• Title/Summary/Keyword: Flow configuration

Search Result 1,146, Processing Time 0.029 seconds

Primary Energy Conversion in a Direct Drive Turbine for Wave Power Generation

  • Prasad, Deepak Divashkar;Zullah, Mohammed Asid;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.237.1-237.1
    • /
    • 2010
  • Recent developments such as concern over global warming, depletion of fossil fuels and increase in energy demands by the increasing world population has eventually lead to mass production of electricity using renewable sources. Ocean contains energy in form of thermal energy and mechanical energy: thermal energy from solar radiation and mechanical energy from the waves and tides. The current paper looks at generating power using waves. The primary objective of the present study is to maximize the primary energy conversion (first stage conversion) of the base model by making some design changes. The model entire consisted of a numerical wave tank and the turbine section. The turbine section had three components; front guide nozzle, augmentation channel and the rear chamber. The augmentation channel further consisted of a front nozzle, rear nozzle and an internal fluid region representing the turbine housing. Different front guide nozzle configuration and rear chamber design were studied. As mentioned, a numerical wave tank was utilized to generate waves of desired properties and later the turbine section was integrated. The waves in the numerical wave tank were generated by a piston type wave maker which was located at the wave tank inlet. The inlet which was modeled as a plate wall which moved sinusoidally with the general function, $x=asin{\omega}t$. In addition to primary energy conversion, observation of flow characteristics, pressure and the velocity in the augmentation channel, rear chamber as well as the front guide nozzle are presented in the paper. The analysis was performed using the commercial code of the ANSYS-CFX. The base model recorded water power of 29.9 W. After making the changes, the best model obtained water power of 37.1 W which represents an increase of approximately 24% in water power and primary energy conversion.

  • PDF

Engineering Status of Gasification Plant in 300MW IGCC and Performance Prediction of Gasification Block (300MW급 IGCC 가스화 플랜트의 엔지니어링 현황 및 가스화 블록 성능예측)

  • Kim, Youseok;Kim, Bongkeun;Paek, Minsu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.130.1-130.1
    • /
    • 2010
  • 미국과 유럽에서는 이미 10여 년 전부터 250MW급 이상의 대용량 석탄IGCC 플랜트를 상업운전 하고 있으며, 일본과 중국을 비롯한 아시아에서도 대용량 플랜트를 시운전하고 있거나 건설 중에 있다. 한국에서는 제4차 전력수급계획에 의거 태안화력 부지 내에 300MW급 IGCC 플랜트 건설을 추진 중이며, 두산중공업은 '10년 상반기에 IGCC 가스화 플랜트에 대한 FEED 설계 (Front-Eng Engineering Design)를 완료하였다. 그 과정 중 설계조건에 의한 기본 엔지니어링 사항과 석탄 가스화 플랜트에 대한 성능예측 결과를 본 연구에서 소개한다. 가스화 플랜트의 엔지니어링은 가스화 블록과 가스정제 블록으로 구분하여 수행하였다. Process Data를 이용하여 PFD Development, P&ID Generation, Equipment Specification 개발, HAZOP 수행, Architecture Engineering 등의 순으로 FEED 설계를 진행하였다. BOD (Basis of Design)를 기준으로 운전조건별 Heat & Mass Balance와 Process Flow를 재검토하고 각 기기별 운전개념을 반영하여 P&ID를 개발하였다. 그리고 배관, 전기 및 제어에 대한 각종 Diagram 개발과 HSE (Health, Safety and Environment) 관련 설계를 수행하였다. IGCC 1호기의 엔지니어링 수행과 함께 Next 호기 자체설계 역량 확보를 위해 두산중공업은 'DIGITs'로 명명된 개념기본설계 Tool을 개발하고 있다. DIGITs는 공정모델링, 단위기기 개념설계, 공정구성 (Process Configuration) 및 종합 Database Package 형태로 구성된다. DIGITs에 의한 계산 결과 공정사 Process Data 기준시 가스화 블록 출구에서 Syngas HHV와 Syngas 현열은 각각 약 $636MW_{th}$와 약 $18MW_{th}$로, Plant 설계조건 $630MW_{th}$를 만족하는 것으로 예측되었다. 향후 DIGITs는 가스정제 블록 및 주변 BOP 설비 등과 연계한 종합 개념기본설계 Tool로써 개발 진행 중이다.

  • PDF

Numerical Analysis of Integrated Fuel Processing System Considering Thermo-Chemical Energy Balance (열/화학적 에너지 평형을 고려한 통합 연료 개질 시스템의 수치적 연구)

  • Noh, Junghun;Jung, Hye-Mi;Jung, Un-Ho;Yoon, Wang-Lai;Um, Sukkee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.111.1-111.1
    • /
    • 2010
  • This paper focuses on a systematic configuration of steam reforming fuel processor, particularly designed for small and medium sized hydrogen production application. In a typical integration of the fuel processor, there exist significant temperature gradients over the entire system which has negative effect on both catalyst life-time and system performance. Also, the volumetric inefficiency should be avoided to obtain the possible compactness for the commercial purpose. In the present work, the computational analysis will be performed to gain the fundamental insight on the transport phenomena and chemical reactions in the reformer consisting of preheating, steam reforming (SR), and water gas shift (WGS) reaction beds in the flow direction. Also, the fuel processing system includes a top-fired burner providing necessary thermal energy for endothermic catalytic reactor. A fully two-dimensional numerical modeling for a integrated fuel processing system is introduced for in-depth analysis of the heat and mass transport phenomena based on surface kinetics and catalytic process. In the model, water gas shift reaction and decomposition reaction were assumed to be at equilibrium. A kinetic model was developed and then computational results were compared with the experimental data available in the literature. Finally, the case study was done by considering the key parameters, i.e. steam to carbon (S/C) ratio and temperature. The computer-aided models developed in this study can be greatly utilized for the design of advanced fast-paced compact fuel processors research.

  • PDF

Health Supportive Design in Elderly Care Homes: Swedish Examples and their Implication to Korean Counterparts

  • Lee, Sookyoung;Dilani, Alan;Morelli, Agneta;Byun, Hearyung
    • Architectural research
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 2007
  • The objective of this research study was twofold; 1) to explore and identify health supportive design factors in Swedish elderly care homes and 2) to understand their usefulness and suggest implication in Korean elderly care settings. A descriptive and explorative method was applied using a combination of field studies and semi-structured interviews. Three study trips were carried out during Sept. $14^{th}$ and Oct. $12^{th}$ 2005; two facilities situated in Stockholm suburbs and one in the south of Sweden. According to this research, the valuable factors to support health and well-being for the elderly are as follows; 1) Community integration: These elderly care homes are generally places close to a residential area center or a city center. Services are often shared between residents and community members at large, consequently there is a flow of "visitors" of all ages connecting with the facility on a daily basis. 2) Homelike environment: A noteworthy aspect of Swedish elderly care homes is keeping the facility appearance as homelike as possible. The associations with home may be explored through the appearance and configuration of both the exterior and interior of the building. These homes seemed to be designed with a conscious aim to create a homelike setting. 3) Small scale approach: Clustering of resident rooms is one method through which the small scale approach can be achieved in larger facilities. With unit clusters, the facility can foster opportunities for social interactions among resident. 4) Accessibility to garden and nature: The courtyard is a well developed concept in planning elderly care homes in Sweden. They are generally safe and easily accessible to the residents. Studying Swedish models may provide practical knowledge of how the physical setting may improve resident's health in Korean elderly care homes.

Mutual Verification of an Analytic Model of a Complex System and Space Syntax Using Network Analyses (네트워크 분석방식 선택에 따른 복잡계 모형과 공간구문론의 상호검증)

  • Kim, Suk-Tae;Yoon, So-hee
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.3
    • /
    • pp.45-54
    • /
    • 2017
  • A social phenomenon that occurs in a physical space is said to be a complex system. However, space syntax, which is commonly employed by researchers to identify such social phenomena, has various limitations in interpreting their complexity. On the other hand, agent-based modeling considers a variety of factors including the personality of the agent, objective-oriented work flows, estimation according to time flows and better prediction of space use through diverse parameters depending the situation, as well as the characteristics of the space. The agent-based method thus has the potentials to be developed as an alternative to space syntax techniques. In particular, discrete event driven simulation(DEVS), which is part of the agent-based modeling method, embraces the concept of networks just like space syntax, which allows a possible theoretical linkage in the future. This study suggests a procedural model of agent-based DEVS reflecting two different connection methods, i.e. connections between adjacent areas and those of the entire space, and attempts to identify the relationship between the local and regional indices of space syntax. A number of spaces were selected as examples-one for a preliminary experiment and eight modified for the main experiment-and space syntax and DEVS were applied to each of them. The comparative analysis of the results led to the conclusions as follows: 1) Adjacent connections were closely related to local indices, while the whole-space approach to regional indices. Local integration shows both characteristics. 2) Observation of the time flow model indicated a faster convergence with the range of 1 to 3-fold of the total time of one lap, with the error of less than 10%. 3) The heat map analysis showed more obvious characteristics of using the space for the entire space rather than adjacent connections. 4) Space syntax shows higher eligibility than ABM.

Development of the Reading Attitudes Test Tool for Children (아동의 독서태도 검사도구 개발)

  • Park, Ju-Hyeon
    • Journal of Korean Library and Information Science Society
    • /
    • v.47 no.2
    • /
    • pp.329-358
    • /
    • 2016
  • The purpose of this study is to develop a test tool that can be measured in various aspects for the reading attitudes of children. For that it was set the configuration based on the preceding reading attitude survey and models and tacit knowledge of attitude toward reading and wrote the questions for reading attitudes. It conducted a primary and secondary test for elementary school students in grades 4-6 to verify the validity and reliability of measurement tools. 8 factors of the reading attitudes measurement tool were extracted through exploratory factor analysis and it described 66.29% of total variable. the r-value for inter-item consistency about reading attitudes were above 0.4 on all questions. The Cronbach ${\alpha}$-value of reliability coefficient about reading attitudes measurement tool was 0.950. Therefore Reading attitude test tool have reading usefulness, reading efficacy, leisure, stiumulation, flow, expression, study, assertiveness as sub factors of reading attitude has been shown that it can serve as a useful tool for measuring various aspects of the reading attitude for children.

Simulation of the tensile failure behaviour of transversally bedding layers using PFC2D

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Marji, Mohammad Fatehi
    • Structural Engineering and Mechanics
    • /
    • v.67 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • In this paper, the tensile failure behaviour of transversally bedding layers was numerically simulated by using particle flow code in two dimensions. Firstly, numerical model was calibrated by uniaxial, Brazilian and triaxial experimental results to ensure the conformity of the simulated numerical model's response. Secondly, 21 circular models with diameter of 54 mm were built. Each model contains two transversely bedding layers. The first bedding layer has low mechanical properties, less than mechanical properties of intact material, and second bedding layer has high mechanical properties, more than mechanical properties of intact material. The angle of first bedding layer, with weak mechanical properties, related to loading direction was $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $75^{\circ}$ and $90^{\circ}$ while the angle of second layer, with high mechanical properties, related to loading direction was $90^{\circ}$, $105^{\circ}$, $120^{\circ}$, $135^{\circ}$, $150^{\circ}$, $160^{\circ}$ and $180^{\circ}$. Is to be note that the angle between bedding layer was $90^{\circ}$ in all bedding configurations. Also, three different pairs of the thickness was chosen in models; i.e., 5 mm/10 mm, 10 mm/10 mm and 20 mm/10 mm. The result shows that In all configurations, shear cracks develop between the weaker bedding layers. Shear cracks angel related to normal load change from $0^{\circ}$ to $90^{\circ}$ with increment of $15^{\circ}$. Numbers of shear cracks are constant by increasing the bedding thickness. It's to be note that in some configuration, tensile cracks develop through the intact area of material model. There is not any failure in direction of bedding plane interface with higher strength.

Air-Side Performance of Fin-and-Tube Heat Exchanger with Copper Plate or Copper Spiral Fins (구리 재질의 평판 핀과 나선형 핀이 사용된 핀-관 열교환기의 공기측 성능)

  • Lee, Jin-Wook;Park, Ji-Hoon;Lee, Jung-Pyo;Kim, Nae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.269-278
    • /
    • 2011
  • We investigate the heat-transfer and pressure-drop characteristics of fin-and-tube heat exchangers with a copper plate or copper spiral fins. Twenty-four samples with different fin pitches and tube rows were tested. For both configurations, the effect of the fin pitch on the j factor is negligible, and the f factor increases with the fin pitch. The effect of the tube row depends on the configuration. For plate fin-and-tube heat exchangers, the j factor decreases as the row number increases; the reverse is true for spiral exchangers. We explain this by considering the flow pattern. The j factor for plate fin-and-tube heat exchangers is larger than that for spiral exchangers, and the difference decreases as the row number increases. The f factor of the plate fin-and-tube heat exchanger is also larger. We compare our results with existing predictions of correlations.

A numerical investigation on the oblique shock wave/vortex interaction (경사충격파와 와류간의 상호작용에 관한 수치적 연구)

  • Moon, Seong-Mok;Kim, Chong-Am;Rho, Oh-Hyun;Hong, Seung-Kyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.8
    • /
    • pp.20-28
    • /
    • 2004
  • For the prediction on the onset of oblique shock wave-induced vortex breakdown, computational studies on the Oblique Shock wave/Vortex Interaction (OSVI) are conducted and compared with both experimental results and analytic mode1. A Shock-stable numerical scheme, the Roe scheme with Mach number-based function (RoeM), and a two-equation eddy viscosity-transport approach arc used for three-dimensional turbulent flow computations. The computational configuration is identical to available experiment, and we attempt to ascertain the effect of parameters such as a vortex strength, streamwise velocity deficit, and shock strength at a freestream Mach number of 2.49. Numerical simulations using the k-w SST turbulence model and suitably modeled vortex profiles are able to accurately reproduce many fine features through a direct comparison with experimental observations. The present computational approach to determine the criterion on the onset of oblique shock wave-induced vortex breakdown is found to be in good agreement with both the experimental result and the analytic prediction.

Performance Evaluation of Two-Equation Turbulence Models for 3D Wing-Body Configuration

  • Kwak, Ein-Keun;Lee, Nam-Hun;Lee, Seung-Soo;Park, Sang-Il
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.3
    • /
    • pp.307-316
    • /
    • 2012
  • Numerical simulations of 3D aircraft configurations are performed in order to understand the effects of turbulence models on the prediction of aircraft's aerodynamic characteristics. An in-house CFD code that solves 3D RANS equations and two-equation turbulence model equations are used. The code applies Roe's approximated Riemann solver and an AF-ADI scheme. Van Leer's MUSCL extrapolation with van Albada's limiter is also adopted. Various versions of Menter's $k-{\omega}$ SST turbulence models as well as Coakley's $q-{\omega}$ model are incorporated into the CFD code. Menter's $k-{\omega}$ SST models include the standard model, the 2003 model, the model incorporating the vorticity source term, and the model containing controlled decay. Turbulent flows over a wing are simulated in order to validate the turbulence models contained in the CFD code. The results from these simulations are then compared with computational results from the $3^{rd}$ AIAA CFD Drag Prediction Workshop. Numerical simulations of the DLR-F6 wing-body and wing-body-nacelle-pylon configurations are conducted and compared with computational results of the $2^{nd}$ AIAA CFD Drag Prediction Workshop. Aerodynamic characteristics as well as flow features are scrutinized with respect to the turbulence models. The results obtained from each simulation incorporating Menter's $k-{\omega}$ SST turbulence model variations are compared with one another.