• Title/Summary/Keyword: Flow line

Search Result 2,340, Processing Time 0.03 seconds

Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner for different refrigerant flow rates with high-head and long-line conditions (동시냉난방 시스템 에어컨의 냉매량 변화에 따른 고낙차 장배관 운전 신뢰성 평가)

  • Lee, Seung-Chan;Kim, Tae-An;Tae, Sang-Jin;Jung, Gyoo-Ha;Moon, Je-Myung;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.304-309
    • /
    • 2008
  • The heating and cooling performances of system multi-air conditioner for various refrigerant flow rates with high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, and the two different adjustments of refrigerant flow rates were +20 % and -20 %, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with two different refrigerant flow rates. Especially, the oil level in the compressor was normally maintained at the safety zone. Experimental results were prepared on the p-h diagram.

  • PDF

Experimental Study on Noise Reduction of Fan for Automotive Air Conditioner (차량용 공조 팬의 소음 저감에 대한 실험적 연구)

  • Lee, Jin-Kab;Chung, Byung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.51-56
    • /
    • 2013
  • This paper is the experimental study to investigate the noise sources location in order to reduce the noise level of line flow fan for the air conditioner in the subway car. The noise of line flow fan is caused by various factors such as the turbulence by air flow, random noise, noise of blade passing frequence(681Hz) and noise due to structural vibration of rotor unbalance(28.4Hz) by motor revolution. By performing the noise reduction on each sound source, the noise level is decreased as much as 5.7dB(A) through the controls of housing guide angle and distance, the configuration changes of flow passage shape and rotor balancing.

Comparison of Flow Line Layout and Fixed-Position Layout in a Rail Vehicle Assembly Factory (철도차량 의장공장에서 흐름라인방식과 고정위치형 배치방식의 비교)

  • Moon, Dug Hee;Son, Dong Su;Lee, Young Hoon;Shin, Yang Woo
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.3
    • /
    • pp.117-129
    • /
    • 2018
  • In this paper we will discuss two different layout concepts which can be applied to rail-vehicle assembly factory. The existing system is based on the traditional flow line, and the suggested system is based on the fixed position layout. The main factors which affect on the system performances are the variation of process time, shortage rate of part and the shortage period. Simulation experiments indicate that the fixed position layout is better with respect to the throughput, mean flow time per vehicle and the mean flow time per fleet. Furthermore, the fixed position layout is more robust than the flow line because performance measures are insensitive to the variations of factors.

A Study for Success Factors in On-line Games

  • Jung, Jai-Jin
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.12
    • /
    • pp.1657-1668
    • /
    • 2006
  • The last few years have represented a boom for the online gaming industry. Internet-based online games have been an increasingly popular form of entertainment. The gaming industry estimates there will be over 26 million online gaming participants in 2002. The rapid development of online game content and related information technology will increase the size of the industry and have a profound impact on many aspects of our lives and our society. This paper develops the exploratory LISREL model for identifying the factors affecting the players' loyalty to a specific brand of online game. The concepts of flow, word of mouth, feedback, challenge, social norms, and online community activities, etc, are all introduced into the model, as the independent variables directly and indirectly affecting loyalty. Based on data collected from an online survey, the validity of the model has been tested and interesting conclusions have been developed concerning the relationships between loyalty and flow, word of mouth, and other independent variables. It is hoped that this result might provide useful guidelines for developing successful online game content.

  • PDF

A Preliminary Study on the In-line Concentration Measurement of Absorbent Solution (흡수용액의 In-line 농도측정을 위한 기초연구)

  • 민병혁;황덕용;정시영;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • Titration method is one of the widely used methods for the concentration measurement of absorbent ammonia/water. However, this method is inconvenient because the solution should be extracted for the measurement. Moreover, significant error can be introduced by the evaporation of ammonia during the sampling and measuring procedure. In this study a reliable in-line concentration measurement method was proposed. To prove the validity of the concept, a measuring apparatus was designed, built, and tested with water. It is found that the location of flow inlet and exit is important in the measurement accuracy. The flow inlet and exit located in the middle of the test cell showed the best result. By the error analysis, it is expected that the ammonia concentration can be measured within the error of $\pm$0.18% assuming the error of 0.1 K in temperature measurement and 0.1 g in weight measurement.

A Study on the Gas-liquid Multiphase Flow Characteristics of the In-line Type Separator (In-line형 세퍼레이터의 기-액 다상유동 특성에 관한 연구)

  • Sang-Mok Han;Young-Ju Kim;Nam-Sub Woo;Wang-Do Lee;Hae-Jin Jo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.803-812
    • /
    • 2023
  • The subsea separator of an offshore plant for offshore oil and gas development performs the process of separating oil and gas from crude oil produced in the subsea. The oil-gas subsea separator can be divided into a gravity type that separates fluids by gravity and an in-line type that separates fluids using centrifugal force of density. In the case of the deep sea, the development of a small in-line type separator is required due to manufacturing cost and safety problems caused by water pressure. Therefore, in this study, the gas-liquid phase separation efficiency of the subsea separator was identified through the study of the multiphase flow characteristics of the in-line type separator. For the optimal design of the in-line type separator, the shape of the internal swirl element(ISE) was selected first, and the separation efficiency results for each section of the in-line type separator were analyzed. This study was conducted in parallel with experiments and numerical analysis, and it is expected that the reliability and efficiency of the in-line type separator will be improved through the results.

Effects of a Static Synchronous Series Compensator (SSSC) Based on a Soft Switching 48-Pulse PWM Inverter on the Power Demand from the Grid

  • Ustun, Taha Selim;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2010
  • In this paper the effects of a Static Synchronous Series Compensator, which is constructed with a 48-pulse inverter, on the power demand from the grid are studied. Extensive simulation studies were carried out in the MATLAB simulation environment to observe the compensation achieved by the SSSC and its effects on the line voltage, line current, phase angle and real/reactive power. The designed device is simulated in a power system which is comprised of a three phase power source, a transmission line, line inductance and load. The system parameters such as line voltage, line current, reactive power Q and real power P transmissions are observed both when the SSSC is connected to and disconnected from the power system. The motivation for modeling a SSSC from a multi-pulse inverter is to enhance the voltage waveform of the device and this is observed in the total harmonic distortion (THD) analysis performed at the end of the paper. According to the results, the power flow and phase angle can be controlled successfully by the new device through voltage injection. Finally a THD analysis is performed to see the harmonics content. The effect on the quality of the line voltage and current is acceptable according to international standards.

A Study on the Line Overload Alleviation Using Unified Power Flow Controller (UPFC를 이용한 선로 과부하 해소에 관한 연구)

  • Kang, In-Su;Lee, In-Yong;Park, Kyu-Hong;Chung, Jae-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1023-1025
    • /
    • 1999
  • This paper provides the steady-state UPFC model referred as UPFC injection model for power flow control. The application of UPFC for the line overload alleviation is demonstrated through a numerical example. It is shown that UPFC has the capability of regulating the power flow, therefore alleviating the line overload.

  • PDF

Numerical Study on Transient Aerodynamics of Moving Flap Using Conservative Chimera Grid Method (보존적 중첩격자기법을 이용한 동적 플랩의 천이적 공력거동에 관한 수치적 연구)

  • Choi S. W.;Chang K. S.;Kim I. S.
    • Journal of computational fluids engineering
    • /
    • v.5 no.2
    • /
    • pp.9-19
    • /
    • 2000
  • Transient aerodynamic response of an airfoil to a moving plane-flap is numerically investigated using the two-dimensional Euler equations with conservative Chimera grid method. A body moving relative to a stationary grid is treated by an overset grid bounded by a 'Dynamic Domain Dividing Line' which has an advantage for constructing a well-defined hole-cutting boundary. A conservative Chimera grid method with the dynamic domain-dividing line technique is applied and validated by solving the flowfield around a circular cylinder moving supersonic speed. The unsteady and transient characteristics of the flow solver are also examined by computations of an oscillating airfoil and a ramp pitching airfoil respectively. The transient aerodynamic behavior of an airfoil with a moving plane-flap is analyzed for various flow conditions such as deflecting rate of flap and free stream Mach number.

  • PDF

Total Transfer Capability Based on Optimal Power Flow (최적조류계산을 기초로한 총송전용량 결정)

  • Kim, Kyu-Ho;Song, Kyung-Bin;Rhee, Sang-Bong;Lee, Sang-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.570-571
    • /
    • 2008
  • This paper presents a method for the determination of total transfer capability in interconnected power systems, which is based on sequential quadratic programming (SQP). The objective function is the maximization of the interconnected line flow. To calculate TTC the control variables are the active power of the generating units, the voltage magnitude of the generator, transformer tap settings and SVC setting. The state variables are the bus voltage magnitude, the reactive power of the generating unit, line flows and the tie line flow. The method proposed is applied to the modified IEEE 14 buses model system.

  • PDF