• Title/Summary/Keyword: Flow meter

Search Result 595, Processing Time 0.026 seconds

Application of Automatic Stormwater Monitoring System and SWMM Model for Estimation of Urban Pollutant Loading During Storm Events (빗물 자동모니터링장치와 SWMM 모델을 이용한 강우시 도시지역 오염부하량 예측에 관한 연구)

  • Seo, Dongil;Fang, Tiehu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.373-381
    • /
    • 2012
  • An automatic flow and water quality monitoring system was applied to estimate pollutant loads to an urban stream during storm events in DTV (Daeduk Techno Valley), Daejeon, Korea. The monitoring system consists of rainfall gage, ultrasonic water level meter, water quality sensors for DO, temperature, pH, conductivity, turbidity and automatic water sampler for further laboratory analysis. All data are transmitted through on-line system and the monitoring system is designed to be controlled manually in the field and remotely from laboratory computer. Flow rates were verified with field measurements during storm events and showed good agreements. Automatic sampler was used to collect real time samples and analyzed for BOD, COD, TN, TP, SS and other pollutant concentrations in the laboratory. SWMM (Storm Water Management Model) urban watershed model was applied and calibrated using the observed flow and water quality data for the study area. While flow modeling results showed good agreement for all events, water quality modeling results showed variable levels of agreement. These results indicate that current options in the SWMM model to predict pollutant build up and wash-off effects are not sufficient to satisfy modeling of all the rainfall events under study and thus need further modification. This study showed the automatic monitoring system can be used to provide data to assist further refinement of modeling accuracy. This automatic stormwater monitoring and modeling system can be used to develop basin scale water quality management strategies of urban streams in storm events.

A Study on the Acute Effects of Eine Particles on Pulmonary Function of Schoolchildren in Beijing, China (봄철 미세분진이 북경시 아동 폐기능에 미치는 급성영향에 관한 연구)

  • 김대선;유승도;차정훈;안승철;차준석
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.140-148
    • /
    • 2004
  • To evaluate the acute effects of fine particles on pulmonary function, a longitudinal study was conducted. This study was carried out for the schoolchildren (3rd and 6th grades) living in Beijing, China. Each child was provided with a mini-Wright peak flow meter and a preformatted health symptom diary for 40 days, and was trained on their proper use. Participants were instructed to perform the peak flow test three times in standing position, three times a day (9 am, 12 pm, and 8 pm), and to record all the readings along with the symptoms (cold, cough, and asthmatic symptoms) experienced on that day. Daily measurement of fine particles (PM$_{10}$ and PM$_{2.5}$) was obtained in the comer of the playground of the participating elementary school for the same period of this longitudinal study. The relationship between daily peak expiratory flow rate (PEFR) and fine particle levels was analyzed using a mixed linear regression models including gender, height, the presence of respiratory symptoms, and daily average temperature and relative humidity as extraneous variables. The total number of students participating in this longitudinal study was 87. The range of daily measured PEFR was 253-501$\ell$/min. In general, the PEFR measured in the morning was lower than the PEFR measured in the evening (or afternoon) on the same day. The daily mean concentrations of PM$_{10}$ and PM$_{2.5}$ over the study period were 180.2$\mu\textrm{g}$/㎥ and 103.2$\mu\textrm{g}$/㎥, respectively. The IQR (inter-quartile range) of PM$_{10}$ and PM$_{2.5}$ were 91.8$\mu\textrm{g}$/㎥ and 58.0$\mu\textrm{g}$/㎥. During the study period, the national ambient air quality standard of 150$\mu\textrm{g}$/㎥ (for PM$_{10}$) was exceeded in 23 days (57.5%). The analysis showed that an increase of 1$\mu\textrm{g}$/㎥ of PM$_{10}$ corresponded to 0.59$\mu\textrm{g}$/㎥ increment of PM$_{2.5}$. Daily mean PEFR was regressed with the 24-hour average PM$_{10}$ (or PM$_{2.5}$) levels, weather information such as air temperature and relative humidity, and individual characteristics including gender, height, and respiratory symptoms. The analysis showed that the increase of fine particle concentrations was negatively associated with the variability in PEFR. The IQR increments of PM$_{10}$ or PM$_{2.5}$ (at 1-day time lag) were also shown to be related with 1.54 $\ell$/min (95% Confidence intervals: 0.94-2.14) and 1.56$\ell$/min (95% CI: 0.95-2.16) decline in PEFR.R.ine in PEFR.ine in PEFR.

Annual Change of Peak Expiratory Flow Rate in Asthma and COPD (천식환자 및 만성 폐쇄성 폐질환환자군에서 연간 최대 호기유속의 변화량)

  • Hong, Sung-Chul;Lee, Cho-I;Han, Jang-Soo;Kim, Won-Dong;Lee, Kye-Young;Kim, Sun-Jong;Kim, Hee-Joung;Ha, Kyoung-Won;Chon, Gyu-Rak;Yoo, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.1
    • /
    • pp.24-29
    • /
    • 2012
  • Background: Measurement of peak expiratory flow rate (PEFR) in a follow-up examination for a chronic airway disease is useful because it has the advantages of being a simple measurement and can be repeated during examination. The aim of this study was to examine the annual decrease of PEFR in asthma and chronic obstructive pulmonary disease (COPD) patients and to confirm the factors which influence this decrease. Methods: From May, 2003 to September, 2010, the annual decrease of PEFR was obtained from asthma and COPD patients attending an outpatient pulmonary clinic. PEFR was measured using a Mini-Wright peak flow meter (Clement Clarke International Ltd. UK), and we conducted an analysis of factors that influence the change of PEFR and its average values. Results: The results showed an annual decrease of $1.70{\pm}12.86$ L/min the asthmatic patients and an annual decrease of $10.3{\pm}7.32$ L/min in the COPD patients. Age and $FEV_1$ were the predictive factors influencing change in asthma, and $FEV_1$ and smoking were the predictive factors influencing change in COPD. Conclusion: We confirmed the annual decreasing PEFR in patients with chronic airway disease and identified factors that work in conjunction with $FEV_1$ to influence the change.

Changes of Current and Wave Patterns Depending on Typhoon Pathways in a Shallow Channel between Jeju and Udo Island (태풍 경로에 따른 제주 우도수로에서의 해류와 파랑 특성 변화)

  • Hong, Ji-Seok;Moon, Jae-Hong;Yoon, Seok-Hoon;Yoon, Woo Seok
    • Ocean and Polar Research
    • /
    • v.43 no.4
    • /
    • pp.205-217
    • /
    • 2021
  • A shallow channel between Jeju and Udo Islands, which is located in the northeastern Jeju Island, is influenced by storm- or typhoon-induced currents and surface waves as well as strong tidal currents. This study examines the typhoon-induced current and wave patterns in the channel, using Acoustic Doppler Current Meter (ADCP) measurements and an ocean-wave coupled modeling experiment. Three typhoons were chosen - Chaba (2016), Soulik (2018), and Lingling (2019) - to investigate the responses of currents and waves in their pathways. During the pre-typhoon periods, dominant northward flow and wave propagation were observed in the channel due to the southeasterly winds before the three typhoons. After the passage of Chaba, which passed over the eastern side of Jeju Island, the northward flow and wave propagation were totally reversed to the opposite direction, which was attributed to the strong northerly winds on the left side of the typhoon. In contrast, in the cases of Soulik and Lingling, which passed over the western side of Jeju Island, strong southerly winds on the right side of the typhoons continuously intensified the northward current and wave propagation in the channel. The model-simulated current and wave fields reasonably coincided with observational data, showing southward/northward flow and wave propagation in response to the right/left side of the typhoon pathways. Typhoon-induced downwind flows, and surface waves could enhance up to 2m/s and 3m due to the strong winds that lasted for more than 12 hours. This suggests that the flow and wave patterns in the Udo channel are highly sensitive to the pathway of typhoons and accompanying winds; thus, this may be a crucial factor with regard to the movement of seabed sediments and subsequent coastal erosion.

A development of new dielectric tracer test method for groundwater logging: laboratory soil column test (지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발)

  • Kim Man-Il;Kim Hyoung-Soo;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.301-311
    • /
    • 2004
  • This study is suggested a new dielectric tracer test method to understand geological structure of porous media and groundwater flow to use the dielectric constant which is one of electrical special quality of various geological materials. To measure their parameters, tracer material is made an ethanol mixing liquid(EML) having a same specific gravity of water. Also, soil materials are prepared a dielectric tracer test using the FDR system that could measure dielectric constant for saturated standard sand and river sand layers which have different initial porosity. To compare with their results, we discussed with the concentration variation of saline water having a saline concentration $3\%$ which is general tracer material by using the electro multi-meter system in the laboratory or field test. In two tracer experiment results, EML tracer test could confirm definitely EML concentration variation from each saturated soil layer as standard and river sands. However, tracer test of saline water $3\%$ concentration could not confirm permeating movement of water by degree of salinity change because these are settled at lower part column in a whole column area continuously. These causes are that specific gravity of saline water is heavier than water. That is, it could know that deposition of saline water is composed of lower part of soil column continuously independently of the direction of water into saturated soil material.

The Study on the Analysis of Stormwater Runoff Using RMS (Remote Monitoring System) (원격수위계측기를 이용한 강우유출 분석에 관한 연구)

  • Ham, Kwang-Jun;Kim, Joon-Hyun;Yi, Geon-Ho;Choi, Ji-Yong;Jeong, Ui-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.13 no.6
    • /
    • pp.285-294
    • /
    • 2004
  • The purpose of this study is to understand the quantitative change of water resources using RMS(Remote Monitoring System) which takes real time data with high reliability. Also, the characteristic of stormwater runoff was understood by the application of the above system for three streams (Jiam, Yulmun, and Gongji stream) in Chuncheon City. The detailed results of these studies are as follows; RMS(Remote Monitoring System) was constructed by the combination of the automatic water-level meter, which measures water-level of streams at all times, and the wireless communication system sending real-time data from the meter. This system is used to evaluate the stormwater runoff in watersheds and the quantitative changes of streams. It is possible to overcome the limit of field investigations needed, which takes a lot of manpower and time, and it is very efficient to provide the reliable flowrate data. Also, it can be applied to the disaster prevention system for flood because the change of flowrate in stream is monitored at real-time. For 3 streams with different watershed characteristics, correlation equations induced from the relation analysis results. In terms of the relation between water-level and flowrate, flowrate was increased rapidly as the water-level rises in case of small watershed and steep slope. The application results of the proposed system for 3 streams (Jiam, Yulmun, Gongji) in Chuncheon city are as follows; The remote monitoring system was very useful for acquisition of the flow rate in stream that are basic data to understand pollutants runoff in watershed. In case of no-rainy day, the runoff ratio for pollutant loading rate was the highest level in Yulmun stream(BOD:2.3%, TN:20.2%, TP:1.2%). So, it shows the management of pollution source is needed such as rehabilitation of sewer line. Runoff ratio of total phosphorus by rainfall in Gongji watershed was increased about 19 times than no-rainy day, which is estimated as the influence of sewer overflow.

A Study on Liquified Petroleum Gas(LPG) Fuel Quantitative Method using Coriolis Mass Flowmeter (코리올리 질량유량계를 이용한 액화석유가스(LPG) 정량 측정 방법 연구)

  • Park, Tae-Seong;Seong, Sang-Rae;Yim, Eui-Soon;Lee, Joung-Min;Lee, Myung-Sig;Kang, Hyung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.109-122
    • /
    • 2018
  • Domestic LPG meters are being tested for LPG quantification in accordance with the "Measures Act". The LPG meter is re-tested every three years in accordance with the "Enforcement Decree of the Measures Act". The maximum permissible error within the test is within ${\pm}1.0%$, and the tolerance is within ${\pm}1.5%$. For the quantitative measurement of LPG, a hydrometer for LPG, a balance, and a pressure vessel are used. The volume of LPG varies in depending on the temperature and pressure. The current quantitative measurement method of LPG requires the measurement of temperature, pressure and density in order to determine the volume of LPG, respectively, and some equipments are needed accordingly. Coriolis mass flowmeter, on the other hand, measure the mass flow, density and temperature at the same time, and can be converted and calculated to the required values using a computer program, also it is widely applied in the industrial field. In this study, the volume of LPG was measured using a Coriolis mass flowmeter as a basic study of LPG quantitative measurement. In addition, it is shown that it is possible to apply for the LPG quantitative measurement using the Coriolis mass flowmeter by comparing it with the conventional LPG quantitative measurement method.

Groundwater Flow Analysis in Fractured Rocks Using Zonal Pumping Tests and Water Quality Logs (구간양수시험과 수질검층자료에 의한 균열암반내 지하수 유동 분석)

  • Hamm, Se-Yeong;Sung, Ig-Hwan;Lee, Byeong-Dae;Jang, Seong;Cheong, Jae-Yeol;Lee, Jeong-Hwan
    • The Journal of Engineering Geology
    • /
    • v.16 no.4 s.50
    • /
    • pp.411-427
    • /
    • 2006
  • This study aimed to recognize characteristics of groundwater flow in fractured bedrocks based on zonal pump-ing tests, slug tests, water quality logs and borehole TV camera logs conducted on two boreholes (NJ-11 and SJ-8) in the city of Naju. Especially, the zonal pumping tests using sin91e Packer were executed to reveal groundwater flow characteristics in the fractured bedrocks with depth. On borehole NJ-11, the zonal pumping tests resulted in a flow dimension of 1.6 with a packer depth of 56.9 meters. It also resulted in lower flow dimensions as moving to shallower packer depths, reaching a flow dimension of 1 at a 24 meter packer depth. This fact indicates that uniform permissive fractures take place in deeper zones at the borehole. On borehole SJ-8, a flow dimension of 1.7 was determined at the deepest packer level (50 m). Next, a dimension of 1.8 was obtained at 32 meters of packer depth, and lastly a dimension of 1.4 at 19 meters of packer depth. The variation of flow dimension with different packer depths is interpreted by the variability of permissive fractures with depth. Zonal pumping tests led to the utilization of the Moench (1984) dual-porosity model because hydraulic characteristics in the test holes were most suitable to the fractured bedrocks. Water quality logs displayed a tendency to increase geothermal temperature, to increase pH and to decrease dissolved oxygen. In addition, there was an increasing tendency towards electrical conductance and a decreasing tendency towards dissolved oxygen at most fracture zones.

Comparison of the Efficiency between a Remodeled Bubble Generating Pumps for an Aquarium Fish and the Existed Commercial Air Sampler for the Sampling of Ambient Air Asbestos (공기 중 석면농도 분석시 관상어용 기포발생기를 개조한 장치와 기존의 상업용 시료 채취기와의 성능 비교)

  • Jang, Bong-Ki;Tak, Hyun-Wook;Song, Su-Jin;Jo, Bong-Hyun;Kim, Yeong-Ji;Son, Bu-Soon;Lee, Jong-Wha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.492-500
    • /
    • 2014
  • Objectives: The purpose of this study is to estimate the applicability of regional sample collection of environmental samples. The concentration of asbestos fibers were analyzed with two devices. One was an existing commercial air sampling pump that has been proved to be accurate and exact, and the other is a remodeled pump for sample collection which was made from an electric bubble generator originally designed for aquarium fish. Samples were collected with the two devices under the same environmental conditions and collection equipment. A comparative analysis of the concentration of ambient asbestos fiber was then performed. Methods: Based on previous research, six farmhouses with asbestos fiber slate roofs known to have high concentrations of asbestos fiber were selected. Using the existing commercial air sampling pump and the remodeled electric bubble generator, four to seven samples were collected each day one meter downwind from the edge of the slate roof at high volume (about 4 L/min) and low volume (about 1.4 L/min). The analyzer responsible for sample quality control of asbestos fibers counted the number of asbestos fibers with a phase microscope. Results: The rates of flow change of the existed sampler and the remodeled pump at high volume were 0.82% and 0.17%, respectively. The rates of flow change at low volume were 3.83% and 1.09%, but there was not significant difference. The rates of flow change are within the error range (${\pm}5%$) of OSHA analyzing methods. For the high volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 6.270 fibers/L and for the remodeled one 5.527 fibers/L, not a significant difference. For the low volume sampler, the average asbestos fiber concentration in the air collected by the existed sampler is 7.755 fibers/L and for the remodeled one 7.706 fibers/L, not a significant difference. The total area of the slate roof of the targeted farmhouse has an effect on the concentration of asbestos fibers in the air from the existing pump and the remodeled one (p<0.01). Conclusions: The sampling function between the existing commercial pump and the remodeled one shows little difference. Therefore, the remodeled pump is considered a pump with a good availability for collecting ambient air asbestos samples.

A Study for the Water Rising Effect on Flood Water Level by Debris (유송잡물에 의한 홍수위 상승 영향분석 - 삽교천의 선우대교를 중심으로 -)

  • Cho, Yong-Ho;Jeong, Sang-Man;Han, Kyu-Ha;Shin, Kwang-Seob
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.5
    • /
    • pp.179-186
    • /
    • 2007
  • This paper has investigated a rise of water level in upstream and downstream of bridge, which is caused by accumulation of debris in a bridge. The debris has been classified into several types in terms of size. The rise of water level which has been caused by installation and removal of sheet pile that is used to block water in a bridge has been analyzed using HEC-RAS model. According to the analysis, it has turned out that the debris has no influence on the rise of water level in ordinary water flow. In addition, sheet pile has little impact on the rise of water as well. Even though the impact of sheet file has turned out trivial in flood flow just like the ordinary water flow, it's been simulated that the maximum water level difference between upstream and downstream of bridge turned out more than 1.0meter because of debris in 80-year or more flood frequency. When the rise of water level in upstream from the cross section of the bridge was investigated based on 100-year flood frequency, besides, it has turned out that it had an influence up to 17.84km distance because of the effect of debris.