• Title/Summary/Keyword: Flow-rate uniformity

Search Result 186, Processing Time 0.033 seconds

A study on the optical properties of $LiNbO_3$ single crystal grown by Floating zone method (Floating zone 법에 의한 $LiNbO_3$ 단결정의 광학적 특성에 관한 연구)

  • Ko, J.M.;Cho, H.;Kim, S.H.;Choi, J.K.;Auh, K.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.5 no.4
    • /
    • pp.318-331
    • /
    • 1995
  • The c - axis oriented single crystal of $LiNbO_3$ and $LiNbO_3$ : 5mol%MgO was success-fully grown by Floating zone method using halogen lamp as a heat source. The effects of the sintering condition of the feed rod and the atmosphere gas during the crystal growth on the be havior of the feed rod/melt interface were studied for growing crystal with the high quality, and then, the optimum growth conditions were determined by studying the experimental param eters, such as gas flow rate, pulling rate, rotation speeds of the feed rod and the seed. The grown crystals were analyzed using the chemical etching to observe the tch pattern and the ICP (Inductively Coupled Plasma) to determine the composition uniformity and the impurity content of Fe. The effects of additive (5 mol % MgO) on the transmittance and refractive index was, also, analyzed. In order to compare the nonlinear optical oharacteristics of $LiNbO_3$ with those of the other optical materials, the nonlinear optical refractive index ($n_2$) was calcu l lated using the measured refractive index.

  • PDF

Fabrication of Large Area Transmission Electro-Absorption Modulator with High Uniformity Backside Etching

  • Lee, Soo Kyung;Na, Byung Hoon;Choi, Hee Ju;Ju, Gun Wu;Jeon, Jin Myeong;Cho, Yong Chul;Park, Yong Hwa;Park, Chang Young;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.220-220
    • /
    • 2013
  • Surface-normal transmission electro-absorption modulator (EAM) are attractive for high-definition (HD) three-dimensional (3D) imaging application due to its features such as small system volume and simple epitaxial structure [1,2]. However, EAM in order to be used for HD 3D imaging system requires uniform modulation performance over large area. To achieve highly uniform modulation performance of EAM at the operating wavelength of 850 nm, it is extremely important to remove the GaAs substrate over large area since GaAs material has high absorption coefficient below 870 nm which corresponds to band-edge energy of GaAs (1.424 eV). In this study, we propose and experimentally demonstrate a transmission EAM in which highly selective backside etching methods which include lapping, dry etching and wet etching is carried out to remove the GaAs substrate for achieving highly uniform modulation performance. First, lapping process on GaAs substrate was carried out for different lapping speeds (5 rpm, 7 rpm, 10 rpm) and the thickness was measured over different areas of surface. For a lapping speed of 5 rpm, a highly uniform surface over a large area ($2{\times}1\;mm^2$) was obtained. Second, optimization of inductive coupled plasma-reactive ion etching (ICP-RIE) was carried out to achieve anisotropy and high etch rate. The dry etching carried out using a gas mixture of SiCl4 and Ar, each having a flow rate of 10 sccm and 40 sccm, respectively with an RF power of 50 W, ICP power of 400 W and chamber pressure of 2 mTorr was the optimum etching condition. Last, the rest of GaAs substrate was successfully removed by highly selective backside wet etching with pH adjusted solution of citric acid and hydrogen peroxide. Citric acid/hydrogen peroxide etching solution having a volume ratio of 5:1 was the best etching condition which provides not only high selectivity of 235:1 between GaAs and AlAs but also good etching profile [3]. The fabricated transmission EAM array have an amplitude modulation of more than 50% at the bias voltage of -9 V and maintains high uniformity of >90% over large area ($2{\times}1\;mm^2$). These results show that the fabricated transmission EAM with substrate removed is an excellent candidate to be used as an optical shutter for HD 3D imaging application.

  • PDF

Routing of Groundwater Component in Open Channel (Saint-Venant 공식(公式)에 의한 개수로(開水路)의 지하수성분(地下水性分) 추적(追跡))

  • Kim, Jae Han
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.4
    • /
    • pp.23-32
    • /
    • 1988
  • The rates of infiltration contributed to the flow fo water in an unconfined aquifer under the partially penetrated stream at an ungaged station and the corresponding base flow in channel are coupled by using the hydraulic and/or hydrologic characteristics obtained from the geomorphologic and soil maps. For the determination of groundwater flow, the linearized model which is originally Boussinesq's nonlinear equation is applied in this study. Also, a stream flow routing model for base flow in channel is based on a simplification of the Saint-venant. The distributed runoff model with piecewise spatial uniformity is presented for obtaining its solution based on a finite difference technique of the kinematic wave equations. The method developed in this study was tested to the Bocheong watershed(area : $475.5km^2$) of the natural stream basin which is one of tributaries in Geum River basin in Korea. As a result, it is suggested that the rationality of hydro-graph separation according to a wide variability in hydrogeologic properties be worked out as developing the physically based subsurface model. The results of the present model are shown to be possible to simulate a base flow due to an arbitrary rate of infiltration for ungaged basins.

  • PDF

Effect of fringe divergence in fluid acceleration measurement using LDA (레이저 도플러 원리를 이용한 유체 가속도 측정)

  • Chun, Se-Jong;Nobach, Holger;Tropea, Cam;Sung, Hyung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1546-1551
    • /
    • 2004
  • The laser Doppler technique is well-established as a velocity measurement technique of high precision for flow velocity. Recently, the laser Doppler technique has also been used to measure acceleration of fluid particles. Acceleration is interesting from a fluid mechanics point of view, since the Navier Stokes equations, specifically the left-hand-side, are formulated in terms of fluid acceleration. Further, there are several avenues to estimating the dissipation rate using the acceleration. However such measurements place additional demands on the design of the optical system; in particular fringe non-uniformity must be held below about 0.0001 to avoid systematic errors. Relations expressing fringe divergence as a function of the optical parameters of the system have been given in the literature; however, direct use of these formulae to minimize fringe divergence lead either to very large measurement volumes or to extremely high intersection angles. This dilemma can be resolved by using an off-axis receiving arrangement, in which the measurement volume is truncated by a pinhole in front of the detection plane. In the present study an optical design study is performed for optimizing laser Doppler systems for fluid acceleration measurements. This is followed by laboratory validation using a round free jet and a stagnation flow, two flows in which either fluid acceleration has been previously measured or in which the acceleration is known analytically. A 90 degree off-axis receiving angle is used with a pinhole or a slit.

  • PDF

CFD Analysis on the Flow Uniformity of a $CO_2$ Enrichment System (CFD를 이용한 온실 $CO_2$ 시비 시스템의 유량 균일성 해석)

  • Yim, Kyungjin;Kim, Hongjip;Lee, Sangmin;Park, Kyoung-Sub
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.123-130
    • /
    • 2013
  • $CO_2$ enrichment systems have been recently used to shorten the growth period of plants and the improvement of harvest and its quality. To accomplish these goals, manifold should be designed to supply the same amount of $CO_2$. In this study, CFD approach has been used to understand the effects of geometric parameters, such as tube and hole diameters. An optimized geometry has been derived through pipe and tube part, respectively. As a result, the deviation of flow rate less than 0.1 g/s was expected at all holes of the $CO_2$ enrichment system.

Performance Evaluation of a Double Layer Biofilter System to Control Urban Road Runoff (I) - System Design - (이중층 토양 여과시설을 이용한 도로 강우 유출수 처리성능 평가 (I) - 시설 설계인자 결정을 중심으로 -)

  • Cho, Kang Woo;Kim, Tae Gyun;Lee, Byung Ha;Lee, Seul Bi;Song, Kyung Guen;Ahn, Kyu Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.599-608
    • /
    • 2009
  • This manuscript covers the results of field investigation and lab-scale experiments to design a double-layered biofilter system to control urban storm runoff. The biofilter system consisted of a coarse soil layer (CSL) for filtration and fine soil layer (FSL) for adsorption and biological degradation. The variations of flow rate and water quality of runoff from a local expressway were monitored for seven storm events. Laboratory column experiments were performed using seven kinds of soil and mulch to maximize pollutants removal. The site mean concentration (SMC) of storm runoff from the drainage area (runoff coefficient: 0.92) was measured to be 203 mg/L for SS, 307 mg/L for $TCOD_{Cr}$, 12.3 mg/L for TN, 7.3 mg/L for ${NH_4}^+-N$, and 0.79 mg/L for TP, respectively. This study employed a new design concept, to cover the maximum rainfall intensity with one month recurrence interval. Effective storms for last ten years (1998-2007) in seoul suggested the design rainfull intensity to be 8.8 mm/hr Single layer soil column showed the maximum removal rate of pollutants load when the uniformity coefficient of CSL was 1.58 and the silt/clay contents of FSL was virtually 7%. The removal efficiency during operation of double layer soil column was 98% for SS and turbidity, 75% for TCODCr, 56% for ${NH_4}^+-N$, 87% for TP, and 73-91% for heavy metals. The hydraulic conductivity of the soil column, 0.023 cm/sec, suggested that the surface area of the biofilter system should be about 1% of the drainage area to treat the rainfall intensity of one month recurrence interval.

Microscopy Study for the Batch Fabrication of Silicon Diaphragms (실리콘 Diaphragm의 일괄 제조공정을 위한 Microscopy Study)

  • 하병주;주병권;차균현;오명환;김철주
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.1
    • /
    • pp.33-40
    • /
    • 1992
  • Several etching phenomena were observed and analyzed in diaphragm process performed on 4-inch (100) Si wafers for sensor application. In case of deep etching to above 300$\mu$m depth, the etch-defects appeared at etched surface could be classified into three categories such as hillocks, reaction products, and white residues. It was known that the hillock had a pyramidal shape or trapizoidal hexahedron structure depending on the density and size of the reaction products. The IR spectra showed that the white residue, which was due to the local over-saturation of Si dissolved in solution, was mostly Si-N-O compounds mixed with a small amount of H and C etc. Also, the difference in both the existence of etch-defects and etch rate distribution over a whole wafer was investigated when the etched surfaces were downward, upward horizontally and erective in etching solutions. The obtained data were analyzed through flow pattern in the etching bath. As the results, the downward and erective postures were favorable in the etch rate uniformity and the etch-defect removal, respectively.

  • PDF

Statistical Techniques based Computer-aided Diagnosis (CAD) using Texture Feature Analysis: Applied of Cerebral Infarction in Computed Tomography (CT) Images

  • Lee, Jaeseung;Im, Inchul;Yu, Yunsik;Park, Hyonghu;Kwak, Byungjoon
    • Biomedical Science Letters
    • /
    • v.18 no.4
    • /
    • pp.399-405
    • /
    • 2012
  • The brain is the body's most organized and controlled organ, and it governs various psychological and mental functions. A brain abnormality could greatly affect one's physical and mental abilities, and consequently one's social life. Brain disorders can be broadly categorized into three main afflictions: stroke, brain tumor, and dementia. Among these, stroke is a common disease that occurs owing to a disorder in blood flow, and it is accompanied by a sudden loss of consciousness and motor paralysis. The main types of strokes are infarction and hemorrhage. The exact diagnosis and early treatment of an infarction are very important for the patient's prognosis and for the determination of the treatment direction. In this study, texture features were analyzed in order to develop a prototype auto-diagnostic system for infarction using computer auto-diagnostic software. The analysis results indicate that of the six parameters measured, the average brightness, average contrast, flatness, and uniformity show a high cognition rate whereas the degree of skewness and entropy show a low cognition rate. On the basis of these results, it was suggested that a digital CT image obtained using the computer auto-diagnostic software can be used to provide valuable information for general CT image auto-detection and diagnosis for pre-reading. This system is highly advantageous because it can achieve early diagnosis of the disease and it can be used as supplementary data in image reading. Further, it is expected to enable accurate medical image detection and reduced diagnostic time in final-reading.

Experimental Study of Pressure Drop in Compressible Fluid through Porous Media (다공성재를 통과하는 압축성 유체의 압력강하에 관한 실험적 연구)

  • Seo, Min Kyo;Kim, Do Hun;Seo, Chan Woo;Lee, Seoung Youn;Jang, Seok Pil;Koo, Jaye
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.759-765
    • /
    • 2013
  • This study proposes the characteristics of the pressure drop in a compressible fluid through porous media for application to a porous injector in a liquid rocket engine in order to improve the uniformity of the drop size distribution and the mixing performance of shear coaxial injectors. The fluid through the porous media is a Non-Darcy flow that shows a Nonlinear relation between the pressure drop and the velocity at high speed and high mass flow rate. The pressure drop of the Non-Darcy flow can be derived using the Forchheimer equation that includes the losses of viscous and inertia resistance. The permeability and Ergun coefficient represented as a function of the pressure drop and pore size can be applied to the porous injector, where the fluid through the porous media is compressible. A generalized correlation between the pressure drop in relation to the pore size was derived.

Effect of Inlet Shape on Thermal Flow Characteristics for Waste Gas in a Thermal Decomposition Reactor of Scrubber System (반도체 폐가스 처리용 열분해반응기의 입구형상이 열유동 특성에 미치는 영향에 관한 수치해석 연구)

  • Yoon, Jonghyuk;Kim, Youngbae;Song, Hyungwoon
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.510-518
    • /
    • 2018
  • Recently, lots of interests have been concentrated on the scrubber system that abates waste gases produced from semiconductor manufacturing processes. An effective design of the thermal decomposition reactor inside a scrubber system is significantly important since it is directly related to the removal performance of pollutants and overall stabilities. In the present study, a computational fluid dynamics (CFD) analysis was conducted to figure out the thermal and flow characteristics inside the reactor of wet scrubber. In order to verify the numerical method, the temperature at several monitoring points was compared to that of experimental results. Average error rates of 1.27~2.27% between both the results were achieved, and numerical results of the temperature distribution were in good agreement with the experimental data. By using the validated numerical method, the effect of the reactor geometry on the heat transfer rate was also taken into consideration. From the result, it was observed that the flow and temperature uniformity were significantly improved. Overall, our current study could provide useful information to identify the fluid behavior and thermal performance for various scrubber systems.