장기 안정성을 고려한 경질유 유량표준장치 불확도 평가 (Long Term Stability of Uncertainty Analysis of Light Oil Elow Standard System)

  • 임기원;최종오
    • 대한기계학회논문집B
    • /
    • 제29권10호
    • /
    • pp.1130-1138
    • /
    • 2005
  • A national standard system for the petroleum field has been developed to calibrate and test the oil flow meters in Korea. The operating system and the uncertainty of the system were evaluated by the peer reviewers of foreign national metrology institutes in 2002. Since the characteristics of the system might be changed by time, the uncertainty of the system is reevaluated with the consideration of the long term stability of the system. It is found that the system has a relative expanded uncertainty of 0.048 $\%$ in the range of $15\~120\;m^3/h$. According to the uncertainty budget, the uncertainties of the fluid density and the final mass measurement, which are temperature dependent, contribute about $94\%$ of the total uncertainty in the oil flow standard system

레이저 유도 형광법(LIF)을 이용한 버너 화염의 NO 농도측정에 관한 연구 (A Study on Measurement of NO Concentrations in Burner Flames by LIF)

  • 박경석;김성욱
    • 한국분무공학회지
    • /
    • 제7권4호
    • /
    • pp.42-49
    • /
    • 2002
  • In this study, quantitative measurement of nitric oxide concentration distributions were investigated in the laminar CH4/O2/N2 premixed flame by laser-induced fluorescence (LIF). The NO A-X (0,0) vibrational band around 226nm was excited using a XeCl excimer-pumped dye laser. Selecting an appropriate NO transition minimizes interference from Rayleigh scattering and O2 fluorescence. The measurements were taken in CH4/O2/N2 premixed flame with equivalence ratios varying from $1.0{\sim}1.6$, and a fixed flowrate of 5slpm. NO was found to produce primarily between an inner premixed and an outer nonpremixed flame front, and total NO concentration is raised when equivalence ratios increase. These results suggest that prompt NO is likely to contribute to NO formation in CH4/O2/N2 premixed flame. Furthermore, this trend was well matched with previous works.

  • PDF

코리올리 유량계를 이용한 정밀유량측정에 관한 연구 (A Study of the Precise Flow Measurement using Coriolis flowmeter)

  • 김인태;조대기;정민제;이재원;서혁;유명종
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제30회 춘계학술대회논문집
    • /
    • pp.61-64
    • /
    • 2008
  • 액체추진제 추력기의 경우, 성능평가를 위해 진공연소시험이 필수적으로 요구되며 이때 공급되는 추진제의 유량이 비추력 계산시 중요한 영향을 미치는 인자가 된다. 본 논문에서는 정밀 유량측정에 대한 기초연구로서, 코리올리 유량계를 이용하여 모의추진제인 DIW를 사용한 수류시험을 수행하였으며 연속모드 및 펄스모드 각각에 대해 결과분석이 이루어졌다. 마지막으로 해외연소시험 데이터와의 비교를 통해 수류시험 결과와의 검증을 확인하였다.

  • PDF

코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구 (An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter)

  • 임기원;이완규
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.

로켓엔진용 연료펌프의 축추력 측정 (Axial Thrust Measurement of Fuel Pump for Liquid Rocket Engine)

  • 김대진;홍순삼;최창호;김진한
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.358-362
    • /
    • 2005
  • 축추력의 효과적인 제어는 터보펌프 개발의 핵심 기술 중 하나이다. 현재 개발 중인 액체로켓엔진용 연료펌프의 안정성을 입증하기 위해 축추력 측정 장치를 개발하고 수류 시험을 실시하였다. 시험 결과, 연료펌프는 설계 유량에서 펌프 베어링의 축방향 하중 요구 조건을 만족하였다. 또한 이차 유로의 오리피스를 통해 연료펌프에 대한 축추력 제어가 가능한 것을 확인하였다.

  • PDF

소형 코리올리 질량 유량계의 개발 (Development of Small Size Coriolis Mass Flowmeter)

  • 임기원;지정근
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

헬리콥터용 보조동력장치 고공성능에 관한 실험적 연구 (Experimental Research on the Altitude Performance of an Auxiliary Power Unit for Helicopters)

  • 김춘택;차봉준
    • 한국유체기계학회 논문집
    • /
    • 제15권5호
    • /
    • pp.20-26
    • /
    • 2012
  • An APU(Auxiliary Power Unit) for helicopters has been developed in Korea and tested at the AETF(altitude engine test facility) in KARI(Korea Aerospace Research Institute) for the purpose of the military qualification. A cell correlation test was performed before the official test, and the results are within the tolerance. The APU has the capability of supplying electric power as well as compressed air to the helicopters. It was tested at bleed extraction conditions, electric power extraction conditions, and maximum continuous concurrent power conditions within the entire helicopter flight envelop. Some special test equipments were implemented for the measurement of air flowrate, electric power and so on. The tests were successfully performed and their results satisfy the requirements of the helicopters.

가시화 기법을 이용한 열전소자 냉장고의 유동최적화에 관한 연구 (A Study on flow optimization of thermoelectric refrigerator using visualization technique)

  • 김보라;이창제;정연호;황광일;조경래
    • 한국가시화정보학회지
    • /
    • 제19권1호
    • /
    • pp.94-99
    • /
    • 2021
  • In order to increase the efficiency of thermoelectric refrigerators using the Peltier effect, it is necessary to optimize the distribution of the flow of cold air from the fan. In this study, the flow flowing upwards and downwards while changing the area of the flow path was visualized using the PIV technique for the control of cold air in a thermoelectric refrigerator. From these results, the flow rate according to the change in the area of the flow path was confirmed, and design criteria for optimizing the distribution of cold air flowing to the top and bottom of the refrigerator were suggested.

저전도율 유체 측정에서 소형 전자기유량계의 신호 특성 (Flow Signal Characteristics of Small Scale Electromagnetic Flowmeter in Low Conductivity Fluid Measurement)

  • 임기원;정성수
    • 대한기계학회논문집B
    • /
    • 제40권9호
    • /
    • pp.613-620
    • /
    • 2016
  • 유체의 전도율(conductivity)이 전자기유량계의 특성에 미치는 영향을 평가하기 위해 소형 전자기 유량계를 설계 제작하였다. 유량계의 측정관(measuring tube)은 $4mm{\times}3mm$의 직사각형 단면을 가지며 길이는 9 mm이다. 전극은 직경이 1.5 mm인 점전극과 단면이 $2mm{\times}3mm$인 면전극으로 설계하였다. 코일의 열 발생에 영향을 미치는 자화주파수, 회전수 및 굵기를 변화시키면서 최적값을 찾았다. 최적화된 측정관은 자속밀도(magnetic flux density) 0.04 T (400 gauss)를 발생시키며 안정되고, 선형적인 유량신호를 얻을 수 있었다. 유량계를 특성을 평가하기 위해 중량식 유량계 교정 장치를 제작하였다. 유동율 범위는 최대 $1.17{\times}10^{-5}m^3/s$(700 cc/min)이며 ISO규격에 따라 유동량 결정의 불확도를 평가하였으며 크기는 0.06 % 이내이었다. 유체의 전도율은 $3-11{\mu}S/cm$ 사이에서 조절하였다.

발사체 탱크 추진제 수위 측정시스템 감지부 선행연구 (Preceding Study on the Sensing Part of Level Measurement System of Launch Vehicle Propellant Tanks)

  • 신동순;이응신;고현석;조인현
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.54-57
    • /
    • 2009
  • 차기 한국형 발사체의 추진제 수위 측정시스템은 적용하는 추진제의 극저온 환경 및 유량제어 특성을 고려하여 연속적인 정전용량 값 출력이 가능한 정전용량형이 채택될 예정이다. 현재 정전용량형 신호 감지방식은 2전극과 3전극 방식이 있으나 본 연구에서는 측정 정확도를 고려하여 모든 유체에 적용 가능한 3전극 방식을 채택하였다. 본 논문에는 3전극 방식의 감지원리에 대한 고찰 결과 및 감지부의 형상 변화가 정전용량값에 미치는 영향에 대한 분석 결과, 추진제 탱크 상단의 감지부 설치 위치에 따른 신호감지 영향을 확인하기 위하여 시뮬레이션 프로그램을 활용한 결과가 정리되어 있다. 본 연구에서 얻어진 자료는 실제 탱크 내의 추진제 수위 측정시스템 감지부 설계 및 제작에 활용 가능하다.

  • PDF