• 제목/요약/키워드: Flow measurement

검색결과 3,192건 처리시간 0.031초

계장용 볼 밸브 유량계수 Cv 측정에 관한 연구 (A Study of the Measurement of the Flow Coefficient Cv of a Ball Valve for Instrumentation)

  • 강창원;이중섭;장세민;이치우
    • 한국기계가공학회지
    • /
    • 제18권3호
    • /
    • pp.103-108
    • /
    • 2019
  • The results of the measurement of the flow-rate coefficient (Cv-value) and the analysis of a small ball valve are summarized follows. The Cv-values of 1/2-, 3/4- and 1-inch ball valves were measured using a flow-rate measurement test. The manufacturer obtained the Cv-value using a theoretical calculation method. The new experimental measurement and analysis method yielded more reliable results. In addition, the Cv value obtained through numerical analysis was almost identical the value provided by the manufacturer, which was based on experimental results. A Study on Flow Analysis results are all similar appearances as the reliability of the results.

일체형원자로에서 냉각재펌프의 전력측정을 이용한 실시간 유량산정 방법에 관한 연구 (The Study on a Real-time Flow-rate Calculation Method by the Measurement of Coolant Pump Power in an Integral Reactor)

  • 이준;윤주현;지성균
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.161-166
    • /
    • 2003
  • It is the common features of the integral reactors that the main components of the RCS are installed within the reactor vessel, and so there are no any flow pipes connecting the coolant pumps or steam generators. Due to no any flow pipes, it is impossible to measure the differential pressure at the RCS of the integral reactors, and it also makes impossible measure the flow-rate of the reactor coolant. As a alternative method, the method by the measurement of coolant pump power has been introduced in this study. Up to now, we did not found out a precedent which the coolant pump power is used for the real-time flow-rate calculation at normal operation of the commercial nuclear power plants. The objective of the study is to embody the real-time flow-rate calculation method by the measurement of coolant pump power in an integral reactor. As a result of the study, we could theoretically reason that the capacity-head curve and capacity-shaft power curve around the rated capacity with the high specific-speeded axial flow pumps have each diagonally steep incline but show the similar shape. Also, we could confirm the above theoretical reasoning from the measured result of the pump motor inputs, So, it has been concluded that it is possible to calculate the real-time flow-rate by the measurement of pump motor inputs. In addition, the compensation for a above new method can be made by HBM being now used in the commercial nuclear power plants.

  • PDF

가스 유량 계측 및 제어 시스템 연구 (Development of a Gas Flow Measurement and Control System)

  • 전학진;양종화
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.255-259
    • /
    • 1996
  • This paper describes a system for measurement and control of a gas flow. In order to measure the flux of gas and control a vavle according to flux, this system was developed. This system is implemented on the personal computer and its environment is developed tool called TMS. This system includes a main program and Tele-Metering Unit for transmitting correcting flow value based on temperature and pressure in flow computer and AD converter for transmitting instantaneous flow rate, temperature and pressure as interface part of personal computer. This system was made by Visual C++ program. Using this system, inspected data for the recognition of transmitting flow value are generated on the screen, file and printer. The activity, reliability of this system was verified on Daegu-Citygas that aids the system for the acquisition of inspected data by realtime application.

  • PDF

계단형상에 의한 스풀밸브의 유동력 보상 (Flow force compensation by stepped spool)

  • 신원규;최현영;신효필;문의준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.745-749
    • /
    • 2002
  • This paper is on the study of flow force compensating method of spool type valve. A simple flow force compensating method using stepped spool is presented in this paper. It is easy to manufacture stepped spool in the presented method because the shape of it is simple. The method has the merit that the size of valve need not be increased. Actuating force required for driving means of spool can be decreased by the compensation of flow force. The effect of presented method is predicted through CFD analysis. The prototypes of flow force compensating Direct Drive Servo-Valve where the result of CFD analysis is reflected are manufactured, and the measurement of flow force is carried out. It is known from the measurement that the effect of flow force compensation is very similar to from CFD analysis.

  • PDF

유로망 해석에 의한 윤활유 공급펌프 성능 해석 (Performance Analysis of the Lubricating Oil Feed Pump by the Anslysis of the Flow Network)

  • 길두송;이영호
    • 동력기계공학회지
    • /
    • 제6권4호
    • /
    • pp.62-67
    • /
    • 2002
  • In this paper, the cause of the discrepancy of the inlet and outlet flow of the lubricating oil feed pump was analyzed by the flow measurement and the analysis of the flow network. At first, we thought that the flow difference was induced by a leak in the middle of the flow network. But, through the flow measurement using ultrasonic flow meter and the performance analysis of the pump, we knew that the cause of the flow difference was due to a drop in efficiency of the pump according to the pressure drop of the outlet. Also, we knew that the shape of the piping had no effect on the efficiency of the pump.

  • PDF

흡수용액의 In-line 농도측정을 위한 기초연구 (A Preliminary Study on the In-line Concentration Measurement of Absorbent Solution)

  • 민병혁;황덕용;정시영;구기갑
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.152-158
    • /
    • 2003
  • Titration method is one of the widely used methods for the concentration measurement of absorbent ammonia/water. However, this method is inconvenient because the solution should be extracted for the measurement. Moreover, significant error can be introduced by the evaporation of ammonia during the sampling and measuring procedure. In this study a reliable in-line concentration measurement method was proposed. To prove the validity of the concept, a measuring apparatus was designed, built, and tested with water. It is found that the location of flow inlet and exit is important in the measurement accuracy. The flow inlet and exit located in the middle of the test cell showed the best result. By the error analysis, it is expected that the ammonia concentration can be measured within the error of $\pm$0.18% assuming the error of 0.1 K in temperature measurement and 0.1 g in weight measurement.

유속 및 파이프 두께 측정 겸용 초음파 트랜스듀서 개선 (Improvement of an Ultrasonic Transducer for Measuring Both Flow Velocity and Pipe Thickness)

  • 김주완;김진오
    • 한국소음진동공학회논문집
    • /
    • 제26권2호
    • /
    • pp.148-156
    • /
    • 2016
  • The paper deals with improvement of a piezoelectric ultrasonic transducer for measuring both pipe thickness and flow velocity. The transducer structure is based on the conventional transducers for measuring flow velocity by obliquely transmitting ultrasonic waves to the flow direction. The transducer invented earlier for measuring flow velocity and pipe thickness had an advantage of including only one piezoelectric disc, but for the thickness measurement the ultrasonic wave had to be reflected twice in a wedge material to be transmitted vertically to a pipe, and thus the wave signal was too weak. The transducer has been improved to transmit waves for thickness measurement vertically to a pipe without any prior reflection by electrically connecting two piezoelectric discs, one for flow velocity and the other for pipe thickness measurement. By comparing the measured results of specimen thickness with the improved transducer and conventional transducers, the accuracies of the improved one have been evaluated in the pipe thickness measurements.

디지털영상처리기술을 이용한 비접촉식 유체-구조물 연동운동 3차원 측정시스템 개발에 관한 연구 (A Study on the Development of a Three-dimensional Measurement System for Flow-Structure Interaction Using Digital Image Processing)

  • 도덕희;조효제;상지웅;황태규;조용범;편용범
    • 한국해양공학회지
    • /
    • 제18권4호
    • /
    • pp.1-7
    • /
    • 2004
  • A simultaneous measurement system that can analyze the flow-structure interaction has been developed. This system consists of four CCD cameras, two for capturing instantaneous flow fields and two for tracking a solid body. The three-dimensional vector fields around a cylinder are measured, while the motion of the cylinder forced by the flow field is measured, simultaneously, with the constructed system. The cylinder is suspended in the working fluid of a water channel, and the surface of the working fluid is forced sinusoidally to make the cylinder bounced. Reynolds number for the mean main stream is about 3500. The interaction between the flow fields and the cylinder motion is examined quantitatively.

KOLAS 교정기관의 측정동등성 확립을 위한 물유량 숙련도 시험 (Proficiency Test of Water Flow Rate for Measurement Equivalence Among KOLAS Accredited Laboratories)

  • 전세종;윤병로;김수진
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제5권2호
    • /
    • pp.105-113
    • /
    • 2017
  • 한국인정기구(KOLAS)는 아시아태평양인정협의체(APLAC)에 소속되어 있으며, 측정 결과를 SI 단위로 소급하고 이를 유지시키기 위해 교정기관 인정제도를 운영하고 있다. 2016 년 6 월 현재, 22 개의 기관이 KOLAS 물유량 분야 교정기관으로 지정되어 있다. 이 중 12 개 KOLAS 교정기관들이 한국계량측정협회(KASTO)가 2015 년에 주관한 물유량 숙련도 시험(PM2015-08)에 참가했다. 이번 숙련도 시험은 KOLAS 교정기관들의 교정측정능력(CMC)을 고려하여 3 가지의 유량 범위($3.6m^3/h{\sim}12m^3/h$, $40m^3/h{\sim}80m^3/h$, $40m3/h{\sim}200m^3/h$)에서 실시되었다. 숙련도 시험의 목적은 참가기관들의 CMC 가 기준시험소(KRISS)의 CMC 와 비교하여 측정동등성이 성립하는지 여부를 판단하기 위한 것이다. 측정동등성은 측정동등성지수(number of equivalence; $E_n$)를 산출하여 평가했다. ${\mid}E_n{\mid}$ < 1 일 때, 측정동등성이 확립된다고 판단했다. 이번 시험에서 12 개 KOLAS 교정기관 모두 기준시험소와 측정동등성이 성립함을 확인했다.

Experimental Approach to Equalizing the Orifice Method with the Throughput One for the Measurement of TMP Pumping Speed

  • Lim, J.Y.;Kang, S.B.;Shin, J.H.;Koh, D.Y.;Cheung, W.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.18-18
    • /
    • 2010
  • Methods of the characteristics evaluation of turbo-molecular pumps (TMP) are well-defined in the international measurement standards such as ISO, PNEUROP, DIN, JIS, and AVS. The Vacuum Center in the Korea Research Institute of Standards and Science has recently designed, constructed, and established the integrated characteristics evaluation system of TMPs based on the international documents by continuously pursuing and acquiring the reliable international credibility through measurement perfection. The measurement of TMP pumping speed is normally performed with the throughput and orifice methods dependent on the mass flow regions. However, in the UHV range of the molecular flow region, the high uncertainties of the gauges, mass flow rates, and conductance are too critical to precisely accumulate reliable data. With UHV gauges of uncertainties less than 15% and a calculated conductance of the orifice, about 35% of pumping speed uncertainties are experimentally derived in the pressure range of less than $10^{-6}$ mbar. In order to solve the uncertainty problems of pumping speeds in the UHV range, we introduced an SRG with 1% accuracy and a constant volume flow meter (CVFM) to measure the finite mass flow rates down to $10^{-3}$ mbar-L/s with 3% uncertainty for the throughput method. In this way we have performed the measurement of pumping speed down to less than $10^{-6}$ mbar with an uncertainty of 6% for a 1000 L/s TMP. In this article we suggest that the CVFM has an ability to measure the conductance of the orifice experimentally with flowing the known mass through the orifice chambers, so that we may overcome the discontinuity problem encountering during introducing two measurement methods in one pumping speed evaluation sequence.

  • PDF