• Title/Summary/Keyword: Flow failure

Search Result 882, Processing Time 0.021 seconds

Performance of the Exhaust Filtration System of Hot Cell at PIEF (조사후시험시설에서의 핫셀 배기포집시스템의 성능평가)

  • Hwang, Yong-Hwa
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.799-804
    • /
    • 2011
  • Radioactivity of high concentrations have existed in the handling nuclear materials in hot cell of PIEF(Post Irradiation Examination Facility). The exhaust filtration system was enabled to process cylindrical filters by using a manipulator in the hot cell. By establishing a double filtration system with two filters, backup protection against leakage or failure of the first is provided by the second filter. Additionally, this a arrangement is arrange intended to increase the total filtration efficiency. The result of the pressure drop changing in the air flow of the cylindrical and HEPA filters is observed by a curved line. A filtering efficiency of more than 99.99% to $0.3{\mu}m$ particle appears in the upstream and downstream during the efficiency test on the HEPA filters. The V-pleats type had a lower pressure drop than the separator type. There was no damage during usage and was found to be suitable with high capacity of air volume. Therefore, by carrying out performance tests of the exhaust filtration system, efficiency and safety can be achieved.

A Case of an EXIT procedure for Airway management of fetus with Agnathia (하악결손증 태아에서 기도확보를 위해 시행한 EXIT 시술 1례)

  • Bong Jeong Pyo;Kim Yoo Jung;Yang Jong Won;Kim Jin Hyung;Kim Tae Hwan;Choi Seong Jin
    • Korean Journal of Bronchoesophagology
    • /
    • v.11 no.1
    • /
    • pp.32-36
    • /
    • 2005
  • This study aimed to report a case of infant who presented with a prenatal ultrasound diagnosis of agnathia, polyhydramnios followed by a review of previous studies. As widely acknowledge, agnathia is a complex lethal malformation characterized by absent mandible, microstomia, microglossia and ear anomaly which are secondary results to a defect of the first branchial auh. Newborn infants with agnathia often suffer from airway obstruction, causing fatal respiratory failure. The most difficult part of treating those newborns is to keep the airway patent. Therefore, as early airway management planning as possible is the most important part. Airway management was achieved with tracheotomy through an ex utero intrapartum treatment procedure(EXIT). The case of this infant, reporting here, was underwent tracheotomy with preservation of uteroplacental blood flow and gas exchange.

  • PDF

ShakingTest of Waterfront Structure for Liquefaction Counter measure (항만구조물의 액상화 대책을 위한 진동대 실험에 대한 연구)

  • 박종관
    • Geotechnical Engineering
    • /
    • v.8 no.3
    • /
    • pp.37-50
    • /
    • 1992
  • Liquefaction leads to severe damage to earth structures after an earthquake. In this study, shaking table tests were performed on model waterfront structures as a countermeasure against liquefaction. The waterfront structure was reinforced by a compacted Bone, which was investigated for its effectiveness in protecting the structure from excessive deformation induced by the lateral pressure of liquefied ground. Through the tests . on embankment, double sheet pile wall, and anchor sheet pile wall, good quantitative information on the behavior of flow failure and the extent of reinforcement was obtained. The extent of a compacted zone for the protection of the structure depends on the magnitude of the acceleration during the shaking. The measured deformation was represented in terms of the extent of the compacted zone and the magnitude of the input acceleration.

  • PDF

Quantitative Evaluation of Appointment System for Outpatients in Dental Clinic (치과의원 외래환자 예약관리체계의 계량적 평가)

  • Lee, Hyung-Ju;Chang, Hye-Jung
    • Korea Journal of Hospital Management
    • /
    • v.8 no.2
    • /
    • pp.49-69
    • /
    • 2003
  • This study purported to evaluate the performance of the appointment system for outpatients in primary care dental clinic. The data of patients' time flow for 1,245 patients in Y Dental Clinic were collected for one month in 2002 and then analyzed. Specifically, the time periods of treatment and patients' waiting as well as rates of appointment and it's failure are estimated. The accuracy of expected treatment time period was also evaluated. The results showed that 72% of patients visited the clinic with appointments, and only 56% kept their appointments. The patient's waiting time period turned out to be 11 minutes in Y clinic. The expected treatment time period is turned out to be very important because they influence significantly on patient's waiting time period. Practically, the expected treatment time period should be overestimated about 9 minutes in general, and the characteristics of dentist, each patient's diagnosis and age need to be especially considered. Hospitals and clinics also need to make the systematic and detailed critical pathways for a variety of patient cases by analyzing the patients' treatment pattern. With the improved appointment systems, healthcare institutions will approach the goal of effective and efficient management of the institution and also satisfy their customers.

  • PDF

Investigation of ratio of TBM disc spacing to penetration depth in rocks with different tensile strengths using PFC2D

  • Sarfarazi, Vahab;Haeri, Hadi;Shemirani, Alireza Bagher;Hedayat, Ahmadreza;Hosseini, Seyed Shahin
    • Computers and Concrete
    • /
    • v.20 no.4
    • /
    • pp.429-437
    • /
    • 2017
  • In this study, the effect of the tensile strength and ratio of disc spacing to penetration depth on the efficiency of tunnel boring machine (TBM) is investigated using Particle flow code (PFC) in two dimensions. Models with dimensions of $150{\times}70mm$ made of rocks with four different tensile strength values of 5 MPa, 10 MPa, 15 MPa and 20 MPa were separately analyzed and two "U" shape cutters with width of 10 mm were penetrated into the rock model by velocity rate of 0.1 mm/s. The spacing between cutters was also varied in this study. Failure patterns for 5 different penetration depths of 3 mm, 4 mm, 5 mm, 6 mm, and 7 mm were registered. Totally 100 indentation test were performed to study the optimal tool-rock interaction. An equation relating mechanical rock properties with geometric characteristics for the optimal TBM performance is proposed. The results of numerical simulations show that the effective rock-cutting condition corresponding to the minimum specific energy can be estimated by an optimized disc spacing to penetration depth, which, in fact, is found to be proportional to the rock's tensile strength.

Implementing a Dielectric Recovery Strength Measuring System for Molded Case Circuit Breakers

  • Cho, Young-Maan;Rhee, Jae-ho;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1752-1758
    • /
    • 2018
  • In a low-voltage distribution system, the molded case circuit breaker (MCCB) is a widely used device to protect loads by interrupting over-current; however the hot gas generated from the arc discharge in the interrupting process depletes the dielectric recovery strength between electrodes and leads to re-ignition after current-zero. Even though the circuit breaker is ordinarily tripped and successfully interrupts the over-current, the re-ignition causes the over-current to flow to the load again, which carries over the failure interruption. Therefore, it is necessary to understand the dielectric recovery process and the dielectric recovery voltage of the MCCB. To determine these characteristics, a measuring system comprised of the experimental circuit and source is implemented to apply controllable recovery voltage and over-current. By changing the controllable recovery voltage, in this work, re-ignition is driven repeatedly to obtain the dielectric recovery voltage V-t curve, which is used to analyze the dielectric recovery strength of the MCCB. A measuring system and an evaluation technique for the dielectric recovery strength of the MCCB are described. By using this system and method, the measurement to find out the dielectric recovery characteristics after current-zero for ready-made products is done and it is confirmed that which internal structure of the MCCB affects the dielectric recovery characteristics.

BGP Session Takeover Method Based on Docker (Docker 기반의 BGP 세션 절체 방안)

  • Kim, Sang-il;Kim, Hwa-sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.2
    • /
    • pp.238-240
    • /
    • 2016
  • Recently, the improvement in the data communication networks in terms of availability and reliability is emerging as a critical issue. In this context, the high availability and reliability of routers that control data flow and routing path between networks on the data communication network are being recognized as critical problems. Many methods for providing high availability to minimize the loss cost caused by the failure of a router are being studied. This paper proposed a BGP session takeover method using the Docker to support the high availability of the BGP session and to improve the takeover performance.

Leakage Current Energy Harvesting Application in a Photovoltaic (PV) Panel Transformerless Inverter System

  • Khan, Md. Noman Habib;Khan, Sheroz
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.4
    • /
    • pp.190-194
    • /
    • 2017
  • Present-day solar panels incorporate inverters as their core components. Switching devices driven by specialized power controllers are operated in a transformerless inverter topology. However, some challenges associated with this configuration include the absence of isolation, causing leakage currents to flow through various components toward ground. This inevitably causes power losses, often being also the primary reason for the power inverters' analog equipment failure. In this paper, various aspects of the leakage currents are studied using different circuit analysis methods. The primary objective is to convert the leakage current energy into a usable DC voltage source. The research is focused on harvesting the leakage currents for producing circa 1.1 V, derived from recently developed rectifier circuits, and driving a $200{\Omega}$ load with a power in the milliwatt range. Even though the output voltage level is low, the harvested power could be used for charging small batteries or capacitors, even driving light loads.

A study of synthesis method Lean DFSS and Advanced Product Quality Planning of ISO/TS16949 (ISO/TS16949 APQP 프로세스와 Lean DFSS 프로세스의 통합에 관한 연구)

  • Kwon, Sok;Lee, Kang-Koon;Ree, Sang-Bok
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2006.04a
    • /
    • pp.456-460
    • /
    • 2006
  • 많은 6시그마 혁신을 하는 기업 중에서 ISO9000 시리즈나 ISO/TS16949 인증을 받고 있다. 그럼에도 불구하고 6시그마 도입 초기부터 ISO/TS16949와 통합운영을 생각하고 추진하는 곳은 많지 않다. ISO/TS16949에서는 기업전반의 프로세스에 많은 중점을 두고 있다. 그 중에서도 APQP(Advanced Product Quality Planning)은 제품 초기에서부터 명확한 품질계획 업무 프로세스를 가지고 활동을 하라는 필수 프로세스를 요구하고 있다. 그러나 구체적인 Flow나 단계는 각 기업체의 특성에 맞기고 있다. 6시그마의 Lean DFSS는 이러한 제품개발 프로세스의 구체적인 전계단계를 제공하고 있다 여기에 APQP에서 요건으로 명시한 각 프로세스 단계마다 Input요소, Output요소, Target, 그 프로세스를 책임질 구성원, 핵심성공요인, 핵심성공지수, 단계마다의 FMEA(Failure Mode Effect Analysis) 분석을 대응하면 도입 초기에서부터 상호 유기적이면서 효과적인 System이 된다.

  • PDF

An Experimental Study on the Collapse Phase of a River Leeve(I) -Effects of the Geometric Characteristics of Cross Section (하천제방 붕괴 양상의 실험적 연구(I) - 단면의 기하학적 특성치의 영향)

  • Lee, Sang-Tae;Lee, Jong-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.2
    • /
    • pp.141-154
    • /
    • 2001
  • An experimental study was performed to investigate the effects of levee crest width and the slope steepness on levee break due to overtopping flow. The phenomenon of bank failure can be described in 4 stages. In this study, the magnitudes of breach width, breach depth peak discharge, and scouring shape at the break site were measured, and the result shows that peak discharge will be reduced and breach duration extended by widening the crown width and lessening the levee slope steepness. The breach width was narrower and the breach depth deeper, as the levee crest width become wider or the slope steeper. And, the bed scour depth was deeper and steeper, as the levee crest crest width become narrower or the slope milder.

  • PDF