• 제목/요약/키워드: Flow coefficients

검색결과 1,534건 처리시간 0.022초

배수갑문의 유량계수 결정에 대한 실험적 연구 (ExPerimental Study on the Determination of Discharge Coefficients in Tide Gates)

  • 권순국;나정우
    • 한국농공학회지
    • /
    • 제28권1호
    • /
    • pp.51-59
    • /
    • 1986
  • Through the hydraulic model test, a more convenient and accurate method of deter- mining discharge coefficients in the sluice type of tide gates can be derived by the use of aubmergence ratio as a parameter. The results obtained are summarized as follows; 1. Discharge coefficients under submerged flow conditions can be obtained by the application of sutmergerice ratio (S) to the free flow equation of the broad-erested we r. 2. The critical submergence ratios (Scr) for the flat basin and the broad-crested types of sill have the same value of 0.8. 3. Under free flow conditions, the discharge coefficient (m) are 0.37 and 0. 35 for the flat basin and the broad-crested types of sill respectively. However, when submerged flow condition exists, the discharge coefficients for both types of sill is given by a regression equation of discharge coefficients (IL) on submergence ratios (8) expressed as; m 1.3- 1. 17S. 4. The relationships between S and Froude number (Fr), for the flat basin and the broad-crested types of sill are Fr=2. 79-2.495 and Fr2.5=5. 7-6.16S respectively. From the above relationships, it can be concluded that m can also be expressed in terms of the Froude number which is a very relevant hydraulic parameter of the open channel hydraulics.

  • PDF

정상유동장치를 이용한 유량계수 측정에 관한 실험적 연구 (An Experimental Study on Measurement of Flow Coefficient Using the Steady-Flow Test Rig)

  • 박상욱;최익수;노기철;류순필;윤건식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권4호
    • /
    • pp.423-429
    • /
    • 2012
  • 밀러 사이클은 저배기 및 고효율 달성으로 Tier II 규제뿐만 아니라 $CO_2$ 저감을 동시에 달성할 수 있는 기술로 알려져 있다. 그러나 이를 위해서는 충분한 흡입공기량이 확보되어야 하며 흡기계통은 공기저항을 최소화할 수 있는 형상으로 개선되어야 한다. 본 연구에서 흡기계통 설계 및 사이클 해석에 활용하기 위한 기초 자료 확보를 위해 흡기밸브의 유량계수를 측정하였다. 유량계수 측정에는 정상유동장치를 이용하였다. 중속 박용기관에 사용되는 포핏 밸브를 대상으로 실험을 수행한 결과, 흡기밸브 유량계수는 밸브양정의 증가에 따라 약 0.62까지 지속적으로 증가하는 경향이며 행정/보어 비와는 무관한 흡기밸브 고유의 특성이 있음을 확인하였다.

유역모형을 이용한 비점배출계수 적용성 평가 (Evaluation of Applicability for Nonpoint Discharge Coefficient using Watershed Model)

  • 이은정;김태근
    • 환경영향평가
    • /
    • 제21권3호
    • /
    • pp.339-352
    • /
    • 2012
  • Total maximum daily load have been implemented and indicated that nonpoint discharge coeffients in flow duration curve were 0.50 of Normal flow duration ($Q_{185}$) and 0.15 of low flow duration($Q_{275}$). By using SWAT, nonpoint discharge coefficients are studied with the conditions of the instream flow and the rainfall in two study areas. The nonpoint discharge coefficient average of BOD and TP for normal flows duration in 3 years are 0.32~0.36 and 0.28~0.31. For the low flow duration, the nonpoint discharge coefficient avergae of BOD and TP were 0.10~0.12 and 0.10~0.11. These are lower than the coefficients of total maximum load regulation. There are big differences between one of regulation and one of SWAT for the normal flow duration. With the consideration of rainfall condition, the nonpoint discharge coefficient of flood flow duration are influenced on the amount of rainfalls. However, the nonpoint discharge coefficients of normal flow duration and low flow duration are not effected by the rainfall condition. Since the spatial distribution and geomorphological characteristics could be considered with SWAT, the estimation of nonpoint discharge coefficient in watershed model is better method than the use of the recommended number in the regulation.

공기유동에 대한 고온상태의 비원형 도과내에서의 열전달 및 압력강하의 측정 (Measurement of Heat Transfer and Friction Coefficients for Flow of Air in Noncircular Ducts At High Surface Temperatures.)

  • 이동렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.552-562
    • /
    • 2001
  • Measurement of average of heat transfer and friction coefficients were obtained with air flowing through electrically heated ducts having square, rectangular(aspect ration, 5), and triangular cross section for range of surface temperature from $540^{\circ}$to $1780^{\circ}$ R and Reynolds number from 1000 to 330,000. The results indicates that the effect of heat flux on correlations of the average heat transfer and friction coefficients is similar to that obtained for circular tubes in previous investigation and was nearly eliminated by evaluating the physical properties and density of the air a film temperature halfway between the average surface and fluid bulk temperatures, With the Nusselt and Reynolds numbers on the hydraulic diameter of the ducts, the data for the noncircular ducts could be represented by the same equations obtained in the previous investigation for circular tubes. Correlation of the average difference between the surface corner and midwall temperatures for the square duct was in agreement with predicted values from a previous analysis. However, for the rectangular and triangular ducts, the measured corner temperature was greater by approximately 20 and 35 percent, respectively, than the values predicted by analysis.

  • PDF

머신러닝 기법을 활용한 유황별 LOADEST 모형의 적정 회귀식 선정 연구: 낙동강 수계를 중심으로 (Study of Selection of Regression Equation for Flow-conditions using Machine-learning Method: Focusing on Nakdonggang Waterbody)

  • 김종건;박윤식;이서로;신용철;임경재;김기성
    • 한국농공학회논문집
    • /
    • 제59권4호
    • /
    • pp.97-107
    • /
    • 2017
  • This study is to determine the coefficients of regression equations and to select the optimal regression equation in the LOADEST model after classifying the whole study period into 5 flow conditions for 16 watersheds located in the Nakdonggang waterbody. The optimized coefficients of regression equations were derived using the gradient descent method as a learning method in Tensorflow which is the engine of machine-learning method. In South Korea, the variability of streamflow is relatively high, and rainfall is concentrated in summer that can significantly affect the characteristic analysis of pollutant loads. Thus, unlike the previous application of the LOADEST model (adjusting whole study period), the study period was classified into 5 flow conditions to estimate the optimized coefficients and regression equations in the LOADEST model. As shown in the results, the equation #9 which has 7 coefficients related to flow and seasonal characteristics was selected for each flow condition in the study watersheds. When compared the simulated load (SS) to observed load, the simulation showed a similar pattern to the observation for the high flow condition due to the flow parameters related to precipitation directly. On the other hand, although the simulated load showed a similar pattern to observation in several watersheds, most of study watersheds showed large differences for the low flow conditions. This is because the pollutant load during low flow conditions might be significantly affected by baseflow or point-source pollutant load. Thus, based on the results of this study, it can be found that to estimate the continuous pollutant load properly the regression equations need to be determined with proper coefficients based on various flow conditions in watersheds. Furthermore, the machine-learning method can be useful to estimate the coefficients of regression equations in the LOADEST model.

PIV에 의한 인삼세척기의 특성연구 (A Study on Flow Characteristics of a Ginseng Cleaner Using PIV)

  • 송치성
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 춘계학술대회 논문집(Proceeding of the KOSME 2000 Spring Annual Meeting)
    • /
    • pp.140-145
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry) to high_speed flow characteristics within ginseng cleaner model. Three different kinds of flow rate(15.20 27ℓ/min) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous velocity distribution time0mean velocity distribution and velocity profile are represented quantitatively for the deeper understanding of the flow characteristics in a ginseng cleaner model.

  • PDF

동심환내의 회전체 진동에 의한 부가질량, 유체감쇠계수 및 유체탄성계수에 관한 연구 (Added Mass, Viscous Damping and Fluid-stiffness Coefficients on the Rotating Inner Cylinder in Concentric Annulus)

  • 심우건;박진호;김기선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.695-701
    • /
    • 2001
  • While a rotating inner cylinder executes a periodic translational motion in concentric annulus, the vibration of the rotating inner cylinder is induced by fluid-dynamic forces acting on the cylinder. In the previous study related to journal bearing, the unsteady viscous flow in the annulus and the fluid-dynamic forces were evaluated based on a numerical approach. Considering the dynamic-characteristics of unsteady viscous flow, an approximate analytical method has been developed for estimating added mass, viscous damping and fluid-stiffness coefficients. For the study of flow-induced vibrations and related instabilities, it is of interest to separate the coefficients from the fluid-dynamic forces. The added-mass and viscous damping coefficients for very narrow annular configurations, as journal bearing. can be approximated by considering the gap ratio to the radius of inner cylinder, while the fluid-stiffness coefficient is related to the Reynolds number, the oscillatory Reynolds number and the gap ratio.

  • PDF

분무냉각에 의한 강판 열처리과정에 있어서 열전달분포의 측정 (Measurements of Heat Transfer Distribution in Spray Cooling of Hot Steel Plate .)

  • 김영찬;유갑종;서태원
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.886-893
    • /
    • 2000
  • A good understanding of the heat transfer distribution is very important to suppress the deformation of steel products. In this study, the local heat transfer coefficients are experimentally investigated to understand the heat transfer distribution of thick steel plates with even flat spray nozzle. The steel slabs are cooled down from the initial temperature of about $1000^{\circ}C$ , and the local heat transfer coefficients and surface temperatures are calculated from the measured temperature-time history. The results show that the local heat transfer coefficients of spray cooling are dominated by the local droplet flow rate, and in proportion to becoming more distant from the center of heat transfer surface, the local heat transfer coefficients decrease with the decrease of the local droplet flow rate.

  • PDF

동진지구 김제간선 내 주요 용수지선의 흐름 특성 (Flow Characteristics of Lateral Irrigation Canals Diverted from Kimje Main Canal in Dongjin Irrigation Area)

  • 최진규;손재권;김진택;김영주
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.113-121
    • /
    • 2012
  • The study was carried out to investigate the dimension of irrigation canal, and measure the water flow of those diverted from Kimje main canal in Dongjin irrigation area. The rating curves indicating the relationships between water level and discharge of the lateral canals were induced using the measured data with high regression coefficients of 0.957~0.999 at inlet points and 0.932~0.998 at end points, respectively. And Manning's roughness coefficients were estimated as the ranged from 0.015 to 0.074 at inlet points and 0.056 to 0.089 at end points with rectangular type of concrete open irrigation canals, the Manning's roughness coefficients of the end points were less than those values of the end points, which may be considered as the deposition of the bottom sediments.

Reynolds 수에 따른 꺾어진 덕트에서 열/물질전달 특성 고찰 (Effects of Reynolds Number on Flow and Heat/Mass Characteristics Inside the Wavy Duct)

  • 장인혁;황상동;조형희
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.809-820
    • /
    • 2003
  • The present study investigates effects of flow velocity on the convective heat/mass transfer characteristics in wavy ducts of a primary surface heat exchanger application. Local heat/mass transfer coefficients on the wavy duct sidewall are determined by using a naphthalene sublimation technique. The flow visualization technique is used to understand the overall flow structures inside the duct. The aspect ratio and corrugation angle of the wavy duct is fixed at 7.3 and 145$^{\circ}$ respectively, and the Reynolds numbers, based on the duct hydraulic diameter, vary from 100 to 5,000. The results show that there exist complex secondary flows and transfer processes resulting in non-uniform distributions of the heat/mass transfer coefficients on the duct side walls. At low Re (Re<1000), relatively high heat/mass transfer regions like cell shape appear on both pressure and suction side wall due to the secondary vortex flows called Taylor-Gortler vortices perpendicular to the main flow direction. However, at high Re (Re>1000), these secondary flow cells disappear and boundary layer type flow characteristics are observed on pressure side wall and high heat/mass transfer region by the flow reattachment appears on the suction side wall. The average heat/mass transfer coefficients are higher than those of the smooth circular duct due to the secondary flows inside wavy duct. And also friction factors are about two times greater than those of the smooth circular duct.