• Title/Summary/Keyword: Flow System

Search Result 14,975, Processing Time 0.052 seconds

Immediate effects of cigarette smoking on exercise in young adult smokers (젊은 성인 흡연자에게 흡연이 운동능에 미치는 즉시효과)

  • Park, In Won;Koh, Hyung Ki;Kang, Yoon Jung;Choi, Jae Sun;Yoo, Jee Hoon;Shin, Jong Wook;Lim, Seong-Yong;Choi, Byoung Whui;Seo, Seung Cheon;Na, Moon Jun;Hue, Sung Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.154-161
    • /
    • 1997
  • Background : Although the long term adverse effects of cigarette smoking on health are well known, the acute possible detrimental effects of smoking on pulmonary or cardiovascular function, especially when these systems are stressed by the metabolic demands of exercise, have not been well studied The purpose of this study is to determine the acute action of cigarette smoking on cardiopulmonary function under stress. Method : Twenty -one healthy smoking subjects were studied. Before exrecise testing, history taking, physical examination and baseline studies, including CBC, chest PA, PFT and EKG, were done. The subjects performed an incremental bicycle exercise test to exhaustion on two occasions, one without smoking and the other after smoking 5 cigarettes/h for 2 hours. All indices of P.F.T. and bicycle ergometry were compared between before and after smoking. Results : 1. $VO_2$max and $O_2$ pulse showed significant decrease in smoking day. 2. Although there were no significant differences, anaerobic threshold showed a tendency of decrease and HRmax showed that of increase in smoking day. 3. P.F.T. and respiratory indices showed no significant change io smoking day. Conclusion : Cigarette smoking has immediate adverse effect, especially on the cardiovascular system rather than the respiratory system. These results would be due to the effect of elevated HbCO and/or impaired blood flow in response to the exercise stimulus.

  • PDF

Immuno-stimulatory Activities of a High Molecular Weight Fraction from Cynanchum wilfordii Radix Obtained by Ultrafiltration (한외거르기(Ultrafiltration)에 의하여 분리된 백수오 고분자 분획물의 면역증진 활성)

  • Jang, Mi;Lim, Tae-Gyu;Hong, Hee-Do;Rhee, Young Kyoung;Kim, Kyung-Tack;Lee, Eunjung;Lee, Jeong Hoon;Lee, Yun Ji;Kim, Yeon Bok;Cho, Chang-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.268-274
    • /
    • 2016
  • The purpose of this study was to investigate the immuno-stimulatory activity of the high-molecular-weight fraction (HMWF) of Cynanchum wilfordii (CW) extracts obtained by ultrafiltration in murine macrophage RAW 264.7 cells and to assess its immuno-stimulatory effect in mice. Ultrafiltration was performed with polyethersulfone membranes (30 kDa cutoff) in a cross-flow filtration system to obtain the HMWF of CW. The results showed that the HMWF increased the production of various cytokines such as tumor necrosis factor-${\alpha}$, interleukin-6, and nitric oxide in dose-ependent manners. In addition, HMWF treatment increased the relative spleen weight as well as splenocyte proliferation induced by concanavalin A or bacterial lipopolysaccharide in mice. Natural killer (NK) cell activity in the HMWF-treated group was significantly increased compared to that in the control group. These results suggest that the HMWF of CW can support the immune system through secretion of macrophage cytokines, thereby enhancing NK cell activity and murine splenocyte proliferation.

Growth of Kale Seedlings Affected by the Control of Light Quality and Intensity under Smart Greenhouse Conditions with Artificial Lights (인공광 스마트온실에서 광질 및 광강도 제어가 케일 실생묘의 생장에 미치는 영향)

  • Heo, Jeong-Wook;Lee, Jae-Su;Lee, Gong-In;Kim, Hyun-Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.3
    • /
    • pp.193-200
    • /
    • 2017
  • BACKGROUND: Plant growth under smart greenhouse (that is plant factory system) conditions of an artificial light type is significantly depending on the artificial light sources such as a fluorescent lamps or Light-Emitting Diodes (LEDs) with specific spectral wavelengths regardless of the outside environmental changes. In this experiment, characteristics on the growth and compound synthesis of kale seedlings affected by light qualities and intensities provided by LEDs were mentioned. METHODS AND RESULTS: The kale seedlings which developed 3~4 true leaves were exposed by fluorescent lamps or LEDs lights of red (R), blue+white (BW), blue+red (BR) with 50 (L) or $100(H){\mu}mol/m^2/s^1$ photosynthetic photon flux (PPF) under hydroponic culture system of deep flow technique for 50 days. Shoot fresh weight increased under the RH, BWH, and BRH treatments with higher PPF. Shoot elongation of the seedlings decreased, and polyphenol synthesis promoted by the higher light intensity conditions. Sugar synthesis in the leaves was above 2 times greater under the RH treatment of monochromic red light quality with $100{\mu}mol/m^2/s^1\;PPF$ than $50{\mu}mol/m^2/s^1\;PPF$. CONCLUSION: The results show that the control of light quality and intensity in the smart greenhouse conditions with artificial lights significantly affects the growth and compound synthesis in the fresh kale leaves with higher culture efficiency compared to the conventional soil culture under greenhouse or field conditions. Researches on the optimum light intensities of the LEDs with special spectral wavelengths are necessary for maximum growth and metabolism in the seedlings.

Photosynthetic characteristics and growth analysis of Angelica gigas according to different hydroponics methods (당귀의 광합성 특성과 수경재배 방식에 따른 생장 분석)

  • Park, Jong-Seok;Kim, Sung-Jin;Kim, Hong-Ju;Choi, Jong-Myung;Lee, Gong-In
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.4
    • /
    • pp.321-326
    • /
    • 2014
  • The aim of this study was to investigate which hydroponic system is the optimum for growth and photosynthetic characteristics of Angelica gigas during experiment. Angelica gigas 'Manchu' were sowed and managed under a growth room chamber. The environmental conditions (temperature $22^{\circ}C/18^{\circ}C$ (day/night), relative humidity 50-70%, photosynthetic photon flux density (PPFD) $120{\pm}6{\mu}mol\;m^{-2}s^{-1}$) were maintained for 3 weeks. Forty eight seedlings with 4-5 leaves were transplanted in deep flow technique (DFT), substrate, and spray culture systems [culture bed: 800 (L) ${\times}$ 800 (W) ${\times}$ 400 mm(H)] under $150{\pm}5{\mu}mol\;m^{-2}s^{-1}$ PPFD provided with fluorescence lamps and cultivated for 11 weeks. At the end of the experiment, fresh and dry weights, leaf lenghth and width, SPAD, root fresh, and dry weights, and root volume of Anglica gigas were measured. Photosynthetic rate of Anglica gigas were measured with portable photosynthesis systems to investigate optimum PPFD, $CO_2$ concentration, and air temperature conditions. Fresh and dry weights of Anglica gigas grown in substrate were significantly greater than DFT-treated, but there were not significant with spray treatment. Leaf photosynthesis of Anglica gigas showed the tendency to sharply increase as PPFD was increased from 50 to $200{\mu}mol\;m^{-2}s^{-1}$. Though $CO_2$ saturation point was around $1000-1200{\mu}mol\;mol^{-1}$, increase in air temperature from 16 to $26^{\circ}C$ did not quite affect photosynthesis of Anglica gigas. In conclusion, Anglica gigas may be optimally cultivated with a spray culture system as air temperature, PPFD, and $CO_2$ concentration for environment are controlled at $20{\pm}3^{\circ}C$, $150{\mu}mol\;m^{-2}s^{-1}$, and around $1000{\mu}mol\;mol^{-1}$ for mass production.

Effect of Light-Induced ROS Generation Unit on Inactivation of Foodborne Pathogenic Bacteria in Water (광유도 ROS 발생장치의 세척용수 중 식중독 세균에 대한 불활성화 효과)

  • Choi, Jaehyuk;Kim, Dawoon;Jung, Kyu-Seok;Roh, Eunjung;Ryu, Kyoung-Yul;Ryu, Jae-Gee
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.583-590
    • /
    • 2019
  • As the consumption of fresh fruits and vegetables increases, food poisoning caused by foodborne pathogen contamination is not decreasing. To prevent the contamination of produce, a quick and easy, low-cost, environmentally-safe disinfection method that does not affect produce freshness or quality is needed. This study demonstrates a new-concept, circulating-water disinfection system that purifies water by using newly developed 'LED-PS (photosensitizer)-induced ROS generation unit'. Using various types of LED-PS induced ROS generation units, we investigated the conditions for reducing the density of various pathogenic bacteria by more than 3 log CFU / mL in 1 hour. The major operational factors affecting the density reduction of the LED-PS-induced ROS generation unit were analyzed. Depending on bacteria species, the density reduction rate was varied. The effect of the units on reducing the density of Bacillus cereus and Pectobacterium carotovorum subsp. carotovorum was high, but the effect on foodborne bacteria such as Escherichia coli was relatively low. In this circulating water disinfection system, the density reduction effect tended to increase as the flow rate increased and the initial bacterial density decreased. As the amount of PS absorbed beads increased, the density reduction effect increased exponentially in some bacteria. Model 3280, a double cylindrical unit connecting two single cylindrical units, could completely sterilize more than 3 log CFU/mL of B. cereus and P. carotovorum subsp. carotovorum in 30 minutes of LED irradiation.

A Study on Compensation for Imaging Qualities Having Artifact with the Change of the Center Frequency Adjustment and Transmission Gain Values at 1.5 Tesla MRI (1.5 Tesla 기기에서 중심주파수 조정과 송 신호강도(Transmission Gain)값 변화에 따른 인공물이 있는 자기공명영상의 질 보상에 관한 연구)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Han-Joo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.244-252
    • /
    • 2009
  • The purpose of this study is to compensate for susceptibility and a ferromagnetic body artifact using CFA and TGV on MR Imaging. A total of 30 patients (15 men and 15 women, mean age: 45 years) were performed on head and neck diseases. MR Unit used a 1.5T superconducting magnet (GE medical system, High Density). This study have investigated by changing with CFA and TGV (70, 90, 110, 130, 150) searching for compensation values about susceptibility and a ferromagnetic body artifact in 60 kg standards of body weight (p<0.05). As a quality results, Image qualities were obtained at different score from CFA and TGV (70, 90, 110, 130, $150=3.23{\pm}0.35$, $4.31{\pm}0.02$ $4.23{\pm}0.21$, $5.12{\pm}0.25$, $7.13{\pm}0.72$, $8.31{\pm}0.01$, $5.21{\pm}0.15$, $6.14{\pm}0.08$, $5.23{\pm}0.72$, $5.91{\pm}0.06$, p<0.05). Absolute CNRs (TG, CNRpre, CNRpost) were acquired with (70:$-1.44{\pm}0.11$, $-2.7{\pm}0.04$, 90:$-2.18{\pm}0.42$, $-4.41{\pm}0.43$, 110:$-2.89{\pm}0.43$, $-5.23{\pm}0.02$, 130:$-2.34{\pm}0.05$, $-5.26{\pm}0.01$, 150: $-2.09{\pm}0.08$, $-3.87{\pm}0.12$, p<0.05). In conclusions, this study could be compensated for metal and flow artifacts surrounding the tissues having artifact by changing CFA and TGV.

  • PDF

The Application of Operations Research to Librarianship : Some Research Directions (운영연구(OR)의 도서관응용 -그 몇가지 잠재적응용분야에 대하여-)

  • Choi Sung Jin
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.4
    • /
    • pp.43-71
    • /
    • 1975
  • Operations research has developed rapidly since its origins in World War II. Practitioners of O. R. have contributed to almost every aspect of government and business. More recently, a number of operations researchers have turned their attention to library and information systems, and the author believes that significant research has resulted. It is the purpose of this essay to introduce the library audience to some of these accomplishments, to present some of the author's hypotheses on the subject of library management to which he belives O. R. has great potential, and to suggest some future research directions. Some problem areas in librianship where O. R. may play a part have been discussed and are summarized below. (1) Library location. It is usually necessary to make balance between accessibility and cost In location problems. Many mathematical methods are available for identifying the optimal locations once the balance between these two criteria has been decided. The major difficulties lie in relating cost to size and in taking future change into account when discriminating possible solutions. (2) Planning new facilities. Standard approaches to using mathematical models for simple investment decisions are well established. If the problem is one of choosing the most economical way of achieving a certain objective, one may compare th althenatives by using one of the discounted cash flow techniques. In other situations it may be necessary to use of cost-benefit approach. (3) Allocating library resources. In order to allocate the resources to best advantage the librarian needs to know how the effectiveness of the services he offers depends on the way he puts his resources. The O. R. approach to the problems is to construct a model representing effectiveness as a mathematical function of levels of different inputs(e.g., numbers of people in different jobs, acquisitions of different types, physical resources). (4) Long term planning. Resource allocation problems are generally concerned with up to one and a half years ahead. The longer term certainly offers both greater freedom of action and greater uncertainty. Thus it is difficult to generalize about long term planning problems. In other fields, however, O. R. has made a significant contribution to long range planning and it is likely to have one to make in librarianship as well. (5) Public relations. It is generally accepted that actual and potential users are too ignorant both of the range of library services provided and of how to make use of them. How should services be brought to the attention of potential users? The answer seems to lie in obtaining empirical evidence by controlled experiments in which a group of libraries participated. (6) Acquisition policy. In comparing alternative policies for acquisition of materials one needs to know the implications of each service which depends on the stock. Second is the relative importance to be ascribed to each service for each class of user. By reducing the level of the first, formal models will allow the librarian to concentrate his attention upon the value judgements which will be necessary for the second. (7) Loan policy. The approach to choosing between loan policies is much the same as the previous approach. (8) Manpower planning. For large library systems one should consider constructing models which will permit the skills necessary in the future with predictions of the skills that will be available, so as to allow informed decisions. (9) Management information system for libraries. A great deal of data can be available in libraries as a by-product of all recording activities. It is particularly tempting when procedures are computerized to make summary statistics available as a management information system. The values of information to particular decisions that may have to be taken future is best assessed in terms of a model of the relevant problem. (10) Management gaming. One of the most common uses of a management game is as a means of developing staff's to take decisions. The value of such exercises depends upon the validity of the computerized model. If the model were sufficiently simple to take the form of a mathematical equation, decision-makers would probably able to learn adequately from a graph. More complex situations require simulation models. (11) Diagnostics tools. Libraries are sufficiently complex systems that it would be useful to have available simple means of telling whether performance could be regarded as satisfactory which, if it could not, would also provide pointers to what was wrong. (12) Data banks. It would appear to be worth considering establishing a bank for certain types of data. It certain items on questionnaires were to take a standard form, a greater pool of data would de available for various analysis. (13) Effectiveness measures. The meaning of a library performance measure is not readily interpreted. Each measure must itself be assessed in relation to the corresponding measures for earlier periods of time and a standard measure that may be a corresponding measure in another library, the 'norm', the 'best practice', or user expectations.

  • PDF

Quaternary Geology and Paleoecology of Hominid Occupation of Imjin Basin (임진강유역 구석기 공작의 고생태학적 배경)

  • Seonbok Yi
    • The Korean Journal of Quaternary Research
    • /
    • v.2 no.1
    • /
    • pp.25-50
    • /
    • 1988
  • The survival of rich evidence of palaeolithic occupation found in the Imjin-Hant'an River basin was possible due to many fortuitous geological conditions provided there. Formation of the basalt plain in a narrow valley system which developed during the late Mesozoic insured the appearance of a basin of sedimentation in which archaeological sites would be preserved with relatively minor post-depositional disturbance. Geomagnetic and K-Ar dating indicates that lava flows occurred during the Brunes Normal Epoch. During and after the process of basin sedimentation, erosion of the plain was confined to the major channel of the present river system which developed along the structural joints formed by the lava flow. Due to characteristic columnar structure and platy cleavage of the basalt bedrock, erosion of the basalt bedrock occurred mainly in vertical direction, developing deep but narrow entrenched valleys cut into the bedrock. Consequently, the large portion of the site area remained intact. Cultural deposits formed on top of the basalt plain were left unmodified by later fluvial disturbances due to changes in the Hant'an River base-level, since they were formed about 20 to 40m above the modern floodplain. Sedimentological evidence of cultural deposits and palynological analysis of lacustrine bed formed in the tributary basin of the Hant'an River indicate that hominid occupation occurred in this basin under rapidly deteriorating climatic conditions. From three thermoluminescence dates, the timing of hominid occupation as represented by 'Acheulian-like' bifaces apparently occur sometime during 45,000 BP. Thus, deposition of cultural layers in this basin approximately coincides with the beginning of the second stadial of the final glacial, during which the Korean Peninsula must have had provided a sanctuary for prolonged human occupation.

  • PDF

Spatial Characteristics of Pollutant Concentrations in the Streams of Shihwa Lake (시화호 유입하천의 수질오염물질 농도에 관한 연구)

  • Jang, Jeong-Ik;Han, Ihn-Sup;Kim, Kyung-Tae;Ra, Kong-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.289-299
    • /
    • 2011
  • We studied the characteristics of pollutant concentrations in 9 streams that flow into Shihwa Lake in order to provide the scientific data for effective implementation of total pollution loads management system (TPLMS) of the Lake. Suspended solid (SS), chemical oxygen demand (COD), dissolved nutrients ($NO_2$, $NO_3$, $NH_4$, $PO_4$ and $SiO_2$), total phosphorus (TP) and total nitrogen (TN) in stream water from industrial complexes, urban and agricultural regions were determined. Pollutant concentrations in December were higher than that in other sampling periods. COD concentration from industrial complex region with average of 12.6 mg/L was 2 times higher those from urban region (6.6 mg/L) and agricultural region (5.9 mg/L). TP concentration from industrial region also showed higher concentration than other regions. TN concentration in stream water was 5.89 mg/L for industrial region, 3.02 mg/L for urban region and 5.27 mg/L for agricultural region, respectively, suggesting inflow of TN due to fertilizer usage in agricultural field. Relative percentage of nitrogen compounds in TN follows the sequence: $NH_4$ (35.1%) > $NO_2$ (20.0%) > DON (22.8%) > PON (8.9%) > $NO_2$ (3.2%). Concentrations of dissolved nutrients, TP and TN in stream water were 3.2~37.2 times higher than that in Shihwa Lake seawater, therefore large amount of pollutants may be directly entered into Shihwa Lake without any treatment. For Gunja stream of industrial region, pollutants at midstream showed relatively higher concentration compared to upstream and downstream. It is necessary to manage the illegal discharging of sewage and waste water. Our results provide valuable informations on the estimation and reduction of total pollutant loads in the process of establishing adequately strategic and implemental plan of Shihwa Lake TPLMS.

Modeling and Intelligent Control for Activated Sludge Process (활성슬러지 공정을 위한 모델링과 지능제어의 적용)

  • Cheon, Seong-pyo;Kim, Bongchul;Kim, Sungshin;Kim, Chang-Won;Kim, Sanghyun;Woo, Hae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1905-1919
    • /
    • 2000
  • The main motivation of this research is to develop an intelligent control strategy for Activated Sludge Process (ASP). ASP is a complex and nonlinear dynamic system because of the characteristic of wastewater, the change in influent flow rate, weather conditions, and etc. The mathematical model of ASP also includes uncertainties which are ignored or not considered by process engineer or controller designer. The ASP is generally controlled by a PID controller that consists of fixed proportional, integral, and derivative gain values. The PID gains are adjusted by the expert who has much experience in the ASP. The ASP model based on $Matlab^{(R)}5.3/Simulink^{(R)}3.0$ is developed in this paper. The performance of the model is tested by IWA(International Water Association) and COST(European Cooperation in the field of Scientific and Technical Research) data that include steady-state results during 14 days. The advantage of the developed model is that the user can easily modify or change the controller by the help of the graphical user interface. The ASP model as a typical nonlinear system can be used to simulate and test the proposed controller for an educational purpose. Various control methods are applied to the ASP model and the control results are compared to apply the proposed intelligent control strategy to a real ASP. Three control methods are designed and tested: conventional PID controller, fuzzy logic control approach to modify setpoints, and fuzzy-PID control method. The proposed setpoints changer based on the fuzzy logic shows a better performance and robustness under disturbances. The objective function can be defined and included in the proposed control strategy to improve the effluent water quality and to reduce the operating cost in a real ASP.

  • PDF