The aerodynamic and aeroacoustic performance of discharge grille of outdoor unit of air-conditioner was investigated in this study. Discharge grille is one of outdoor unit's important parts to affect the flow rate and Overall Sound Pressure Level(OSPL). New type of discharge grille was suggested based on the results of numerical simulation. To simulate the flow pattern near the propeller fan, commercial flow solver FLUENT was used. Sliding mesh method was used for rotating propeller fan and initial condition for unsteady model was calculated by Multiple Reference Frame(MRF) method. To minimize the interaction noise between fan blade wake and discharge grille, new discharge grille has radial rib which is aligned with trailing edge of fan blade. And inclined radial rib was adopted for reducing flow rate drop in discharge grille. The optimization of inclined angle of radial grille was performed experimentally.
This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit by investigating the effects of fan location and shroud shape. To determine optimal design parameters, we investigated the exhaust flow rate by changing shroud height, fan height, fan guide height, and fan width. The 3rd order central composite design was performed to select three most important parameters affecting the exhaust flow rate. According to the result of response surface method, the exhaust flow rate of the optimum model increased by 6.25% compared to that of the base model.
Cycle simulation of the air-conditioner was carried out using a number of candidate alternatives to R22;R32/R125/R134a(30/10/60, by mass percent), R32/R125/R134a(10/70/20), R32/R134a(25/75), R32/R134a(30/70), R32/R125(60/40), R290(propane) and R134a. In this study, we considered only the basic parts of the air-conditioner such as the compressor, the evaporator, the condenser and the capillary tube, for the purpose of analysis. The performance characteristics of alternatives considered here were examined by comparing with the case using R22 at the constant volumetric flow rate condition. The results of our analysis revealed that the use of refrigerant mixtures, R32/R134a(30/70) and R32/R125/R134a(30/10/60), was appropriate for the alternatives to R22 in view of the cooling capacity and the COP. For the case of using R134a and R290, the COP was observed to increase under the same volumetric flow rate condition, but the cooling capacity was substantially decreased. Therefore the use of R134a and R290 should be accompanied with increasing considerably the size of compressor in order to maintain the same cooling capacity of R22.
This paper proposes a new computational aeroacoustics method for an axial fan analysis. The major aeroacoustic noise source of an outdoor air-conditioner is the axial fan. It was revealed that the dominant noise source is the aerodynamic interactions between the rotating blade and stationary orifice. Many researches were focused on the fan only case. However, it does not fit to a real outdoor unit of air-conditioner. Especially, the inlet part of the axial fan of real system case is complex and not uniform. So, in order to identify the dominant noise source of axial fan, full outdoor unit analysis is important. Transient CFD analysis of full system was performed by commercial CFD code - SC/Tetra. Dominant noise source of the system was calculated by commercial CFN code - FlowNoise. The results show that not only BPF peaks but also broadband noise are similar to the measured data.
The computational flow analysis using LES technique was carried out to investigate the flow characteristics of a sirocco fan under the maximum flowrate condition. The commercial SC/Tetra software was used for this unsteady and three-dimensional numerical analysis. In consequence, because a flow is unstable within the range of about 50% of a housing depth from a bellmouth around the cutoff region, the passing flow through the blade cascade occurred on the X-Y plane is a slow or a reverse with approaching to the housing inlet. Also, the secondary flow shows on the radial plane of a housing, and its vortex center exists within about 33% of a housing depth from a bellmouth except the cutoff region. Moreover, the flow occurring on the exit plane of a sirocco fan shows a complex secondary flow.
Whole flow fields of a room air conditioner (RAC) have been visualized by a Particle Image Velocimetry (PIV) technique to analyze the flow structure by various inlet and outlet angles, and to control an eccentric vortex which affects an efficiency and noise of the RAC. A test model with 5 stages of a cross flow fan has been manufactured and a transparent acryl has been installed at the side of the test model for the PIV experiment. The inlet and outlet flows and the flow inside the cross flow fan have been analyzed by varying the inlet grill angles and outlet blade angles. The movement of the eccentric vortex has been investigated experimentally by developing the measurement technique for the inner flow field of the cross flow fan, and the relationship between the control of the eccentric vortex and the inlet and outlet angles has been confirmed in this study.
Numerical simulations and experiments were conducted to analyze the design parameters for a slim room air-conditioner. These design parameters included a fan shape, a front panel, a scroll shape, a bell mouth, a distance between a fan and a heat exchanger, etc. Each design parameter was analyzed numerically and/or experimentally in terms of the flow rate and the sound pressure level, which should be the most influential factors for developing the slim room air-conditioner. The fan with a uniform height showed a better performance than that with a linearly varying height. It is recommended to use a front grill rather than a front panel according to sound pressure levels since the front panel itself is a huge resistance to the inlet flow. A redesigned scroll shape by changing the rotational direction of a fan also contributed a lot to lowering the sound pressure level. There existed a distance between a fan and a heat exchanger, where flow rates increased effectively.
The purpose of this study was to reduce the airborne noise emitted from the package air-conditioner(PAC) therefore, the optimim design melthods of the fans and the flow-paths were investigated experimentally through the anlaysis of the nose problems caused by the conventional PAC system, and the fan performance tests and the systme resistance measurements of the parts which belong to the flow-paths of the PACwere used to study these noise problems. As a results, through the optimized flow-paths of the new PAC system with the lowset system resistance, and by adjusting and matching the operating point of each fan to each PAC system, the airborne noise reductions from the new indoor PAC and the outdoor one were achieved upto 5.5 dBA and 6.6 dBA respectively in overall noise level as compared with the conventional PAC system.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.