• Title/Summary/Keyword: Flow System

Search Result 14,894, Processing Time 0.037 seconds

The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility (하나로 유동모의 설비의 유체순환계통 해석)

  • Park, Yong-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

The Analysis for Flow Circulation System in HANARO Flow Simulation Facility (하나로 유동 모의 설비의 유체순환계통 해석)

  • Park, Yong-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.1 s.22
    • /
    • pp.30-35
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. HANARO flow simulation facility is being developed for the endurance test of reactivity control units for extended life time and the verification of structural integrity of those experimental equipments prior to loading in the HANARO. This facility is composed of three major parts; a half-core structure assembly, a flow circulation system and a support system. The flow circulation system is composed of a circulation pump, a core flow piping, a core bypass flow piping and instruments. The system is to be filled with de-mineralized water and the flow should be met the design requirements to simulate a similar flow characteristics in the core channel of the half-core structure assembly to the HANARO. This paper, therefore, presents an analytical analysis to study the flow behavior of the system. Computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with the standard $k-{\epsilon}$ turbulence model and for the verification of the structural piping integrity through the finite element method. According to the analysis results, it could be said that the design requirements and the structural piping integrity of the flow circulation system are satisfied.

The Development of New GO-FLOW Methodology Using the Reliability of System Components (시스템 구성요소의 신뢰도를 기반으로 하는 새로운 GO-FLOW기법 개발)

  • Byun, Yoon-Sup;Lee, Ju-Yeong;Hwang, Kyu-Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.8-15
    • /
    • 2012
  • The GO-FLOW methodology is capable of assessing system reliability. It models the system into a GO-FLOW chart with signal lines and operators and assesses the reliability of system by assessing the GO-FLOW chart sequential. But, as it models one component of system into several operators, the GO-FLOW chart which is different from the system flow diagram be modeled. Also, as it models the real operation time into "time point", it is hard to assess the reliability change according to the real operation time. Therefore, in this paper, the new GO-FLOW methodology which use the function(success/failure) of system components has been developed. It can assess the successful operating probability of system, regardless of the operating status of components. As it models one component of system into one operator, the GO-FLOW chart which is similar the system flow diagram can be modeled. Also, it is able to easily assess the successful probability of system according to the real operation time using the time in the operators.

Effect of Venturi System on Acceleration of Low-speed Water Flow at the Venturi Throat Installed at the Inlet of Hydro Turbine

  • Jung, Sang-Hoon;Seo, In-Ho;Kim, Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.7
    • /
    • pp.914-920
    • /
    • 2011
  • For a hydro turbine electricity generation system in river or bay, a venturi system could be applied to accelerate flow speed at the inlet of the turbine system in a flow field. In this study, a steady flow simulation was conducted to understand the effect of venturi system on the acceleration of current speed at the inlet of a hydro turbine system. According to the continuity equation, the flow speed is inversely proportional to the cross-section area in a conduit flow; however, it would be different in an open region because the venturi system would be an obstruction in the flow region. As the throat area is 1/5 of the inlet area of the venturi, the flow velocity is accelerated up to 2.1 times of the inlet velocity. It is understood that the venturi system placed in an open flow region gives resistance to the upcoming flow and disperses the flow energy around the venturi system. The result of the study should be very important information for an optimum design of a hydro turbine electricity generation system.

Development of a Gas Flow Measurement and Control System (가스 유량 계측 및 제어 시스템 연구)

  • 전학진;양종화
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.255-259
    • /
    • 1996
  • This paper describes a system for measurement and control of a gas flow. In order to measure the flux of gas and control a vavle according to flux, this system was developed. This system is implemented on the personal computer and its environment is developed tool called TMS. This system includes a main program and Tele-Metering Unit for transmitting correcting flow value based on temperature and pressure in flow computer and AD converter for transmitting instantaneous flow rate, temperature and pressure as interface part of personal computer. This system was made by Visual C++ program. Using this system, inspected data for the recognition of transmitting flow value are generated on the screen, file and printer. The activity, reliability of this system was verified on Daegu-Citygas that aids the system for the acquisition of inspected data by realtime application.

  • PDF

A Study on the Effects of Flow Adaptive Gating System and Ceramic Filter on Flow Stability (흐름 적응 탕구계와 필터가 유동 안정성에 미치는 영향 연구)

  • Hwang, Ho-Young;Yin, Song;Nam, Cheol-Hee
    • Journal of Korea Foundry Society
    • /
    • v.37 no.3
    • /
    • pp.71-77
    • /
    • 2017
  • Casting defects produced during the casting process seriously affect the mechanical properties of the resulting products, reduce the performance capabilities of the product, and also result in economic losses. Therefore, this paper mainly investigates the causes of defects and methods by which to reduce these defects stemming from molten metal flows in a runner system of the type widely used in the sand mold casting process. The flow characteristics of a molten alloy are difficult to observe during the actual casting process. For this reason, a water model was used to observe the flow in the casting process, and the flow in each case was recorded using high-speed cameras as part of the experimental process of this study. Several repetitive experiments were performed to improve the accuracy of the experimental results. The traditional casting system was modified according to the design rules proposed by Campbell, and the system was termed flow-adaptive gating system with a water model. Comparing the flow characteristics of traditional and adaptive gating systems with a water model shows that the bubbles in the water in the latter case are reduced more significantly than in the former case. A ceramic filter system was adapted to the flow-adaptive gating system to minimize the instability of the flow during filling, which occurs as the fluid velocity in the runner increases. In additional, the flow behavior with and without the filter system were compared. The water model system in this work was shown to be able to verify that the adaptation of the filter system brings improvements by stabilizing the flow and reducing the amount of bubbles in the runner system. Moreover, using the flow-adaptive runner system with the filter system leads to considerably stable flows in the runner system.

Analysis of Flow Characteristics in the Intake System of 6-Cylinder MPI CNG Engine

  • Ha, Seung-Hyun;Kim, Ho-Young;Chung, Jin-Taek
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.215-222
    • /
    • 2002
  • It has been well acknowledged that intake system plays great role in the performance of reciprocating engine. Well-designed intake system is expected to not only increase engine efficiency but also decrease engine emission, which is one of the most urgent issues in the automotive society. Thorough understanding of the flow in intake system helps great to design adequate intake system. Even though both experimental and numerical methods are used to study intake flow, numerical analysis is more widely used due to its merits in time and economy. Intake system of In-line 6-Cylinder CNG engine was chosen for the analysis ICEM CFD HEXA was used to create 3-D structured grid and FIRE code was used for the flow analysis in the intake system. Due to the complexity of the geometry standard ${\kappa}-{\varepsilon}$ turbulence model was applied. Numerical analysis was performed for various inlet and outlet boundary conditions under both steady and transient flow. Inlet mass flow rate and outlet pressure variation were changing parameters with respect to engine speed. Flow parameters, such as velocity, pressure and flow distribution, were evaluated to provide adequate data of this intake system.

  • PDF

Experiment investigation on flow characteristics of open natural circulation system

  • Qi, Xiangjie;Zhao, Zichen;Ai, Peng;Chen, Peng;Sun, Zhongning;Meng, Zhaoming
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1851-1859
    • /
    • 2022
  • Experimental research on flow characteristics of open natural circulation system was performed, to figure out the mechanism of the open natural circulation behaviors. The influence factors, such as the heating power, the inlet subcooled and the level of cooling tank on the flow characteristics of the system were examined. It was shown that within the scope of the experimental conditions, there are five flow types: single-phase stable flow, flash and geyser coexisting unstable flow, flash stable flow, flash unstable flow, and flash and boiling coexisting unstable flow. The geyser flow in flash and geyser coexisting unstable flow is different from classic geysers flow. The flow oscillation period and amplitude of the former are more regular, is a newly discovered flow pattern. By drawing the flow instability boundary diagram and sorting out the flow types, it is found that the two-phase unstable flow is mainly characterized by boiling and flash, which determine the behavior of open natural circulation respectively or jointly. Moreover, compared with full liquid level system, non-full liquid level system is more prone to boiling phenomenon, and the range of heat flux density and undercooling degree corresponding to unstable flow is larger.

Design and Implementation of a Mail Browser that can control Data-Flow on the Web (Web에서 데이터 흐름제어가 가능한 Mail Browser의 설계 및 구현)

  • Park, Gyu-Seok;Kim, Seong-Hu
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.10
    • /
    • pp.2752-2763
    • /
    • 1999
  • On account of the text based mail system has it's limit to support multimedia applications, GUI based mail system platform was developed to control document flow and automatize information process. The existing mail systems's to transmit data must need additional functions to automate document flow control. The platform of document flow control is deeply related to EDMAS(Electronic document Management System), workflow, Electronic Banking, DMS(Document Management System) automation, so it needs an ability to control proper data and document correctly. To resolve this problems, we are need of browser and engine to design work flow and to control documents flow. In this paper, we develope a mail browser to design document flow by follow user's requirements. This system can generate executive script code for document flow, and we add the function of workflow and process management to automatize the document flow in this system, and then we implement this Data flow engine.

  • PDF

Analysis of Flow Characteristics of Triple Filter System by the Influence of Filter Density (필터 조밀도의 영향에 의한 3단 필터 시스템의 유동특성 해석)

  • In-Soo Son
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1163-1169
    • /
    • 2023
  • In this study, the flow characteristics of the filter system were analyzed due to the effect of the density of the filter in the triple filter system. Flow analysis was performed as a flow passing through a porous medium. The flow characteristics of each filter system were analyzed by arranging filters with different densities in the forward flow flow and the reverse flow. The arrangement order of the triple filters was excellent in the case of forward fluid flow and in the case of higher density from the inside to the outside filter. In the reverse flow filter system, the performance of the system was the best in the case of reverse order filter arrangement. As a result of the analysis, Case II, which showed a pressure drop rate of 5.65% for forward flow, was the best in the reverse direction with a pressure drop rate of 14.25%. Considering reverse and forward flows, it was found that the optimal filter arrangement was most effective when the intermediate filter was the densest, and the inner or outer filter was less dense.