• Title/Summary/Keyword: Flow configuration

Search Result 1,146, Processing Time 0.03 seconds

A Preliminary Configuration Design of Methane/Oxygen Bipropellant Small-Rocket-Engine through Theoretical Performance Analysis (이론성능해석에 의한 메탄/산소 이원추진제 소형로켓엔진의 예비형상설계)

  • Bae, Seong Hun;Jung, Hun;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.3
    • /
    • pp.47-53
    • /
    • 2015
  • Design parameters required for Methane/oxygen bipropellant small-rocket-engine were derived through a theoretical performance analysis. The theoretical performance of the rocket engine was analyzed by using CEA and optimal propellant mixture ratio, characteristic length, and optimal expansion ratio were calculated by assuming chemical equilibrium. A coaxial-type swirl injector was chosen because of its outstanding atomization performance and high combustion efficiency compared to other types of injector and also a bell nozzle with 80% of its full length was designed. The rocket engine configuration with 1.72 MPa of chamber pressure, 0.18 kg/s in total propellant mass flow, and O/F ratio of 2.7 was proposed as a ground-firing test model.

Impingement heat transfer within 1 row of circular water jets : Part 1-Effects of nozzle configuration (1열 원형 충돌수분류군에 의한 열전달의 실험적 연구 (제1보, 노즐형상의 영향))

  • 엄기찬;김상필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.50-58
    • /
    • 2000
  • Experiments were carried out to obtain the effects of nozzle configuration and jet to jet spacing on the heat transfer characteristics of single line of circular water jets impinging on a constant heat flux plane surface. The nozzle configurations are Cone type, Reverse cone type and Vertical circular type, and the nozzle arrays are single jet(nozzle dia. 8 mm), 1 row of 3 jets and 1 row of 5 jets. Jet velocities ranging from 3m/s to 8m/s were investigated for the nozzle to target plate spacing of 80 mm. For the Cone and Reverse cone type nozzle arrays, the average Nusselt number of 1 row of 5 jets was larger than that of 1 row of 3 jets at Re$_{D}$<45000, but that of 1 row of 3 jets was larger than that of 1 row of 5 jets at $Reo\le45000$. For the Vertical circular type nozzle, however, the average Nusselt number of 1 row of 3 jets was larger than that of 1 row of 5 jets at all jet velocities. In the condition of fixed mass flow rates, the maximum heat transfer augmentation was obtained for 1 row of 5 jets and was over 2 times larger than that of the single jet for all nozzle configurations. The nozzle configurations that produce the maximum average Nusselt number are as follows: For 1 row of 3 jets, the Vertical circular type at $Reo\le45000$ and the Reverse cone type at $Reo\le45000$. But, they are the Reverse cone type at Re$_{D}$<55000 and the Vertical circular type at$Reo\le55000$ for 1 row of 5 jets.

  • PDF

Impingement heat transfer within 1 row of circular water jets: Part 2-Effects of nozzle to heated surface distance (1열 원형 충돌수분류군에 의한 열전달의 실험적 연구 (제2보, 노즐-전열면간 거리의 영향))

  • 엄기찬;이종수;김상필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.59-66
    • /
    • 2000
  • In a previous paper, we have examined the effects of nozzle configuration and jet to jet spacing on the heat transfer of 1 row of circular water jets. In this paper, experiments have been conducted to obtain the effects of nozzle to target plate distances on the heat transfer of 1 row of 3 jets and 1 row of 5 jets. The nozzle configurations are Cone type, Reverse cone type and Vertical circular type. Nozzle to target plate distance H was varied from 16 mm(H/D=2) to 80mm(H/D=10). For fixed value of mass flow rate and nozzle to target plate distance, larger values of average Nusselt number were obtained for the smaller jet to jet spacing. For the array of water jets, the average heat transfer was decreased slightly with increasing nozzle to target plate distance at low jet velocity of $\textrm{V}_{o}$=3 m/s. However, except for $\textrm{V}_{o}$=8 m/s of 1 row of 5 jets, it was increased with increasing nozzle to target plate distance at high jet velocity of $\textrm{V}_{o}$$\geq$6m/s. We proposed to apply the nozzle configuration of maximum average heat transfer to each nozzle to target plate distance for 1 row of 3 jets, and, it was Reverse cone type nozzle for 1 row of 5 jets(Reynolds number$\geq$36000).

  • PDF

Macroscopic Visualization of Diesel Sprays with respect to Nozzle Hole Numbers and Injection Angles (분공수와 분사각의 영향에 따른 거시적 디젤 분무 가시화)

  • Yongjin Jung;Jinyoung Jang;Choongsik Bae
    • Journal of ILASS-Korea
    • /
    • v.29 no.1
    • /
    • pp.32-37
    • /
    • 2024
  • Macroscopic visualization of non-evaporating sprays was experimentally conducted to investigate spray tip penetration and spray angle under low-density conditions, corresponding to an early injection strategy. Furthermore, injectors with varying injection angles (146° and 70°) and numbers of holes (8 and 14) were employed to examine the impact of injector configuration. Compared to the baseline injector, 8H146, which has 8 holes and a 146° injection angle, the spray tip penetration of the 8H70 injector was found to be longer. This can be attributed to higher momentum due to a smooth flow field between the sac volume and the nozzle inlet, which is located closer to the injector tip centerline. The increase in velocity led to intense turbulence generation, resulting in a wider spray angle. Conversely, the spray tip penetration of the 14H70 injector was shorter than that of the 8H70 injector. The competition between increased velocity and decreased nozzle diameter influenced the spray tip penetration for the 14H70 injector; the increase in momentum, previously observed for the 8H70 injector, contributed to an increase in spray tip penetration, but a decrease in nozzle diameter could lead to a reduction in spray tip penetration. The spray angle for the 14H70 injector was similar to that of the 8H146 injector. Moreover, injection rate measurements revealed that the slope for a narrow injection angle (70°) was steeper than that for a wider injection angle during the injection event.

Effect of Gas now Modulation on Etch Depth Uniformity for Plasma Etching of 150 mm GaAs Wafers (150 mm GaAs 웨이퍼의 플라즈마 식각에서 식각 깊이의 균일도에 대한 가스 흐름의 최적화 연구)

  • 정필구;임완태;조관식;전민현;임재영;이제원;조국산
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.2
    • /
    • pp.113-118
    • /
    • 2002
  • We developed engineering methods to control gas flow in a plasma reactor in order to achieve good etch depth uniformity for large area GaAs etching. Finite difference numerical method was found quite useful for simulation of gas flow distribution in the reactor for dry etching of GaAs. The experimental results in $BCl_3/N_2/SF_6/He$ ICP plasmas confirmed that the simulated data fitted very well with real data. It is noticed that a focus ring could help improve both gas flow and etch uniformity for 150 mm diameter GaAs plasma etch processing. The simulation results showed that optimization of clamp configuration could decrease gas flow uniformity as low as $\pm$ 1.5% on an 100 mm(4 inch) GaAs wafer and $\pm$ 3% for a 150 m(6 inch) wafer with the fixed reactor and electrode, respectively. Comparison between simulated gas flow uniformity and real etch depth distribution data concluded that control of gas flow distribution in the chamber would be significantly important in order or achieve excellent dry etch uniformity of large area GaAs wafers.

Nitrogen Removal Characteristics in DynaFlow Biofilter System Using Sewage Wastewater of Low C/N Ratio (낮은 C/N비에서 운영되는 유로변경식 생물여과 공정의 질소 제거 특성)

  • Kim, Jin-Sik;Kim, Kyu-Ri;Kang, Han-Sol;Won, In-Seop;Kim, Keum-Yong;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.3
    • /
    • pp.189-194
    • /
    • 2012
  • In this study, a 3-stage biological aerated filter (BAF) system was proposed to enhance nitrogen removal in the treatment of low carbon to nitrogen ratio (C/N ratio) municipal wastewater. Laboratory experiments were conducted to evaluate the effects of dynamic-flow at the HRT of 6 h. Results of the long-term operation of 3-stage BAF systems showed that the dynamic-flow enabled the total nitrogen removal (T-N) removal efficiency of the system to be about 7 % higher than that of non-dynamic-flow system in treating domestic wastewater due to the more efficient use of organic substrates. The overall $NH_4$-N removal performance was stable during the operational period due to the unique system configuration where independent nitrification occurred. It was concluded that the 3-stage BAF system proposed in this study provided excellent performance in the removal of nitrogen by employing dynamic-flow and three columns functioning as sorption, denitrification and nitrification, respectively.

Evaluation of Woodchip and Synthetic Fiber as Biofilter Media for the Treatment of Livestock Stormwater (가축사육단지 강우유출수 처리목적 바이오 필터 여재로서 우드칩과 합성섬유의 평가)

  • Cheng, Jing;Guerra, Heidi B.;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.23 no.1
    • /
    • pp.94-105
    • /
    • 2021
  • Two vertical flow biofilters in series (BFS) employing synthetic fiber (FBF) followed by woodchip (WBF) was investigated in order to assess its potential as an alternative to the typical vertical-horizontal flow configuration in removing nonpoint source pollutants specifically nutrients and organics. These lab-scale column biofilters were operated for 176 days alongside three other columns that were added for control and sampling purposes. The biofilter columns were fed with either a semi-artificial piggery stormwater or artificial stormwater with specific ammonia and nitrate contents. Results reveal that the BFS was more effective than a single biofilter in removing pollutants especially nitrogen. FBF was found to remove up to 100% of ammonia from the stormwater with corresponding increase in nitrate in the outflow which shows evidence of active nitrification. Meanwhile, the succeeding vertical WBF was able to subsequently remove 77% of the nitrate. The effective reduction of nitrate in a vertical flow biofilter was believed to be due to the use of woodchip which can provide a carbon source that is required for denitrification. However, further investigation is needed to support this claim. Nonetheless, the study shows the potential of vertical flow BFS as a nitrogen removal mechanism especially in areas where enough land space for horizontal flow biofilters is limited.

Fundamental studies on thermosolutal convection in mercurous bromide(Hg2Br2) physical vapor transport processes (브로민화 수은(I)(Hg2Br2) 물리적 증착공정에서 온도농도대류의 기초연구)

  • Geug Tae Kim;Moo Hyun Kwon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.3
    • /
    • pp.110-115
    • /
    • 2023
  • During the Hg2Br2 physical vapor transport process, with increasing the partial pressure of component B, PB from 40 Torr to 200 Torr, a unicellular convective flow structures move from the crystal growth region to the center region in the vapor phase. The boundary layer flow is dominant for PB = 40 Torr, and the core region flow is dominant for PB = 200 Torr. The flow in the vapor phase shows a three-dimensional convective flow structure with a single cell (unicellular) for PB = 40 Torr and 200 Torr, exhibits an asymmetrical flow with respect to the x, y central axis under the horizontally oriented configuration with an aspect ratio (length-to-width) of 3 and linear conducting walls. The critical temperature difference between the source and crystal region is about 30 K. The total molar flux of Hg2Br2 increases with the temperature difference until the total molar flux reaches the critical value. At the critical total molar flux, the total molar flux abruptly decreases.

Comparative analysis of inundation flow patterns and flood risk assessment methods within subway stations (지하철 역사 내 침수 흐름 분석 및 침수 위험도 평가 방법 비교)

  • Shin, Jaehyun;Kim, Minjeong;Cho, Inhwan;Park, Inhwan
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.10
    • /
    • pp.667-678
    • /
    • 2023
  • In this study, quasi-3D inundation flow simulations were conducted for a simplified subway station configuration. The effects of variations in rainwater inflow locations and discharge were investigated, analyzing the resulting inundation flow patterns and flood risk. The inundation simulation results calculated the incipient velocities for slipping and toppling accidents to assess pedestrian safety. The results indicated that velocities exceeding the incipient velocity for slipping accidents mainly occurred on the flooded staircase. Meanwhile, velocities surpassing the incipient toppling accidents were observed around the staircase and the corridor near the staircase leading to B2F. This observation is consistent with the results from the specific force distribution analysis. To provide detailed flood risk assessments, the Flood Hazard Degree (FD) was applied with four levels of criteria, along with the Flood Intensity Factor (FIF). The results demonstrated that FD identified a broader area at risk of flood-induced consequences compared to FIF. When comparing the different inundation risk assessment methods, the specific force method tended to overestimate the risk area, whereas FIF tended to underestimate it. Furthermore, among all assessment methods, the influence of rainwater discharge was found to have a more dominant effect on flood risk assessment compared to the number of rainwater inflow locations. Additionally, the direction of inundation flow influenced the assessed risk, with collision-induced flow patterns leading to higher flood risk than those with identical flow directions.

Optimum Configuration, Filter Media Depth and Wastewater Load of Small-scale Constructed Wetlands for Treating the Hydroponic Waste Solution in Greenhouses (시설하우스 폐양액 처리를 위한 소형 인공습지의 최적 조합방법, 여재깊이 및 폐양액 부하량)

  • Park, Woo-Young;Seo, Dong-Cheol;Lim, Jong-Sir;Park, Seong-Kyu;Cho, Ju-Sik;Heo, Jong-Soo;Yoon, Hae-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.3
    • /
    • pp.217-224
    • /
    • 2008
  • To obtain optimum configuration, depth and load of constructed wetlands(CWs) for treating of hydroponic waste solution(HWS) which was produced in greenhouses, the study was conducted with 4 kinds of combined systems such as Vertical flow(VF)-Horizontal flow(HF), VF-VF, HF-VF and HF-HF CWs. In four configurations of CWs, the treatment efficiency of pollutants from HWS under depth of HF and VF beds, HWS loading and HWSs were investigated. Removal rate of pollutants under different depth of VF and HF in 2-stage hybrid CWs was in the order of 50 cm < 70 cm regardless of CWs configuration. Removal rate of pollutants under HWS loading in 2-stage hybrid CWs was in the order of $150L\;m^{-2}\;day^{-1}{\fallingdotseq}300L\;m^{-2}\;day^{-1}\;>\;450L\;m^{-2}\;day^{-1}$. The optimum depth and HWS loading were 70 cm and $300L\;m^{-2}\;day^{-1}$ in four configurations of CWs, respectively. Using this optimum condition, for various HWSs (cucumber, paprika and strawberry HWS), removal rate of pollutants in HF-HF CWs was higher than that in HF-VF CWs. Optimum configuration of 2-stage hybrid CWs for treating hydroponic waste solution in greenhouses was found out to be HF-HF CWs. Therefore, under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P in HF-HF CWs were 84, 81, 84, 51 and 93%, respectively.