• Title/Summary/Keyword: Flow of space

Search Result 2,709, Processing Time 0.034 seconds

Clinical Experience of Continuous Epidural Analgesia Using Baxter $Infusor^{(R)}$ (Baxter $Infusor^{(R)}$를 이용한 경막외 진통제 지속 주입)

  • Bae, Sang-Chull;Lee, Jang-Won;Kim, Ill-Ho;Song, Hoo-Bin;Park, Wook;Kim, Sung-Yell
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.127-132
    • /
    • 1991
  • Recently a non-electronic, disposable and portable infusor(Baxter infusor with patient control module, Baxter health care Co., Deerfield IL 60015 USA: BI $\bar{c}$ PCM) has been developed that will deliver both a continuous drug infusion as well as allow the patient to deliver extra doses of medication on a demand basis under predetermined limitation of analgesics. Patients may also not require as high analgesic dose rate to control pain when the acceptable and tolerable level of pain relief can be maintained by this device. From April l99l, we have used a total l93 units of BI $\bar{c}$ PCM. These units consisting of two components which one made by a balloon reservoir(capacity 65 ml, flow rate 0.5 ml/hr) to store medication and to regulate the pump power(490 torr), and another two PCMs to regulate additional analgesic administration by patients demand at intervals of 1S minutes and 60 minutes. The dose administered to the patient can be varied by changing the concentration of the infusate within the balloon reservoir. These devices were utilized for the pain control of 44 patients. These patients were divided into two groups. Twenty seven cases had cancer pain and 17 cases had non-cancer pain. The Touhy needle(No. l8 G.) tip was inserted into the epidural space and was used to guide the catheter to the spinal nerve level corresponding to the most painful area. The device was connected to the opposite site of the catheter tip and was filled with 60 ml of mixture solution such as 0.5% bupivacaine 15 ml, morphine HCl 10 mg, trazodone 10 ml, Tridol 3 ml and normal saline 31 ml were administed as the initial dose. When the initial dose was less effective, the next dose could be varied by increasing the concentration of bupivacaine, by adding more morphine (5~10 mg), and by reducing the volume of normal saline. Using these modules of drug self administration, we experienced the following: 1) Improvement of patient's self titration of analgesic requirement was provided. 2) The patients anxiety with pain recurrence resulting from delays in administering pain control medication was decreased significantly. 3) The working load accompanying with the single bolus injection as the usual method was reduced remarkably. 4) There was urinary retention in 5 cases and pruritus in 4 eases which developed as side effects but respiratory depression and vomiting was not encountered in a single case.

  • PDF

A Study on Structural Maintenance of 'Old Wall' Designated as National Registered Cultural Heritage (국가등록문화재로 지정된 옛 담장의 정비 양상)

  • So, Hyun-Su;Jeong, Myeong-Seok
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.41 no.1
    • /
    • pp.21-34
    • /
    • 2023
  • This study identified the materials and construction methods of 'Old Wall' in 13 villages which were designated as National Registered Cultural Heritage at the time of designation and examined the their structural changes based on field survey. The results are as follows: First, the 'Old Wall' consisted of 10 Soil-Stone Wall and 5 Stone Wall. At the time of designation, Stone Wall, which was built irregularly by dry-construction of natural stones, is similar in shape, but Soil-Stone Wall showed difference by the construction method of making used stones, joints, and faces. Second, the study extracted the changes of 'Old Wall' by repair and examined the changes of construction methods as well as the substitution and addition of materials of structure. The wall-roof was built with cement roof-tile and asbestos slate which have the advantage improve durability and cost-effectiveness. In addition, tile-mouth soil was added to korean traditional roof-tile to prevent rainwater from flowing in. Besides, to improve constructional convenience, the natural stone of the wall-body was replaced with blast stone, float stone and cut stone. Cement block, cement brick and cement mortar were frequently used to repair as well. As Soil-Stone Wall was transformed from irregular pattern-construction to comb pattern-construction and wet-construction was changed to dry-construction, it caused landscape and structural problems. Also, the layer of cement mortar applied to wall-foundation blocked the flow of rainwater that was induced by dry-construction of natural stones. Third, the study regarded that the problem with the repair of 'Old Wall' may occur as it is located in living space, because the owner of the wall could repair for the minor damages without technical knowledge. In addition, it is difficult for repair companies in charge of maintenance of Cultural Heritage to supply local materials, and it is differential construction specifications are not applied.

Exosome-derived microRNA-29c Induces Apoptosis of BIU-87 Cells by Down Regulating BCL-2 and MCL-1

  • Xu, Xiang-Dong;Wu, Xiao-Hou;Fan, Yan-Ru;Tan, Bing;Quan, Zhen;Luo, Chun-Li
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.8
    • /
    • pp.3471-3476
    • /
    • 2014
  • Background: Aberrant expression of the microRNA-29 family is associated with tumorigenesis and cancer progression. As transport carriers, tumor-derived exosomes are released into the extracellular space and regulate multiple functions of target cells. Thus, we assessed the possibility that exosomes could transport microRNA-29c as a carrier and correlations between microRNA-29c and apoptosis of bladder cancer cells. Materials and Methods: A total of 28 cancer and adjacent tissues were examined by immunohistochemistry to detect BCL-2 and MCL-1 expression. Disease was Ta-T1 in 12 patients, T2-T4 in 16, grade 1 in 8, 2 in 8 and 3 in 12. The expression of microRNA-29c in cancer tissues was detected by quantitative reverse transcriptase PCR (QRT-PCR). An adenovirus containing microRNA-29c was used to infect the BIU-87 human bladder cancer cell line. MicroRNA-29c in exosomes was measured by QRT-PCR. After BIU-87 cells were induced by exosomes-derived microRNA-29c, QRT-PCR was used to detect the level of microRNA-29c. Apoptosis was examined by flow cytometry and BCL-2 and MCL-1 mRNA expressions were assessed by reverse transcription-polymerase chain reaction. Western blotting was used to determine the protein expression of BCL-2 and MCL-1. Results: The expressions of BCL-2 and MCL-1 protein were remarkably increased in bladder carcinoma (p<0.05), but was found mainly in the basal and suprabasal layers in adjacent tissues. The expression of microRNA-29c in cancer tissues was negatively correlated with the BCL-2 and MCL-1. The expression level of microRNA-29c in exosomes and BIU-87 cells from the experiment group was higher than that in control groups (p<0.05). Exosome-derived microRNA-29c induced apoptosis (p<0.01). Although only BCL-2 was reduced at the mRNA level, both BCL-2 and MCL-1 were reduced at the protein level. Conclusions: Human bladder cancer cells infected by microRNA-29c adenovirus can transport microRNA-29c via exosomes. Moreover, exosome-derived microRNA29c induces apoptosis in bladder cancer cells by down-regulating BCL-2 and MCL-1.

Eco-friendly Design of Horticultural Complex through Application of Saemanguem Areas (시설원예 단지의 친환경적 조성 계획의 새만금지역 적용 연구)

  • Son, Jinkwan;Kang, Taegyoung;Kang, Donghyeon;Lim, Ryugab;Kim, Changhyun;PARK, Minjung;KONG, Minjae
    • Journal of Wetlands Research
    • /
    • v.22 no.4
    • /
    • pp.225-238
    • /
    • 2020
  • The agricultural landscape is considered an important space to provide service functions, but the reality is that environmental and ecological problems are being reported in the creation of a facility horticulture complex. Therefore, this study was conducted to contribute to sustainable agriculture by creating a more eco-friendly facility horticultural complex. The elements of planning for eco-friendly development of the facility horticultural complex were derived from literature and expert surveys. The master plan and the bird's-eye view were then applied to the Saemangeum area by applying the planning elements. After analyzing the method of selecting and deploying input elements for improving functions, it was suggested that low-flow areas, wetlands, artificial storage facilities, green spaces, and waterways should be placed in harmony with the landscape and that the building-to-land ratio should be applied at 55%. The final design was prepared by applying the ecological service function improvement plan proposed by experts. The final bird's-eye view also reflected water purification facilities, connection of wetlands to waterways, packing of pitchers, and connection of green areas. The results of the research are expected to be used as basic data for policy and budget allocation for the eco-friendly creation of horticulture facilities and contribute to sustainable agriculture by contributing to national biodiversity and environmental preservation.

Comparison of applicability of HVAC and air cleaners in a subway station platform against airborne infection of SARS-CoV-2 (지하역사 승강장에서 코로나19 바이러스 공기감염 대응 공기조화기와 공기청정기의 적용 효과 비교)

  • Lee, Gunhee;Kim, Sang Bok;Park, Inyong;Hong, Kee Jung;Lee, Yeawan;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2022
  • In this work, virion concentration and its dose changes by HVAC and air cleaners were estimated in a subway station platform to control airborne infection of SARS-CoV-2. Collection efficiencies with particle size were measured for the air filter equipped in a HVAC in one subway station in Daejeon. Indoor PM2.5 changes according to outdoor PM2.5 with time were also measured to estimate air infiltration rate in the subway station platform. When infected persons generate virions by 104, 105, 106, 3 × 106 and 5 × 106 h-1 in a 2,400 m3 volume platform, the concentration and dose were estimated as 9, 92, 275 and 458 virions/m3 and 4, 43, 130 and 217 virions after 1 hour exposure, respectively. The concentration and dose were reduced by 70%, and 64%, respectively by operations of both HVAC (with a flow rate of 16,000 m3/h, MERV 11) and ten air cleaners(with total CADR 10,740 m3/h) compared to those without operation of both HVAC and air cleaners. However, virion dose in the platform was estimated to be too low at the general conditions due to a large space, a high air infiltration (3 h-1) and a short residence time (usually < 10 mins) in the platform irrespective of the operations of HVAC or air cleaners. HVAC with filters and air cleaners would be more necessary in the concourse or shopping areas in the subway stations to reduce the infection dose from a few hundred to several tens virions in a hour.

A Study on the Relation Characteristics between Bubble Size Distribution and Floating Time (버블의 크기별 입도분포와 부상시간과의 상관특성에 관한 연구)

  • Jeon, Gun;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.277-281
    • /
    • 2017
  • Lately rainfall characteristics that it rains a lot in a short space of time often occurs. Because of this meteorological phenomena, the flow rate and concentration of initial rainfall for runoff and combined sewer overflows are changed. In the case of this inlet fluctuation, the flotation method at high surface loading rate is suitable for water quality management. the flotation method is able to meet the removal rate requirements of water public zone in 5 to 10 min which is irelatively short period. For assessment and diagonision of flotation method, A/S ratio is applied until now. But unfortunately, this has some limits for evaluation standard for certification and assessment of technical diagnosis and operation. This is why there is different efficiency in the bubble distribution at the same A/S ratio. The velocity and time of floating is changed by the different bubble distributions. The floating time affects the plant volume because the time factor make size dicision. Therefore the charateristics of bubble distribution and floating time at the same A/S ratio is necessary to apply to evaluation standard for certification and assessment of technical diagnosis and operation. For generalization of the method in certification and assessment, the characteristics of bubble distribution was studied. Until recently, using the optical device and shooting live video, there are some analysis technology of the floating factors. But this kind of technology is influenced by the equipment. with this level of confidence about the results, it is difficult to apply to generalize. According this reasons, this study should be applied on experiment generalization of method about measurement of relation between bubble distribution and floating time.

A Numerical Study on the Performance Analysis of a Solar Air Heating System with Forced Circulation Method (강제순환 방식의 공기가열식 태양열 집열기의 성능분석에 관한 수치해석 연구)

  • Park, Hyeong-Su;Kim, Chul-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.122-126
    • /
    • 2017
  • The aim of this study was to develop a device for solving the heating problem of living space using heated air, utilizing a simple air heater type collector for solar energy. At the present time, this study assessed the possibility of a development system through theoretical calculations for the amount of available energy according to the size change of the air-heated solar energy collector. To produce and supply hot water using the heat energy of the sun, hot water at $100^{\circ}C$ or less was produced using a flat or vacuum tube type collector. The purpose of this study was to research the air heating type solar collector that utilizes heating energy with heating air above $75^{\circ}C$, by designing and manufacturing an air piping type solar collector that is a simpler type than a conventional solar collector system. The analysis results were obtained for the generated air temperature ($^{\circ}C$) and the production of air (kg/h) to determine the performance of air heating by an air-heated solar collector according to the heat transfer characteristics in the collector of the model when a specified amount of heat flux was dropped into a solar collector of a certain size using PHOENICS, which is a heat flow analysis program applying the Finite Volume Method. From the analysis result, the temperature of the air obtained was approximately $40.5^{\circ}C$, which could be heated using an air heating tube with an inner diameter of 0.1m made of aluminum in a collector with a size of $1.2m{\times}1.1m{\times}0.19m$. The production of air was approximately 161 m3/h. This device can be applied to maintain a suitable environment for human activity using the heat energy of the sun.

Experimental Study on the Elastic Constants of A Transversely Isotropic Rock by Multi-Specimen Compression Tests Report 2 - Statistical Evaluation and Determination of True Values of Elastic Constants (다중시험편 시험에 의한 평면이방성 암석의 탄성상수 분석연구 제 2 보 - 자료의 통계적 평가와 참값의 결정)

  • Park, Chulwhan;Park, Chan;Jung, Yong-Bok
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.346-353
    • /
    • 2012
  • Multi-specimen uniaxial compression test has been carried out in order to find the method to determine the five independent elastic constants from a single standard specimen of a transversely isotropic rock. Total 35 specimens of 7 different angles from a large block of rhyolite presenting the flow structure obviously are used in tests. This second report is to focus on the statistical evaluation of measured strains and analyzed elastic constants. And the determination of their true or near-true values is discussed. As the result of RSD analysis, it turns out that the reliability of measured strains is sufficiently obtained and Saint-Venant approximation is well applicable except 15 degree angled specimen in tests. RSD is decreasing on the increase of the angle of anisotropy. This tendency may be caused not only by the decreasing of the deviation of measured strains, but also by the better applicability of Saint-Venant approximation on the increase of angle. It can be concluded that the analyzed values are considered the near-true ones of five independent constants on the high reliability. But the variation of the apparent Young's modulus expected by these values is not proved to match the measured tendency. It is inferred that the factor to decrease the apparent Young's modulus and/or to increase the shear strain, is present in the test or in the nature of the anisotropy in consideration of this inconsistency.

TREATMENT OF COMPOSITE RESIN RESTORATION WITH THE AIR ABRASIVE TECHNIQUE (Air abrasive technique을 이용한 복합레진 수복 증례)

  • Lee, Chang-Woo;Jang, Ki-Taeg;Lee, Sang-Hoon;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.763-770
    • /
    • 1997
  • The air abrasive technique is a non-mechanical method by which teeth are treated before restoration and stains and calculi are removed from tooth surfaces using the kinetic energy of small particles. The air abrasive technique in dentistry was first introduced in the 1950's with as instrument called 'Airdent'. But, as the main restorative materials of the period were amalgam and gold, and the instrument's inability to control the flow of particles caused the particles to be spread throughout the clinics, widespread use was not possible. In the 1990's, as these techincal problems were solved and more interest in new restorative materials rose in an effort to preserve sound tooth structure, new developements took place in instruments related to the air abrasive technique. The air abrasive technique produces less pressure, vibration and heat that might cause patient discomfort and facilitates the preservation of sound tooth structure. It also reduces the need for anesthesia and is less harmful to the pulp. Other advantages include increase in dentin bonding strength of composite resin, lower possibility of saliva contamination and maintenance of a dry field. But there is not direct contact between the nozzle and the tooth, the operator cannot use his or her tactile sense and must rely solely upon visual input. Other disadvantages are: the tooth preparation depends on the operator's ability; alpha-alumina particles, after bouncing off the tooth surface, cause damage to dental mirrors; the equipment is expensive and takes up a certain amount of space in the clinic. The author conducted case report using the air abrasive technique on patient visiting the Department of Pediatric Dentistry at Seoul National University Dental Hospital and arrived at the following conclusions. 1. The tooth preparation capability of different air abrasive devices varied widely among manufacturers. 2. It was more effective in treating early caries lesions and stains compared to lesions where caries had already progressed to produce soft dentin. 3. The cold stream and noise caused by the evacuation system was a major cause of discomfort to pediatric patients. 4. As there is no direct contact with tooth surface when using the air abrasive technique for tooth preparation, considerable experience and skill is required for proper tooth preparation.

  • PDF

Distribution and Statistical Analysis of Discontinuities in Deep Drillcore (심부시추코어를 활용한 불연속면의 분포 특성 및 통계학적 해석)

  • Junghae Choi;Youjin Jung;Dae-Sung Cheon
    • The Journal of Engineering Geology
    • /
    • v.34 no.3
    • /
    • pp.415-427
    • /
    • 2024
  • This study undertook a quantitative analysis of the distribution of fractures in deep drillcore from a Precambrian metamorphic complex on the north face of Hongcheon-gun, Gangwon-do, Korea. The fracture distribution with depth, inclination of fractures, and grain size in the fracture zone were measured and statistical techniques applied to derive probability distributions of fracture intervals. Analysis of the inclination angles of fracture planes showed that sub-horizontal fractures are dominant, and fracture spacing is mainly ≤0.5 m, with a median of 0.09 m, first quartile of 0.04 m, and third quartile of 0.18 m, indicating very dense fracture development. Statistical analysis of joint properties was undertaken with fitting using five probability density functions (double Weibull, exponential, generalized logistic, gamma, and lognormal). The lognormal distribution (sum of squared errors, SSE = 2.80) yielded the best fit based on the sum of residual squares. Quantitative characterization of the fracture characteristics of deep bedrock in the Hongcheon area is important for various geotechnical applications such as groundwater flow modeling, slope stability assessment, and underground structure design. In future studies, it will be necessary to combine in situ stress measurements and geophysical surveys to determine the relationship between fracture development and the local stress field.