• Title/Summary/Keyword: Flow System

Search Result 14,975, Processing Time 0.079 seconds

A study on the smoke control performance of the damper exhaust system at FCEV fire in tunnel for small vehicles (소형차 전용터널 내 수소연료전지차 화재시 집중배기방식의 제연성능에 관한 연구)

  • Hong, Seo-Hee;Baek, Doo-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.745-756
    • /
    • 2022
  • The road tunnel is a semi-closed space that is blocked on all sides except the entrance and exit, and in the event of a fire, the smoke of the fire spreads longitudinally due to heat buoyancy caused by the fire and air currents that always exist in the tunnel. To solve this problem, smoke removal facilities are installed in road tunnels to secure a safe evacuation environment by controlling the direction of movement of smoke or directly smoking at fire points. In urban areas, the service level of urban roads decreases due to the increase in traffic due to the increase in population, and as a solution, the construction of underground roads in urban areas is increasing. When a fire occurs during hydrogen leakage through TPRD of a hydrogen fuel cell vehicle (FCEV), the fire intensity depends on the amount of leakage, and the maximum fire intensity depends on the orifice diameter of the TPRD. Considering the TPRD orifice diameter of 1.8 mm, this study analyzed the diffusion distance of fire smoke according to the wind speed of the roadway and the opening interval of the large exhaust port when the maximum fire intensity was 15 MW. As a result, it was analyzed that air flow in the tunnel could be controlled if the wind speed of the road in the tunnel was less than 1.25 m/s, and smoke could be controlled within 200 m from the fire if the damper interval was 50 m and 100 m.

Usefulness of cyclic thermal therapy and red blood cell scintigraphy in patients with chemotherapy-induced peripheral neuropathy

  • Kim, Minjoo;Kim, Eun-Mi;Oh, Phil-Sun;Lim, Seok Tae;Sohn, Myung-Hee;Song, Eun-Kee;Park, Keon Uk;Kim, Jin Young;Won, Kyoung Sook;Jeong, Hwan-Jeong
    • The Korean Journal of Pain
    • /
    • v.34 no.4
    • /
    • pp.427-436
    • /
    • 2021
  • Background: Pharmacological and non-pharmacological therapies have been used to treat patients with chemotherapy-induced peripheral neuropathy (CIPN). However, the effect of therapies in cancer patients has yet to be investigated comprehensively. We hypothesized that cyclic thermal therapy would improve blood flow and microcirculation and improve the symptoms driven by CIPN. Methods: The criteria of assessment were blood volume in region of interest (ROI) in the images, and European Organization for Research and Treatment of Cancer-Quality of Life Questionnaire-Chemotherapy-Induced Peripheral Neuropathy 20 questionnaire scores. The blood volume was quantified by using red blood cell (RBC) scintigraphy. All patients were treated 10 times during 10 days. The thermal stimulations, between 15° and 41°, were repeatedly delivered to the patient's hands. Results: The total score of the questionnaires, the score of questions related to the upper limbs, the score of questions closely related to the upper limbs, and the score excluding the upper limbs questions was decreased. The blood volume was decreased, and the variance of blood volume was decreased. During cooling stimulation, the blood volume was decreased, and its variance was decreased. During warming stimulation, the blood volume was decreased, and its variance was decreased. Conclusions: We suggest that cyclic thermal therapy is useful to alleviate CIPN symptoms by blood circulation improvement. RBC scintigraphy can provide the quantitative information on blood volume under certain conditions such as stress, as well as rest, in peripheral tissue.

A Study on the Detection Model of Illegal Access to Large-scale Service Networks using Netflow (Netflow를 활용한 대규모 서비스망 불법 접속 추적 모델 연구)

  • Lee, Taek-Hyun;Park, WonHyung;Kook, Kwang-Ho
    • Convergence Security Journal
    • /
    • v.21 no.2
    • /
    • pp.11-18
    • /
    • 2021
  • To protect tangible and intangible assets, most of the companies are conducting information protection monitoring by using various security equipment in the IT service network. As the security equipment that needs to be protected increases in the process of upgrading and expanding the service network, it is difficult to monitor the possible exposure to the attack for the entire service network. As a countermeasure to this, various studies have been conducted to detect external attacks and illegal communication of equipment, but studies on effective monitoring of the open service ports and construction of illegal communication monitoring system for large-scale service networks are insufficient. In this study, we propose a framework that can monitor information leakage and illegal communication attempts in a wide range of service networks without large-scale investment by analyzing 'Netflow statistical information' of backbone network equipment, which is the gateway to the entire data flow of the IT service network. By using machine learning algorithms to the Netfllow data, we could obtain the high classification accuracy of 94% in identifying whether the Telnet service port of operating equipment is open or not, and we could track the illegal communication of the damaged equipment by using the illegal communication history of the damaged equipment.

Measurements and Calculation of Injection Mass Rate of LFG for Intake Injection in Spark Ignition Engines (불꽃점화 엔진의 흡기관 분사를 위한 매립지가스 분사량의 측정 및 계산)

  • Kim, Kyoungsu;Choi, Kyungho;Jeon, Wonil;Kim, Bada;Lee, Daeyup
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.4
    • /
    • pp.36-42
    • /
    • 2021
  • When the landfill gas generated at the landfill site is released into the atmosphere, methane gas with a high global warming potential is emitted, which adversely affects climate change. When methane contained in landfill gas is used as fuel for internal combustion engines and burned to generate electricity, it is emitted into the atmosphere in the form of carbon dioxide, which can contribute to lowering the global warming potential. Therefore, in order to use the landfill gas as fuel for power generation using an internal combustion engine, it is important to increase the thermal efficiency of the engine. Thus, it is necessary to use a fuel supply system in which gas is injected using an electronically controlled injector at an intake port for each cylinder rather than a fuel supply technology using the conventional mixer technology. In order to use the electronically controlled gas injection method, it is important to accurately measure the mass flow rate according to the conditions of using landfill gas. For this, a study was conducted to measure the injection amount and calculate them in order for the intake port gas injection of landfill gas.

BigData Research in Information Systems : Focusing on Journal Articles about Information Systems (정보시스템 분야의 빅데이터 연구 흐름 분석 : Information Systems 관련 저널을 중심으로)

  • Park, Kyungbo;Kim, Juyeong;Kim, Han-Min
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.681-689
    • /
    • 2019
  • The 46th Davos Forum of the World Economic Forum (WEF) predicts the continued growth of the 4th industry in the future. Currently, the 4th industry is attracting attention in various academic and practical fields. As a core technology of the 4th industry, Big Data is regarded as a major resource to lead the 4th industrial revolution along with artificial intelligence. As the growing interest in Big Data, researches on it are actively being done. However, literature studies on existing Big Data are focused on qualitative research, and quantitative research is insufficient. Therefore, this study aims to analyze the big data research flow in MIS field and to make academic thirst for quantification. This study has collected 145 abstracts of big data papers published in major journals in MIS field and confirmed that a majority of papers are published in Decision Support Systems Journal. Text mining and text network analysis were performed only for DSS journals to eliminate bias. As a result of the analysis, it was found out that researches on combining big data in the management field between 2012 and 2014, and researches on system development and analysis method for using big data from 2015 to 2017 were conducted.

Life Cycle Assessment on Process of Wet Tissue Production (물티슈 제조공정의 전과정 평가)

  • Ahn, Joong Woo
    • Clean Technology
    • /
    • v.24 no.4
    • /
    • pp.269-274
    • /
    • 2018
  • In this study, Life Cycle Assessment (LCA) of wet tissue manufacturing process was performed. The wet tissue manufacturing process consists of preparation of wetting agent (chemical liquid), impregnation of nonwoven fabric into wetting agent and primary and secondary packaging. Data and information were collected on the input and output of the actual process from a certain company and the database of the Korea Ministry of Environment and some foreign countries (when Korean unavailable) were employed to connect the upper and the lower process flow. Based on the above and the potential environmental impacts of the wet tissue manufacturing process were calculated. As a result of the characterization, Ozone Layer Depletion (OD) is 3.46.E-06 kg $CFC_{11}$, Acidification (AD) is 5.11.E-01 kg $SO_2$, Abiotic Resource Depletion (ARD) is $3.52.E+00\;1yr^{-1}$, Global Warming (GW) is 1.04.E+02 kg $CO_2$, Eutrophication (EUT) is 2.31.E-02 kg ${PO_4}^{3-}$, Photochemical Oxide Creation (POC) was 2.22.E-02 kg $C_2H_4$, Human Toxicity (HT) was 1.55.E+00 kg 1,4 DCB and Terrestrial Ecotoxicity (ET) was 5.82.E-04 kg 1,4 DCB. In order to reduce the environmental impact of the manufacturing process, it is necessary to improve the overall process as other general cases and change the raw materials including packaging materials with less environmental impact. Conclusively, the energy consumed in the manufacturing process has emerged as a major issue, and this needs to be reconsidered other options such as alternative energy. Therefore, it is recommended that a process system should be redesigned to improve energy efficiency and to change to an energy source with lower environmental impact. Due to the nature of LCA, the final results of this study can be varied to some extent depending on the type of LCI DB employed and may not represent of all wet tissue manufacturing processes in the current industry.

Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse (플라스틱 단동온실의 천창 종류에 따른 자연환기 효과)

  • Rasheed, Adnan;Lee, Jong Won;Kim, Hyeon Tae;Lee, Hyun Woo
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.225-233
    • /
    • 2019
  • In the summer season, natural ventilation is commonly used to reduce the inside air temperature of greenhouse when it rises above the optimal level. The greenhouse shape, vent design, and position play a critical role in the effectiveness of natural ventilation. In this study, computational fluid dynamics (CFD) was employed to investigate the effect of different roof vent designs along with side vents on the buoyancy-driven natural ventilation. The boussinesq hypothesis was used to simulate the buoyancy effect to the whole computational domain. RNG K-epsilon turbulence model was utilized, and a discrete originates (DO) radiation model was used with solar ray tracing to simulate the effect of solar radiation. The CFD model was validated using the experimentally obtained greenhouse internal temperature, and the experimental and computed results agreed well. Furthermore, this model was adopted to compare the internal greenhouse air temperature and ventilation rate for seven different roof vent designs. The results revealed that the inside-to-outside air temperature differences of the greenhouse varied from 3.2 to $9.6^{\circ}C$ depending on the different studied roof vent types. Moreover, the ventilation rate was within the range from 0.33 to $0.49min^{-1}$. Our findings show that the conical type roof ventilation has minimum inside-to-outside air temperature difference of $3.2^{\circ}C$ and a maximum ventilation rate of $0.49min^{-1}$.

Evaluation of thermal stress of poultry according to stocking densities using mumerical BES model (BES 수치모델을 이용한 사육 밀도별 가금류 고온 스트레스 평가)

  • Kwon, Kyeong-seok;Ha, Tahwan;Choi, Hee-chul;Kim, Jong-bok;Lee, Jun-yeob;Jeon, Jung-hwan;Yang, Ka-young;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sang-yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.456-463
    • /
    • 2019
  • Micro climatic conditions within the livestock facility are affected by various factors such as ventilation, cooling, heating, insulation and latent and sensible heat generation from animals. In this study, numerical BES method was used to simulate energy flow inside the poultry house. Based on the BES method and THI concept, degree of thermal stress of poultry was evaluated according to the locations in South Korea. Comparison of THI values within the poultry house was also carried out according to the stocking densities to reflect recent animal-welfare issue. Significant decrease in thermal stress of poultry was observed when the stocking density of $30kg/m^2$ was applied in the change of the seasons(p<0.05) however, there was no statistically significant difference in summer season(p>0.05). It meant that installation of proper cooling system is urgently needed. For Iksan city of Jeollabuk-do province, total 252 hours of profit for thermal stress was found according to decrease in the stocking density.

Comparison of the CO2 Emission Estimation Methods in a LNG Power Plant Based on the Mass Balance Approach (물질수지 방법을 고려한 액화천연가스 발전소에서의 온실기체 배출량 산정 방법 비교)

  • Kim, Hee-Jin;Yeo, Min Ju;Kim, Yong Pyo;Jang, Geon Woo;Shin, Won Geun;Lee, Myung Hwoon;Choi, Hyung Wook
    • Journal of Climate Change Research
    • /
    • v.4 no.3
    • /
    • pp.235-244
    • /
    • 2013
  • Carbon dioxide emission estimation methods consist of four tiers according to the IPCC guideline. In this study, estimated results by tier 3 and tier 4 were compared with the theoretically calculated $CO_2$ emissions based on the mass balance approach for a gas fired power plant between March and May 2011. It was found that the relative differences were upto 17% between the measured emissions by tier 4 and theoretically estimated emissions, while the results of tier 3 were similar to those from theoretically estimated ones. The comparisons suggested the possibility of misestimation due to replacing missing, abnormal, or invalid data in continuous emissions monitoring system. When using only the data without those missing, abnormal, or invalid data, the relative differences decreased somewhat but still showed consistent differences depending on the stack. It is suggested that this differences might be due to the accuracy of the measurement instruments for the tier 4, especially, for the flow rate measurement instrument.

Pharmacokinetics and Pharmacodynamics Following Oral Administration of Pimobendan-Pentoxifylline Powder Formulation Mixture in Dogs (개에서 피모벤단-펜톡시필린 분말 제형 합제의 경구투여시 약물약동학 및 약물약력학에 대한 연구)

  • Ro, Woong-bin;Song, Doo-won;Kang, Yeo-lim;Park, You-jin;Yoo, Cho-rong;Lee, Jong-ho;Kim, Ki-hun;Jeong, Sang-hee;Kang, Min-hee
    • Journal of Veterinary Clinics
    • /
    • v.36 no.1
    • /
    • pp.46-52
    • /
    • 2019
  • Pimobendan has inotropic and vasodilating effects on cardiovascular system, and pentoxifylline is known to decrease blood viscosity and improve blood flow to the heart. This study investigated the pharmacokinetics and pharmacodynamics following oral administration of pimobendan-pentoxifylline powder mixture in dogs. Eight healthy dogs were included and were divided into control (n = 4) and experimental (n = 4) groups. Vehicle powder and pimobendan-pentoxifylline powder mixture (pimobendane 0.25 mg/kg, pentoxifylline 15 mg/kg) were administrated orally to control and experimental groups, respectively. Plasma samples and measurement of echocardiographic indices were obtained for 24 hours following administration. Pimobendan and pentoxifylline concentrations were investigated using liquid chromatography-mass spectrometer (LC-MS) assay. The elimination half-life ($T_{1/2}$) were $2.65{\pm}1.42hours$ for pimobendan and $0.29{\pm}0.23hours$ for pentoxifylline. The time to reach maximum concentration ($T_{max}$) were $1.08{\pm}0.72hours$ for pimobendan and $0.29{\pm}0.14hours$ for pentoxifylline. The maximum blood concentration ($C_{max}$) were $2.83{\pm}1.50ng/mL$ for pimobendan and $1184.33{\pm}932.37ng/mL$ for pentoxifylline. Among echocardiographic indices, fractional shortening (FS), left ventricular internal diameter at end systole (LVIDs), and pre-ejection period (PEP) showed significant changes at 1-4 hours after the administration of pimobendan-pentoxifylline powder mixture. No adverse effects were observed during the investigation. This study demonstrates that pimobendan-pentoxifylline powder mixture can be used to control cardiovascular diseases in dogs.