• 제목/요약/키워드: Flue gas

검색결과 606건 처리시간 0.03초

습식 배연탈황설비용 습분제거기 포집효율 평가 (Collection Efficiency of a Mist Eliminator for Wet Flue Gas Desulfurization)

  • 김문원;육세진;류태우
    • 한국입자에어로졸학회지
    • /
    • 제14권3호
    • /
    • pp.73-80
    • /
    • 2018
  • Recently, there has been much research on the effect of ultrafine dust on human body with increasing interest in the ultrafine dust. In the Republic of Korea, there are many old thermal power plants, and the amount of ultrafine dust emitted from the thermal power plants is reported to be about 14% of the total amount of domestic fine dust. Therefore, the amount of fine dust from the flue gas desulfurization facility in the thermal power plant needs be reduced. In this study, we made an experimental setup to simulate a flue gas desulfurization facility and analyzed the physical characteristics of the particles passing through a mist eliminator. Experiments were carried out to investigate the collection efficiency of the mist eliminator by using the Arizona Test Dust in a dry environment, and then spraying limestone slurry into the flue gas desulfurization system equipped with the mist eliminator to examine the size and morphology of limestone particles upstream and downstream of the mist eliminator. Cut-off size of the mist eliminator was formed at about $6{\mu}m$. The result of this study is expected to be helpful for designing an electrostatic precipitator for removing particles passing through the mist eliminator.

연소 배출가스의 유입방식에 따른 백필터를 활용한 흡착/촉매 통합공정 시스템 반응기 내 유동특성 (Flow Characteristics with Inflow-Duct Types in the Reactor of an Integrated Adsorption/Catalysis Process with Bag Filters)

  • 최청렬
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.425-434
    • /
    • 2007
  • An integrated adsorption/catalytic process has been considered to treat dioxin and $NO_x$ simultaneously. The process consists of a cyclone and a reactor with nine bag filters. In this study, numerical analysis has been performed to understand flow characteristics with inflow-duct types in the reactor. To consider flue gas and activated carbon particles simultaneously, Euler-Lagrangian model was employed. Fundamental flow patterns of flue gas and activated carbon particles, pressure distribution and distribution of activated carbon have been obtained from the numerical analysis. Also trace length and residence time of flue gas, residence time of activated carbon particles have been calculated directly. Flow patterns of flue gas and activated carbon particles in the reactor were very complicated and they moved along very various paths. Therefore, their residence time in the reactor was also various. The flow characteristics in the reactor were strongly influenced by inflow-duct types. The results obtained would be effectively used to estimate the removal efficiency in the reactor once the residence time is combined with the reaction equation.

중형폐기물 소각시설의 수은, 납, 비소, 셀렌 배출특성 (Characteristics of Hg, Pb, As, Se Emitted from Medium Size Waste Incinerators)

  • 이한국
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.8-18
    • /
    • 2006
  • The aim of this study is to evaluate the emission characteristics of mercury, lead, arsenic, and selenium from medium size municipal solid waste incinerators(MSWIs) in Korea. The concentrations of mercury, lead, arsenic, and selenium emitted from medium size MSWI stack were $2.67\;{\mu}g/Sm^3,\;0.38\;mg/Sm^3,\;1.33\;{\mu}g/Sm^3,\;0.28\;{\mu}g/Sm^3$, respectively. The concentration levels of mercury, lead, arsenic in flue gas from medium size MSW incinerator stacks selected were nearly detected under the Korea criteria level. Removal efficiencies of mercury, lead, arsenic, and selenium in waste heat boiler(WHE) and cooling tower(CT) were $90.36\%,\;69.76\%,\;43.04\%,\;40.64\%$, respectively. In general, the removal efficiencies of mercury and lead in WHE were higher than those of arsenic and selenium in WHE. Emission gas temperature reduction from waste heat boiler(WHB) and cooling tower(CT) can control mercury and lead of medium size MSWIs. To evaluate the relationship between mercury, lead, arsenic, selenium of fly ash and those of flue gas, it was carried out to correlation analysis of each metal concentration in the fly ash and in the flue gas from medium size MSWIs. From the correlation analysis, the coefficients of mercury, lead, arsenic, and selenium were 0.61, -0.38, 0.87, 0.28, respectively. The results of correlation analysis revealed that it should be highly positive to the correlation coefficients of mercury and arsenic in the fly ash and those of the flue gas emitted from medium size MSWIs. As it were, the concentrations of mercury and arsenic of flue gas from medium size MSWIs are high unless mercury and arsenic in fly ash are properly controlled in dust collection step in medium size MSWIs. It was also concluded that mercury, lead, arsenic, and selenium from MSWIs stacks could be controlled by waste heat boiler(WHE) and dust collecting step in medium size MSWIs.

불활성 가스계 혼합소화약제의 n-Heptane 불꽃소화농도 및 배가스 조성 (Flame Extinguishing Concentrations and Flue Gas Compositions of n-Heptane by Mixed Inert Gas Agents)

  • 김재덕;김영래;홍승태;이성철
    • 한국화재소방학회논문지
    • /
    • 제16권3호
    • /
    • pp.77-83
    • /
    • 2002
  • 질소, 아르곤, 이산화탄소와 같은 불활성가스 및 이들의 혼합물을 소화약제로 하여 n-Heptane을 연료로한 cup-burner test 장치에서 불꽃소화농도와 연소시 배가스의 조성을 측정하였다. 이성분 불활성가스계 혼합소화약제의 소화농도는 혼합물의 구성비를 이용한 모델에 의해 잘 예측됨을 알 수 있었다. 불활성 가스계 혼합 소화약제에 의한 소화작용에 있어서 혼합가스의 평균비중이 클수록 소화 성능이 우수하였다. 또한 밀폐된 공간의 구조가 소화에 영향을 미칠 수 있음을 확인하였다. 연소시 배가스 중 이산화탄소 조성은 사용하는 소화약제의 양이 증가할수록 감소하였다. 일산화질소 발생은 소화약제의 질소 함량과는 상관이 없으며 공기유량을 크게 하여 불꽃을 크게 했을 때 검출되었다.

국내 무연탄 발전소 혼소율 변화에 따른 탈황 특성 연구

  • 김정유;박대영;이재헌;문승재
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.84-87
    • /
    • 2008
  • The sulfur oxides is one of important materials to come about air pollution at thermal plant consuming fossil fuel. The several flue gas desulfurization equipments are installed and operated to decrease sulfur oxides. The flue gas desulfurization of our thermal plant is designed for optimizing flue gas desulfurization technical development and research by Korea Electric Power Research Institute. We operate this desulfurization equipment. Now, our country imports nearly 97 percentage of the energy source and competes with the world for the energy because of the rise of raw materials cost. The fuel cost decrease of power plants is the most important factor of the operation. The fuel used in the experiment is the domestic anthracite from Kangwon Taeback and the bituminous coal from Russia,Taldinsky Mine. This Study is experimental investigations of desulfurization characteristics for domestic anthracite power plant by increasing bituminous coal. We surveyed possible parameters and conducted the performance about desulfurization equipment in Y.D thermal power plant.

  • PDF

왕겨 소각로 배연가스 이용을 위한 미세죠류 배양 조건 확립 (Microalgal Culture Conditions for Utilization of Flue Gas from Rice Husk Incinerator)

  • 박승제;조성호;이진석;정용섭
    • Journal of Biosystems Engineering
    • /
    • 제24권1호
    • /
    • pp.9-18
    • /
    • 1999
  • This study was performed to investigate the optimum microalgal culture conditions using flask culture and to find the feasibility of using the flue gas of the rice husk incinerator for cultivating the microalgae. The optimum initial pH of media was 4.5 for the microalgae culture, and the intermittently illuminated culture was more effective than the continuous illuminated culture. Thus, the balance between photosynthesis and formative metabolism must be considered thoroughly to cultivate microalgal cells. The optimum CO2 concentrations were in the range of 7 to 10%, and the optimum temperature was about 35$^{\circ}C$ in both the daytime and the nighttime for the culture. When flue gas of the rice husk incinerator was applied to the microalgae culture using stirred photobioreactor, the dry cell weight was 0.026 g dry biomass/hr$.$l. The results obtained in experiments indicated that the flue gas was effective for microalgae culture without any limitations.

  • PDF

고효율 응축형 열교환기 개발에 관한 연구 (A study on the development of the high efficiency condensing heat exchanger)

  • 이금배;박상일;박준태
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.589-601
    • /
    • 1997
  • A computer simulation program of a high efficiency condensing heat exchanger is developed. The flue gas flows outside bare tube bundles both in strong cross flow and in weak counter flow and the cooling water inside the tubes. Condensing heat exchangers achieve high efficiency by reducing flue-gas temperatures to a level at which most of the water vapor in the flue gas is condensed and the latent heat associated with phase change of the water is recovered. The computer model has been verified by comparison with measured data. To verify the model, heat transfer coefficient was adjusted, along with the mass transfer diffusion coefficient and pressure drop coefficient, to achieve agreement between predicted and measured data. The efficiencies of heat exchanger increase 2.3 ~ 8.1% by condensations of 6.3 ~ 62.6% of the water vapor in the flue gas.

배기가스 처리용 양방향 펄스 전원 (Bidirectional pulse generator for removal of flue gas)

  • 박정호;고광철;강형부
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.233-236
    • /
    • 1997
  • An investigation has been made of the various plasma chemistry reactions that occur in the corona discharge of an electrostatic precipitator operating in a typical flue gas. As the results of investigation, sulphur dioxide is removed principally by reactions with OH radicals to produce sulphuric acid, while nitrogen oxides are removed principally by reduction via the N radical to molecular nitrogen. If electrostatic precipitator\ulcorner used for flue gases are operated with positive voltages instead of negative dc voltages, there are significant reductions in the emission of the undesirable gases SO$_2$, NO, and NO$_2$. Thus, in this paper we design the bidirectional pulse generator for removal of flue gas, where the pulse width is more than 50[nsec] and the maximum output voltage is more than 100[kVl.

  • PDF

350 kW(300,000 kcal/h)급 우드 펠렛 보일러 운전 특성 및 성능 평가 (Performance Test and Flue Gas Characteristics of a 350 kW Wood Pellet Boiler)

  • 김종진;강새별
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.167-171
    • /
    • 2009
  • We conducted performance test of a 350 kW class wood pellet boiler installed at a dormitory whose total area is $1,354\;m^2$. The maximum heating capacity of the boiler is 350 kW(300,000 kcal/kg). The wood pellet boiler consists of 3 parts; boiler, hot water storage tank and wood pellet storage tank. In testing the boiler, we shut off hot water utility supply and open up floor heating water system in order to measure exact value of the heating output of the wood pellet boiler. To determine the efficiency and heating output of the wood pellet boiler, we measured mass flow rate of wood pellet, the lower heating value(LHV) of the wood pellet, mass flow rate and temperature of water for floor heating and so on. We measured the mass flow rate of fuel, wood pellet with respect to rotational speed of auger, wood pellet feeding screw. We also measured the flue gas concentration of the wood pellet boiler by using a gas analyser. The result shows that the efficiency of the wood pellet boiler is 80.6% based on lower heating value at 124 kW of heating output. At this condition, O2 concentration of the flue gas is 6.0%, CO and NOx concentrations are 85 and 102 ppm.

  • PDF

연소배가스로부터 가스상 수은 처리기술 (Gas-Phase Mercury Control Technology from Flue Gas)

  • 이시훈
    • 에너지공학
    • /
    • 제12권2호
    • /
    • pp.65-73
    • /
    • 2003
  • 국내의 HAPs(Hazardous Air Pollutants)중 수은은 아직까지 관심의 대상이 아니지만 머지않아 문제가 될 것으로 예측된다. 본 논문에서는 현재 국내외의 배가스 수은 배출현황과 처리기술에 대해 요약하였다. 미국을 중심으로 구미 각국에서는 대기분야의 연구개발이 수은에 집중되고 있다. 수은 제어 프로그램은 크게 두 가지로 방향을 잡고 있다. 하나는 기존의 WFGD(Wet Flue Gas Desulfurization)를 이용하여 수은을 산화시켜 제거하는 방법이며 다른 하나는 수은 제거효율이 높은 활성탄 또는 다른 novel sorbent (low-cost sorbent)를 사용하는 방법이다. 선진국에서는 2007년에 발전소 수은 제거설비 설치가 의무화 될 것이다. 본 논문에서 제공하는 자료는 국내에서 발전소 수은 규제가 시작될 때 효과적으로 적용될 수 있을 것이다.