• Title/Summary/Keyword: Flow System

Search Result 14,975, Processing Time 0.049 seconds

The Lago Sofia Conglomerate : Debris Flow to Hyperconcentrated Flow Deposits in a Cretaceous Submarine Channel, Southern Chile

  • Choe, Moon-Young;Sohn, Young-Kwan;Jo, Hyung-Rae;Kim, Yea-Dong
    • Ocean and Polar Research
    • /
    • v.24 no.3
    • /
    • pp.289-300
    • /
    • 2002
  • The Lago Sofia conglomerates encased in the Cretaceous Cerro Toro Formation, southern Chile, represent a gigantic submarine channel system developed along a foredeep trough. The channel system consists of several tributaries along the trough margin and a trunk channel along the trough axis. Voluminous debris flows were generated ubiquitously along the tract of the submarine channel mainly by the failure of nearby channel banks or slopes. The flows transformed immediately into multiphase flows and resulted in very thick-bedded mass-flow deposits with a peculiar structure sequence. The mass-flow deposits commonly overlie fluted or grooved surfaces and consist of a lower division of clast-supported and imbricated pebble-cobble conglomerate with common basal inverse grading, and an upper division of clast- to matrix-supported and disorganized pebble conglomerate or pebbly mudstone with abundant intraformational clasts. The structure sequence suggests a temporal succession of a turbidity current, a bipartite hyperconcentrapted flow with active clast collisions near the flow base, and a cohesive debris flow probably with a rigid plug. The multiphase flow is interpreted to have resulted from transformation of clast-rich but cohesive debris flows. Cohesive debris flows appear to transform more easily into dilute flow types in subaqueous environments because they are apt to hydroplane. This is in contrast to the flow transitions in subaerial environments where noncohesive debris flows are dominant and difficult to hydroplane.

Development of Flow Visualization Technique for Analysis of Flow Distribution inside Dishwasher (식기세척기 내부 유동 분포 분석을 위한 유동가시화 기법 개발)

  • Kim, Ah Ran;Hahm, Jung Yoon;Cho, Jin Ho;Jo, Wisam;Ko, Han Seo
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.2
    • /
    • pp.12-17
    • /
    • 2013
  • A flow visualization technique was developed to analyze flow distribution inside a dishwasher in this study. Then, a new design plan was proposed to improve the efficiency of the dishwasher by the analyzed results and it was confirmed experimentally by the developed technique. Gas flow fields inside a drying duct of a tub for a drying process was investigated by a developed PIV (Particle Image Velocimetry) and a CFD (Computational Fluid Dynamics) method. Also, the flow visualization technique was developed for the liquid flow field of a rotor-arm system to propose the improved design idea. Also, interactions between liquid and gas were observed around the rotor-arm system. The two-phase flow was modified to the liquid flow field because laser sheets are refracted when pass through the two-phase flow. Thus, the flow visualization techniques was developed in this study to measure the instantaneous flow velocities in the liquid quantitatively.

Study of the Operation Characteristics of the Supersonic Steam Ejector System (초음속 증기 이젝터 시스템의 작동 특성에 관한 연구)

  • Kim, H.D.;Lee, J.H.;Woo, S.H.;Choi, B.G.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.329-334
    • /
    • 2001
  • In order to investigate the operating characteristics of a supersonic steam ejector, the axisymmetric, compressible, Reynolds-averaged, Navier-Stokes computations are performed using a finite volume method. The secondary and back pressures of the ejector system with a second throat are changed to investigate their effects on the suction mass flow. Three operation modes of the steam ejector system, the critical mode, subcritical mode and back flow mode, are discussed to predict the critical suction mass flow. The present computations are validated with some experimental results. The secondary and back pressures of the supersonic steam ejector significantly affect the critical suction mass flow. The present computations predict the experimented critical mass flow with fairly good accuracy. A good correlation is obtained for the critical suction mass flow. The present results show that provided the primary nozzle configuration and secondary pressure are known, we can predict the critical mass flow with good accuracy.

  • PDF

The Effect of Intake and Exhaust Pulsating Flow on the Volumetric Efficiency in a Diesel Engine (디젤기관의 흡.배기관 맥동류가 체적효율에 미치는 영향)

  • Lee, S.D.;Kang, H.Y.;Koh, D.K.;Ahn, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.11-16
    • /
    • 2006
  • The pressure fluctuation in the intake and exhaust pipe of 4 stroke-cycle diesel engine is caused by reciprocating motion of piston for suction of fresh air and exhaust of burned gas. this gas dynamic effect can be utilized for increase the volumetric efficiency. Many empirical studies have been carried out to investigate the effects of intake pulsating flow on the volumetric efficiency. However, when the gas dynamic effects are utilized for the variable speed engine to increase its performance, The speed range in which the maximum volumetric efficiency is limited and there occurs some difficulties in lay-out of intake system because it become too long. During induction process, as waves travel both directions, they are reflected and interacted each other and pressure waves are transmitted through it. Hence, the flow becomes more complex and unsteady flow. These pressure waves act upon intake pulsating flow and affects on the volumetric efficiency. In this paper the effects of pulsating flow of intake and exhaust pipes on volumetric efficiency were examined and evaluated. It was found that volumetric efficiency was affected by pulsating flow of intake and exhaust pipes.

  • PDF

A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions (흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구)

  • 박찬우;조현철;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

Numerical Simulation and Experimental Study on an Ejector System for VOC Recovery (VOC 회수를 위한 이젝터 시스템에 관한 수치모사 및 실험적 연구)

  • Kim, Hyun-Dong;Lee, Dong-Yeop;Kim, Yoon-Kee;Jeong, Won-Taek;Ahn, Joo-Ha;Kim, Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.2
    • /
    • pp.54-60
    • /
    • 2011
  • This paper is a basic study on volatile organic compounds(VOC) recovery system in a crude oil carrier. VOC is easily evaporated in cargo tankers during loading and transportation of crude oil, causes serious environmental contamination and a huge economic loss. An ejector system is designed to mix VOC gas into crude oil flow to reduce VOC concentration. Detail two-phase flow inside the ejector is simulated using a commercial CFD code. To verify the numerical prediction, a scale-down experiment is conducted. Instead of crude oil and VOC, water and air are used as the working fluids. Flow characteristics and main parameters are obtained by two-phase flow visualization and PIV measurements. Air volume flow rate induced by the ejector is compared with respect to the volume flow rate of water using experimental and numerical results. Overall performance of the two-phase ejector predicted by the CFD simulation agrees well with that of the experiment.

Analysis of Air Distribution in the Windbox System of the Utility Boiler (보일러 Windbox내 공기공급 계통의 유량분포 해석)

  • Park, Ho-Young;Kim, Sung-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.9
    • /
    • pp.581-589
    • /
    • 2008
  • The pulverized coal combustion behavior in the utility boiler is very complex since so many physical and chemical processes happen in it, simultaneously. The mixing of pulverized coal with combustion air plays an important role in achieving the efficient combustion and stable boiler operation. The distribution of combustion air supplied to the furnace through the windbox damper system has not been clearly known since the individual measurements of air flow for each air nozzle were not possible, yet. The present study describes the CFD modelling of windbox damper system and aims to obtain the air flow rates and pressure loss coefficients across the present five damper systems, respectively. The one dimensional flow network model has been also established to get air flow distributions across the windbox damper, and applied to the actual plant operation condition. Compared with the designed air flow distribution, the modelled one gives a reasonable agreement. For the actual plant operation, the predicted air flow distribution at each air nozzle is differed with the designed data and strongly affected by the individual opening angle.

Speed Control of PIG Flow in Natural Gas Pipeline (천연가스배관 내 피그흐름의 속도제어)

  • Nguyen, Tan Tien;Kim, Dong-Kyu;Rho, Yong-Woo;Kim, Sang-Bong
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.253-258
    • /
    • 2001
  • This paper introduces a simple nonlinear adaptive control method for pipeline inspection gauge (PIG) flow in natural gas pipeline. The dynamic behavior of the PIG depends on the different pressure across its body and the bypass flow through it. The system dynamics includes: dynamics of driving gas flow behind the PIG, dynamics of expelled gas in front of the PIG, and dynamics of the PIG. The method of characteristics (MOC) and Runger-Kuta method are used to solve the dynamics of flow. The PIG velocity is controlled through the amount of bypass flow across its body. A simple nonlinear adaptive controller based on the backstepping method is introduced. To derive the controller, three system parameters should be measured: the PIG position, its velocity and the velocity of bypass flow across the PIG body. The simulation has been done with a pipeline segment in the KOGAS low pressure system, Ueijungboo-Sangye line to verify the effectiveness of the proposed controller. Three cases of interest are considered: the PIG starts to move at its launcher, the PIG arrives at its receiver and the PIG restarts after stopping in the pipeline by obstruction. The simulation results show that the proposed nonlinear adaptive controller attained good performance and can be used for controlling the PIG velocity.

  • PDF

Experimental and Numerical Studies on the Flow Characteristics of a Fan-Sink (팬싱크의 유동 특성에 관한 실험 및 수치해석적 연구)

  • Lee Kyoung-Yong;Choi Young-Seok;Yun Jae-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.225-230
    • /
    • 2006
  • The overall performance and local flow fields of the fan, heat sink, and fan-sink were experimentally and numerically studied to investigate the flow characteristics of a fan-sink. The flow resistance of the heat sink was measured by small fan tester based on AMCA standards and compared with the CFD results to select available cooling fan for the fan-sink. The nonuniform velocity profile behind the fan outlet was shown by the flow visualization. The effects of nonuniform velocities on the performance of heat sink were discussed. To validate the commercial CFD code CFX-5.6, the predicted performance curve was compared with that of fan testing. The local flow fields of the fan-sink were analyzed by CFD results. MFR (multiple frame of reference) was used as a computational model combining rotating fan and stationary heat sink. Through the CFD results of the fan-sink, the flow patterns behind the fan outlet influenced the flow resistance and overall performance of the heat sink.

Impact of Bidirectional Interaction between Sewer and Surface flow on 2011 Urban Flooding in Sadang stream watershed, Korea

  • Pakdimanivong, Mary;Kim, Yeonsu;Jung, Kwansue;Li, Heng
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.397-397
    • /
    • 2015
  • The frequency of urban floods is recently increased as a consequence of climate change and haphazard development in urban area. To mitigate and prevent the flood damage, we generally utilized a numerical model to investigate the causes and risk of urban flood. Contrary to general flood inundation model simulating only the surface flow, the model needs to consider flow of the sewer network system like SWMM and ILLUDAS. However, this kind of model can not consider the interaction between the surface flow and drainage network. Therefore, we tried to evaluate the impact of bidirectional interaction between sewer and surface flow in urban flooding analysis based on simulations using the quasi-interacted model and the interacted model. As a general quasi-interacted model, SWMM5 and FLUMEN are utilized to analyze the flow of drainage network and simulate the inundation area, respectively. Then, FLO-2D is introduced to consider the interaction between the surface flow and sewer system. The two method applied to the biggest flood event occurred in July 2011 in Sadang area, South Korea. Based on the comparison with observation data, we confirmed that the model considering the interaction the sewer network and surface flow, showed a good agreement than the quasi-interacted model.

  • PDF