• Title/Summary/Keyword: Flow-3D

Search Result 3,748, Processing Time 0.032 seconds

The subtle effect of integral scale on the drag of a circular cylinder in turbulent cross flow

  • Younis, Nibras;Ting, David S.K.
    • Wind and Structures
    • /
    • v.15 no.6
    • /
    • pp.463-480
    • /
    • 2012
  • The effects of Reynolds number (Re), freestream turbulence intensity (Tu) and integral length scale (${\Lambda}$) on the drag coefficient ($C_d$) of a circular cylinder in cross flow were experimentally studied for $6.45{\times}10^3$ < Re < $1.82{\times}10^4$. With the help of orificed plates, Tu was fixed at approximately 0.5%, 5%, 7% and 9% and the normalized integral length scale (L/D) was varied from 0.35 to 1.05. Our turbulent results confirmed the general trend of decreasing $C_d$ with increasing Tu. The effectiveness of Tu in reducing $C_d$ is found to lessen with increasing ${\Lambda}$/D. Most interestingly, freestream turbulence of low Tu (${\approx}5%$) and large ${\Lambda}$/D (${\approx}1.05$) can increase the $C_d$ above the corresponding smooth flow value.

Numerical investigation of flow characteristics through simple support grids in a 1 × 3 rod bundle

  • Karaman, Umut;Kocar, Cemil;Rau, Adam;Kim, Seungjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1905-1915
    • /
    • 2019
  • This paper investigated the influence of simple support girds on flow, irrespective of having mixing vanes, in a 1 × 3 array rod bundle by using CFD methodology and the most accurate turbulence model which could reflect the actual physics of the flow was determined. In this context, a CFD model was created simulating the experimental studies on a single-phase flow [1] and the results were compared with the experimental data. In the first part of the study, influence of mesh was examined. Tetra, hybrid and poly type meshes were analyzed and convergence study was carried out on each in order to determine the most appropriate type and density. k - ε Standard and RSM LPS turbulence models were used in this section. In the second part of the study, the most appropriate turbulence model that could reflect the physics of the actual flow was investigated. RANS based turbulence models were examined using the mesh that was determined in the first part. Velocity and turbulence intensity results obtained on the upstream and downstream of the spacer grid at -3dh, +3dh and +40dh locations were compared with the experimental data. In the last section of the study, the behavior of flow through the spacer grid was examined and its prominent aspects were highlighted on the most appropriate turbulence model determined in the second part. Results of the study revealed the importance of mesh type. Hybrid mesh having the largest number of structured elements performed remarkably better than the other two on results. While comparisons of numerical and experimental results showed an overall agreement within all turbulence models, RSM LPS presented better results than the others. Lastly, physical appearance of the flow through spacer grids revealed that springs has more influence on flow than dimples and induces transient flow behaviors. As a result, flow through a simple support grid was examined and the most appropriate turbulence model reflecting the actual physics of the flow was determined.

Flow Analysis of Parshall Flume Using FLOW-3D (FLOW-3D에 의한 파샬플륨 흐름 해석)

  • Oh, Byoung-Dong;Kim, Kyoung-Ho;Lee, Whan-Gi;An, Sang-Do
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.5
    • /
    • pp.375-386
    • /
    • 2004
  • A water shortage is one of the most important factors for development and management of water resources. For reliable water shortage measurement in a stream, Korea Water Resources Corporation(KOWACO) founded five foot Parshall flume at Yong-dam experimental watershed in 2000. The Parshall flume has a specially designed shape to facilitate flow measurements by eliminating sediment deposition problem that could lead to an incorrect measurement. In this study, computational fluid dynamics(CFD) model was used to analyze flow behavior of Parshall Flume under free discharge of five headwater level cases. The flow rates computed by CFD model are compared with those by ISO's formula, USBR's formula and stage-discharge rating curves. Flow rates computed by ISO's and USBR's formula are mostly same, but flow rate by CFD model is larger than empirical value by 9% and flow rate by stage-discharge rating curves is less than empirical value by 16%.

ANALYSIS ON COMPRESSIBLE FLOW WITHIN A SWIRL INJECTOR (스월 인젝터 내 압축성 유동 해석)

  • Suh Y.K.;Kang S.M.;Heo H.S.
    • Journal of computational fluids engineering
    • /
    • v.11 no.2 s.33
    • /
    • pp.40-48
    • /
    • 2006
  • In the present, The theoretical and numerical results of gas flow characteristics inside a swirl injector are presented. For this purpose a one-dimensional (theoretical) model and 2D/3D CFD models are proposed for use in the design of the injector. It was found that contradictory to the classical theory about the compressible flow, the swirl has a significant effect on the mass flow rate and the choking conditions. It was found that the one-dimensional model provides reasonably accurate results compared with the 2D/3D numerical results, and thus can be used at the initial stage of the swirl-injector design process.

Study on Compressible Swirl Flow within an Injector (분사기 내 압축성 스월 유동에 대한 연구)

  • Suh Y. K.;Kang S. M.;Heo H. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.207-212
    • /
    • 2005
  • In this paper, we present the theoretical and numerical results of flow characteristics of a gas in a swirl injector. Proposed in this study are one-dimensional (theoretical) model and 2D/3D CFD models for use in the design of the injector. It was found that contrary to the classical theory about the compressible flow, the swirl gives a significant effect on the mass flow rate and the choking conditions. The one-dimensional model was found to Provide reasonably accurate results compared with the 2D/3D numerical results, so that it can be employed in th initial stage of the swirl-injector design process.

  • PDF

Characteristics of the Internal Flow in the Scaled-Up Fuel Nozzle (연료 노즐을 확대한 모형노즐에서의 내부유동 특성)

  • 박장혁;홍성태;구자예
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.199-210
    • /
    • 1996
  • The measurements of velocities of internal flow in a scaled-up nozzle were made by laser Doppler velocimetry in order to clarify the effect of internal flow on the characteristics of fuel spray. The investigated length to diameter ratio(L/d) of the orifice were 1, 3, 4, 5 and 8, and inlet radius to diameter ratio(r0/d) were 0 and 0.5. Mean and fluctuating velocities and discharge coefficients were obtained at various Reynolds number ranging between 15,000 and 28,000, and L/d ranging between 1 and 8 in sharp and round inlet nozzle. The turbulent intensity and turbulent kinetic energy at exit in a sharp inlet nozzle were higher than that in a round inlet nozzle. For sharp inlet nozzle, fluctuating velocities near exit were decreased with increasing L/d.

  • PDF

Robust Viewpoint Estimation Algorithm for Moving Parallax Barrier Mobile 3D Display (이동형 패럴랙스 배리어 모바일 3D 디스플레이를 위한 강인한 시청자 시역 위치 추정 알고리즘)

  • Kim, Gi-Seok;Cho, Jae-Soo;Um, Gi-Mun
    • Journal of Broadcast Engineering
    • /
    • v.17 no.5
    • /
    • pp.817-826
    • /
    • 2012
  • This paper presents a robust viewpoint estimation algorithm for Moving Parallax Barrier mobile 3D display in sudden illumination changes. We analyze the previous viewpoint estimation algorithm that consists of the Viola-Jones face detector and the feature tracking by the Optical-Flow. The sudden changes in illumination decreases the performance of the Optical-flow feature tracker. In order to solve the problem, we define a novel performance measure for the Optical-Flow tracker. The overall performance can be increased by the selective adoption of the Viola-Jones detector and the Optical-flow tracker depending on the performance measure. Various experimental results show the effectiveness of the proposed method.

Power Savings of a Refrigerator with 3D-PTV Measurements (3D-PTV에 의한 냉장고 소비전력 저감)

  • Hwang Tae-Gyu;Doh Deog-Hee;Park Seong-Ryong;Bang Yoon-Seok;Yang Min-Cheol;Jang Gyu-Seob;Kim Suk-Roh;Lee Yeon-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1145-1153
    • /
    • 2005
  • 3D-PTV measurement has been carried out for the inner flows of a refrigerator. To visualize the air flows three-dimensionally, a helium bubble generator has been used for the 3D-PTV measurements. Three-dimensional flow field of the refrigerator's compartments have been reconstructed by the results obtained by the 3D-PTV Measurements on the electric power-consumption was also carried out in order to evaluate the improvements of the flow characteristics. It was verified that $3\%$ of power consumption was saved by improving the flow passages and characteristics.

Comparison of Correlation Coefficients and Intraclass Correlation Coefficients Between Two-way FSI Flow Velocity of Simulated Abdominal Aorta and Human 4D Flow MRI Flow Velocity (시뮬레이션 복부 대동맥의 양방향 FSI 유속과 인체 4D flow MRI 유속의 상관계수, 급내상관계수 비교)

  • Ahn, Hae Nam;Kim, Jung Hun;Park, Ji eun;Choi, Hyeun Woo;Lee, Jong Min
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.143-149
    • /
    • 2021
  • In order to predict and prevent the disease of the abdominal aorta, which is the largest artery in the human body and the most common aneurysm, the normal arterial blood flow operation should be considered. To this end, we are trying to solve problems that may arise in the future by executing FSI based on the data obtained from 4D flow MRI. However, to match the similarity between the 4D flow MRI flow and the FSI flow, correlation was used in previous papers, but the correlation did not show the degree of agreement. Therefore, in this paper, we analyzed the correlation between the 4D flow MRI flow velocity of the human abdominal aorta and the two-way FSI flow velocity in which the three physical properties used for the aortic FSI were added to the CT abdominal aorta 3D model and the interclass correlation coefficient. As a result, the physical property M2 showed the highest similarity in correlation and intraclass correlation coefficient, and this property is intended to be helpful in the future study of the abdominal aortic two-way FSI flow rate.

Three-dimensional dynamics of vortex-induced vibration of a pipe with internal flow in the subcritical and supercritical regimes

  • Duan, Jinlong;Chen, Ke;You, Yunxiang;Wang, Renfeng;Li, Jinlong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.6
    • /
    • pp.692-710
    • /
    • 2018
  • The Three-dimensional (3-D) dynamical behaviors of a fluid-conveying pipe subjected to vortex-induced vibration are investigated with different internal flow velocity ${\nu}$. The values of the internal flow velocity are considered in both subcritical and supercritical regimes. During the study, the 3-D nonlinear equations are discretized by the Galerkin method and solved by a fourth-order Runge-Kutta method. The results indicate that for a constant internal flow velocity ${\nu}$ in the subcritical regime, the peak Cross-flow (CF) amplitude increases firstly and then decrease accompanied by amplitude jumps with the increase of the external reduced velocity. While two response bands are observed in the In-line (IL) direction. For the dynamics in the lock-in condition, 3-D periodic, quasi-periodic and chaotic vibrations are observed. A variety of CF and IL responses can be detected for different modes with the increase of ${\nu}$. For the cases studied in the supercritical regime, the dynamics shows a great diversity with that in the subcritical regime. Various dynamical responses, which include 3-D periodic, quasi-periodic as well as chaotic motions, are found while both CF and IL responses are coupled while ${\nu}$ is beyond the critical value. Besides, the responses corresponding to different couples of ${\mu}_1$ and ${\mu}_2$ are obviously distinct from each other.