• 제목/요약/키워드: Flow conditioner

검색결과 172건 처리시간 0.025초

전동차 공조기 덕트 내의 유동특성에 관한 수치해석적 연구 (Numerical study on the flow characteristics in Air-conditioner duct of EMU)

  • 김승택;김성종;박근수;박형순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.345-350
    • /
    • 2003
  • The inside of EMU is supplied with the cooling air from air-conditioner and the fresh air from exterior through the air-conditioner duct which is one of the air conditioning system. The shape of air-conditioner duct is a major factor in determining the air-conditioning efficiency, thermal comfort and energy efficiency. Therefore, this study is to understand the flow characteristics in the air-conditioner duct by three dimensional numerical simulation. The air-conditioner duct was calculated for the design volume flow rate, $2,726\;m^3/h/unit$. From the result of calculation and measurement, the velocity at diffuser outlet presented good agreement in general. [n this present study, the calculation was also performed for three volume flow rate(1,800, 2,200, 3,000 $m^3/h/unit$) and total pressure characteristic curve with volume flow rate was presented.

  • PDF

Reduction of the Refrigerant-Induced Noise from the Transition of Flow Pattern by Decreasing Tube Diameter

  • Takushima, Akira;Han, Hyung-Suk;Jung, Wei-Bong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권2호
    • /
    • pp.37-44
    • /
    • 2009
  • It is well known that a refrigerant-induced noise is caused by two-phase flow in the indoor unit of a heat pump air-conditioner. Especially when the flow pattern in a pipe is intermittent flow, the irregular noise occurs frequently. But it is very difficult to avoid this kind of the noise for the application of air-conditioner. Therefore, in this research, the flow patterns at two-phase flow state in a pipe of the indoor unit for the air-conditioner are researched using cycle simulator at typical cycle conditions. In order to find the relationship between refrigerant-induced noise and flow pattern, the noise patterns are investigated with respect to the estimated flow pattern from the various flow pattern maps. Base on the estimations of the flow patterns by those maps, the refrigerant-induced noise is evaluated as decreasing tube diameter, which can transit the flow pattern from slug to annular flow.

차량용 에어컨의 성능에 미치는 인자에 관한 연구 (Parametric Study on Performance of an Automobile Air Conditioner)

  • 박윤철;권기린
    • 동력기계공학회지
    • /
    • 제6권4호
    • /
    • pp.16-22
    • /
    • 2002
  • This study was conducted to find performance evaluation method for automobile air conditioner. Experimental facilities were constructed to simulate wide range of operating condition for the automobile air conditioner. Compressor speed was controled by variable speed electric motor and the power was measured through torque transducer and tachometer was used to measure compressor speed. Parametric studies were conducted in this study, to figure out effect of environment variables on the performance of the automobile air conditioner. The environmental variables are inlet air temperature, relative humidity and air flow rate for the evaporator and inlet air temperature and air flow rate for the condenser. Compressor speed is also changed. The results of this study shows that air flow rate of the evaporator is more sensitive to the performance of the automobile air conditioner than the other variables. However relative humidity of the inlet air of the evaporator strongly affects capacity rather that COP.

  • PDF

축류팬 및 슈라우드 개선을 통한 공조기 저소음화에 대한 연구 (Study on Noise Reduction of an Air Conditioner through Modification of Axial Flow Fans and Shrouds)

  • 김창준;윤홍열;정용규;박영민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.380-387
    • /
    • 2000
  • In this paper, a successful result of modification of an axial flow fan and a shroud for noise reduction of a window type air conditioner is presented especially in order to verify the importance of blade shape improvement and the searching for the optimal shape of shrouds. Effective ways to work out the result as mentioned above are to make the tip of the blade varied in thickness and to have special shapes. From the viewpoint of the shape in a shroud, several cases were examined and the particular value of a design parameter of the shroud was acquired to get the best noise reduction of an air conditioner. Through the application of the methods, the air conditioner became less noisy by 4.5 dB(A) in terms of air-borne noise produced only by the axial flow fan and consumed less energy by 20.9% compared to the current one.

  • PDF

룸에어컨 내부 유동의 과도현상에 대한 수치적 연구 (Transient Flow Characteristics of the Room Air Conditioner)

  • 서현석;김진백;김윤제
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.526-529
    • /
    • 2008
  • Air Conditioner has become a popular comfort providing device since two decades, whether in an office or home especially for warm and wet climate countries. The RAC (Room Air Conditioner) is widely used in various working spaces and residences. It composed of heat exchager, cross-flow fan, stabilizer, rearguider and blade of diffuser region, etc. In this study, numerical analyses based on the prediction of transient phenomena were carried out to investigate the flow characteristics in the RAC, including the impeller, the rearguider, the stabilizer and the blade of the diffuser region. Using a commercial code, FLUENT, the velocity, pressure and streamlines were obtained with unsteady, turbulent flow and no-slip condition. The angular velocities of impeller are located in the 900 rpm. Turbulent closure was achieved using a standard k-${\varepsilon}$ model. A moving reference frame (MRF) approach was adopted to simulate the flow field generated by impeller in the RAC. Results were graphically depicted with various geometrical configurations and operating conditions.

  • PDF

천장형에어컨 기류가 화재감지기 작동에 미치는 영향 분석 (Study on Influence of Air Flow of Ceiling Type Air Conditioner on Fire Detector Response)

  • 최문수;이근오
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.40-45
    • /
    • 2018
  • 이 논문은 천장형 에어컨의 기류가 화재감지기 작동에 미치는 영향을 분석한 연구이다. 천장형 에어컨의 기류를 형성시킨 가운데 화재감지기의 작동특성을 분석하기 위하여 ISO표준에서 규정한 방법으로 화재실험을 수행하였다. 실험은 10 m (가로) ${\times}$ 7 m (세로) ${\times}$ 4 m (높이) 크기의 화재실험장에서 수행하였다. 실험에 사용된 화재감지기는아날로그식 열감지기와 아날로그 연기감지기이다. 화원으로는 열감지기 작동을 위해 n-heptane을 사용하였고, 연기 감지기 작동을 위해 면심지(Cotton)를 사용하였다. 실험 결과, 화재감지기의 응답은 기류가 없을 때는 화원으로부터 거리가 멀어질수록 늦어지는 패턴을 보이나, 강한 기류에서는 그 패턴이 유지되지 못한 것을 확인하였다. 천장형 에어컨 기류가 없는 경우에 비해 기류가 강한 경우에 응답시간이 연기감지기는 121%, 열감지기는 39% 늦어졌다. 천장형 에어컨이 설치된 장소에서는 화재감지기 개수를 늘려 풍구 4방향에 모두 설치하거나 감도가 뛰어난 감지기를 설치하는 것이 화재의 조기감지를 위해 필요할 것으로 판단된다.

열전모듈을 이용한 에어컨의 방열부 냉각특성에 대한 연구 (Cooling Characteristics at Hot Side of the Thermoelectric Module for an Air Conditioner)

  • 김서영;강병하;장혁재;김석현
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.214-220
    • /
    • 2002
  • A small air conditioner using thermoelectric module has been designed and built. Three types of cooling methods, such as air cooling, closed-loop water cooling, and evaporative cooling, for hot side of thermoelectric module have been investigated. Among three types of cooling method, the evaporative cooling method is seen to be the most effective to achieve the steady state operation of a thermoelectric air conditioner The system performance with evaporative cooling method are also studied in detail for several oprating parameters, such as input power to the thermoelectric module, water or air flow rate at the hot side, and air flow rate at the cold side. The results obtained indicate that the cooling capacity of a system is increased with an increase in the input power to the thermoelectric module while the system COP is decreased. It is also found that the optimal air flow rate as well as water flow rate at the hot side is needed for the best system performance at a liven operating condition. Both the system COP and cooling capacity are increased as the air flow rate at cold side is increased.

Differentiated Service에서 공정한 자원 공유를 위한 Traffic Conditioner 설계 (A Design Traffic Conditioner for Fairness Resource share in Differentiated Service)

  • 이진호;김용수;장경성;김병기
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2000년도 봄 학술발표논문집 Vol.27 No.1 (A)
    • /
    • pp.310-312
    • /
    • 2000
  • 명시적인 자원 할당과 스케줄링에 의해 QoS를 제공 할 수 있는 방안으로 RSVP가 제안되었으나 내부 구조 변경이나 확장성의 문제를 내포하고 있다. 그래서 IETF에서는 차등 서비스(Differentiated Service)를 이용하여 서비스 영역을 확장하려는 연구가 활발히 진행중이다. DiffServ는 확장성을 고려하여 RSVP와 같은 개별 flow에 대한 QoS 제공이 아닌 flow들의 집합(aggregated)으로 차등적인 서비스를 제공하는 방법이다. 본 논문에서는 aggregated flow로 서비스를 제공할 때 불특정 flow에 대한 QoS 손실을 막기 위해 Token Bucket Meter 처리 전에 사전 모니터링에 의해 자원공유의 공정성과 처리 속도를 향상시킬 수 있는 TC(Traffic Conditioner)를 설계, 구현하여 다수 subnetwork에서의 flow가 자원을 공정하게 공유함을 결과로 보였다.

  • PDF

유동 양식 선도를 이용한 에어컨 실내기의 냉매 소음 저감 분석 (Experimental Study of the Refrigerant Induced Noise for Air Conditioner Using Flow Pattern Map)

  • 한형석;모진용;정의봉
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.957-963
    • /
    • 2008
  • The refrigerant-induced noise of the air conditioner is one of the irregular noises which occurs at the indoor unit. Because the air-conditioner makers are always trying to reduce the sound pressure level radiated from indoor unit, reducing the refrigerant-induced noise at low cooling mode is very important problem. But it is very difficult to estimate whether the refrigerant-induced noise occurs or not before it becomes problem. In this paper, a method to predict the refrigerant-induced noise is suggested using flow pattern map. It is estimated that the irregular noise from the refrigerant comes from the slug flow in a pipe.

  • PDF

자동차 에어컨용 평행류 응축기의 성능평가 (Performance Evaluation of a Parallel Flow Condenser for Automotive Air Conditioners)

  • 장혁재;강병하
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.247-253
    • /
    • 2003
  • The new shape of louver-fin has been applied to a parallel flow condenser to enhance air-side heat transfer rate lot an automotive air-conditioner R- l34a is employed as a refrigerant inside the flat tube of the condenser, This problem is of particular interest in reducing the geometric size of the automotive air conditioner The effect of air flow rate on pressure drop as well as heat transfer in air side are studied in detail. Comparison of the performance is also made with that of a conventional parallel flow condenser, which is available in the market. The results obtained indicate that the total pressure drop through the pre sent condenser is not changed, while the heat transfer rate is increased by 24% at high veto city of air flow, compared with those of the conventional condenser. The parallel flow condenser with a new shape of louver-fin could be reduced in size by 20% for the equivalent condenser capacity, compared with the conventional parallel flow condenser.