• 제목/요약/키워드: Flow meter

검색결과 595건 처리시간 0.021초

현장여건에 따른 터빈 유량계와 오리피스 유량계의 정확도 비교 (A Comparison of Accuracy Between a Turbine and an Orifice Meter in the Field)

  • 안승희;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.97-105
    • /
    • 1999
  • Orifice flow meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice flow meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested in the standard manuals, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the more the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

열전달 질량유량계 개발 (Development of Thermal Mass Flow Meter)

  • 지대성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.118-122
    • /
    • 1999
  • Thermal mass flow meter was developed using principle of convective heat transfer. The advantage of thermal mass flow meter is measuring mass flow directly, therefore, it is not required to use densitometer or temperature/pressure and DP gages. The final accuracy of this thermal mass flow meter is $\pm1.0{\%}$ or better, reproducibility is $\pm0.2{\%}$, and the response time is 600 ms. The thermal mass flow meter was developed from a single point to multi-points (maximum is 9 points), and the number of points is determined according to desired accuracy and size of piping/duct. Since this thermal mass flow meter adopted microprocessor based design, it is intrinsically accurate, self-error detectable, and has self-diagnosis function. The applications of this thermal mass flow meter are for measurement and control of HVAC air flow, other gas flow, and liquid flow.

  • PDF

전달 시간차 방식 초음파 가스 유량계 (Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference)

  • 박상국;황원호
    • 제어로봇시스템학회논문지
    • /
    • 제9권9호
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

SI엔진의 정상상태 유량 특성에 관한 실험적 연구 (An Experimental Study of the Air Flow Rate Characteristics at Steady State in an SI Engine)

  • 박경석;고상근;노승탁;이종화
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.1-12
    • /
    • 1997
  • In an SI engine, the characteristics of the air flow is important not only for the design of the intake system geometry but also for the accurate measurement of the induction air mass. In this study, an air flow rate measurement using the ultrasonic flow meter and hot wire flow meter was conducted at the upstream of the intake port and the throttle. At the upstream of the intake port, the pulsating flow into the cylinder affected by the pressure wave was detected directly with the flow meters instead of pressure sensors. At the upstream of the throttle, the reverse flow phenomena were showed by comparing the flow pattern measured by the hot wire air flow meter and the ultrasonic air flow meter. The results of this study can be used for the analysis of the tuning effect in the intake manifold and estimation of the error in real time measurement for the air flow rate.

  • PDF

오리피스 유량계와 터빈 유량계의 직관부길이와 유동안정기에 관한 연구 (A Study of Straight Pipe Length and Straightener in Orifice Meter Turbine Meter)

  • 허재영;안승희;이강진;이승준
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.265-271
    • /
    • 2000
  • Orifice meters and turbine meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate and also to analyze flow measurement errors of the turbine meter with and without straightener. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested In the standard, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the mon the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

MR 센서와 PIC를 이용한 비접촉식 정밀 유량계 개발에 관한 연구 (A Study on Development of a Noncontact Precision Flow-meter Using MR Sensor and PIC)

  • 이승희;이민철;고석조;장용석;최문호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1063-1066
    • /
    • 2003
  • A flow-meter and its measurement controller was developed for a hydraulic system. This study, for development of positive displacement flow-meter, consist of PIC(Peripheral Interface Controller) controller with MR(Magneto-resistive) sensors. This flow-meter is used valve position indicator for valve control system by hydraulic. The MR sensors are used for the rotation of OVAL gear that detecting device. In the ship environments, consideration that necessary explosive proof. Thus electro device or electro flow-meter needs explosion design for electric circuit. We designed noncontact type flow-meter and evaluated the safety and measuring abilities.

  • PDF

유량측정 기기별 측정성과에 대한 실험적 비교분석 (Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters)

  • 이재혁;이석호;정성원;김태웅
    • 한국습지학회지
    • /
    • 제12권1호
    • /
    • pp.95-103
    • /
    • 2010
  • 유량자료는 물의 순환과정을 규명하고 효율적인 수자원 개발 및 이수 치수 계획 등에 매우 귀중하게 이용된다. 그러나 이러한 유량자료를 확보하는데 많은 시간과 경비 등이 요구되기 때문에 주요 수위에서 유량자료는 수위-유량관계곡선식(Stage-Discharge Curve)을 개발하여 유량을 산정하고 있다. 따라서 수위-유량관계곡선식의 신뢰도는 유량자료의 품질에 절대적인 영향을 미치는 요인으로 작용된다. 수문학을 전공하고 연구하는 많은 학자들은 고품질의 유량자료를 생산하여 신뢰성 있는 곡선식을 개발하고자 유량측정 방법과 기준, 장비개발 및 개량 등에 관한 연구를 수행하고 있다. 현재 국내에서는 다양한 유량측정기기를 사용하여 유량자료를 생산하고 활용하고 있으나, 측정기기별 정확도 및 실험적 측정성과에 대한 연구자료가 미흡한 실정이다. 본 연구에서는 규격화된 콘크리트 수로에 일정한 유량을 흘려보내는 조건에서 다양한 측정기기를 이용하여 유속을 측정하였다. 그리고 이 측정성과를 이용하여 유량을 산정하고 비교분석하였다. 실험을 위해서 국내에서 일반적으로 사용되고 있는 측정기기로 프라이스 유속계(USGS Type AA Current Meter), 휴대용 유량계(Flow Meter), 초음파식 디지털 유속계(ADC), C2 유속계(C2 Small Current Meter), 플로우 트렉커(Flow Tracker), 마그네틱 유속계(Electromagnetic Current Meter) 등의 장비를 사용하여 유량을 산정하였으며, 각 기기별 산정된 유량을 비교 분석 하였다. 비교검토에 적용하고자 측정한 수심으로는 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m의 왕복측정 6-Case로 진행이 되었으며, 신뢰성과 정확도를 높이기 위해 도섭법으로 수면에서 0.6d 지점의 유량측정방법(1점법)을 적용하였다. USGS Type AA Current Meter, Flow Meter, ADC, C2 Small Current Meter는 유속측정기기의 검교정을 받았으므로 다른 실험유량측정치의 비교를 위한 기준값으로 사용하였다. 따라서 국내에서 널리 사용되는 측정기기(USGS Type AA Current Meter, Flow Meter, ADC, C2 Small Current Meter, Flow Tracker, Electromagnetic Current meter)별 검토 결과 평균유량 및 평균유속에 있어 프라이스 유속계를 기준으로 마그네틱 유속계 $\pm$ 10 % 이상, 플로우 트렉커 $\pm$ 10 % 미만, 휴대용 유량계, 초음파식 디지털 유속계 및 C2 유속계는 $\pm$ 5 % 미만의 차이가 있음을 확인할 수 있었다.

$Annubar^{(R)}$형 차압유량계 형상 개선에 따른 유량 특성 연구 (A Study on Flow Rate Characteristics of a $Annubar^{(R)}$ Type Differential Pressure Flow Meter with a Shape Improvement)

  • 오대산;이충훈
    • 한국생산제조학회지
    • /
    • 제19권2호
    • /
    • pp.204-210
    • /
    • 2010
  • The inner structure of the triangular separate bar (TSB) was improved to enhance the productivity of the TSB flow meter by simplifying the machining process for making the flow meter. The cross section of upstream and downstream pressure chamber in the TSB was changed from triangle to circle, which make it possible to substitute the wire cutting by drilling in the process of machining the pressure chamber. The flow rate characteristics of the flow meters was calibrated with a laminar flow meter. Six kinds of flow meters whose diameters of pressure tap for measuring pressure of both upsteam and downstream pressure chamber were different one another were made. The effects of the pressure tap diameter on the flow rate characteristics of the TSB flow meter was little. The mass flow rate characteristics of the flow meters with increasing a non-dimensional parameter which includes the gas temperature, exhaust gas pressure and differential pressure at the flow meters and atmospheric pressure shows nearly linear relationship with a correlation coefficient of R=0.998.

초음파센서를 이용한 전자식 연료분사엔진의 흡기유량측정 (Air Flow Rate Measurement in Multi Point Injection Engine U sing Ultrasonic Sensors)

  • 박경석;김중일;고상근;노승탁;이종화
    • 한국자동차공학회논문집
    • /
    • 제3권3호
    • /
    • pp.58-65
    • /
    • 1995
  • In this study an air flow meter was developed for MPI engine using ultrasonic sensors. The major characteristcs of the ultrasonic flow meter are high speed response, flow direction recognition and linear output. The air flow rate measurements were conducted at upstream of the throttle and intake manifold. The characteristics of the ultrasonic flow meter are compared with those of the Bosch hot wire flow meter at both steady and unsteady engine conditions.

  • PDF

디젤엔진 배기 가스 유량 측정용 삼각 분리 막대형 차압유량계 유량 특성 연구 (A Study on Flow Characteristics of a Separate Triangular Bar Differential Pressure Flow Meter for Measuring Exhaust Flow Rate of Diesel Engine)

  • 이충훈;김광일;김민창;박동선
    • 한국철도학회논문집
    • /
    • 제10권5호
    • /
    • pp.563-568
    • /
    • 2007
  • 디젤 엔진의 배기가스 유량을 측정하기 삼각 분리 막대형 차압유량계를 개발하였다. 3 종류의 삼각 막대형 차압유량계를 제작하였고 실험 평가하였다. 삼각 막대형 외부형상이 유선형에 가까울수록 차압유량계에서의 상류부 와 하류부의 차압이 감소하는 경향을 나타내었다. 삼각막대형 차압유량계를 사용하여 고온 및 상온 조건에서 유량 검정을 하였다. 고온 조건에서의 유량계 검정을 위해 버너를 제작하였다. 삼각막대형 상류부 및 하류부 간의 차압과 질량 유량의 실험식을 구했다. 또한 실험식은 기체 온도에 의한 보정을 포함하고 있다.