• 제목/요약/키워드: Flowrate Control

검색결과 83건 처리시간 0.025초

유압 제어계에서 서보밸브 선형화 방정식의 오차 평가 (Error Evaluation of Linearized Equation for a Servovalve in Hydraulic Control Systems)

  • 김태형;이일영
    • 대한기계학회논문집A
    • /
    • 제27권5호
    • /
    • pp.779-788
    • /
    • 2003
  • This study evaluates the approximation errors of the existing linearized equation for a servovalve nonlinear flowrate characteristic. At first, the errors are evaluated on flowrate/pressure characteristics diagrams. Subsequently, they are investigated with time response simulation results for several hydraulic control systems. To enable systematic evaluation of computational error, the authors propose three kinds of equations with restructured forms of the existing linearized equation. As results of the evaluations, it is ascertained that comparatively good computational accuracy can be achieved with the existing linearized equation when both an operating point for the linearized equation and operating range of the hydraulic system stay near the flowrate axis of the flowrate/pressure characteristics diagram. In addition, the results show that comparatively big computational error may occur when operating range of a hydraulic system stay apart from the flowrate axis of the flowrate/pressure characteristics diagram.

휜 형상 및 유량에 따른 휜-관 현열 열교환기의 전열성능에 관한 연구 (A Study on the Thermal Performance of Fin and Tube Sensible Heat Exchanger according to Fin Geometry and Flowrate)

  • 이민수;전창덕;이진호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.402-407
    • /
    • 2008
  • This study is performed to investigate heat transfer characteristics for thermal performance of fin-and-tube sensible heat exchangers under the low air flowrate according to fin geometry combination and coolant flowrate control. Fins and tubes of samples were separated between front row and rear row. Experiment results are plotted heat transfer rate of each row, heat transfer coefficient and sensible heat ratio against water flowrate control of each row. It is observed that thermal performance can be enhanced by fin geometry combination and water flowrate control of each row under the low air flowrate.

  • PDF

Y형 세대별 정유량 밸브 개발에서의 CFD의 활용 (CFD for Y-type Constant Flowrate Valve Design)

  • 권우철;이병휘
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.488-491
    • /
    • 2004
  • Numerical analysis of the three dimensional turbulent flow field in a complex valve shape is carried out to confirm the flow field whether the designed valve shape is good or not. The simulation of the incompressible flow in a constant flowrate control valve is performed by using the commercial code, FLUENT/UNS 6.0. The results of flow field show the designed valve has some problems, therefore these will be good data for new valve design.

  • PDF

대구 지하철역 제연의 문제점과 대책 II. 배기방식 제연설비의 풍량 (A Numerical Simulation of Smoke Control in Daegu Subway Stations II. Air Flowrate of Extraction System)

    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.105-110
    • /
    • 2003
  • II부에서는 I부에서 3가지 기계제연방식 중에서 가장제연성능이 우수한 것으로 나타난 배기방식의 풍량 0.6∼2.4 ㎥/s와 두 화재크기 200 ㎾와 2 ㎿에 대한 공간내 온도와 연기입자의 분포를 조사하였다. I 부와 동일한 수치법을 동일한 계산영역에 적용한 결과, 배기풍량은 제연성능에 큰 영향을 미치는 것으로 나타났고, 두 화재크기에서 풍량의 증가가 제연성능을 개선하는 비슷한 경향을 보였다. 주어진 조건에서 대피로의 온도를 $60^{\circ}C$ 이하로 유지하기 위해서는 2.4 ㎥/s 이상의 배기풍량이 필요함을 알 수 있었다.

AN INVERSTIGATION OF THE DYNAMIC ERRORS OF THE REMOTE-INSTANTANEOUS FLOWRATE MEASUREMENT DUE TO PARAMETER CHANGES

  • Kim, Do-Tae;Yokota, Shinichi;Nakano, Kazuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.1712-1717
    • /
    • 1991
  • The paper describes estimation errors of unsteady flowrate measurements due to parameter changes in a quasi-remote instantaneous flowrate measurement method (abbreviate as QIFM) and an instantaneous flowrate measurement method using two points pressure measurements (abbreviate as TPFM). By introducing error performance index, the influence of parameter changes on the accuracy, and dynamic response of the estimated unsteady flowrate are evaluated. Of four parameters, the variation of the length of the pipeline and speed of sound produce large errors in the estimated unsteady flowrate during transient periods. The effect of kinematic viscosity of the working fluid(oil) is relatively insensitive in unsteady flowrate estimation.

  • PDF

다구찌 방법을 이용한 시로코 홴의 최적설계에 관한 실험적 연구 (An Experimental Study on the Optimum Design of Sirocco Fan by Using Taguchi Method)

  • 김장권
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.761-768
    • /
    • 1999
  • This paper is studied to find the optimum condition of double-inlet Sirocco fan installed in an indoor PAC for low noise operation by the Taguchi method. The goal of this study is to obtain the best combination of each control factor which results in a desired flowrate of Sirocco fan with minimum variability. In this study, the parameter design of the Taguchi method is adopted for robust design by the dynamic characteristic analysis using orthogonal arrays and S/N ratios. The flowrate measurements are conducted by using a multiple-nozzle-type fan tester according to the orthogonal array L9($3^4$). The results of this study can be summarized as follows ; (i) The optimum condition of control factor is a set of where A is an inner to outer diameter ratio($D_1/D_2$), B is a width to outer diameter ratio($L/D_2$), C is a blade attachment angle(${\theta}$) and D is a number of blade(Z), (ii) The flowrate under the optimum condition satisfies the equation $y=0.0384{\cdot}M$ where M is a signal factor, namely number of revolution. The flowrate performance improves about 7.3% more largely as compared with the current condition, which results in about 35RPM reduction of number of revolution for the target flowrate $18.5m^3/min$, and (iii) The sensitivity analysis shows that the major factors in contribution to flowrate performance are A, B, and D ; the percentage contributions of each control factor are 44.01%(Z), 26.77%($D_1/D_2$) and 20.42%($L/D_2$).

대와류모사를 이용한 연기이동의 연구 I. 제연방식과 배기풍량 (A Study on Smoke Movement by Using Large Eddy Simulation I. Smoke Control Systems and Extraction Flowrate)

  • 박외철
    • 한국안전학회지
    • /
    • 제18권2호
    • /
    • pp.40-45
    • /
    • 2003
  • To evaluate the smoke control systems, the large eddy simulation turbulence model based Fire Dynamics Simulate was applied to a 2m $\times$ 2m $\times$ 2.4m room with an opening. The smoke removal rate was investigated for three different smoke control systems: ventilation, extraction and pressurization. When the opening was closed, the smoke removal rates of the smoke control systems were almost the same as expected. The pressurization system showed a lower smoke removal rate compared with the other two smoke control systems for the room with the opening, and hence the pressurization system might not be efficient for a place with large openings. It was shown that the lower extraction flowrate is, the longer time the ventilation system requires to remove smoke. From these results, the ventilation system is recommended for subway stations where several large openings exist.

Analysis on Torque, Flowrate, and Volumetric Displacement of Gerotor Pump/Motor

  • Yun, Hongsik;Ham, Young-Bog;Kim, Sungdong
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권2호
    • /
    • pp.28-37
    • /
    • 2020
  • It is difficult to analytically derive the relationship among volumetric displacement, flowrate, torque, and rotation speed regarding an instantaneous position of gerotor hydraulic pumps/motors. This can be explained by the geometric shape of the rotors, which is highly complicated. Herein, an analytical method for the instantaneous torque, rotation speed, flowrate, and volumetric displacement of a pump/motor is proposed. The method is based on two physical concepts: energy conservation and torque equilibrium. The instantaneous torque of a pump/motor shaft is determined for the posture of rotors from the torque equilibrium. If the torque equilibrium is combined with the energy conservation between the hydraulic energy of the pump/motor and the mechanical input/output energy, the formula for determining the instantaneous volumetric displacement and flowrate is derived. The numerical values of the instantaneous volumetric displacement, torque, rotation speed, and flowrate are calculated via the MATLAB software programs, and they are illustrated for the case in which inner and outer rotors rotate with respect to fixed axes. The degrees of torque fluctuation, speed fluctuation, and flowrate fluctuation can be observed from their instantaneous values. The proposed formula may provide a better understanding of the design or analysis process of gerotor pumps/motors.

An approach for remote measurement of instantaneous flowrate by making use of hydraulic pipeline dynamics

  • Yokota, Shinichi;Kim, Dotae;Nakano, Kazuo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.749-754
    • /
    • 1989
  • This paper describes a remote measurement method for estimating unsteady flowrate through a pipeline. By this method, instantaneous flowrate at the remote location along a pipeline (distance L) from flowmeters is measured by making use of dynamic characteristics between two cross sections of the circular pipeline. Using this method, instantaneous flowrate is accurately measured at a location where it is difficult to setup flowmeters. The estimated flowrate waveforms by the method are compared with directly measured ones by cylindrical choke-type instantaneous flowmeter. The validity of the method is established.

  • PDF

초임계 추출 공정의 압력 및 유량 제어계 구성 (Design of pressure and flowrate control systems for a supercritical extraction process)

  • 김원철;김홍식;이광순
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.471-475
    • /
    • 1988
  • Pressure and flowrate control systems for a supercritical extraction process are designed and analyzed. To do this, the dynamic model was first set up using the performance equations of control valves, CO2 compressor and the state equation of the supercritical fluid. Using this model, optimum pairs of manipulated and controlled variable which give least steady stat interaction are determined though the relative gain analysis.

  • PDF