• 제목/요약/키워드: Flow System

검색결과 14,894건 처리시간 0.04초

PID 제어기를 이용한 좌심실보조장치의 제어 (PID control of left ventricular assist device)

  • 정성택;김훈모;김상현
    • 제어로봇시스템학회논문지
    • /
    • 제4권3호
    • /
    • pp.315-320
    • /
    • 1998
  • In this paper, we present the PID control method for the controlling flow rate of highly complicated nonlinear Left Ventricular Assist Device(LVAD) with pneumatically driven mock circulatory system. Beat Rate (BR), Systole-Diastole Rate (SDR) and flow rate are used as the main variables of the LVAD system. System modeling is completed using the neural network with input variables (BR, SDR, their derivatives, actual flow) and an output valiable(actual flow). Then, as the basis of this model, we perform the simulation of PID control to predict the performance and tendency of the system and control the flow rate of LVAD system using the PID controller. The ability and effectiveness of identifying and controlling a LVAD system using the proposed algorithm will be demonstrated through computer simulation and experiments.

  • PDF

연속조류계산 시스템의 개발 (The Development of a Continuation Power Flow System)

  • 송화창;이병준;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.894-896
    • /
    • 1997
  • This paper presents the continuation power flow system that is under development. The continuation power flow system provides robust solutions of power flow equations at any operating point. The robust convergency enables one to find solutions even at the point where power flow jacobian becomes singular. Basic concept of an algorithm and its application to static voltage stability analysis are presented.

  • PDF

삼차원 재구성을 위한 Data-Flow 기반의 프레임워크 (A data-flow oriented framework for video-based 3D reconstruction)

  • 김희관
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2009년도 춘계학술발표대회
    • /
    • pp.71-74
    • /
    • 2009
  • The data-flow paradigm has been employed in various application areas. It is particularly useful where large data-streams must be processed, for example in video and audio processing, or for scientific visualization. A video-based 3D reconstruction system should process multiple synchronized video streams. The system exhibits many properties that can be targeted using a data-flow approach that is naturally divided into a sequence of processing tasks. In this paper we introduce our concept to apply the data-flow approach to a multi-video 3D reconstruction system.

CDMA기반 전자부자 흐름 패턴 시스템 설계 및 구현 (A Design and Implementation of CDMA based Electronic Float Flow Pattern System)

  • 김동현;이채석;김종덕
    • 한국정보통신학회논문지
    • /
    • 제16권12호
    • /
    • pp.2619-2627
    • /
    • 2012
  • 전자 부자 흐름 패턴 시스템은 위치 측위 기술과 여러 가지 통신 기술을 이용하여 원격에서 부자의 위치를 모니터링 함으로써 하천의 유량을 예측할 수 있다. 현재 자연하천의 흐름 패턴을 분석하기 위해 여러 형태의 수동 부자들이 사용되고 있다. 수동 부자를 이용한 유량 측정은 유량을 측정하기위해 거리와 시간을 직접 측정한 후 이것을 이용한다. 이러한 방법은 측정방법과 정확한 유량 측정 측면에서 효율적이지 못하다. 이러한 문제를 극복하기 위해 본 연구진은 CDMA, GPS 그리고 2.4GHz기반의 RF모듈을 이용하여 전자부자를 설계 및 구현했다. 그리고 전자부자의 위치정보와 흐름 패턴 정보를 알기 위한 모니터링 시스템을 설계 및 구현하였다. 더불어 배터리로 동작하는 전자부자에서 짧은 life cycle은 전자부자를 이용한 흐름 패턴 시스템에서의 효용성을 떨어뜨린다. 이를 극복하기 위해 전자부자 흐름 패턴 시스템의 전자부자를 위한 전원 절약 기법을 설계하였다.

하이브리드/전기 자동차 배터리 냉각 시스템의 냉각수 유동 특성이 냉각 성능에 미치는 영향에 대한 해석적 연구 (Effect of Coolant Flow Characteristics in Cooling Plates on the Performance of HEV/EV Battery Cooling Systems)

  • 오현종;박성진
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.179-185
    • /
    • 2014
  • Average temperature and temperature uniformity in a battery cell are the important criteria of the thermal management of the battery pack for hybrid electric vehicles and electric vehicles (HEVs and EVs) because high power with large size cell is used for the battery pack. Thus, liquid cooling system is generally applied for the HEV/EV battery pack. The liquid cooling system is made of multiple cooling plates with coolant flow paths. The cooling plates are inserted between the battery cells to reject the heat from batteries to coolant. In this study, the cooling plate with U-shaped coolant flow paths is considered to evaluate the effects of coolant flow condition on the cooling performance of the system. The counter flow and parallel flow set up is compared and the effect of flow rate is evaluated using CFD tool (FLUENT). The number of counter-flows and flow rate are changed and the effect on the cooling performance including average temperature, differential temperature, and standard deviation of temperature are investigated. The results show that the parallel flow has better cooling performance compared with counter flow and it is also found that the coolant flow rate should be chosen with the consideration of trade-off between the cooling performance and pressure drop.

The Influence of Opposing Flow and Its Separation of SBF over Masan on Southeast Coast of the Korea

  • Ji, Hyo-Eun;Lee, Kwi-Ok;Lee, Soon-Hwan;Park, Soon-Young;Jeon, Won-Bae;Lee, Hwa-Woon
    • Asian Journal of Atmospheric Environment
    • /
    • 제5권4호
    • /
    • pp.216-227
    • /
    • 2011
  • A Sea breeze front (SBF) appears clear particularly if there is opposing wind, and the convergence zone along a SBF affects air quality in coastal areas. This study analyzes features of SBF separation in the presence of an opposing flow in the southeastern coastal area of Korea Peninsula. Using a Regional Atmospheric Modeling System (RAMS) numerical simulation and an opposing flow, two types of SBF were observed at Masan coastal area of Korea. In one, the SBF penetrated inland despite of the opposing flow at Jinhae (1100 LST), Wondong (1700 LST), Saenglim (1700 LST), and Miryang (1700 LST). In the other, the SBF remained on the coastline along with Jinhae (1100 LST), Masan (1400 LST), Jinbuk (1400 LST), and Gaecheon (1700 LST), because the inflow of the sea breeze was not sufficient to penetrate inland against the opposing flow. This study shows that SBFs are affected by the formation of an opposing flow, as well as the inflows of a sea breeze and the opposing flow.

5MW 연구용 원자로의 1차 냉각 계통 유동 특성 (Flow Characteristics of a Primary Cooling System in 5 MW Research Reactor)

  • 박용철;이용섭
    • 한국유체기계학회 논문집
    • /
    • 제13권5호
    • /
    • pp.5-10
    • /
    • 2010
  • 5MW, open pool type research reactor, is commonly used to education and experimental purpose. It is necessary to prepare a standardization of system designs for considering a demand. HANARO has prepared the standardization of 5MW research reactor system designs based on the design, installation, commissioning and operating experiences of HANARO. For maintaining an open pool type reactor safety, a primary cooling system (after below, PCS) should remove the heat generated by the reactor under a reactor normal operation condition and a reactor shutdown condition. For removing the heat generated by the reactor, the PCS should maintain a required coolant flow rate. For a verification of the required flow rate, a flow network analysis of the PCS was carried under a normal operating condition. Based on the flow network analysis result, this paper describes the PCS flow characteristics of a 5MW open pool type research reactor. Through the result, it was confirmed that the PCS met design requirements including design flow rate without cavitation.

경질유 유량표준장치의 신뢰도 검증을 위한 측정정확도 비교 (Intercomparison of Light Oil Flow Standard System for the Reliability of Measurement Accuracy)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제32권9호
    • /
    • pp.712-719
    • /
    • 2008
  • Light Oil Flow Standard System(LOFSS), as a national oil flow standard system, in Korea Research Institute of Standards and Science(KRISS) was developed for oil flowmeter calibration, and the expanded uncertainty of flow quantity determination was estimated within 0.04 %. In order to improve the reliability of the LOFSS measurement, a proficiency test was carried out in the flow range of 20 and $240\;m^3/h$ (Reynolds number $20,000{\sim}900,000$). A turbine flowmeter was used as a transfer package in round robin test. The water flow standard system of KRISS, the pipe prover of the national calibration and test organization and the master meter calibrator of the turbine flowmeter supplier, which used the different working fluid respectively, were compared with the turbine flowmeter measurement. The maximum difference of measurement was 0.15 % between the LOFSS and the pipe prover. The En numbers of the each system measurement were evaluated at the same Reynolds number. It was found that the En numbers were less than 1 in the comparison, which means the procedures of the uncertainty estimation of the each calibrators were reasonable and reliable.

피스톤 냉각용 엔진오일 제트 유동특성 (Flow Characteristics of Oil Jet for Cooling a Piston)

  • 리리;이종훈;정호윤;김재환;이연원
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.50-55
    • /
    • 2006
  • An efficient cooling system for a piston of an automotive engine is very important. Therefore a large capacity gasoline engine or diesel engine has adopted the direct injection cooling system to increase its cooling efficiency. In this direct cooling system, an cooling oil is injected to a piston directly using an oil jet and this cooling oil flows through an oil gallery inside the piston. Flow rate and injection accuracy of this cooling oil are very important because these are main factors that have influence on its efficiency. The purpose of this study is to understand the changes of flow characteristics with various curvatures and diameters of an outlet nozzle and to check whether engine oil enters into the oil gallery well or not. From this study, we found that secondary flow was formed in a curved part of jet due to centrifugal force and irregular flow pattern appeared at the jet outlet. This pattern has influence on flow characteristics of engine oil entering the gallery. These simulation results have a good agreement with experiments.

  • PDF

Utilizing OpenFlow and sFlow to Detect and Mitigate SYN Flooding Attack

  • Nugraha, Muhammad;Paramita, Isyana;Musa, Ardiansyah;Choi, Deokjai;Cho, Buseung
    • 한국멀티미디어학회논문지
    • /
    • 제17권8호
    • /
    • pp.988-994
    • /
    • 2014
  • Software Defined Network (SDN) is a new technology in computer network area which enables user to centralize control plane. The security issue is important in computer network to protect system from attackers. SYN flooding attack is one of Distributed Denial of Service attack methods which are popular to degrade availability of targeted service on Internet. There are many methods to protect system from attackers, i.e. firewall and IDS. Even though firewall is designed to protect network system, but it cannot mitigate DDoS attack well because it is not designed to do so. To improve performance of DDOS mitigation we utilize another mechanism by using SDN technology such as OpenFlow and sFlow. The methodology of sFlow to detect attacker is by capturing and sum cumulative traffic from each agent to send to sFlow collector to analyze. When sFlow collector detect some traffics as attacker, OpenFlow controller will modify the rule in OpenFlow table to mitigate attacks by blocking attack traffic. Hence, by combining sum cumulative traffic use sFlow and blocking traffic use OpenFlow we can detect and mitigate SYN flooding attack quickly and cheaply.