A Study on Finned Tube Used in Turbo Refrigerator( I ) -for Condensation Hear Transfer- (터보 냉동기용 핀튜브에 관한 연구 ( I ) - 응축 열전달에 관하여 -)

  • Cho, Dong-Hyun;Han, Kyu-Il;Kim, Si-Young
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.5 no.1
    • /
    • pp.31-44
    • /
    • 1993
  • Through the early 1900's, the evolution of the surface condenser was closely tied to the development of steam engine and the turbine. As the chemical and petroleum industries evolved in the 1900's, the use of surface condensers in many different processes. Today, industry uses condensers in many shapes and sizes. The actual condensation process occurs on the outside surface of tubes. The nature of this surface geometry affects the condenser's heat transfer performance. The first condensers were built with plain tubes. As tube manufacturing techniques advanced, manufacturers started making tubes with integral fins. In the 1940's, fin densities were limited to about 600 to 700 fins per meter(fpm) because of manufacturing procedure. Today new manufacturing techniques allow production of tubes with fin densities ranging from 750 to 1600 fpm. The integral-fin tubes investigated in this paper are nominally 19 mm diameter. Eight tubes have been used with trapezodially shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. For comparison, tests are made using a plain tube having the same inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Betty and Katz's theoretical modelis is used to predict the R-11 condensation coefficient on horizontal integral-fin tubes having 748, 1024 and 1299 fpm. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken at steady state. The observed heat transfer enhancement for the finned and grooved tubes significantly exceeded that to be expected on grounds of increased area. For the eight fin tubes and one plain tube tested, the best performance has been obtained with a tube having a fin density of 1299 fpm, and a fin bight of 1.2mm and 30 grooves.

  • PDF

The Behaviour of Leachate by Rainfall in Sanitary Landfill Site (강우시 위생폐기물 매립지의 침출수 거동)

  • Bae, Il-Sang;Jung, Kweon;Kim, Dong-Il;Shin, Jai-Young;Jung, Il-Hyun
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.3
    • /
    • pp.148-157
    • /
    • 1998
  • Leachate is a result of the percolation of precipitation, uncontrolled runoff, and irrigation water into the landfill and can also include water initially contained in the waste as well as infiltrating groundwater. Behaviour of leachate by rainfall was studied to evaluate the variation of leachate generation and contaminants by rainfall in Sudokwon Landfill from January 1998 to October 1998. The quantity of leachate generated was measured with a flow meter, and the concentrations $BOD_5$, CODcr, T-N, $NE_3-N$, SS of leachate were also measured. Principal outcome obtained in this study are as follows : the quantity of leachate generated was the highest on August, the highest leachate generation volume in this period was 11,913㎥ and the lowest was $6,261m^3$. Although the similar amount of precipitation of 80mm applied to the two samples, there were difference in leachate generation due to precipitation duration, precipitation frequency, wet condition of solid wastes. As the result of regression analysis, the correlation coefficients(r) between the quantity of leachate generated and precipitation were 0.823, 0.976 between $BOD_5$ and CODcr, 0.992 between T-N and $NE_3-N$. As the quantity of leachate generated increased 48%, the concentration of $BOD_5$ and CODcr decreased 51% and 50% respectively. Therefore it was showed that the pollutant concentrations in leachate were diluted by precipitation. The concentrations of $BOD_5$ and COBcr in the rainy season were 2000~4000mg/1, 4000~6000mg/1 respectively, and 1000~3000 mg/1, 3000~5000 mg/l in the dry season. The loading of SS, $BOD_5$, CODcr(kg/month) on July was increased by 2.9 times, 2.8 times, 2.2 times with a basis on March. Therefore countermeasure of treatment facilities according to increase of loading by rainfall in summer is necessary.

  • PDF

Site Application Characteristics of Deep-Site Biopile System for Cleaning Oil-Contaminated Soil/Underground Water (유류오염 토양/지하수 정화를 위해 개발된 DSB(Deep-Site Biopile) System 현장적용특성)

  • Han Seung-Ho;Kong Sung-Ho;Kang Jung-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.2
    • /
    • pp.28-34
    • /
    • 2005
  • The aim of this article is to assess the application characteristics of the site by remediating oil-contaminated area using DSB (Deep-site Biopile) system. In the contaminated area, the soil was composed of penetrable sand and the leaked oil was spread widely (total 7,201 cubic meters) through 2.5 meter deep underground water flow. DSB system was operated for 30 minutes intervals for 24 hours in a day (30 minutes opεration and 30 minutes stop). To check contamination level change in the contaminated area after DSB system was operated, samples were taken. The result from the site shows that BTEX/TPH contamination level was dropped 50% after 30-day operation of DSB system, and that contamination level was dropped below contamination level check standard after 165 days and the remediation was completed. Unlike traditional biological remediation methods DSB system could efficiently process soil and water which were contaminated by high levels of oil compounds.

Quality Characteristics of Pear Jam with Added Ginger Powder (건조 방법을 달리한 생강가루를 첨가한 배잼의 품질 특성)

  • Rho, Jeong-Ok;Park, Hee-Jin;Lee, Young-Sook
    • The Korean Journal of Food And Nutrition
    • /
    • v.24 no.2
    • /
    • pp.159-165
    • /
    • 2011
  • This study was carried out to investigate the quality characteristics of pear jam containing fresh ginger(G1) and ginger powders; dried ginger powder(G2), freeze-dried ginger powder(G3), and hot-air dried ginger powder(G4). The moisture, crude protein, and crude ash content of the control group were significantly higher than those of the experimental groups (p<0.001, p<0.05, p<0.01). The pH of the dried ginger powder added jam(G2) was the lowest(p<0.05). Texture profile analysis found that the dried ginger powder added jam(G2) had the highest firmness, consistency, cohesiveness, and resistance to flow/viscosity among all samples(p<0.001). Regarding the spread-meter value of the pear jam, the control group (G1) and hot air-dried ginger powder added jam(G4) had the highest values. The dried ginger power added jam(G2) had the lowest value among the samples(p<0.01). Regarding the color values of the pear jam, the control group(G1) had the highest L and b values. Hot-air dried ginger powder added jam(G4), on the other hand, had the lowest(p<0.001). The opposite was true for a value: hot-air dried ginger powder added jam(G4) had the highest. From the sensory evaluation, a positive trend was observed for the appearance of the dried ginger powder added jam(G2)(p<0.001). For sweetness, the dried ginger powder added jam(G2) had the highest value. A positive trend was observed for the overall acceptability of the dried ginger powder-added jam(G2)(p<0.001). Therefore, the dried ginger powder-added sample(G2) seemed to be the most appropriate to make pear jam with high acceptability.

Daily Water Intake and Exposure Parameters Related to the Multi-route Exposure in Drinking Water (음용수의 섭취량 및 다경로 노출평가를 위한 노출변수 조사연구)

  • Chung, Yong;Shin, Dong-Chun;Park, Seong-Eun;Choi, Shi-Nai;Park, Seon-Mee
    • Environmental Analysis Health and Toxicology
    • /
    • v.11 no.1_2
    • /
    • pp.19-29
    • /
    • 1996
  • Human exposure to volatile compounds in tap water can occur from inhalation and dermal absorption as well as direct ingestion. The relative contribution to total human exposure from these pathways has been considered to be important especially for VOC's (volatile organic compounds). In an attempt to reduce the uncertainty of the risk assessment, it has been suggested that the exposure assessment process could be significantly improved by adopting Monte-Carlo simulation. However, there is no actual data in Korea for each exposure parameter to determine the level of exposure, and the distributional pattern. Therefore, we surveyed water use patterns and behavior related to multi-route exposure to VOC's in household tap water in Korea, and compared these values to the those in western countries. In the first survey, we calculated daily water intake using data from a sample of 1322 persons of several cities in Korea. In the second survey, we obtained questionnaire data on exposure time for showering, bathing and household activities, and tap water intake from 851households in Korea. In the last survey, we measured the exposure parameters (exposure time, water use rate etc.) related to showers, baths, toilets, dish washing, washing and cooking, and tap water intake was surveyed. Also, the subjects were measured their body weight, height and tidal volume, etc. A diary, a flow meter and a measuring cup were used to measure these values as precisely as possible. Average daily water intake was ranged 0.79-1.71 L/day for adults in three surveys. Tap water intake measured by log-sheet during one week in third survey was 1.26 (average), 1.98 L/day (90 percentlie), respectively. These results were comparable with results from EPA (1.4, 2L/day). The average amount of water used by housewives in the third survey was 515.0 $\pm$ 564.6L/day. In usual activity, the amount of water used in the bathroom, the laundry and the kitchen was 140.0 $\pm$ 538.9, 148.0 $\pm$ 174.5, 229.3 $\pm$ 205.4 L/day, respectively. Exposure parameters such as water intake rate, exposure duration, body weight, inhalation rates in surveyed data of Korean people differed from those published from western countries. This could be attributed to variations in lifestyle, dietary habits and physiological characteristics.

  • PDF

Analysis of Seawater Transport based on Field Measurements at Pier-bridge between Busan New-port and the Nakdong River Estuary (부산 신항-낙동강 하구역 연결잔교부의 물질수송 해석(I) - 현장조사를 통한 잔교부 해수소통량 평가 -)

  • Lee, Young-Bok;Tawaret, Attapon;Kim, Heon-Tae;Yoon, Han-Sam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.14 no.3
    • /
    • pp.189-195
    • /
    • 2008
  • This study analyzed the characteristics of sea water transport between Busan New-port and the Nakdong River estuary. A current meter was placed on a pier bridge and the current velocity was analyzed to determine the flow direction. Water temperature, salinity, turbidity, and tide were also measured to determine the characteristics of sea water and to describe the tidal current between the two regions. The results indicated that the dominant outflow direction of the ebb tidal current was from the Nakdong River estuary to Busan New-port. Conversely, during a flood tide, the dominant direction was from Busan New-port to the Nakdong River estuary. The maximum current speed during the first and second field measurements was about 13.18 and 30.80 cm/ sec, respectively. During the first field measurement, the total volume of sea water transport was $184.71\;m^3/sec$ and the residual volume transport was $+59.74\;m^3/sec$. By contrast, during the second field measurement, the respective values were $331.15\;m^3/sec$ and $28.88\;m^3/sec$.

  • PDF

Assessment for Inhalation Exposure to Trihalomethanes (THMs) and Chroline and Efficiency of Ventilation for an Indoor Swimming Pool (일개 실내수영장의 공기 중 염소 및 트리할로메탄의 노출평가 및 환기 효율 평가)

  • Park, Hae-Dong;Park, Hyun-Hee;Shin, Jung-Ah;Kim, Tae-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.5
    • /
    • pp.402-410
    • /
    • 2010
  • The objectives of this study were to evaluate the air quality surrounding an indoor swimming pool, to estimate the cancer risk based on the airborne exposure to trihalomethanes (THMs), and to examine the ventilation efficiency by Computational Fluid Dynamics (CFD). Chlorine and THMs were measured poolside, and in the staff room and reception area. The indoor swimming pool was modeled using the Airpak program, with ventilation drawings and actual survey data. Temperature, flow and mean age of the air were analyzed. Levels of chlorine poolside, and in the staff room, and reception area were $203\;{\mu}g/m^3$, $5\;{\mu}g/m^3$, and $10\;{\mu}g/m^3$, respectively. Chloroform was the dominant THM in all sampling sites and mean concentrations were $16.30\;{\mu}g/m^3$, $0.51\;{\mu}g/m^3$, and $0.06\;{\mu}g/m^3$ poolside, in the staff room and reception area, respectively. Bromodichloromethane and Dibromochloromethane levels were respectively estimated as $10.3\;{\mu}g/m^3$ and $1.7\;{\mu}g/m^3$ poolside, $1.3\;{\mu}g/m^3$ and $0.1\;{\mu}g/m^3$ in the staff room, and were not detected in the reception area. The cancer risks from inhalation exposure to THMs were estimated between $3.37{\times}10^{-7}$ and $1.84{\times}10^{-5}$. A short circulation phenomenon was observed from the supply air vents to the exhaust air vents located in the ceiling. A high temperature layer was formed within one meter of the ceiling, and a low temperature layer was formed under this layer due to the low velocity and high temperature of the supply air, and the improper locations of the supply air vents and exhaust air vents. The stagnation was evident at the above adult pool and the mean age of the air was 22 minutes. Disinfection by-products in the indoor swimming pool were present in higher concentrations than in the outdoor air. In order to increase the removal of pollutants, adjustment was required of the supply air volume and the supply/exhaust position.

RCCA End-Tip Examination by ECT (원자로 제어봉 End-Tip 원주방향균열 와전류검사)

  • Lee, H.J.;Nam, M.W.;Jung, G.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.6
    • /
    • pp.455-463
    • /
    • 1998
  • RCCA(rod cluster control assembly) End-Tip suffers from neutron irradiation and constant vibration due to high-speed internal flow of primary coolant during plant operation. Such operating conditions cause the RCCA end-tip crackings around tile circumferential weldment of the end-tip, and in some cases, the defective end-tips were completly broken loose. However, no reliable inspection techniques for end-tip crackings were developed in the past, although some techniques exist for inspecting RCCA control rod wears. Therefore, NDE group at KEPRI has developed an ECT technique for the detection and the sizing of the end-tip crackings. The technique uses a specially designed surface-riding probe that can detect size of circumferential crackings with an accuracy of ${\pm}5.31%$ RMS error. This paper describes the ECT instrumentation including the ECT probes, calibration bars, as well as technical approaches.

  • PDF

Evaporation Heat Transfer Characteristics of Carbon Dioxide in a Diameter Tube of 4.57mm (내경 4.57mm 관내 CO2의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.574-579
    • /
    • 2008
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 4.57mm. The experiments were conducted at mass flux of 400 to $900kg/m^2s$, saturation temperature of 5 to $20^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much. In comparison with test results and existing correlations, All of the existing correlations for the heat transfer coefficient underestimated the experimental data. However Jung et al.'s correlation showed a good agreement with the experimental data. Therefore, it is necessary to develope accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in horizontal tubes.

Triboelectrostatic Separation of Unburned Carbon from Flyash for Ash Recycling (마찰대전 정전분리기를 이용하여 석탄회에 함유된 미연탄소분 제거에 관한 연구)

  • 이재근;김성찬;손낙원;김두현;오정근
    • Resources Recycling
    • /
    • v.6 no.3
    • /
    • pp.15-21
    • /
    • 1997
  • Flyash from a coal-hed power plan1 is produced approximtcly 3 million tons m 1996 and causes the serious environmentalpmblem due to the disposal in the ash pond. Flyash is an accepted additive in concrete where it adds strength, sulfate ateresistanceand reduced cost, provided acccptablc levcls of unbunrned carbon are mmtmed This papzr describes to investigate thc technicalfeasibility of a dry triboelcctrostatlcp roccss to scparate unburned carbon h m f lyash into economically valuable produck Puliclesof unburned carbon and flyash can be impded positivc and negative surface charzes. rcapeclively. with a copper tniochargcr dueto dirferences in the work function values of thc particles and the tnbacharger. and cm he separated by passing thcm throuph anexternal electic field. A laboratory s d e separation system consists of r sacw feeder for ash supply, a tniocharger, verticalcollecling copper plates, power supplies, a flow meter, and a fan. Separation tests taking into account separahian efficiency and ashrecovery showed that flyash recovery was sh-nngly dependent an thc tnbocharger geomzhy, elect"c ficld strength. flyssh s ~ c a,n dash feeding late. Optimal separation conditions were flyash size less than 125 Fm and electric field shcngrh of 200 kV1m. Ovcr 80%of the flyash with 7% lass on ignition was recovered at wrbon contznts less than 3%bon contznts less than 3%

  • PDF