• Title/Summary/Keyword: Flow conditions

Search Result 7,185, Processing Time 0.034 seconds

Comparison of the Flame Height of Pool Fire according to Combustion Models in the FDS (FDS의 연소모델에 따른 풀화재의 화염높이 비교)

  • Han, Ho-Sik;Hwang, Cheol-Hong;Oh, Chang Bo;Choi, Dongwon;Lee, Sangkyu
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.42-50
    • /
    • 2018
  • The effect of sub-grid turbulence and combustion models on the mean flame height in a heptane pool fire according to the Fire Dynamics Simulator (FDS) version (5 and 6) based on Large Eddy Simulation (LES) was examined. The heat release rate for the fire simulation was provided through experiments performed under identical conditions and the predictive performance of the mean flame height according to FDS version was evaluated by a comparison with the existing correlation. As a result, the Smagorinsky and Deardorff turbulence models applied to FDS 5 and 6, respectively, had no significant effects on the mean flow field, flame shape and flame height. On the other hand, the difference in pool fire characteristics including the mean flame height was due mainly to the difference in the mixture fraction and Eddy Dissipation Concept (EDC) combustion models applied to FDS 5 and 6, respectively. Finally, compared to FDS 6, FDS 5 provided the predictive result of a significantly longer flame height and more consistent mean flame height than the existing correlation.

Extraction and Physicochemical Characterization of Barley Bran $\beta$-glucan (보리겨 $\beta$-glucan의 추출 및 이화학적 특성)

  • 김선영;유정희
    • Korean journal of food and cookery science
    • /
    • v.19 no.5
    • /
    • pp.616-623
    • /
    • 2003
  • Waxy barley brans were collected during the pearling process. The extraction of $\beta$-glucan from barley bran was effected by the extraction conditions. The $\beta$-glucan content increased with temperature, but not with pH. The highest yield, 6.5%, was achieved at pH 7.0 and 55$^{\circ}C$. At pH 10 and 45$^{\circ}C$, 48.5% of the $\beta$-glucan in barley bran was recovered in the gum product, with 54.6% purity. The protein and starch contaminations were high, reaching 13.6 and 23.7%, respectively. The $\beta$-glucan content was greatest in the subaleurone and aleurone regions (bran fractions 1, 2, 3 and 4), and declined considerably toward the inner layers. A monosaccharide analysis of the purified, $\beta$-glucan, from bran fractions 1, 2, 3 and 4, indicated that glucose constituted the majority of the gum. The small amounts of the arabinose and xylose found in the gum may indicate the presence of arabinoxylans as minor constituents. The molecular weights of the $\beta$-glucans isolated from bran fractions 1,2 and 3 were found to be 4.09${\times}$10$^{5}$ ∼-4.41${\times}$10$^{5}$ . The major glycosidic linkages of the $\beta$-glucans demonstrated the presence of 2, 4, 6-Me-Glc and 2, 3, 6-Me-Glc. When flow behaviors of barley bran $\beta$-glucan were examined, $\beta$-glucan exhibited pseudoplastic fluid properties.

A Study on Numerical Analysis for Internal PEMFC Cooling of Power Pack for UPS (UPS 파워 팩 내부 연료전지의 냉각특성에 대한 수치 해석)

  • Song, Jun-Seok;Kim, Byeong-Heon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.527-535
    • /
    • 2017
  • Heat management is one of the most critical issues in Polymer Electrolyte Membrane Fuel Cells (PEMFCs) installed inside the fuel cell power pack of a fuel cell battery hybrid UPS. If the heat generated by the chemical reaction in the fuel cell is not rapidly removed, the durability and performance of the fuel cell may be affected, which may shorten its lifetime. Therefore, the objective of this study is to select and propose a proper cooling method for the fuel cells used in the fuel cell power pack of a UPS. In order to find the most appropriate cooling method, the various design factors affecting the cooling performance were studied. The numerical analysis was performed by a commercial program, i.e., COMSOL Multiphysics. Firstly, the surface temperature of the 1 kW class fuel cell stack with the cooling fans placed at the top was compared with the one with the cooling fans placed at the bottom. Various rotation speeds of the cooling fan, viz. 2,500, 3,000, 3,500, and 4,000 RPM, were tested to determine the proper cooling fan speed. In addition, the influence of the inhaled air flow rate was investigated by changing the porous area of the grille, which is the entrance of the air flowing from the outside to the inside of the power pack. As a result, it was found that for the operating conditions of the 1 kW class PEMFC to be acceptable, the cooling fan was required to have a minimum rotating speed of 3500 RPM to maintain the fuel cell surface temperature within an acceptable range. The results of this study can be effectively applied to the development of thermal management technology for the fuel cells inside the fuel cell power pack of a UPS.

Study on the Applicability Analysis of HPLC for Fuel Marker (Unimark 1494DB) in Petroleum Products (석유제품의 식별제(Unimark 1494DB) 분석을 위한 HPLC 적용가능성 분석 연구)

  • Hwang, In-ha;Youn, Ju-min;Doe, Jin-woo;Park, Tae-seong;Kang, Hyung-kyu;Ha, Jong-han;Na, Byung-gi
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.1076-1084
    • /
    • 2017
  • For analyzing the qualitative and quantitative analysis of fuel marker in petroleum products, the applicability of HPLC was studied. For the qualitative analysis of fuel marker in kerosene and automotive diesel, optimal analytical conditions(ratio of mobile phase solvent, flow rate, etc) in HPLC were selected and calibration curve for quantitative analysis of fuel marker was prepared based on the result of qualitative analysis. In particular, the correlation coefficient of calibration curve in kerosene and automotive diesel was shown to be 0.999 in a certain concentration range and it could be applied to the quantitative analysis. The results of analysis using the UV/Vis spectrometer, which is the current analysis method of fuel marker, were compared with the analysis results using the HPLC. The kerosene showed a low deviation of about 7 % and the automotive diesel showed a somewhat large deviation of about 20 %.

Triboelectrostatic Separation of Unburned Carbon from Flyash for Ash Recycling (마찰대전 정전분리기를 이용하여 석탄회에 함유된 미연탄소분 제거에 관한 연구)

  • 이재근;김성찬;손낙원;김두현;오정근
    • Resources Recycling
    • /
    • v.6 no.3
    • /
    • pp.15-21
    • /
    • 1997
  • Flyash from a coal-hed power plan1 is produced approximtcly 3 million tons m 1996 and causes the serious environmentalpmblem due to the disposal in the ash pond. Flyash is an accepted additive in concrete where it adds strength, sulfate ateresistanceand reduced cost, provided acccptablc levcls of unbunrned carbon are mmtmed This papzr describes to investigate thc technicalfeasibility of a dry triboelcctrostatlcp roccss to scparate unburned carbon h m f lyash into economically valuable produck Puliclesof unburned carbon and flyash can be impded positivc and negative surface charzes. rcapeclively. with a copper tniochargcr dueto dirferences in the work function values of thc particles and the tnbacharger. and cm he separated by passing thcm throuph anexternal electic field. A laboratory s d e separation system consists of r sacw feeder for ash supply, a tniocharger, verticalcollecling copper plates, power supplies, a flow meter, and a fan. Separation tests taking into account separahian efficiency and ashrecovery showed that flyash recovery was sh-nngly dependent an thc tnbocharger geomzhy, elect"c ficld strength. flyssh s ~ c a,n dash feeding late. Optimal separation conditions were flyash size less than 125 Fm and electric field shcngrh of 200 kV1m. Ovcr 80%of the flyash with 7% lass on ignition was recovered at wrbon contznts less than 3%bon contznts less than 3%

  • PDF

A Study on the natural Convection and Radiation in a Rectangular Enclosure with Ceiling Vent (천장개구부를 갖는 정사각형 밀폐공간내의 자연대류-복사 열전달에 관한 연구)

  • Park Chan-kuk;Chu Byeong-gil;Kim chol;Jung Jai-hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.28-39
    • /
    • 1998
  • This study investigated the natural convection and radiation in a rectangular enclosure with ceiling vent experimentally and numerically. A heat source is located on the center of the bottom surface. The analysis was peformed a pure convection and is combination of natural convection and radiation. The shape of the considered two dimensional model is a square whose center of ceiling($30\%$) is opened. The numerical simulations are carried out for the pure natural convection case and the combined heat transfer case by using the SIMPLE algorithm. For the turbulent flow, Reynolds stresses are closed by the standard $k-{\epsilon}$ model and the wall function is used to determine the wall boundary conditions. The experiment was performed on the same geometrical shape as the computations. The radiative heat transfer is analized by the S-N discrete ordinates method. The results of pure natural convection are compared with those of combined heat transfer by the velocity vectors, stream lines, isothermal lines. The results obtained are as follows 1. Comparing the results of pure convection with those of the combined convection-radiation through the shape of stream lines, isothermal lines are similar to each other. 2. The temperature fields obtained by numerical method are compared to those obtained by experimental one, and it is found that they are showed mean relative error $8.5\%$. 3. Visualization bt smoke is similar to computational results.

  • PDF

Analysis on the Water Circulation and Water Quality Improvement Effect of Low Impact Development Techniques by Test-Bed Monitoring (시범 단지 운영을 통한 LID 기법별 물순환 및 수질개선 효과 분석)

  • Ko, Hyugbae;Choi, Hanna;Lee, Yunkyu;Lee, Chaeyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.5
    • /
    • pp.27-36
    • /
    • 2016
  • Low Impact Development (LID) techniques are eco-friendly storm water management process for water circulation restoration and non-point pollutant reduction. In this study, four LID techniques (Small constructed wetland, Infiltration trench box, Infiltration trench, Vegetated swale) were selected and installed as a real size at the real site. All facilities were evaluated as monitoring under the real environmental climate situation and an artificial rain with exceeding design rainfall. In various rainfall, runoff reduction efficiency and non-point pollutant removal efficiency are increased to the bigger Surface Area of LID (SA)/Catchment Area (CA) ratio and the bigger Storage Volume of LID (SV)/Catchment Area (CA) ratio. Runoff did not occur at all rainfall event (max. 17.2 mm) in infiltration trench and vegetated swale. But Small constructed wetland was more efficient at less than 10 mm, a efficiency of infiltration trench box was similar at different rainfall. Although different conditions (such as structural material of LID, rainfall flow rate, antecedent dry periods), LID techniques are good effects not only water circulation improvement but also water quality improvement.

Optimal valve installation of water distribution network considering abnormal water supply scenarios (비정상 물공급 시나리오를 고려한 상수도관망 최적 밸브위치 결정)

  • Lee, Seungyub;Jung, Donghwi
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.10
    • /
    • pp.719-728
    • /
    • 2019
  • Valve in water distribution network (WDN), that controls the flow in pipes, is used to isolate a segment (a part of WDN) under abnormal water supply conditions (e.g., pipe breakage, water quality failure event). The segment isolation degrades pressure and water serviceability in neighboring area during the water service outage of the segment. Recent hydraulic and water quality failure events reported encouraging WDN valve installation based on various abnormal water supply scenarios. This study introduces a scenario-based optimal valve installation approach to optimize the number of valves, the amount of undelivered water, and a shortest water supply path indicator (i.e., Hydraulic Geodesic Index). The proposed approach is demonstrated in the valve installation of Pescara network, and the optimal valve sets are obtained under multiple scenarios and compared to the existing valve set. Pressure-driven analysis (PDA) scheme is used for a network hydraulic simulation. The optimal valve set derived from the proposed method has 19 fewer valves than the existing valve set in the network and the amount of undelivered water was also lower for the optimal valve set. Reducing the reservoir head requires a greater number of valves to achieve the similar functionality of the WDN with the optimal valve set of the original reservoir head. This study also compared the results of demand-driven analysis (DDA) and the PDA and confirmed that the latter is required for optimal valve installation.

A Study of Heat Transfer during Freezing Process of Water in a Vertical Cylinder - Comparison of thermal storage performance on the working fluid direction - (수직원통형 축열조내 물의 응고과정시 열전달에 관한 실험적연구 - 작동유체의 유동방향에 따른 열저장성능 비교 -)

  • Heo, K.;Kim, Y.K.;Kim, Y.J.;Kim, J.K.;Yim, C.S.
    • Solar Energy
    • /
    • v.15 no.2
    • /
    • pp.77-90
    • /
    • 1995
  • An effective heat transfer during freezing process was proposed in the vertical cylinder to improve the effectiveness of the heat storage. Vertical cylinder was filled with pure water in order to investigate ice-shape, temperature distribution of the liquid, temperature distribution of the cylinder tube wall, total heat storage per unit mass in the test section under the two experimental conditions; inlet temperature of working fluid is constant($-10^{\circ}C$) and inlet direction of working fluid is either upward flow or downward. Both the mean temperature of the liquid and temperature difference of cylinder tube wall in the upward were lower than those in the downward. In case that the initial temperature of water was $7^{\circ}C$ and $4^{\circ}C$, the shape of ice layer in the upward was more uniform than that in the downward. In case of $1^{\circ}C$, the shape of ice layer is formed by inlet direction of working fluid. Finally, time-varying total heat energy stored in the water in the upward was higher than that in the downward.

  • PDF

Heterogeneous Photocatalytic Decomposition of Organics in Water Phase ($TiO_2$ 광촉매를 활용한 수용액 내의 유기물질의 광분해반응)

  • Lee, Tai-K.;Kim, Dong-H.;Kim, Kyung-N.;Auh, P. Chung-Moo
    • Solar Energy
    • /
    • v.15 no.2
    • /
    • pp.65-75
    • /
    • 1995
  • We have summarised some important aspects of our recent basic and applied studies in the area of photocatalytic detoxifcation with Degussa P25 titanium dioxide($TiO_2$) being the photocatalyst. Heterogeneousphotocatalytic decompositions of two components such as TCE-chloroform, TCE-phenol and TCE-benzene as well as single component organic, TCE, chloroform and $CCl_4$ were carried out to investigate the effect of additional compound on the TCE decomposition rate. In laboratory experiments, the optimum flow rate of TCE solution was $200cm^3/min$ with annular photoreactor in the presence of 0.1 wt% $TiO_2$ powder under illumination. It was observed that the second compound such as $CHCl_3$, phenol and benzene has a negative effect on the TCE decomposition rate. Result presented that TCE decomposition ratio was increased at low pH in the TCE-phenol two component solution. It could be shown that the photocatalytic reactor exhibits technical feasibility of detoxifying the multicomponent under proper experimental conditions.

  • PDF