• 제목/요약/키워드: Flow meter

검색결과 595건 처리시간 0.033초

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Lee Dong-Geon;Son Chang-Hyo;Oh Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.297-305
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter. a pre-heater and evaporator (test section). The test section consists of a smooth. horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500\;kg/m^{2}s$. saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$. and heat flux of 10 to $40\;kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greatly effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality. heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In making a comparison between test results and existing correlations. the present experimental data are the best fit for the correlation of Jung et al. But it was failed to predict the evaporation heat transfer coefficient of $CO_2$ using by the existing correlation. Therefore. it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

Evaporation Heat Transfer Characteristics of $CO_2$ in a Horizontal Tube

  • Son Chang-Hyo;Kim Dae-Hui;Choi Sun-Muk;Kim Young-Ryul;Oh Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권4호
    • /
    • pp.167-174
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $500kg/m^2s$, saturation temperature of $-5^{\circ}C\;to\;5^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has greater effect on nucleate boiling than convective boiling. The evaporation heat transfer coefficient of $CO_2$ is highly dependent on the vapor quality, heat flux and saturation temperature. The evaporation heat transfer coefficient of $CO_2$ is very larger than that of R-22 and R-134a. In comparison with test results and existing correlations, the best fit of the present experimental data is obtained with the correlation of Jung et al. But the existing correlations failed to predict the evaporation heat transfer coefficient of $CO_2$. Therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

공간분활 및 영역열량측정에 의한 공평 자동난방운영시스템 구현 (System Implementation for Fair Automatic Heating Operation Based on Spatial Distributing and Zonal Calorie Measuring)

  • 한상철;류광렬
    • 한국정보통신학회논문지
    • /
    • 제23권8호
    • /
    • pp.910-916
    • /
    • 2019
  • 본 논문은 주거공간영역 별로 사용 난방열량을 측정하고 사용량을 자동으로 측정 분석하여 계량 운영 할 수 있는 공평관리 자동난방운영시스템의 구현이다. 난방공간은 4영역으로 분할하여 하나의 계량기로 유량과 열량이 계측된다. 이 시스템은 열량검출, 온도조절기, 밸브제어기, PC컨버터와 모니터링으로 구성된다. 난방 공간영역은 실내온도에 따라 열량 계산에 필요한 환수 온도가 측정되고 영역별 열량이 산출된다. 실험결과, 측정기기로 계측한 값과 비교하여 측정열량 값의 오차 범위는 1% 내이다. 기존의 유량계를 이용한 난방 분할 방식과 비교하면 난방 에너지 사용 비용이 약 7% 저감된다. 이 공평시스템은 향후에는 BEMS와 공동으로 연계하는 연구가 필요하다.

Durometer를 이용한 고유동 콘크리트의 응결시간 판정 방법 (Estimation of the Setting Time of the High Flowing Concrete Using Durometer)

  • 한민철;신용섭;한인덕
    • 대한건축학회논문집:구조계
    • /
    • 제35권9호
    • /
    • pp.143-150
    • /
    • 2019
  • 본 연구는 고무경도계인 Durometer를 사용하여 콘크리트의 표면마감 작업시간 결정과 관련있는 응결시간을 판정하는 방법에 대하여 제안하고자 하였다. 연구의 결과로 Durometer 사용시 모르타르와 콘크리트의 두가지 요소 모두에서 Proctor 관입저항기와 높은 상관성이 있는 것으로 분석되어 Durometer를 사용한다면 콘크리트의 과학적이고 정량적인 응결시간을 확인 할수 있을 것이라 판단된다. 따라서 Durometer C 타입의 경우는 초결 측정으로 40 HD로 하여 마감작업 가능 시간결정에, D 타입의 경우는 10 HD로 하여 종결시간 측정으로 마감작업의 한계시간, 양생개시 시간 확인 등에 유용하게 활용될 수 있는 것으로 판단된다.

양평지역 땅밀림 재발생지의 지형 및 지반 특성 분석 (Analysis of Topography and Ground Characteristics of Landcreep Reoccurrence in the Yangpyeong Area)

  • 박재현;이상현
    • 한국산림과학회지
    • /
    • 제111권2호
    • /
    • pp.263-275
    • /
    • 2022
  • 본 연구는 경기도 양평군에서 발생한 땅밀림 재발생지의 지질, 지형, 토양의 물리적 특성을 분석하여 땅밀림 복구대책 수립을 위한 기초자료를 제공하기 위하여 실시하였다. 조사대상지역은 표토층, 풍화토, 풍화암 및 연암층으로, 기반암으로 셰일이 분포하고, 사암이 협재하는 철(凸)상 대지상지형으로 붕적토땅밀림지역이었다. 조사대상지역에서 신축계 및 변위측정기는 땅밀림이 재발생한 시기인 2020년 7월 1일부터 8월 27일까지 1.1~6.5 mm 변화하여 땅밀림의 영향이 나타났다. 땅밀림은 S65° W, E45° S, E70° S 두 방향으로 진행되었으며, 지하수의 유향분석 결과인 주 흐름방향 E82.5° S, S16.8° W와 유사하여 지하수의 유출방향으로 땅밀림이 발생하는 것으로 분석되었다. 땅밀림지의 평균산지경사는 19.3°로 우리나라의 평균산지경사(25°)보다 낮은 완경사지에서 발생하였으며, 지하수가 유출되는 지역에서는 토양의 용적밀도가 낮게 나타났다.

경동맥 혈전 유발 동물모델을 이용한 한약재 추출물의 효능 검색 (Screening of Anti-thrombotic Activity of Herbal Extracts in Ferric Chloride-induced Thrombosis Model)

  • 박인실;이기모;이인선;한재일;전원경
    • 대한본초학회지
    • /
    • 제28권5호
    • /
    • pp.33-38
    • /
    • 2013
  • Objectives : The aim of this study was to examine anti-thrombotic effect of traditional herbal extracts in a rat model of ferric chloride ($FeCl_3$)-induced carotid arterial thrombosis. Methods : Thirty minutes prior to a 35% $FeCl_3$ application, Sprague Dawley(SD) rats were injected with the 10 types of traditional herbal extracts (100mg/kg, intraperitoneal injection), respectively. The effect of these herbal extracts was examined for time to occlusion(TTO) using the Laser doppler flow meter and measured for thrombus weight (TW) in $FeCl_3$-induced thrombosis model. Results : In the TTO, Salvia miltiorrhiza (Sm, $2.30{\pm}0.28$ min, p<0.001) and Santalum album (Sa, $2.19{\pm}0.19$ min, p<0.001) showed significantly delayed TTO more than twice compared with Saline-treated group. Cnidium officinale (Co), Psoralea corylifolia (Pc), Scutellatia baicalensis (Sba), Panax notoginseng (Pn), Angelica tenuissima (At), Scrophularia buergeriana (Sbu), Rhus verniciflua (Rv) and Picrasma quassioides (Pq), except for Rhus verniciflua (Rv) also meaningfully impeded TTO more than one fold. In addition, Salvia miltiorrhiza, Santalum album, Cnidium officinale, Psoralea corylifolia and Scutellatia baicalensis significantly reduced TW more than 10% compared with Saline-treated group. Especially, Salvia miltiorrhiza and Santalum album showed the most excellent anti-thrombotic effect among the 10 herbal extracts tested on the restoration of altered TTO and TW. Conclusions : These results suggest that Sm and Sa extracts have outstanding anti-thrombotic effect in $FeCl_3$-induced thrombosis model and is potentially useful as herbal medicines for the treatment and prevention of thrombosis.

바이오매스 합성가스 적용을 위한 LPG 엔진발전기 개조 및 성능평가 (Modification of an LPG Engine Generator for Biomass Syngas Application)

  • 엘리에젤 하비네자;홍성구
    • 한국농공학회논문집
    • /
    • 제64권5호
    • /
    • pp.9-16
    • /
    • 2022
  • Syngas, also known as synthesis gas, synthetic gas, or producer gas, is a combustible gas mixture generated when organic material (biomass) is heated in a gasifier with a limited airflow at a high temperature and elevated pressure. The present research was aimed at modifying the existing LPG engine generator for fully operated syngas. During this study, the designed gasifier-powered woodchip biomass was used for syngas production to generate power. A 6.0 kW LPG engine generator was modified and tested for operation on syngas. In the experiments, syngas and LPG fuels were tested as test fuels. For syngas production, 3 kg of dry woodchips were fed and burnt into the designed downdraft gasifier. The gasifier was connected to a blower coupled with a slider to help the air supply and control the ignition. The convection cooling system was connected to the syngas flow pipe for cooling the hot produce gas and filtering the impurities. For engine modification, a customized T-shaped flexible air/fuel mixture control device was designed for adjusting the correct stoichiometric air-fuel ratio ranging between 1:1.1 and 1.3 to match the combustion needs of the engine. The composition of produced syngas was analyzed using a gas analyzer and its composition was; 13~15 %, 10.2~13 %, 4.1~4.5 %, and 11.9~14.6 % for CO, H2, CH4, and CO2 respectively with a heating value range of 4.12~5.01 MJ/Nm3. The maximum peak power output generated from syngas and LPG was recorded using a clamp-on power meter and found to be 3,689 watts and 5,001 watts, respectively. The results found from the experiment show that the LPG engine generator operated on syngas can be adopted with a de-ration rate of 73.78 % compared to its regular operating fuel.

CFR 법에 의한 산화아연 박막의 제조 및 황 화합물 검출을 위한 전기적 특성 (Preparation of Zinc Oxide Thin Film by CFR Method and its Electrical Property for Detection of Sulfur Compounds)

  • 이선이;박노국;윤석훈;이태진
    • Korean Chemical Engineering Research
    • /
    • 제48권2호
    • /
    • pp.218-223
    • /
    • 2010
  • 본 연구에서는 반도체식 가스센서 재료로서 활용 가능한 ZnO 박막을 Continuous Flow Reaction(CFR) 방법으로 실리콘 기판 위에 성장시켰다. 또한 전구물질로 사용한 zinc acetate의 농도에 따른 산화아연 박막의 성장특성과 이들의 전기적 특성이 조사되었다. 산화아연 박막 제조는 0.005~0.02 M의 zinc acetate 농도에서 수행되었다. 산화아연 박막을 구성하고 있는 ZnO의 입자크기는 농도가 증가할수록 증가되었으며, 박막의 두께도 함께 증가되었다. CFR 법에 의한 산화아연 박막의 성장속도는 전구물질의 농도에 비례적으로 의존되는 것을 확인하였으며, 균일한 박막을 제조하기 위한 전구물질의 최적 농도는 0.01 M이였다. 한편, 전구물질의 농도를 달리하여 제조된 산화아연 박막의 전압에 대한 전류를 I-V 측정기로 측정한 결과, 박막의 두께가 증가될수록 높은 전류가 흘렀다. 그러므로 산화아연 박막의 전류를 전구물질의 농도변화로 조절할 수 있다. 또한 산화아연 박막을 $300^{\circ}C$에서 5 min 동안 $500ppmv\;H_2S$에 노출시킨 결과, 전압에 대한 전류값이 낮아졌다. 이와 같이 산화아연의 전기적 특성은 가스센서로 응용할 수 있는 가능성을 확인시켜 주는 결과라 할 수 있다.

우리나라 항만의 벙커 품질관리시스템 개선방안 (Improving Policy of Bunker Quality Management System in Korean Ports)

  • 김형태
    • 한국항만경제학회지
    • /
    • 제38권2호
    • /
    • pp.11-30
    • /
    • 2022
  • 우리나라 항만의 벙커링은 품질과 수량 측면에서 큰 문제를 안고 있다. 벙커의 품질은 우수하다고 평가받고 있으나, 벙커링 절차측면의 품질에는 허점이 많이 발생하고 있다. 특히 저유기지에서 벙커를 급유바지에 선적하고, 본선으로 운반하며, 본선으로 공급하는 과정의 공급망에 있어서는 품질이 확보되고 있지 않다, 벙커수량 측면에서는 문제가 더욱 심각하다. 벙커수량 분쟁이 매우 빈번하고, 잔량발생 및 도유현상까지 일상화되어 있다. 여기에는 벙커링 운송료가 낮다는 것이 주요 원인으로 작용하고 있음을 부인할 수 없다. 그러나 운송료 문제가 해소된다고 하여 벙커량 문제가 완벽하게 해결된다고 보기 힘들다. 이에 따라 이 연구는 현행 벙커링 공급과 관련된 품질 미확보 문제와 수량분쟁을 해결하여 벙커 선진항만으로 발전할 수 있는 방안을 모색·제시하였다. 이 연구에서는 벙커링이 이루어지는 현장 위주의 분석을 통해 현황 및 문제점을 면밀하게 분석하고, 벙커 선진항만인 싱가포르의 사례를 심도깊게 분석, 시사점을 활용하였다. 분석 결과 벙커공급절차에 있어서는 공급망의 품질강화제도를 도입하고, 벙커수량 측면에서는 현행 사운딩 방식에서 질량유량계 시스템으로 계측방식의 전환이라는 혁신적인 방안을 제시하였다.

비접촉식 유속계의 표면유속을 이용한 유량산정방법에 관한 연구 (An Study on flow Discharge Calculation using Surface Velocity)

  • 노영신;이신재;김대영
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2020년도 학술발표회
    • /
    • pp.230-230
    • /
    • 2020
  • 하천 유량측정을 위한 표면유속계는 비접촉식 방식이기 때문에 현장에서의 측정이 간편하고, 비교적 안전하기 때문에 홍수시 유량측정에 널리 이용되고 있다. 비접촉식 유속계가 가지고 있는 이러한 장점으로 전자파표면유속계의 활용이 점차 증가하고 있으며, 영상유속계와 같은 비접촉 측정방식의 활용방안 마련에 대한 연구개발 등이 꾸준히 진행되어 왔다. 최근에는 고정식으로 상시 운영이 가능한 표면유속계 등이 출시되어 소규모 하천이나 수로에서의 상시 유량측정에 활용되고 있다. 다만, 이러한 비접촉식 유속계는 표면의 유속을 측정하기 때문에 유량산정을 위해서는 평균유속으로의 환산이 필요하지만, 현재까지는 평균유속 환산계수를 사용하여 표면유속을 평균유속으로 환산하는 방법이 유일하게 활용되고 있다. 하지만, 실제 하천에서는 단면 및 하도형태, 하상조건, 수리특성 및 유속분포 등의 다양한 조건에 따라 환산계수가 결정되기 때문에 이를 단순히 일률적으로 적용하는 것은 곤란하며, 이로 인해 과거 오랫동안 표면유속을 평균유속으로 환산하기 위한 다양한 연구가 진행되었지만, 실제 다양한 조건의 하천에 적용할 수 있는 표준화된 방법은 아직까지 제시되지 못하고 있다. 현재까지, 고정식으로 설치된 유속계로부터 측정된 유속을 평균유속으로 환산하는 방법으로는 국내외적으로 지표유속법(Index Velocity Method)과 유속분포법(Velocity Profile Method)이 대표적이며, H-ADCP (Horizontal-Acoustic Doppler Velocity Profiler) 또는 UVM(Ultrasonic Velocity Meter) 등과 같은 초음파유속계를 활용한 자동유량측정시설의 유량산정방법으로 활용되고 있다. 이러한 방법들은 고정된 유속계의 측정유속을 지표유속(Vi)으로 하여 다양한 범위의 실측된 평균유속과의 관계를 개발하여 활용하거나, 지표유속을 매개로 개수로 단면의 이론적인 유속분포를 추정하여 평균유속을 산정한다. 이러한 지표유속을 활용하는 방법들에서 공통적으로 중요한 것은 하천단면의 최대유속(Vmax)이 가장 좋은 지표유속이라는 것이다. 따라서 국제기준에서는 지표유속을 측정하는 유속계의 가장 바람직한 위치로 유심부(core flow)를 권장하고 있다. 하지만, 접촉식 유속계의 경우 유심부 설치가 매우 어렵고 많은 비용이 들기 때문에, 비접촉식 유속계를 활용하여 하천단면의 최대유속을 측정할 수 있다면, 가장 효율적인 고정식 측정방법이 될 수 있을 것이다. 따라서, 본 연구에서는 비접촉식 표면유속계의 고정식 유량측정 활용성 및 적용성을 검토할 목적으로 표면유속에 대한 유량산정방법을 검토하였다. 이를 위해 24GHz의 주파수를 갖는 레이다표면유속계인 Sensoflow를 낙동강 수계 길안천에 위치한 안동시(대사3교)에 고정설치하여 표면유속을 지표유속으로 수집하였다. 다양한 유량규모에서 측정한 실측 표면유속과 수집된 표면유속을 지표유속으로 활용하여 지표유속관계를 개발하였으며, 산정된 유량을 기존 수위-유량관계곡선식의 환산유량과 비교하여 표면유속의 지표유속 활용성을 검토하였다.

  • PDF