• Title/Summary/Keyword: Flow front

Search Result 888, Processing Time 0.029 seconds

Numerical computation of pulsed laser ablation phenomena by thermal mechanisms (열적 메커니즘에 의한 펄스레이저 어블레이션 현상의 수치계산)

  • Oh, Bu-Kuk;Kim, Dong-Sik
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1572-1577
    • /
    • 2003
  • High-power pulsed laser ablation under atmospheric pressure is studied utilizing numerical and experimental methods with emphasis on recondensation ratio, and the dynamics of the laser induced vapor flow. In the numerical calculation, the temperature pressure, density and vaporization flux on a solid substrate are first obtained by a heat-transfer computation code based on the enthalpy method, and then the plume dynamics is calculated by using a commercial CFD package. To confirm the computation results, the probe beam deflection technique was utilized for measuring the propagation of a laser induced shock wave. Discontinuities of properties and velocity over the Knudsen layer were investigated. Related with the analysis of the jump condition, the effect of the recondesation ratio on the plume dynamics was examined by comparing the pressure, density, and mass fraction of ablated aluminum vapor. To consider the effect of mass transfer between the ablation plume and air, unlike the most previous investigations, the equation of species conservation is simultaneously solved with the Euler equations. Therefore the numerical model computes not only the propagation of the shock front but also the distribution of the aluminum vapor. To our knowledge, this is the first work that employed a commercial CFD code in the calculation of pulsed ablation phenomena.

  • PDF

Measurements on a Ship's Sloshing Flows by PIV (PIV에 의한 선박 슬로싱 유동 측정해석)

  • Doh, Deog-Hee;Cho, Yong-Beom;Pyeon, Yong-Beom;Baek, Tae-Sil;Kwon, Soon-Hong;Lee, Jeong-Han;Hwang, Yoon-Sik;Ryu, Min-Cheol
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.119-122
    • /
    • 2007
  • The sloshing flows in the cargo tank model of a ship are measured by PIV and are analyzed with the results. The measurement system is consisted of a Nd-Yag laser(120mJ, 15Hz). two cameras($1k\;{\times}\;1k$) and a host computer. Four experimental cases were tested for the tank model. in which swaying motions are made by 6 DOF-motion platform. The amplitudes of swaying are 9.76mm and 29.29mm, and the frequencies are 0.633Hz and 0.828Hz. The measurement regions are the vertical plane 50mm away from the front wall of the tank where a pump tower is installed. It was verified that the flow patterns of the sloshing are similar each other when the swaying amplitudes are similar.

  • PDF

A Study on the Effect of Turbulent Combustion upon Soot Formation in Premixed Constant-Volume Propane Flames (정적 예혼합 프로판 화염의 매연생성에 미치는 난류연소 영향에 관한 연구)

  • 배명환;안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.889-898
    • /
    • 2003
  • The soot yield is studied by a premixed propane-oxygen-inert gas combustion in a specially designed disk-type constant-volume combustion chamber to investigate the effect of turbulence on soot formation. Premixtures are simultaneously ignited by eight spark plugs located on the circumference of chamber at 45 degree intervals in order to observe the soot formation under high pressures and high temperatures. The eight flames converged compress the end gases to a high pressure. The laser schlieren and direct flame photographs for observation field with 10 mm in diameter are taken to examine into the behaviors of flame front and gas flow in laminar and turbulent combustion. The soot volume fraction in the chamber center during the final stage of combustion at the highest pressure is measured by the in situ laser extinction technique and simultaneously the corresponding burnt gas temperature by the two-color pyrometry method. It is found that the soot yield of turbulent combustion decreases in comparison with that of laminar combustion because the burnt gas temperature increases with the drop of heat loss.

Study of Shock Tube for Wave Phenomenon in High Speed Railway Tunnel(II)-attenuation and Nonlinear Effect of Compression Waves- (고속철도 터널에서 발생하는 파동현상에 관한 충격파관의 연구(2)-압축파의 감쇠와 비선형효과-)

  • ;;Matsuo, Kazuyasu
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1972-1981
    • /
    • 1995
  • As a railway train enters a tunnel at high speed, a compression wave is formed in front of the train and propagates along the tunnel. The compression wave subsequently emerges from the exit of the tunnel, which causes an impulsive noise. The impulsive noise is closely related to the pressure gradient of the compression wave propagating the tunnel. In order to investigate the characteristics of the compression waves, in the present study an experiment was made using a shock tube. The results show that the strength of a compression wave decreases with the distance from the tunnel entrance and the nonlinear effect of compression wave appears to be significant if strength of the initial compression wave is greater than 7 kPa. Furthermore if the wave pattern is known, attenuation of the compression wave propagating in a tunnel can be reasonably predicted by a theoretical equation considering viscous action and heat transfer in boundary layer.

A Study on the Geotechnical Characteristics of Tunnel Collapse (국내외 터널 붕락의 지반공학적 특징에 관한 연구)

  • Seo, Kyoungwon;Kim, Woongku;Baek, Kihyun
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.4
    • /
    • pp.75-81
    • /
    • 2009
  • This paper presents the geotechnical characteristics of tunnel co \l apse based on the case studies. For domestic cases, most collapses are likely to happen along the weakest zone of shear strength due to the change of stresses induced by excavation specially when soft or weathered rock exist in front of a tunnel. In other words, the collapse of a tunnel occurs along the highly weathered fractured zone due to blasting and excavation. In Europe, collapses have been occurred by one joint group even though the ground is relatively fresh and for the rocks of which RQD is over 50%. In addition, the amount of ground water flow does not seem to be seriously affected by the RQD range.

  • PDF

Modeling of Passive Heating for Replicating Sub-micron Patterns in Optical Disk Substrates (단열층을 이용한 광디스크 기판의 서브 미크론 성형에 대한 수치 해석)

  • 배재철;김영민;김홍민;강신일
    • Transactions of Materials Processing
    • /
    • v.13 no.1
    • /
    • pp.39-44
    • /
    • 2004
  • Transcribability of pit or land groove structures in replicating an optical disk substrate greatly affects the performance of a high-density optical disk. However, a solidified layer, generated during the polymer filling, deteriorates transcribability because the solidified layer prevents the polymer melt from filling the sub-micro patterns. Therefore, the development of the solidified layer during filling stage of injection molding must be delayed. For this delay, passive heating by insulation layer has been used. In the present study, to examine the development of the solidified layer delayed by passive heating, the flow of polymer melt with passive heating was analyzed. Passive heating markedly delayed the development of the solidified layer, reduced the viscosity of the polymer melt, and increased the fluidity of the polymer melt in the vicinity of the stamper surface with the sub-micro patterns. As a result, we predict that passive heating can improve transcribability of an optical disk substrate. To verify our prediction, we fabricated an optical disk substrate by using passive heating of a mold and measured the transcribability of an optical disk substrate.

The Risk Assessment of Tunnel Fire Through Real Scale Fire Test (실물터널 화재실험을 통한 터널화재 위험도 평가)

  • 최준석;최병일;김명배;한용식;장용재;이유환;황낙순;김필영
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.71-76
    • /
    • 2002
  • The real scale tunnel fire tests are carried out for the first time in domestic range to assess the extent of risk in the tunnel fire. The tunnel dimension is 465 m in length, 9.2 m in width and 6.5 m in height. Gasoline pools with 0.25 MW∼2.5 MW size and a 1500CC passenger car are used as fire sources. Six jet fans are used to change the flow velocity inside the tunnel. Temperatures at total 86 points in the tunnel are measured to find the temperature distribution and smoke behavior in the real tunnel fire. In the experiment, it is examined that the important parameters to assess the extent of risk in tunnel fire such as back layering of smoke front, descending of smoke layer and the fire size of a real passenger car.

COMPUTATIONAL FLUID DYNAMICS OF THE LOW-SPEED LONGITUDINAL AERODYNAMIC CHARACTERISTICS FOR BWB TYPE UCAV CONFIGURATION (연속일체형 날개-동체 타입 UCAV 형상의 저속 종방향 공력특성에 대한 전산유동해석)

  • Park, S.H.;Chang, K.;Shim, H.J.;Sheen, D.J.;Park, S.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.48-54
    • /
    • 2016
  • In the present work, numerical simulations were conducted on the scaled model of the BWB type UCAV in the subsonic region using ANSYS FLUENT V15. The prediction method was validated through comparison with experimental results and the effect of the twisted wing was investigated. To consider the transitional flow phenomenon, ${\gamma}$ transition model based on SST model was adopted. The coefficients of lift, drag and pitching moment were compared with experimental results and the pressure distribution and streamlines were investigated. The twisted wing decreases the lift force but increases lift-to-drag ratio through delay of stall and leading edge vortex's movement to the front, also the non-linearity of the pitching moment is decreased.

A Study of Smoke Movement in Tunnel Fire with Natural Ventilation (자연 배기 터널에서의 연기 거동에 관한 연구)

  • Kim, Sung-Chan;Lee, Sung-Ryong;Kim, Choong-Ik;Ryou, Hong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.7
    • /
    • pp.976-982
    • /
    • 2002
  • In this study, smoke movement in tunnel fire with natural ventilation shaft has been investigated with various size of fire source. Gasoline pool fire with different size of diameter - 73mm, 100mm, 125mm and 154mm - was used to describe fire source. Experimental data is obtained with 1/20 model tunnel test and its results are compared with numerical results. The computation were carried out using FDS 1.0 which is a field model of fire-driven now. Temperature profiles between measured and predicted data are compared along ceiling and near the ventilation shaft. Both results are in good agreement with each other. In order to evaluating a safe egress time in tunnel fire, horizontal smoke front velocity was measured in model tunnel fire tests and those are compared with numerical results. According to the presence or absence of natural ventilation shaft, ventilation effect are estimated quantitatively. Finally, this paper shows that computational fluid dynamics(CFD) is applicable to predict fire-induced flow in tunnel.

Characteristics of Preheated Air Combustion in a Laminar Premixed Flame (층류 예혼합 화염의 예열공기 연소특성)

  • Lee, Jong-Ho;Lee, Seung-Young;Hahn, Jae-Won;Chang, Young-June;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.7
    • /
    • pp.1039-1046
    • /
    • 2002
  • Co-flow axisymmetric laminar premixed flame of methane was used to study the influence of air temperature and $N_2$ addition on the flame structure, temperature field and emission characteristics. OH 2-D images and temperatures along the centerline were measured experimentally by PLIF and CARS techniques respectively to observe the influences of dilution and thermal effects of $N_2$ in the gas mixture. Also, the concentration of NOx was measured at each condition by gas analyser to see the suppression effect of N2 addition on NOx emissions. It was found that OH concentrations distribute widely as air temperature goes higher, while the effect of $N_2$ addition is not significant. But $N_2$ addition highly contributes to the flame front and NOx emissions which was argued to be due to the reduction of flame temperature. In accordance with experimental study, numerical simulation using CHEMKlN code was carried out to compare the temperature results with those acquired by CARS measurement, and we could find that there is good agreement between those results.