• Title/Summary/Keyword: Flowrate Measurement

Search Result 42, Processing Time 0.023 seconds

Investigation for Streamflow Measurement of Small Stream using Dilution Discharge Method during Low Flow Season (갈수기 소하천에서 희석유량법을 이용한 유량측정의 적용성 검토)

  • Kim, Gee Hyeong;Kim, Jeongkon;Lee, Sanguk
    • Journal of Wetlands Research
    • /
    • v.8 no.4
    • /
    • pp.59-67
    • /
    • 2006
  • In this study, dilution discharge method to measure streamflow using water quality data at small streams during low flow season was applied and compared with the conventional method using flowmeter combined with cross-sectional measurement. Streamflow were measured using both methods in Dal-cheon around Naesok Wastewater Treatment Plant located in Boeun, Chugbuk. This stream is reported to suffer from excessive algal growth in spring. An average flowrate difference of $0.004m^3/sec$ was obtained between the two methods. Once further tested for various conditions, the simple water quality method suggested in this study can be used effectively to estimate stream flowrates during low flow seasons where no measuring facilities such as weirs and flowmeters are not available or water depths are too small to measure flow velocities and exact cross-sections.

  • PDF

Cooling Characteristic Analysis of Transformer's Radiator (변압기 냉각 특성 해석)

  • Kim, Hyun-Jae;Yang, Si-Won;Kim, Won-Seok;Kweon, Ki-Yeoung;Lee, Min-Jea
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1920-1925
    • /
    • 2007
  • A transformer is a device that changes the current and voltage by electricity induced between coil and core steel, and it is composed of metals and insulating materials. In the core of the transformer, the thermal load is generated by electric loss and the high temperature can make the break of insulating. So we must cool down the temperature of transformer by external radiators. According to cooling fan's usage, there are two cooling types, OA(Oil Natural Air Natural) and FA(Oil Natural Air Forced). For this study, we used Fluent 6.2 and analyzed the cooling characteristic of radiator. we calculated 1-fin of detail modeling that is similar to honeycomb structure and multi-fin(18-fin) calculation for OA and FA types. For the sensitivity study, we have different positions(side, under) of cooling fans for forced convection of FA type. The calculation results were compared with the measurement data which obtained from 135.45/69kV ultra transformer flowrate and temperature test. The aim of the study is to assess the Fluent code prediction on the radiator calculation and to use the data for optimizing transformer radiator design.

  • PDF

Design and Fabrication of an Electromagnetic Flowmeter (전자기유량계의 설계 및 제작)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1385-1392
    • /
    • 2003
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The developed EMF was designed as the 100 mm nominal diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. In order to obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF. For the characterization of the developed EMF, the uncertainty of calibrator was estimated within $\pm$0.5 %. The evaluation procedure of the uncertainty followed the ISO Guide to the Expression of Uncertainty in Measurement. It was found that the flow signals between the electrodes were about $\pm$60-$\pm$300$\mu$V, which were sufficient for the discrimination of flowmeter and the protection of noise. The test results against the calibrator showed the good linearity in the range of 3 ㎥/h and 70 ㎥/h. A commercialized design of the EMF based on the current study will be technically more competitive in domestic and foreign market.

A Study on Performance Change of Gas Injector with Ambient Temperature Environment (주변 온도환경 변화에 따른 가스 인젝터 성능 변화에 대한 연구)

  • Kim, Ji-Yoon;Yang, Jeong-Jik;Kim, Jin-Ho;Seo, Ii-Won;Lim, Jong-Wan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.18-23
    • /
    • 2018
  • This study tries to analyze the injection amount of injector according to the external environment temperature of CNG vehicle. Especially, We investigated the effect of low temperature environment on gas injector performance by measuring the variation of injection amount under the same conditions as in coldstart condition. This experimental compared two products with different spring characteristics. The experimental device consist of a fuel supply unit, a flowrate measurement unit, a temperature chamber, and an injector control unit (ECU). According to the test result, the initial injection amount of the injector is increased in the low temperature environment and the needle opening time is delayed according to the change of the spring length.

Thrust Estimation Acting on Rotor of LOX Pump for Liquid Rocket Engine (액체로켓엔진용 산화제펌프 회전체의 하중 예측)

  • Kim, Dae-Jin;Choi, Chang-Ho
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.6
    • /
    • pp.98-104
    • /
    • 2015
  • Excessive thrust acting on the rotor of pump can cause the damage of pump or the decrease of pump lifetime. Therefore, for ensuring the safety of LOX pump of a liquid rocket engine, the thrust of pump rotor is estimated by similarity tests. Axial thrust is indirectly measured by an axial thrust measurement unit positioned outside pump. Radial thrust is calculated based on pressure distribution of volute scroll. As a result, axial and radial thrust are increased when the flowrate of pump decreases. However, both thrusts do not affect the stability of pump rotor since their values are not large.

Axial Thrust Measurement of Fuel Pump for 75-ton Class Rocket Engine (75톤급 로켓엔진용 연료펌프의 축추력 측정)

  • Kim, Dae-Jin;Hong, Soon-Sam;Choi, Chang-Ho;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.8-13
    • /
    • 2010
  • An effective control of the axial thrust of a turbopump is one of the critical issues for obtaining its operational stability. Axial thrusts of the fuel pump for the 75-ton class rocket engine under development were measured with water as a test propellant at a room temperature. According to the test results, the axial thrust of the fuel pump seemed to satisfy the axial force condition of its bearing. Also, the thrust was increased as a whole when the flowrate of the pump was decreased. Furthermore it was found that the thrust and the leakage flowate were modified when the gaps between the floating ring seals and the impeller were changed.

Analysis of the wastewater characteristics variation in sewerage by rehabilitation (관거 정비에 따른 하수발생특성 분석)

  • Jung, SiMon;Park, InHyeok;Park, JungHa;Ha, SungRyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.287-293
    • /
    • 2009
  • The study involved the measurement of flowrate and BOD in the Yeoju area and analyzed annual sewerage data by the I/I analysis technique which is common in Korea. The results of this study are as follows. The I/I for the Y-1 site before maintenance and after the completion of the whole process was reduced from 62% to 16.1% respectively with respect to maximum sewage flow per day. The average quality of water increased. The study measured the Y-2 site from a point of time corresponding to an 80% process rate and its I/I rate went up a little from 8.5% to 11.5%. At the Y-3 site, the I/I rate went up a little from 11% to 13.8%, while little change was noted in the average water quality. At the Y-4 site, the I/I rate was reduced from 43% to 16.9% and its average water quality went up. At the Y-5 site, the I/I quantity went up a little however its average water quality also went up largely. Therefore, it was concluded that the Y-5 site showed great improvement due to the sewer pipe maintenance.

An experimental study on the effect of deterioration of drainage system on tunnel structures (배수시스템 수리기능저하가 터널구조물에 미치는 영향에 대한 실험적 연구)

  • Kwon, Oh-Yeob;Shin, Jong-Ho;Yang, Yu-Hong;Joo, Eun-Jung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.970-979
    • /
    • 2006
  • Construction of underground structure requires higher standard of planning and design specifications than in surface construction. However, high construction cost and difficult working environment limit design level and construction quality. One of the most sensitive factors to be considered are infiltration and external pore-water pressures. Development of pore-water pressure may accelerate leakage and cause deterioration of the lining. In this paper, the development of pore-water pressure and its potential effect on the linings are investigated using physical model tests. A simple physical equipment model with well-defined hydraulic boundary conditions was devised. The deterioration procedure was simulated by controlling both the permeability of filters and flowrate. Development of pore-water pressure was monitored on the lining using pore pressure measurement cells. Test results identified the mechanim of pore-water pressure development on the tunnel lining which is the effect of deterioration of drainage system. The laboratory tests were simulated using coupled numerical method, and shown that the deterioration mechanism can be reproduced using coupled numerical modelling method.

  • PDF

Optimal Design of Orifice typed Distribution Channel using Step Method Program (Step method 프로그램을 이용한 orifice 분배수로의 최적 설계에 관한 연구)

  • Park, No-Suk;Park, Sangcheol;Kim, Sung-soo;Lee, Seonjoo;Jeong, Nam-Jeong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.691-700
    • /
    • 2006
  • This study conducted to optimize the design and operation of orifice typed distribution channels which were generally constructed to link the rapid mixing process and flocculation/sedimentation basin. To accomplish the goal of this study, programming step method using FORTRAN 90, was applied it to simulate the performance of existing distribution channel in the selected S DWTP (Drinking Water Treatment Plant). The proposed step method program was validated in terms of the feasibility with comparison between the measurement and prediction value in each orifice. From the evaluation results of the current conditions with the design and operation, it was revealed that the existing gradient of the tapered channel is not appropriate. Also, we suggested that in the case of the inlet width being 3.5m, reducing the downstream width by about 0.5m would make more equitable distribution flow in the channel. Consequently, dealing with various conditions of the design and operation with distribution channel, we could conclude that for the parallel typed channel, as the width is wider and the diameter of orifice is smaller, the more equitable distribution occur. In addition, the inlet flowrate and the number of orifice can affect the flow velocity in the channel.

Direct Bio-regeneration of Nitrate-laden Ion-exchange Resin (질산성질소에 파과된 이온교환수지의 생물학적 직접 재생)

  • Nam, Youn-Woo;Bae, Byung-Uk
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.777-781
    • /
    • 2013
  • Ion-exchange technology is one of the best for removing nitrate from drinking water. However, problems related to the disposal of spent brine from regeneration of exhausted resins must be overcome so that ion exchange can be applied more widely and economically, especially in small communities. In this background, a combined bio-regeneration and ion-exchange system was operated in order to prove that nitrate-laden resins could be bio-regenerated through direct contact with denitrifying bacteria. A nitrate-selective A520E resin was successfully regenerated by denitrifying bacteria. The bio-regeneration efficiency of nitrate-laden resins increased with the amount of flow passed through the ion-exchange column. When the fully exhausted resin was bio-regenerated for 5 days at the flowrate of 30 BV/hr and MLSS concentration of $125{\pm}25mg/L$, 97.5% of ion-exchange capacity was recovered. Measurement of nitrate concentrations in the column effluents also revealed that less than 5% of nitrate was eluted from the resin during 5 days of bio-regeneration. This result indicates that the main mechanism of bio-regeneration is the direct reduction of nitrate by denitrifying bacteria on the resin.