• 제목/요약/키워드: Flowable composite resins

검색결과 34건 처리시간 0.036초

A COMPARATIVE STUDY BETWEEN DEGREE OF CONVERSION AND FLEXURAL STRENGTH OF COMPOSITE RESINS

  • Lee Seong-Hee;Pae Ahran;Kim Sung-Hun
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.333-342
    • /
    • 2006
  • Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal information in the literature attempting to compare degree of conversion, flexural strength and their correlation between restorative composite resins and flowable composite resins. Purpose. The purposes of this study were to measure the degree of conversion and flexural strength of composite resins with different rheological behavior and to correlate the two properties. Materials and methods. Four restorative (Vit-1-escence, Z-250, Tetric ceram, Esthet-X) and four flowable (Aeliteflo, Admiraflow, Permaflo, Revolution) light-curing composite resins were investigated. The degree of conversion(DC) was analyzed with Fourier transfer infra-red spectroscopy(FTIR) spectrum by a potassium bromide(KBr) pellet transmission method. The spectrum of the unpolymerized specimen had been measured before the specimen was irradiated for 60s with a visible light curing unit. The Poiymerized specimen was scanned for its in spectrum. The flexural strength(FS) was measured with 3-point bending test according to ISO 4049 after storage in water at $37^{\circ}C$ for 24 hours. The data were statistically analyzed by an independent sample t-test and one-way ANOVA at the significance level of 0.05. The dependence of flexural strength on the degree of conversion was also analyzed by regression analysis. Results. Mean DC and FS values ranged from 43% to 61% and from 84.7MPa to 156.7MPa respectively. DC values of the flowable composite resins were significantly higher than those of restorative composite resins (P < 0.05). The FS values of restorative composite resins were greater than those of flowable composite resins. No statistically significant correlation was observed between the DC and the FS tested in any of the composites. The dependence of FS on DC in restorative or flowable composite resins was not significant. Conclusion. It can be concluded that radical polymerization of the organic matrix is not a major factor in determining flexural strength of the commercially available composite resins.

유동성 복합레진의 물리적 성질에 대한 연구 (A STUDY ON PHYSICAL PROPERTIES OF FLOWABLE COMPOSITE RESINS)

  • 김지영;정병초;양규호
    • 대한소아치과학회지
    • /
    • 제29권3호
    • /
    • pp.423-429
    • /
    • 2002
  • 최근 유동성 복합레진은 조작시 빠르고 간편하며 우수한 접근성으로 임상에서의 사용이 증가하고 있으나 각 제품간 그리고 혼합형 복합레진과의 물리적 성질이나 특성에 관한 비교 연구는 미흡한 실정이다. 이에 본 연구에서는 현재 임상적으로 자주 쓰이는 4종의 유동성 복합레진(Filtek Flow, Tetric Flow, Revolution, Palfique Esthelite LV high flow)의 압축 강도, 상대적 유동성, 방사선 불투과성을 측정하여 그 특성을 비교하여 다음과 같은 결론을 얻었다. 1. 압축강도에 있어서 4종의 유동성 복합레진 각 제품간의 유의한 차이는 없었으나 유동성 복합레진이 혼합형 복합레진(Z-100, 3M, USA)에 비하여 유의성 있게 낮은 압축강도를 나타내었다(p<0.001). 2. 각 제품간의 상대적 유동성은 Palfique Esthelite LV high flow, Revolution, Filtek Flow와 Tetric Flow 순으로 높았고(p<0.001), Filtek Flow와 Tetric Flow간에 유의한 차이는 없었으며, 모든 제품은 TeethmateF-1(Kuraray, Japan)에 비하여 유의성 있게 낮았다(p<0.001). 3. 유동성 복합레진 4종의 방사선 불투과성을 비교 분석한 결과 측정된 모든 유동성 복합레진은 상아질과 유사하거나 높은 방사선 불투과성을 나타내었고 각 제품간 유의한 차이가 있었다(p<0.001). 그 중 Tetric Flow와 Filtek Flow는 법랑질과 유사하거나 높은 방사선 불투과성을 나타내었다(p<0.001). 이상의 실험 결과는 4종의 유동성 복합레진은 혼합형 복합레진 보다 낮은 압축강도를 가지므로 임상에 적용 시 가해질 수 있는 응력을 고려하여야 하며, 각 제품간 유동정의 유의한 차이는 시술 시 재료의 선택에 고려사항이 될 수 있으리라 사료된다. 또한 4종의 유동성 복합레진의 방사선 불투과성은 모두 국제 인증 규격에 합당한 것으로 사료된다.

  • PDF

Microleakage of posterior packable composite resin at the gingival margins of class II cavities

  • Choi, Su-Jin;Kwon, Hyuk-Choon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.585.1-585
    • /
    • 2001
  • The use of flowable composite resins as liners in class II packable composite resins has been suggested by some manufacturers. However, the contributions of this technique are unproven. Objectives: The aim of this study was to compare the gingival microleakage in class II packable composite restorations with or without the use of flowable composite resins as liners.. Method: Slot cavities were prepared on both proximals of 80 extracted human molars and randomly assigned to 8 groups of 20 each.(중략)

  • PDF

유동성 및 응축성 복합레진의 점탄성에 관한 유변학적 연구 (RHEOLOGIC STUDY ON THE VISCOELASTIC PROPERTIES OF FLOWABLE AND CONDENSABLE RESIN COMPOSITES)

  • 이인복;조병훈;손호현;권혁춘;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.359-370
    • /
    • 2000
  • The purpose of this investigation was to observe the viscoelastic properties of five commercial flowable(Aeliteflo, Flow it, Revolution, Tetric flow, Compoglass flow), three conventional hybrid(Z-100, Z-250, P-60) and two condensable(Synergy compact, SureFil) resin composites. A dynamic oscillatory shear test was done to evaluate the storage shear modulus (G'), loss shear modulus(G"), loss tangent(tan ${\delta}$) and complex viscosity(${\eta}^*$) of the resin composites as a function of frequency - dynamic frequency sweep test from 0.01 to 100 rad/s at $25^{\circ}C$ - by using Advanced Rheometric Expansion System(ARES). To investigate the effect on the viscosity of resin composites of filler volume fraction, the filler weight % and volume % were measured by means of Archimedes' principle using a pyknometer. The results were as follows 1. The complex viscosity ${\eta}^*$ of flowable resins was lower than that of hybrid resins and significant differences were observed between brands. The complex viscosity ${\eta}^*$ of condensable resins was higher than that of hybrid resins. The order of complex viscosity ${\eta}^*$ at ${\omega}$=10 rad/s was as follows, Surefil, Synergy compact, P-60, Z-250, Z-100, Aeliteflo, Tetric flow, Compoglass flow, Flow it, Revolution. The relative complex viscosity of flowable resins compared to Z-100 was 0.04~0.56 but Surefil was 30.4 times higher than that of Z-100. 2. The storage shear modulus G' and the loss shear modulus G" of flowable resins were lower than those of hybrid resins but those of condensable resins were higher. The patterns of the change of loss tangent, tan ${\delta}$, of resin composites with increasing frequency were significantly different between brands. The phase angles, ${\delta}$, ranged from $30.2{\sim}78.1^{\circ}$ at ${\omega}$=10 rad/s. 3. All composite resins represent pseudoplastic nature with increasing shear rate. 4. The complex shear modulus $G^*$ and the phase angle ${\delta}$ was represented by the frequency domain phasor form, $G^*({\omega})=G^*e^{i{\delta}}=G^*{\angle}{\delta}$. The locus of frequency domain phasor plots in a complex plane was a valuable method that represent the viscoelastic properties of composite resins. 5. There was no direct linear correlationship but a weak positive relation was observed between filler volume % or weight % and the viscosity of the resin composites.

  • PDF

제 2급 와동에서 구치부 복합레진의 미세변연누출에 관한 연구 (MICROLEAKAGE OF POSTERIOR PACKABLE COMPOSITE RESIN hi THE GINGIVAL MARGINS OF CLASS II CAVITIES)

  • 최수진;김미자;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.249-256
    • /
    • 2002
  • The use of flowable composite resins as liners in class II packable composite restoration has been suggested by some manufacturers. However, the contributions of this technique are unproven. The purpose of this study was to compare the gingival microleakage in class II packable composite restorations with or without the use of flowable composite resins as liners. Slot cavities were prepared on both proximals of 80 extracted human molars and randomly assigned to 8 groups of 20 each. The gingival margins were located at 1mm above CEJ in 80 cavities (group1-4) and 1mm below CEJ in 80 cavities (group5-8). The prepared teeth were mounted in the customized tray with adjacent teeth to simulate clinical conditions and metallic matrix band (Sectional matrix) and wooden wedges were applied. After acid etching and application of Single Bond, each group was restored with the following materials using incremental placement technique: Group 1,5 (Filtek P60), group 2, 3, 4 and group 6, 7, 8 (AeliteFlo, TetricFlow, Revolution/ Filtek P60). All specimens were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 1 mimute dwell time, immersed 2% methylene blue dye for 24 hours and then rinsed with tab water. The specimens were embedded in clear resin and sectioned longitudinally through the center of restoration with a low speed diamond saw. Dye penetration at gingival margin was viewed at 20 magnification and analyzed on a scale of 0 to 4. Kruscal-Wallis One way analysis and Mann-Whitney Rank sum test were used to analyze the results. The results of this study were as follows. 1. The leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. On the enamel margin, packable composite resins with flowable liners showed lower leakage than those without flowable liners, but there were no significant differences among the four groups(P>0.05). 3. On the dentin margin, four groups demonstrated moderate to severe leakage, and there were no significant differences in leakage values(P>0.05).

Wear of contemporary dental composite resin restorations: a literature review

  • Dimitrios Dionysopoulos;Olga Gerasimidou
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.18.1-18.13
    • /
    • 2021
  • Composite resins are the most commonly used dental restorative materials after minimally invasive dental procedures, and they offer an aesthetically pleasing appearance. An ideal composite restorative material should have wear properties similar to those of tooth tissues. Wear refers to the damaging, gradual loss or deformation of a material at solid surfaces. Depending on the mechanism of action, wear can be categorized as abrasive, adhesive, fatigue, or corrosive. Currently used composite resins cover a wide range of materials with diverse properties, offering dental clinicians multiple choices for anterior and posterior teeth. In order to improve the mechanical properties and the resistance to wear of composite materials, many types of monomers, silane coupling agents, and reinforcing fillers have been developed. Since resistance to wear is an important factor in determining the clinical success of composite resins, the purpose of this literature review was to define what constitutes wear. The discussion focuses on factors that contribute to the extent of wear as well as to the prevention of wear. Finally, the behavior of various types of existing composite materials such as nanohybrid, flowable, and computer-assisted design/computer-assisted manufacturing materials, was investigated, along with the factors that may cause or contribute to their wear.

Microleakage of Class V cavity restored with flowable and microfill composite resins after load cycling.

  • Kang, Suk-Ho;Son, Ho-Hyun
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.569.2-569
    • /
    • 2001
  • Flowable and microfill composites have been recommended for Class V cavities. But the use of flowable composites is controversial because of its physical properties. Objectives: The aim of this study was to evaluate the microleakage of 6 composites (2 hybrids, 2 microfills, and 2 flowable composites) with/without load cycling. Methods: Notch-shaped Class V cavities were prepared on buccal surfaces of 180 extracted human upper premolars and then divided into non-load cycling group(G1) and load cycling group(G2).(omitted)

  • PDF

유동성 복합레진의 마모저항성에 관한 연구 (A STUDY ON WEAR RESISTANCE OF FLOWABLE COMPOSITE RESINS)

  • 윤연희;김정욱;이상훈;한세현
    • 대한소아치과학회지
    • /
    • 제29권2호
    • /
    • pp.217-225
    • /
    • 2002
  • 시술시간을 줄이는데 유리한 재료인 유동성 복합레진을 유구치부에 사용하려고 고려할 때 중요한 물성 중 하나는 마모저항성이다. 이 연구의 목적은 유동성 복합레진의 마모저항성을 일반복합레진의 마모저항성과 비교하는 것이다. 실험에 사용된 유동성 복합레진으로 1군에서는 Arabesk flow (VOCO, Germany) 2군에서는 Tetric flow (Vivadent, Liechtenstein) 3군에서는 Aeliteflow (Bisco, U.S.A.), 4군에서는 Filtek flow (3M Dental Co, U.S.A)을 사용하였으며 대조군으로 사용한 5군의 복합레진은 Z100 (3M Dental Co, U.S.A)이었다. 시편들(n=10)은 두께 2mm, 지름 5mm의 원통모양으로 제작하여 마모시험 전 $37^{\circ}C$의 증류수에서 7일 동안 담가 놓았다. 제1소구치와 레진시편을 MTS 시스템에서 2Hz로 50,000회 접촉, 마모시켰다. 마모시험시 lateral excursion은 0.4mm, 교합력은 2-100N의 조건이었다. 마모시험후 마모된 부피, 최대마모깊이, 재료자체의 표면경도를 측정하였고 마모 되지 않은 표면과 마모가 일어난 표면을 주사전자현미경으로 관찰하였으며 다음과 같은 결과를 얻었다. 1. 마모된 부피는 3군에서 가장 적었고 4군에서 가장 많았으며 3군<1군<2군<5군<4군의 순서로 증가하였다. 2. 3군, 1군, 2군은 5군이나 4군에 비해 통계적으로 유의하게 마모부피가 적었다(p<0.05). 그러나, 3군, 1군, 2군 사이에서와 5군, 4군 사이에서는 각각 통계적으로 유의한 차이가 없었다. 3. 최대마모깊이는 1군에서 가장 낮았고, 4군에서 가장 깊었으며 1군<3군<5군<2군<4군의 순서로 증가 하였다. 4. 5군의 표면경도는 다른 유동성 복합레진군에 비해 통계적으로 유의하게 높았으나(p<0.05), 마모부피나 최대마모깊이와는 통계적으로 유의한 상관관계를 보이지 않았다. 5. 마모되지 않은 표면과 마모가 일어난 표면을 주사전자현미경으로 관찰한 결과, 유동성 복합레진군과 5군 사이에 마모양상이 다르게 나타나는 것을 볼 수 있었다.

  • PDF

투명 fiber 포스트를 통한 광중합형 접착레진의 중합 반응 (CURING REACTION OF THE LIGHT CURED FLOWABLE COMPOSITE RESINS THROUGH THE ENDODONTIC TRANSLUCENT FIBER POST)

  • 안석;박상원;양홍서;방몽숙;박하옥
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.1-9
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the efficacy and substitute possibility of a newly developed flowable composite resins as a luting cement for translucent fiber post. Material & Method: Two kinds of 12 mm translucent fiber Post (D.T. Light-Post (Bisco, USA) and FRC Postec (Ivoclar vivadent, Liechtenstein) was inserted into the teflon mold (7 mm diameter, 9 mm long) and Filtek-Flow (3M ESPE. USA), a light activated flowable composite resin, was polymerized for 60 seconds through the post. Also, the post was cut from the tip to 9 mm, 6 mm, 3 mm, and Filtek-Flow was light cured according to each length. For comparison, 60 seconds light-cured and 24 hours self-cured two dual cured resin cement (Duo-cement (Bisco, USA) and 2 Panavia-F (Kuraray, Japan)) samples were prepared as control group. Also cavities (1 mm in width, 1 mm in depth and 12 mm in length) were prepared using acrylic plate and aluminum bar, and flowable composite resin was flied and light cured by the diffused light from the fiber post's side wall. The degree of polymerization was measured according to the distance from curing light using Vickers' hardness test. Result: Within the limitation of this study, the following conclusions were drawn: 1. Vickers' hardness of light cured dual cured resin cement and flowable composite resin decreased from Panavia-F, Filtek-Flow and Duo-cement accordingly (p<0.05). In the dual curing resin cement, light curing performed group showed higher surface hardness value than self cured only group (p<0.05). 2. Surface hardness ratio (light cured through fiber post /directly light cured) of D.T. Light-Post using Filtek-Flow showed about 70% in the 6 mm deep and about 50% in the 12 mm deep FRC Postec showed only 40% of surface hardness ratio. 3. Surface hardness ratio by diffused light from the post's side wall showed about 50% at 6 mm and 9 mm deep, and about 40% at 12 mm deep in D.T. Light-Post. However, FRC Postec showed about 40% at 6 mm deep, and almost no polymerization in 9 mm and 12 mm deep.

Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교 (MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING)

  • 강석호;김오영;오명환;조병훈;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).