• Title/Summary/Keyword: Flow Speed Measurement

Search Result 348, Processing Time 0.031 seconds

Effect of the Pressure and the Flow Pattern in a Sac Chamber of a Diesel Injection Nozzle on the Issued Spray Behaviors (디젤 연료분사노즐 색크실내의 압력과 유동패턴이 분류의 분열거동에 미치는 영향)

  • 김장헌;송규근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • The effects of the internal flow in a diesel injection nozzle on the atomization of the spray has been investigated experimentally. Flow visualization was made using a transparent acrylic model nozzle. And also, measurement of the sac chamber pressure was made for clartfying the effect of pressure fluctuation in the sac chamber on the wpray behaviors. The geometry of the model nozzle was scaled up 10 times of the actual nozzle and the injection pressure for the model nozzle was adjusted so as to achieve a Reynolds number at the discharge hole which was the same as the actual nozzle. Polystyrene tracers, a laser sheet light and a still/high speed video camera were used to visualize the flow pattern in the sac chamber. When the needle lift was small, the high turbulence in the sac chamber generated by the high velocity seat flow made the spread angle of the spray large. Cavitation which arose in the sky chamber induced the pressure fluctuation and then affects the spread angle of the spray.

  • PDF

Design and Evaluation of Blood flow Measurement Using Self-mixing type Semiconductor Laser (자기혼합형 반도체 레이저를 이용한 혈류측정 시스템 설계 및 평가)

  • Kim, Duck-Young;Lee, Jin;Kim, Se-Dong;Ko, Han-Woo;Kim, Sung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.499-506
    • /
    • 1996
  • Blood flow velocimeter is an essential device to measure the blood flow in skin tissue. In this study, we developed a high-speed LDV(laser Doppler Velocimeter) that has real time processing capability using a DSP(digital signal processing) chip and is able to continuously measure information about blood-flow based on a noninvasive method using self-mixing type laser diode. This LDV system has a simpler structure than any other typical blood flow velocimeter and is composed of new self-mixing probe, stabilizer circuits DSP board, and interf'ace boule We measured velocity of speaker-unit by operational frequencies to identify Doppler effect of this system, performed clinical experiment on bare finger tip and compared it with a commercial euipment BPM403A(USA).

  • PDF

Automatic Optimum Control of the Traffic Signal Lights (교통신호의 자동최적제어에 관한 연구)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • v.20 no.4
    • /
    • pp.12-16
    • /
    • 1971
  • The electrical detector and computer systems for traffic flow and speed measurement are demonstrated in this paper. For the best traffic control optimization, linear and non-linear equations in the transition state are dealing with the perturbation of the linear car-following. In the conclusions, we construct a realizable system for the central automatic traffic control with a computer. Furthermore, fixed periodic switching system by manual with the automatic traffic control system is recommended for emergency perturbation.

  • PDF

Development of Dual Beam High Speed Doppler OFDI

  • Kim, SunHee;Park, TaeJin;Oh, Wang-Yuhl
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.3
    • /
    • pp.283-288
    • /
    • 2013
  • This paper describes development of a high speed Doppler OFDI system for non-invasive vascular imaging. Doppler OFDI (optical frequency domain imaging) is one of the phase-resolved second generation OCT (optical coherence tomography) techniques for high resolution imaging of moving elements in biological tissues. To achieve a phase-resolved imaging, two temporally separated measurements are required. In a conventional Doppler OCT, a pair of massively oversampled successive A-lines is used to minimize de-correlation noise at the expense of significant imaging speed reduction. To minimize a de-correlation noise between targeted two measurements without suffering from significant imaging speed reduction, several methods have been developed such as an optimized scanning pattern and polarization multiplexed dual beam scanning. This research represent novel imaging technique using frequency multiplexed dual beam illumination to measure exactly same position with aimed time interval. Developed system has been verified using a tissue phantom and mouse vessel imaging.

Development of Density Measurement Technique Based on Two Point Detectors and Measurement Reliability According to Different Sensing Gaps (두 지점의 지점검지기를 이용한 밀도측정방안 개발 및 측정간격에 따른 신뢰성 분석)

  • Lee, Cheong-Won;Kim, Min-Seong;Park, Jae-Yeong;Lee, Eun-Gyu
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.3
    • /
    • pp.157-167
    • /
    • 2010
  • Density is the most important congestion indicator among the three fundamental flow variables, flow, speed and density. Measuring density in the field has two different ways, direct and indirect. Taking photos with wide views is one of direct ways, which is not widely used because of its cost and lacking of proper positions. Another direct density measuring method using two point detectors has been introduced with the concept of instantaneous density, average density and measurement interval. The relationship between accuracy and measurement interval has been investigated using the SIMULATION data produced by Paramics Application Programming Interface function. We analyze the affect of segment density accuracy by sensing gap each road condition such as sensing segment length, lane and LOS after gathering data by Paramics Application Programming Interface.

An Analysis on the Emission Reduction Effect of Diesel Light-duty Truck by Introducing Electronic Toll Collection System on Highways (고속도로 영업소의 자동 요금 징수 시스템 도입에 따른 소형 경유 화물트럭의 배출가스 저감 효과 분석)

  • Park, Junhong;Lee, Jongtae;Lee, Taewoo;Kim, Jiyoung;Kim, Jeongsoo;Kil, Jihoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.5
    • /
    • pp.506-517
    • /
    • 2012
  • Electronic Toll Collection System (ETCS), so called "Hi-Pass" in Korea, has improved traffic flow at toll gate of highways. It is known that the improvement of traffic flow should reduce air pollutants and $CO_2$ from vehicles. In this study, real driving emission of a light duty truck with Portable Emission Measurement System(PEMS) has been measured to evaluate the emission reduction effect due to ETCS. The correlations between driving variables and emissions have been analyzed to verify its effect on traffic flow improvement and emission reduction at toll gate. We considered average vehicle speed, Relative Positive Acceleration (RPA), and the distance of queue as driving variables. Compared to passing Manual Toll Collection System (MTCS) lane without queue, ETCS was able to reduce 38.7% of $NO_x$, 21.6% of soot, and 27.7% of $CO_2$. The results showed that the higher the average vehicle speed, the lower RPA and no queue in ETCS contributed to the emission reductions. Linear equation models with RPA and queue have been established by the multiple linear regression method. The linear models resulted in the higher coefficient of determination than those with only average vehicle speed used for establishing vehicle emission factors.

Investigation of the Performance of Spectral Domain Optical Doppler Tomography with High-speed Line Scanning CMOS Camera and Its Application to the Blood Flow Measurement in a Micro-tube

  • Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.174-180
    • /
    • 2012
  • In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.

Experimental Investigation of Local Flow around KRISO 3600TEU Container Ship Model in Towing Tank (KRISO 3600TEU 컨테이너 모형 주위의 국부유동 계측에 관한 연구)

  • Van, Suak-Ho;Kim, Wu-Joan;Kim, Do-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.3
    • /
    • pp.1-10
    • /
    • 2000
  • It is very important to understand the flow characteristics for design of the hull forms with better resistance and propulsive performance. The experimental results explicating the local flow characteristics are also invaluable for validation of the CFD codes for both inviscid and viscous flow calculations. This paper describes the techniques and equipment developed for the measurement of wave pattern on the free surface and local mean velocity fields around the stern of the modern container ship with bow and stern bulbs in KRISO towing tank. The results contained in this paper can provide the valuable information on the flow characteristics of the modern commercial hull form of small block coefficient with high speed.

  • PDF

An Investigation into the effect of friction in the split hopkinson pressure bar (SHPB) test by numerical experiments (수치해석을 이용한 SHPB 시험의 마찰영향 분석)

  • Cha, Sung-Hoon;Shin, Myoung-Soo;Shin, Hyun-Ho;Kim, Jong-Bong
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.204-209
    • /
    • 2008
  • The interest in the mechanical behavior of materials at high strain rates has increased in recent years, and by now it is well known that mechanical properties can be strongly influenced by the speed of applied load. The split Hopkinson pressure bar (SHPB) has been widely used to determine mechanical properties of materials at high loading rates. However, to ensure test reliability, measurement error source must be accounted for and eliminated. During experiment, the specimens were located between the incident and the transmit bar. The presence of contact frictions between the test bars and specimen may cause errors. In this work, numerical experiments were carried out to investigate the effect of friction on test results. In SHPB test, the measured stress by the transmitted bar is assumed to be flow stress of the test specimen. Through the numerical experiments, however, it is shown that the measured stress by the transmit bar is axial stress components. When, the contact surface is frictionless, the flow stress and the axial stress of the specimen are about the same. When the contact surface is not frictionless, however, the flow stress and the axial stress are not the same anymore. Therefore, the measured stress by the transmitted bar is not flow stress. The effect of friction on the difference between flow stress and axial stress is investigated.

  • PDF

Investigation on Shapes and Acoustic Characteristics of Air Bubbles Generated by an Underwater Nozzle (수중 노즐에서 발생하는 기포의 형상 및 음향 특성 연구)

  • Kim, Jong-Chul;Oh, Joon-Seok;Cho, Dae-Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.190-197
    • /
    • 2006
  • It is well known that the acoustic characteristics of the sea are significantly affected by bubbles which have their own inherent characteristics at the undersea. In this study, the shape and acoustic characteristics of air bubbles generated by an underwater nozzle are calculated numerically, and are measured with a high speed camera and a hydrophone at various air flow rates in the experimental apparatus. As a result of analysis, the shape calculated numerically well matched with measured values at low flow rates, but in case of relatively higher flow rates. the use of correction coefficient is needed for more accurate estimation of the bubble shape. And also the rising velocity of a single bubble is constant regardless of both the bubble size and the flow rate. and the acoustic signal generated when the bubble is produced by an underwater nozzle has the same characteristic of natural frequency of the bubble pulsation, and is agreed with Minnaert's equation if the correction coefficient is considered in accordance with the flow rate.