1}$. The $CO_2$ adsorption capacity at $20^{\circ}C$ and $50{\sim}100^{\circ}C$ was as follow: AC > Pz(10)-AC> Pz(30)-AC> Pz(50)-AC at $20^{\circ}C$ and Pz(10)-AC > AC > Pz(30)-AC> Pz(50)-AC at $50{\sim}100^{\circ}C$. Therefore, for high temperature flue gas condition, the Pz(10)-AC showed the highest adsorption capacity due to physical adsorption and chemical adsorption by amino-group content. The results suggest that activated carbon impregnated with Pz is an effective adsorbent for $CO_2$ capture from real flue gases above $50^{\circ}C$.

The Experimental Study on Simultaneous Measurements of $O_2$ Concentration and Temperature of Flue Gas Using a Single Diode Laser (다이오드 레이저를 이용한 배기가스 $O_2$ 농도 및 온도 동시 측정에 관한 실험적 연구)

  • Kim, Se-Won;Shin, Myoung-Chul;Lee, Chang-Yeop;Youn, Sung-Woon;Kim, Young-Il
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.1
    • /
    • pp.12-21
    • /
    • 2012
  • Simultaneous measurements of oxygen concentration and temperature using diode laser in the combustion environment are successfully accomplished. A single DFB type diode laser of 760 nm line centre frequency is used and the scanned-wavelength direct absorption spectroscopy method and wavelength modulation spectroscopy method are applied to measure absorption signals below 793 K temperature region. The experimental results show that oxygen concentration are measured within 1% accuracy and temperature are measured within 5% accuracy. This new method of simultaneous measurements of concentration and temperature with a single diode laser shows a great promise.

Spraying and Combustion Characteristics of Heavy Oil in the Gun Type Burner for Hot Air Heater (온풍난방기용 건타입 중유버너의 분사특성과 연소특성)

  • 김영중;유영선;장진택;윤진하;연태용
    • Journal of Biosystems Engineering
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 1999
  • To find the best combustion conditions in the heavy oil burner kinetic viscosity of heavy oil A, B and C at different temperature range, from 40 to 140$^{\circ}C$, and the droplet sizes of the heavy oils at different temperature and pump pressure were measured. And, combustion characteristics were investigated under the different conditions : two different heavy oil and three different oil temperature. At temperature of 70, 100, 130$^{\circ}C$ the kinetic viscosity of heavy oil A and B are 7.9, 5.7, 4.3 and 30.4, 13.7, 7.9cSt, respectively. The greatest and smallest viscosity were 7,455 cSt at C oil on 27$^{\circ}C$ and 4.26cSt at A oil on 140$^{\circ}C$. The magnitude of viscosity difference between at 100$^{\circ}C$ and 140$^{\circ}C$ under 6 cSt in cases of A and B oil, but more than 30cST on C oil. Of the droplet sizes, the biggest and smallest droplet size in A oil were 98$\mu\textrm{m}$ at oil temperature of 130$^{\circ}C$(4.3cSt), pump pressure of 1.57MPa and 72$\mu\textrm{m}$ at 70$^{\circ}C$(7.9cSt), 2.35MPa, respectively. It appeared that as spraying pressure increased the droplet size decreased, however, no distinct differences were found in the effects of kinetic viscosity on the droplet sizes of the test range. The best combustion performance was observed when droplet size, spraying pressure and oil temperature were 73$\mu\textrm{m}$, 2.35MPa and 70$^{\circ}C$ producing CO2 of 13.1%, CO of 13ppm and flue gas temperature of 250$^{\circ}C$ in A oil combustion For B oil, it was100$^{\circ}C$, 2.35MPa, 52$\mu\textrm{m}$, producing CO2 of 10ppm and flue gas temperature of 260$^{\circ}C$. In general, it appeared that better combustion results were observed in the smaller droplets produced burner condition.

  • PDF

A Study on the Development of $CO_2$ Recycle Oxy-Fuel Combustion Heating System ($CO_2$ 재순환형 산소연소 가열시스템 개발에 관한 연구)

  • Jeong Yu-Seok;Lee Eun-Kyung;Go Chang-Bok;Jang Byung-Lok;Han Hyung-Kee;Noh Dong-Soon
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2006.05a
    • /
    • pp.412-419
    • /
    • 2006
  • An Experimental study was conducted on $CO_{2}$ recycle combustion heating system using pure oxygen instead of conventional air as an oxidant, which is thereby producing a flue gas of mostly $CO_{2}$ and water vapor($H_{2}O$ and water vapor($H_{2}O$) and resulting in higher $CO_{2}$ concentration. The advantages of the system are not only the ability to control high temperatures characteristic of oxygen combustion with recycling $CO_{2}$ but also the possibility to reduce NOx emission in the flue gas. A small scale industrial reheating furnace simulator and specially designed variable flame burner were used to characterize the $CO_{2}$ recycle oxy-fuel combustion, such as the variations of furnace pressure, temperature and composition in the flue gas during recycle. It was found that $CO_{2}$ concentration in the flue gas was about 80% without $CO_{2}$recycle. The furnace temperature and pressure and pressure were decreased due to recycle and the NOx emission was also reduced to maintain under 100ppm.

  • PDF

Combustion Characteristics and Application of Cyclon Combustor

  • Chae, J.O.;Xu, F.Z.;Yu, J.;Moon, S.I.;Kim, K.Y.
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.82-89
    • /
    • 2001
  • This paper concerns lean gas cyclone combustion system adopting distributed inlets with different velocity to promote ignition and burnout properties. Detailed temperature measurements have been achieved under different operating conditions and flue gas compositions and NOx have been measured. Experimental results show that cyclone combustor provided increasing combustion stability and reduction NOx emission level to negligible level.

  • PDF