• 제목/요약/키워드: Flowing Water Purification

검색결과 29건 처리시간 0.022초

챔버 내측에 스프링형상을 갖는 유수형 자외선 살균장치 시뮬레이션 (Simulation for the Flowing Water Purification with Spring Shape Inside Chamber)

  • 정병균;정병호;이진종;정병수
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.411-416
    • /
    • 2010
  • Interest in application of ultraviolet light technology for primary disinfection of potable water in drinking water treatment plants has increased significantly in recent years. The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics(CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. In this paper, It describe the how to design optimal UV disinfection device for ground water, BWT and rainwater. Spring shape instrument silver coated located in inner side of disinfection chamber. It make lead the active flowing movement target water and maximize disinfection performance. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method, performed simulation and proved satisfied performance.

UV램프를 이용한 유수처리형 살균장치의 설계방법 (Design Method for Flowing Water Purification with UV Lamp)

  • 정병균;이진종;정병호
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.455-460
    • /
    • 2009
  • A number of factors combine to make ultraviolet radiation a superior means of water purification for ground water, rainwater harvesting systems and so on. Ultraviolet radiation is capable of destroying all types of bacteria. Additionally, ultraviolet radiation disinfects rapidly without the use of heat or chemical additives which may undesirably alter the composition of water. In a typical operation, water enters the inlet of a UV lamp and flows through the annular space between the quartz sleeve and the outside chamber wall. The irradiated water leaves through the outlet nozzle. Several design features are combined to determine the dosage delivered. The first is Wavelength output of the lamp, the Second is Length of the lamp - when the lamp is mounted parallel to the direction of water flow, the exposure time is proportional to the length of the lamp, the third is Design water flow rate - exposure time is inversely related to the linear flow rate, the forth is Diameter of the purification chamber - since the water itself absorbs UV energy, the delivered dosage diminishes logarithmically with the distance from the lamp. In this paper, It describe the how to design optimal UV disinfection device for ground water and rainwater. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method manufactured prototype applied to disinfection test and proved satisfied performance.

Flow-3D를 활용한 수질정화체가 설치된 농업용 배수로의 안정성 조사 (Investigation of the Hydraulic Stability of Agricultural Drainage Channels Installed Water Purification Materials by using Flow-3D)

  • 김선주;박기춘
    • 한국농공학회논문집
    • /
    • 제49권5호
    • /
    • pp.3-9
    • /
    • 2007
  • In this study, the effect of the purification materials is analyzed and tested by Flow 3D and Hydraulic model test. Three dimension numerical analysis led from the research that sees abnormal form and the size back of the water purification material conferred the flowing water conduct inside the test channel against the test condition. Comparison it analyzed the flux distribution, a water depth of the channel which establishes the water purification materials the cross section, an interval of the water purification material, a conference with general channel, it change executed. As a result, the cross section ratio of the purification materials against and a flux change from the test which it sees. The interval of the purification materials in order to prevent three dimension that follows in decrease of increase and flux must decide an interval.

자외선램프을 이용한 유수처리장치 설계 시뮬레이션 (Simulation Method for the Flowing Water Purification with UV Lamp)

  • 정병호;이강연
    • 조명전기설비학회논문지
    • /
    • 제23권9호
    • /
    • pp.17-23
    • /
    • 2009
  • 자외선 살균기술을 바탕으로 한 수처리 분야에 대한 관심이 최근 증가하고 있다. 수처리분야에서 살균처리방식의 효율은 유체 살균챔버나 살균강도 그리고 미생물의 불활성역학에 따라 수처리 성능이 결정된다. 광산화법에 이용되는 빛은 주로 자외선이 이용되며 매우 깨끗하고 높은 에너지를 가지고 있어 화학살균방법에 비해 잔류물이 없고 높은 안정성으로 최근 관심이 높아지고 있다. 그러나 자외선살균방식은 조사시간과 조사량에 직접적인 영향을 받아 이를 위한 최적의 설계가 이루어져야 한다. 본 연구에서는 유수살균장치의 챔버 내의 자외선 램프와 유수에 대한 3D-CFD discrete ordinates model 모델을 제시하고 이를 시뮬레이션을 통해 설계방식의 최적화 여부를 검증하고 향후 유수형 자외선살균방식의 시뮬레이션방법을 제안하고자 한다.

호소의 수질개선을 위하여 설치한 부댐의 장기간 성능평가 (Long-term Performance of Secondary dam Installed for Water Purification of Reservoir)

  • 김봉균;박준석;원희재;김윤용
    • 한국산학기술학회논문지
    • /
    • 제19권10호
    • /
    • pp.668-676
    • /
    • 2018
  • 우리나라의 저수지는 유효수심이 낮고 소규모의 인공호소가 대부분이어서 주변의 농경지로부터 유입되는 유기물질과 축산폐수 및 생활하수에 의한 수질오염에 취약한 실정이다. 이에 여러 가지 공법을 통하여 이를 개선하고자 노력하고 있으나 여전히 저수지의 오염정도가 심각한 실정이다. 따라서 본 연구에서는 저수지의 유입부에 설치되는 침강지를 조성하기 위한 사석 위주의 부댐을 대체하면서 수질정화 효과를 부여하기 위하여 수질정화용 부댐을 경기도내 저수지에 설치하여 36개월간 수질개선효과를 측정하였다. 연구결과에 따르면 COD 14.6%, SS 38.6%, T-N 9.5%, T-P 11.2%로 나타났으며 계절 등 시기별로 유입수의 농도 변화가 뚜렷하였고 유입수의 농도가 높을수록 수질정화효과가 높게 나타났으며 36개월의 장기간 운영에 따른 여재의 공극 막힘 현상은 발생하지 않았다. 따라서 침강지의 정화효율이 아닌 부댐의 정화효율임을 고려하여 볼 때 수질정화용 부댐을 농업용 저수지에 설치할 경우 장기간 동안 침강지로부터 호소내로 유입되는 오염물질을 효과적으로 차단하여 호내의 수질오염을 방지할 수 있을 것으로 판단된다.

현장실험을 통한 수생식물의 수질정화 효과에 관한 연구 (A Study on the Water Quality Purification Effect of Aquatic Plants in field work)

  • 이종성;김기남
    • 한국환경과학회지
    • /
    • 제14권10호
    • /
    • pp.937-944
    • /
    • 2005
  • Presently, aquatic plants are used for the water purification in inland water. This study was carried out to investigate the water purification effect of aquatic plants, Oenanthe javanica and Typha angustata, The experiment was conducted in outdoor flowing water was conducted for ten days, Water quality was measured in terms of water temperature, COD(chemical oxygen demand), SS(suspended solids), Total N, Total P. The results of field experimentation showed that hydraulic retention time was the earliest in July and August 2003, and there were not any particular changes of monthly water temperature in inflow water and outflow water. As we look at the changes taken place in inflow water and outflow water throughout the whole experiment period, the change of water quality in summer was salient, especially SS removal ratio showed distinguished change as $25\%$, when the pebble filter and aquatic were attached to it. The removal rate of COD, total N total P were $14,7\%,\;8\%\;and\;9\%$, respectively. In relating the length of water extension to the change in water quality, the water quality tended to get lower generally in proportion to hydraulic retention time.

태화강의 수질오염 특성에 관한 연구 - 화학적 산소요구량과 염소이온 농도 - (A Study on the Water Pollution Characteristics of the Taewha River - Chemical Oxygen Demand and Chloride ion Concentration -)

  • 류석환
    • 한국환경과학회지
    • /
    • 제2권4호
    • /
    • pp.291-297
    • /
    • 1993
  • The COD values and chloride ion concentrations of the Taewha river flowing through Ulsan area were determined along the main stream and the relationships between CODs and chloride ion concentrations were described. The results showed that the middle-upper stream and downstream of the Taewha river were polluted deeply with municipal sewage and self-purification occured in the middle-downstream of the river. When domestic sewage is a main source of pollutants, and is especially the only source of chloride in the stream water, the ratio of COD/[$\textrm{Cl}^{-}$] will be utilizable as a measure of self-purification of the stream.

  • PDF

유용미생물을 이용한 포러스콘크리트의 수질정화특성에 대한 현장평가 (Site Assessment for the Water Purification Effect of Porous Concrete by using Effective Micro-organisms)

  • 김봉균;박준석;서대석;김화중;김윤용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.109-119
    • /
    • 2015
  • 최근 수십년간의 산업발달 및 인구증가에 따라 산업폐수 및 각종 비점오염원의 유입으로 수질오염이 심각한 실정이다. 이에 대해 국내 및 국외에서 이에 대한 연구가 활발히 진행되고 있다. 본 연구에서는 유기물질의 분해효과가 있는 유용미생물과 포러스콘크리트를 이용하여 하천 현장에 설치하여 구조적 성능평가와 장기간 수질정화능력을 평가하였다. 구조적 성능평가 결과, 시험체의 공극률은 15%가 적절하다고 판단되며, 또한 수질정화성능 검토 결과 각항목에 대한 제거율은 SS 34.1%, BOD 14.6%, COD 34.9%, T-N 11.4%, T-P 12.6%를 나타냈다. 따라서 유용미생물을 이용한 포러스콘크리트의 현장적용시 수질을 정화시키는데 효과적이라고 판단된다.

자갈하상 하천에서 부착미생물군집의 거동 (Dynamics of Attached Microbial Community on the River with Gravel Riverbed)

  • 박재영;최이송;오종민
    • 한국수자원학회논문집
    • /
    • 제38권3호
    • /
    • pp.235-244
    • /
    • 2005
  • 본 연구는 국가하천인 오산천에서 수행되었으며, 하천의 자정기능을 증대시키기 위해 부착미생물군집을 중심으로 하천에서 거동을 정량적으로 조사하였다. 하천현장에서 장기간에 걸친 모니터링을 통해 다음과 같은 결과를 도출하였다. 부착미생물군집의 현존량은 소보다는 여울구간에서 더 높았으며, 여울구간에서도 흐름 유속이 상대적으로 빠른 급여울지역에서 더 많았다. 또한, 부착미생물군집이 하상기질에 부착하는 초기에는 빠른 유속이 부착미생물군집의 증식에 부정적으로 작용하지만, 부착미생물군집이 기질에 적응하여 증식하게 되는 중${\cdot}$후반기에는 유속이 오히려 증식을 돕는데 긍정적으로 작용하였다. 강우, 댐이나 저수지 방류와 같은 외부압력에 의해 교란이 발생하였을 때, 흐름의 세기와 외부압력의 형태에 따라 탈리되는 정도가 서로 다르고, 부착미생물군집 전량이 탈리되지 않기 때문에 회복속도는 비교적 빠른 것으로 관측되었다. 따라서 본 연구를 통해서 부착미생물군집은 하천의 자정작용에 부정적 혹은 긍정적으로 작용하는 것을 알 수 있었다. 따라서 하천의 자정작용을 향상시키기 위해서는 그 하천의 수질특성에 적합한 하상형태가 적용되어야 하며, 각 구간에 적합한 하도구조물을 설치하여 각 구간별 정화작용을 극대화 시킬 수 방법이 모색되어야 할 것으로 사료된다.

Purification of Water Contaminants Using Activated Carbon Fiber Filter with Phenolic Resin Coated on Glass Fibers as a Precursor

  • Baek, Il-Hyun
    • Carbon letters
    • /
    • 제1권2호
    • /
    • pp.82-86
    • /
    • 2000
  • The present research was undertaken to evaluate the possibility of water purification filter with activated carbon fibers (ACFs) using a very low cost precursor consisting of phenolic resin coated on glass fibers. The simplified procedure involving coating, curing and activation and a very low cost glass fiber as a raw material were adopted in order to reduce manufacturing cost. The breakthrough curves of the manufactured ACFs and the commercial activated carbon (AC, Calgon F-200) were investigated in the initial concentration range from 19 to 49 ppm for benzene, toluene and ethylbenzene. From breakthrough profiles, the manufactured ACFs had significantly faster adsorption kinetics than the AC. Especially the benzene breakthrough curves, the manufactured ACF (13 g of ACF with 32% of carbon on the glass) was over the limited level (5 ppb) after flowing of 32 l at initial concentration of 15 ppm, while the commercial AC was shown about 3 ppm in initial adsorption.

  • PDF