• 제목/요약/키워드: Flow pulsation

검색결과 187건 처리시간 0.03초

Mitigation of Flooding under Externally Imposed Oscillatory Gas Flow

  • Lee, Jae-Young;Chang, Jen-Shih
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.475-479
    • /
    • 1995
  • During the hypothetical loss of coolant accident in the nuclear power plant the emergency core cooling water could not penetrate to the reactor core when the steam flow rate from the reactor core exceeds CCFL (Countercurrent flow limitation). The CCFL generated by earlier investigators are developed under the steady gas flow. However the flow instability in the reactor loop could generate oscillatory steam flow, hence their applicability under oscillating flow should be investigated. In this work, an experimental investigation of countercurrent flow in the vertical flow channel has been conducted under oscillatory gas flow. Pulsation of gas under oscillatory flow disturbs the flow pattern significantly and prevents flooding (CCFL) when its minimum value is less than the threshold gas flow rate value.

  • PDF

합곡.중저.외관.곡지 뜸치료가 뇌졸중 편마비 환자의 환측 요골동맥 혈류 및 심박변이도에 미치는 영향 (The Effects of LI4, TE3, TE5 and LI11 Moxibustion on Radial Artery Blood Flow and Heart Rate Variability in Stoke Patients with Hemiplegia)

  • 윤승규;권승원;서유리;박준영;임진욱;박주영;조승연;정환용;박성욱;정우상;문상관;박정미;고창남;조기호;김영석;배형섭;이상훈;배영민
    • 대한한의학회지
    • /
    • 제32권5호
    • /
    • pp.50-65
    • /
    • 2011
  • Objectives: Moxibustion has been used for various post-stroke symptoms and has also been known to have effect on peripheral blood flow. This study investigated the effect of moxibustion on radial artery blood flow by Doppler ultrasound and on heart rate variability in post-stroke hemiplegia patients. Methods: Moxibustion was applied on the points of LI4, TE3, TE5 and LI11 on the affected side, and blood flow of the radial artery was measured using the Minimax-Doppler-K device. Blood flow velocity and pulsation index were analyzed before, during, and after moxibustion. Simultaneously LF, HF, and LF/HF as variables for HRV were measured by FM-150. Results: The mean value of blood flow velocity in all patients (n=23) showed significant increase between before and after moxibustion, but there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. In Yin (n=9) and Yang (n=14) groups, both showed significant increase of blood flow velocity between before and after moxibustion, but there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. In Deficiency (n=14) and Fullness (n=9) groups, only the Deficiency group showed significant increase of blood flow velocity between before and after moxibustion, while the Fullness group showed no significant difference in blood flow velocity between before and after moxibustion, and also there was no significant difference in pulsation index and LF, HF, LF/HF ratio between before and after moxibustion. Conclusions: This study suggests that moxibustion on LI4, TE3, TE5 and LI11 on the affected side of stroke patients increase the peripheral blood flow in the affected arm, which was most remarkable in those with Yin and Deficiency pattern.

The Effect of Pulsatile Flow on Ultrafiltration In-Vitro Study and Comparison with Roller Pump

  • Lee K.;Jeong J. H.;Mun C. H.;Lee J. C.;Min B. G.
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.337-341
    • /
    • 2005
  • Blood pulsation has been reported to have an advantageous effect on extracorporeal blood circulation. However, the study of pulsatile blood flow in renal replacement therapy is very limited. The in-vitro experimental results of pulsatile blood flow on ultrafiltration, when compared with the conventional roller pump, are described in this paper. Methods: Blood flow rate (QB) and transmembrane pressure (TMP) were considered as regulating factors that have an influence on ultrafiltration. Experiments were performed under the condition of equal TMP and OB in both pulsatile and roller pump groups, Several kinds of hollow fiber dialyzers were tested using distilled water containing chemicals as a blood substitute. Mean TMP (mTMP) varied from 10 to 90mmHg while the QB was 200ml/min. Results: Ultrafiltration rate (QUF) was found to be linearly proportional to TMP, whereas QB had little influence on QUF. In addition, QUF was higher in the pulsatile group than the roller pump group at the identical TMP. Conclusion: In the controlled test, QUF increased solely as a consequence of blood pulsation, which implies that the pulse frequency represents an additional and important clinical variable during renal replacement therapy.

유체유발하중을 받는 상부안내구조물의 랜덤진동 및 조화응답해석 (Random Vibration and Harmonic Response Analyses of Upper Guide Structure Assembly to Flow Induced Loads)

  • 지용관;이영신
    • 한국전산구조공학회논문집
    • /
    • 제15권1호
    • /
    • pp.59-68
    • /
    • 2002
  • 원자로 내부구조물의 상부안내구조물집합체는 노심지지배럴과 내부배럴집합체와 함께 원통형의 실린더 구조이며, 유체의 난류하중과 펌프의 맥동하중으로 인한 유체유발하중을 수평방향으로 받는다. 본 논문에서는 이 유체유발하중에 대한 랜덤진동해석과 조화응답해석을 수행한 내용을 기술하였다. 이 해석을 위해 집중질량 보 요소 모델을 사용하였고, 랜덤하중과 펌프맥동하중으로 발생되는 동적응답특성을 평가하였다. 특히 원통형태의 상부안내구조물, 노심지지배럴, 내부배럴집합체 사이에서 형성되는 환형공간의 동수력 연성 효과를 고려하여 모델링 하였고, 상부안내구조물 안쪽에 설치되는 내부배럴집합체의 추가 영향을 검토하였다. 내부배럴집합체의 추가로 인한 하중조건별 최대동적응답은 구조물의 고유진동수에 영향을 받으며, 따라서 구조물의 최대동적응답은 여러 하중 조건별 동적해석 평가를 통해 보수적으로 구하여져야 한다.

ANALYSES OF ANNULAR LINEAR INDUCTION PUMP CHARACTERISTICS USING A TIME-HARMONIC FINITE DIFFERENCE ANALYSIS

  • Seong, Seung-Hwan;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • 제40권3호
    • /
    • pp.213-224
    • /
    • 2008
  • The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction electro-magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a magneto-hydro-dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC "Sintez," D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the double supply frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump.

온수 가열 바닥 난방 시스템용 고성능 버블젯 루프 히트파이프 개발 (Development of High Performance Bubble Jet Loop Heat Pipe for Hot Water Floor Heating System)

  • 김종수;권용하;김정웅
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.23-28
    • /
    • 2014
  • In order to increase the performance of conventional hot water floor heating system, the bubble jet loop heat pipe for the system was developed. This experiment was conducted under next conditions : Working fluid was R-134a, charging ratio was 50%. A temperature of hot water, room temperature and flow rate were $60^{\circ}C$, $15^{\circ}C$ and 0.5~1.5 kg/min, respectively. The experimental results, show that bubble jet loop heat pipe had a high effective thermal conductivity of $4714kW/m^{\circ}C$ and a sufficient heat flux of $73W/m^2$ to heat the floor to $35^{\circ}C$ in case of the 1.5 kg/min of flow rate. So the bubble jet loop heat pipe has a possibility for appling of the floor heating system. Additionally, the visualization of bubble jet loop heat pipe was performed to understand the operating principle. Bubbles made by the narrow gap between inner tube and outer tube of evaporating part generate pulsation at liquid surface of working fluid. The pulsation had slug flow and wavy flow. So working fluid circulates in the bubble jet loop heat pipe as two phase flow pattern. And large amount of heat is transferred by the latent heat from evaporating part to condensing part.

단단 주 급수 펌프 임펠러에서 시운전 중 발생한 피로 절손에 관한 규명 연구 (Identification on Fatigue Failure of Impeller at Single Stage Feedwater Pumps During Commissioning Operation)

  • 김연환;김계연;배춘희;이영신
    • 한국소음진동공학회논문집
    • /
    • 제18권9호
    • /
    • pp.937-942
    • /
    • 2008
  • 이 논문은 건설이 완료된 700MW급 발전소의 시운전 기간 중 주 급수펌프 임펠러에서 반복적으로 발생된 웨어링 이탈 및 고착, 슈라우드 손상 그리고 축 절단 등의 절손이 부분부하 조건에서 증폭되는 압력맥동과 연관이 있는 것으로 규명되었다.

Transmission Path Analysis of Noise and Vibration in a Rotary Compressor by Statistical Energy Analysis

  • Hwang, Seon-Woong;Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Kyu-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제18권11호
    • /
    • pp.1909-1915
    • /
    • 2004
  • The hermetic rotary compressor is one of the most important components of an air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration occurs due to gas pulsation during the compression process and to unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify their sources and transmission path and effectively control them. Many approaches have been tried in order to identify the noise transmission path of a compressor. However, identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this study, the statistical energy analysis has been used to trace the energy flow in the compressor and to identify the transmission paths from the noise source to the exterior sound field.

차량용 유압 클러치시스템의 댐퍼실린더 특성해석 (Characteristic Analysis of the Damper Cylinder for the Automotive Hydraulic Clutch System)

  • 이춘태
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.151-158
    • /
    • 2008
  • The clutch system is a subcomponent of the transmission that is designed to engage and disengage power flow between the engine and the transmission. Recently, the engine power of automobile has been continuously increased because of customer's demand for the bigger one. As the engine power is increased, the vibration transmitted to the hydraulic clutch operating system has been increased. Therefore the demand for the reduction of clutch pedal vibration during the operation has been increased. This paper describes the pressure pulsation reduction characteristics of the damper cylinder which is applied to the hydraulic clutch operating system. And the purpose of this study is to propose an analysis model and investigate the effect of the design variable variations for the hydraulic clutch system. Especially, we studied the effect of damper cylinder parameter variations on the hydraulic clutch system performance.