• Title/Summary/Keyword: Flow front

Search Result 888, Processing Time 0.024 seconds

Thermal Flow Characteristics of Impinging Air Jet by Shape of Turbulence Promoter (난류촉진체 형상에 의한 충돌제트의 열유동 특성)

  • Kum, Sungmin;Jho, Shigie;Yu, Byeonghun;Lee, Seungro
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.187-193
    • /
    • 2012
  • In this study, it was experimentally investigated the effect of the clearances distance between the rod and the impinging plate on characteristics of the thermal flow. For the heat transfer enhancement of wall jet region, the right triangle and the square rods were arranged in front of the impinging plate with various clearance distances. As results, the heat transfer enhancement rate of potential core region at H/B=2 was higher than that of transition region at H/B=10. In this experiment range, the maximum heat transfer enhancement rate was about 46 % higher at the square rod with H/B=2 and C=1mm compared with the flat plate. The heat transfer enhancement rate of the right triangle rod was on average about 3 to 8 % higher than that of the square rod, regardless of the clearance.

Analyzing Flow Variation and Stratification of Paldang Reservoir Using High-frequency W ater Temperature Data (고빈도 수온 자료를 이용한 팔당호의 성층과 흐름 변화 분석)

  • Ryu, In-Gu;Lee, Bo-Mi;Cho, Yong-Chul;Choi, Hwang-Jeong;Shin, Dong-Seok;Kim, Sang-Hun;Yu, Soon-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.392-404
    • /
    • 2020
  • The focus of this study was to quantify the thermal stratification and analyze the relationship between the stratification structure and the tributaries to understand flow variations in the Paldang Reservoir. The vertical distribution of the temperature and density gradients, and the depth and thickness of the thermocline were quantitatively calculated using a lake physics tool (rLakeAnalyzer) and high-frequency monitoring data. Based on a density gradient of 0.2 kg/㎥/m, the thermocline was formed from mid-May to early-September 2019 and the other periods were weakly stratified or mixed. The thickness of the thermocline was developed until 4.7 m and the depth of the thermocline was formed at a depth of 3 - 6 m at the front of the Paldang Reservoir. During the formation of the thermocline, the Namhangang and Gyeongancheon tributaries with relatively high water temperature (low-density) flowed into the upper layer of the reservoir, and the Bukhangang tributary with low water temperature (high-density) mainly affected the lower layer of the reservoir. This is because the density currents were formed due to the difference in the water temperature of the tributaries. The findings of this study may be used for constructing high-frequency monitoring and quantitative data analyses of reservoirs.

A Study on the Effect of Trunk Stabilization Program on Body Balance, Lung Capacity, Muscular Activity of Healthy Adults (체간 안정화운동이 정상성인의 균형, 폐활량, 근활성도에 미치는 영향)

  • Nam, Hyoungchun;Jo, Yoonjin;Kang, Byeongjoo;Kim, Seulbi;An, Wookjoo;Lee, Hwajoo;Jeong, Sujin
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.3 no.4
    • /
    • pp.43-51
    • /
    • 2015
  • Purpose : This study examines the effect of trunk stabilization program on the body balance, lung capacity, and muscular activity of the rectus abdominis and external oblique of healthy adults. Method : A survey was conducted for 20 students of K University located in the city of Y in Gyeongsangbuk-do Province of Korea. The trunk stabilization program consisted of a hollowing exercise, curl-up, bridging exercise, and birddog exercise. This was performed 14 times in total (7 times a week for two weeks). For analysis, good balance was used to measure both static and dynamic balancing ability. A peak flow meter was used to measure the maximum expiratory flow, and MP150 was used to measure muscular activity of the rectus abdominis and external oblique. Result : After the trunk stabilization program, the participants showed a difference in score and time taken to achieve static and dynamic balance, and muscular activity of the rectus abdominis and external oblique at a statistically significant level (p<0.05). However, no significant difference was observed in the left-to-right distance and front-to-back distance in a dynamic balance, and the lung capacity (p>0.05). Conclusion : The results showed that the trunk stabilization program was effective in enhancing both static and dynamic balancing ability and muscular activity. It also increased the lung capacity although the change was not at a statistically significant level.

A Study on Fire Hazard Analysis and Smoke Flowing for the Semiconductor Manufacturing Process (반도체 제조공정의 연기유동에 관한 연구)

  • Han, Soo-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.197-211
    • /
    • 2007
  • The power of semiconductor, Korea is continuously constructing semiconductor production line for keeping a front-runner status. however, studies and data about potential risks in semiconductor factory are still short. If fire does not initially suppressed, the fire causes a great damage. To decrease fire risk factors, in addition to fire fighting safety equipment, more important thing is how to design and construct fire protection system. The current fire protection codes about semiconductor factory come under functional law, and this law is short of consideration about particularity of factory. The existing prescriptive fire codes depending on experience compose without evident engineering verifications, thus equipments which is created by the current prescriptive fire code may bring about a variety of problems. For example, the design under the current regulation can not cope with the excessive investments, low efficiencies, and the diversifying construction designs and be applied to the quick changes of new technologies. Ergo, an optimal design for fire protection is to equip fire protection arrangements with condition and environment of production field. Manufacturing factory of semiconductors is a windowless airtight space. And for cleanliness, there exists strong flow of cooperation. Therefore, there is a need for fire safety design that meets the characteristic of a clean room. Accordingly, we are to derive smoke flow according to cooperation process within a clean room and construction plan of an optimal sensor system. In this study, in order to confirm the performance of proposed smoke-exhaust equipment and suggest efficient smoke exhaust device when there is a fire of 1MW of methane in the clean room of company H, we have implemented fire simulation using fluid dynamics computation.

A Study on the Air Flow Characteristics in an Apartment Complex and Ventilation Performance of an Individual Unit for Improving IAQ (주동형태 변화에 따른 아파트 단지내 기류분석 및 단위주호의 환기성능에 관한 연구)

  • Lee, Jung-Hyun;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.11-16
    • /
    • 2005
  • The recent trends of high-density and high-rise in apartment housing have caused the problems of decrease in ventilation rates and increase of indoor pollutant contaminants. SHS(Sick House Syndrome) has now become a major issue and threats the health of residents. To solve these indoor air problems, increase in ventilation rate is considered as one of the most efficient approach. Thus, the recent housing development is pursuing improvement in the site design and the layout of apartment building blocks to promote natural ventilation is now investigated as one of the fundamental solutions. This study was focused on the air flow characteristics of outdoor environment in an apartment complex to keep the pollutants out of the site. Age of air and pressure difference have been used as indices of the outdoor air quality. Four different types of apartment building layouts have been analyzed by CFD simulation. This study again selected a real apartment housing complex as a case study model. By analyzing the pressure differences between the front and rear of an apartment building block, the ventilation performance in each individual unit was evaluated, and its impact on ventilation performance is investigated by analyzing the stagnant air around the apartment building blocks. During this process, existing patterns of apartment housing layout have been evaluated, and the most appropriate site layout has been chosen to analyze the outdoor airflow patterns. Based on the analysis of airflow patterns of site layout, the possibilities of improving ventilation performance of an individual apartment housing is proposed.

Measurement of Aerodynamic Heating over a Protuberance in Hypersonic Flow of Mach 7 (Mach 7 극초음속 유동 내의 돌출물 공력가열 계측)

  • Lee, Hyoung-Jin;Lee, Bok-Jik;Jeung, In-Seuck;Kim, Seong-Lyong;Kim, In-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.6
    • /
    • pp.562-570
    • /
    • 2009
  • An Experimental study was conducted on the flow characteristics and interference heating caused by a two-dimensional object protruding from a flat plate using a blow-down type of hypersonic wind tunnel. Inflow condition was a free-stream Mach number of 7.0 and a unit Reynolds number of $2.0{\times}10^6/m$. Experimental conditions were varied with three heights of protuberance for two flat plate models which have different lengths. Experimental data were obtained from Schlieren visualization images and heat flux measurements. Also, this paper suggests hypersonic experimental techniques such as boundary-layer detection method in detail. A Large separation region was observed in front of the protuberance and that region was very sensitive to the height of protuberance and the length of the flat plate. For only the highest protuberance, a severe jump of heat flux was observed at the top station among the measuring points. Measured heat flux is large when the height of protuberance is large and the length of flat plate is long.

An Experimental Study on Freezing Behavior of NaCl and Heavy Metal Aqueous Solution Using Freeze Concentration Method (동결농축법을 이용한 염수 및 중금속 수용액의 동결거동에 관한 실험 연구)

  • Kim, Jung-Sik;Lim, Seung-Taek;Oh, Cheol
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.129-135
    • /
    • 2013
  • Recently, waste water treatment system is developed in small and middle size to get more economic advantage. Freeze concentration system has high thermodynamic efficiency and low energy consumption, can re-use purified water and cold energy obtained from ice. This study was experimentally performed to investigate pollution containment in frozen layer by cooling wall temperature, air-bubble flow methods, initial ice-lining thickness of frozen layer in NaCl aqueous solution and the representative heavy metals, Pb and Cr aqueous solution. As the result, a decrease in the cooling wall temperature bring a higher growth rate of ice front and the more solute was involved in frozen layer. The method to inject directly air-bubble into ice-liquid interface through ring shape nozzle gave high purity of ice compared to indirect method. Ice lining in 5mm thickness resulted in frozen layer with higher purity than 1mm thickness.

Influence of Dam Water Discharge on the Oceanography and Fishery (해황과 어황에 미치는 댐 방수의 방향)

  • Chang Sun-duck
    • 한국해양학회지
    • /
    • v.1
    • /
    • pp.49-55
    • /
    • 1971
  • After the heavy precipitation from April 1969 to September 1970, more than 1.359 10$\^$6/㎥ of fresh water was discharged through diversion channel of the Namgang Dam. The sands and muds in the northern Sachon Bay were moved and swept away by the strong southsard flow which was observed to be speedier than five knots. The shellfish culture facility as well as the oysters and bivalves were buried. In Sachon Bay, a southward surface ebb current of approximately one knot stratifies above the northward flow of approximately 0.5 knot, which seems to be similar to the salt wedge estuary. The stratified current is responsible for the breaking of the gill nets and other fishing gears. The salinity of sea water in Chinju Bay decreased remarkably and the abnormal low salinity water lower than 5 was distributed in Sachon Bay. The low salinity water front was observed in eastern Chinju Bay and the Samchonpo Channel, where the salinity was increased from 4.6 to approximately 30 within half a tidal cycle. These caused the oysters and bivalves die, and drove anchovies and octopus out to the sea and prevented them from approaching the bay. The decrease of salinity causes the decrease of density and osmotic pressure of sea water. Turbid water would prevent the sunlight from penetrate into deep layer.

  • PDF

Self-Burial Structure of the Pipeline with a Spoiler on Seabed (해저지반에 설치된 스포일러 부착형 파이프라인의 자가매설 기능분석)

  • Lee, Woo-Dong;Hur, Dong-Soo;Kim, Han-Sol;Jo, Hyo-Jae
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.310-319
    • /
    • 2016
  • If a spoiler was attached to the pipeline investigated in a previous study, a strong flow and vortex at the lower part caused scouring and thus an asymmetric pressure distribution, which assisted in the analysis of the self-burial structure where a down force was applied to the pipe. However, only the fluid-pipe interaction was considered, excluding the medium (seabed), when practically burying the pipeline. Thus, this study applied a numerical model (LES-WASS-2D) to directly analyze the non-linear interactions among the fluid, pipe, and seabed in order to perform numerical simulations of a pipeline with a spoiler installed on the seabed. This allowed the self-burial mechanism of a pipeline with a spoiler to be analyzed in the same context as the previous study that considered only the fluid-pipe interaction. However, when a pipeline was installed on the seabed, a strong flow and vortex were found at the front of the bottom, and a spoiler accelerated the fluid resistances. This hydraulic phenomenon will reinforce the scouring and down force on the pipeline. In the general consideration of the numerical analysis results by the specifications and arrangements of the spoiler, a pipeline with a spoiler was found to be the most effective for the self-burial function.

A Study on the Al2O3 Thin Film According to ALD Argon Purge Flow Rate and Application to the Encapsulation of OLED (ALD 아르곤 퍼지유량에 따른 Al2O3박막 분석 및 유기발광 다이오드 봉지막 적용에 관한 연구)

  • DongWoon Lee;Ki Rak Kim;Eou Sik Cho;Yong-min Jeon;Sang Jik Kwon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2023
  • Organic light-emitting diode(OLED) is very thin organic films which are hundreds of nanometers. Unlike bottom-emission OLED(BEOLED), top-emission OLED(TEOLED) emits light out the front, opaque moisture absorbents or metal foils can't be used to prevent moisture and oxygen. And it is difficult to have flexible characteristics with glass encapsulation, so thin film encapsulation which can compensate for those two disadvantages is mainly used. In this study, Al2O3 thin films by atomic layer deposition(ALD) were examined by changing the argon gas purge flow rate and we applied this Al2O3 thin films to the encapsulation of TEOLED. Ag / ITO / N,N'-Di-[(1-naphthyl)-N,N'-diphenyl]-1,1'-biphenyl-4,4'-diamine / tris-(8-hydroxyquinoline) aluminum/ LiF / Mg:Ag (1:9) were used to fabricate OLED device. The characteristics such as brightness, current density, and power efficiency are compared. And it was confirmed that with a thickness of 40 nm Al2O3 thin film encapsulation process did not affect OLED properties. And it was enough to maintain a proper OLED operation for about 9 hours.

  • PDF