• Title/Summary/Keyword: Flowrate Measurement

Search Result 42, Processing Time 0.02 seconds

A Study on the Measurement Uncertainty of Flowmeter Calibrator (유량계 교정장치의 측정불확도에 관한 연구)

  • Im, Gi-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

AN INVERSTIGATION OF THE DYNAMIC ERRORS OF THE REMOTE-INSTANTANEOUS FLOWRATE MEASUREMENT DUE TO PARAMETER CHANGES

  • Kim, Do-Tae;Yokota, Shinichi;Nakano, Kazuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1712-1717
    • /
    • 1991
  • The paper describes estimation errors of unsteady flowrate measurements due to parameter changes in a quasi-remote instantaneous flowrate measurement method (abbreviate as QIFM) and an instantaneous flowrate measurement method using two points pressure measurements (abbreviate as TPFM). By introducing error performance index, the influence of parameter changes on the accuracy, and dynamic response of the estimated unsteady flowrate are evaluated. Of four parameters, the variation of the length of the pipeline and speed of sound produce large errors in the estimated unsteady flowrate during transient periods. The effect of kinematic viscosity of the working fluid(oil) is relatively insensitive in unsteady flowrate estimation.

  • PDF

An approach for remote measurement of instantaneous flowrate by making use of hydraulic pipeline dynamics

  • Yokota, Shinichi;Kim, Dotae;Nakano, Kazuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.749-754
    • /
    • 1989
  • This paper describes a remote measurement method for estimating unsteady flowrate through a pipeline. By this method, instantaneous flowrate at the remote location along a pipeline (distance L) from flowmeters is measured by making use of dynamic characteristics between two cross sections of the circular pipeline. Using this method, instantaneous flowrate is accurately measured at a location where it is difficult to setup flowmeters. The estimated flowrate waveforms by the method are compared with directly measured ones by cylindrical choke-type instantaneous flowmeter. The validity of the method is established.

  • PDF

A Study on the Performance Characteristics of Float Type Flow Meter (부자식 유량계의 성능특성에 관한 연구)

  • 김춘식;김경근;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.339-347
    • /
    • 1985
  • Precise measurement of flowrate is considered as an important measuring factor in mechanical and chemical experiment. Although there are many methods to measure flowrate, Float type flowmeter is widely used because of its easy attachment to piping and high measuring precision. To design the precise float type flowmeter, much design information such as tapered-tube dimensions, float size, float shape and float material is required. In this paper, fundamental design theory for float type flowmeter according to the given flowrate range is suggested and compensation coefficients of volumetric and weight flowrate for water, R-113 and air are calculated.

  • PDF

A Study on the Effect of Flowrate on the Drop size from Two-Phase Coaxial Nozzle (이상류 동축노즐의 액경에 미치는 공급유량의 영향에 관한 연구)

  • 윤석주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.5
    • /
    • pp.933-942
    • /
    • 1992
  • The effects of the folwrate on the dropsize from the two-phase coaxial nozzle are investigated by using the direct photographic method and the empirical equation is obtained. For the photography, the light source which the life time is the order of 100ns is fabricated and the lens is the zoom lens which has the MICRO function with a teleconvertor. The distillated water and the compressed air of the surrounding temperature are injected and atomized. For the purpose of the exact adjustment and measurement of the flowrates, the two rotameters are used. As a result of this study, the sauter mean diameter of droplets has a tendency for a logarithmic function with air flowrate and for a exponential function with water flowrate.

Fan Performance Test with Automatic Control and Measurement (자동제어계측을 이용한 송풍기 성능시험)

  • Choi, Young-Seok;Kim, Jin-Kwon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.373-378
    • /
    • 2003
  • In this paper, build up of fan performance tester in KITECH was introduced. The fan tester was set up based on AMCA standards 210-99, ANSI/ASHRAE 51-1999 with maximum flowrate within $1000\;m^{3}/min$. Both of inlet and outlet chamber setup with multiple nozzles described in AMCA 210 were established. The development of fully automatic control and measurement system are described. With this system, the accuracy of fan performance test can be maintained through the various flowrate and the uncertainty can be reduced.

  • PDF

A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters (2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구)

  • Choi Jong Oh;Lee Woan Kyu;Lim Ki Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.

A Feasibility Study of Simultaneous Measurement of Gas-Liquid Two-Phase Flowrate and Quality with a Sharp-Edged Orifice (차압유량계를 이용한 기액 2상유량 및 건도의 동시측정 가능성에 관한 연구)

  • 이상천;오홍의;김중엽
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.335-342
    • /
    • 1986
  • The feasibility of simultaneous measurement of gas-liquid tow-phase flowrate and quality with a sharp-edged orifice has been investigated. Instantaneous pressure drop curves were monitored for various combinations of gas and liquid flowrates in the bubbly flow regime and some statistical properties of the curves were calculated. The time-averaged value of pressure drop increases with increasing gas and liquid flowrate, whereas the mean amplitude and the intensity of fluctuation monotonically increase as void fraction becomes larger in the flow regime. The statistical furctions for the instantaneous curves indicate a consistent pattern throughout the flow regime and the probability density function, which as a single-peaked and symmetrical distribution, is well predicted by the Gaussian distribution function. The results indicate that simultaneous determination of two-phase flowrate and quality may be possible based upon the statistical analysis of instaneous pressure drop curves measured in a sharp-edged orifice.

Evaluation of Thermodynamic Method for Pump Performance Measurement (열역학적 방법을 이용한 펌프 운전성능 평가법 검토)

  • Kang, Shin-Hyoung;Kim, Jin-Kwon;Hong, Soon-Sam;Yates, Alex
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.3 s.8
    • /
    • pp.25-30
    • /
    • 2000
  • Thermodynamic method of pump performance measurement calculates pump efficiency and flowrate by measuring fluid temperature increase and pressure rise through the pump. The theory of this method is investigated and precise comparison experiment with classical hydraulic method was conducted to verify the accuracy. Classical hydraulic pump performance measurement results and Yatesmeter results based on the thermodynamic method showed good agreement in measured performance.

  • PDF