• 제목/요약/키워드: Flow Pulsation

검색결과 187건 처리시간 0.023초

Prediction of the Turbulent Mixing in Bare Rod Bundles

  • Kim, Sin;Chung, Bum-Jin
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.104-115
    • /
    • 1999
  • The turbulent mixing rate is a very important variable in the thermal-hydraulic design of nuclear reactors. In this study, the turbulent mixing rate the fluid flows through rod bundles is estimated with the scale analysis on the flow pulsation phenomenon. Based upon the assumption that the turbulent mixing is composed of molecular motion, isotropic turbulent motion (turbulent motion without the flow pulsation), and How pulsation, the scale relation for the mixing is derived as a function of P/D, Re, and Pr. The derived scale relation is compared with published experimental results and shows good agreements. Since the scale relation is applicable to various Prandtl number fluid flows, it is expected to be useful for the thermal-hydraulic analysis of liquid metal coolant reactors as well as of moderate Prandtl number coolant reactors.

  • PDF

맥동압을 가지는 챔버내의 압력변화에 관한 연구 (Study on the Pressure Variation in a Chamber Caused by Pulsation Pressure)

  • 이중섭;심규진;;정한식;정효민
    • 한국자동차공학회논문집
    • /
    • 제15권4호
    • /
    • pp.132-138
    • /
    • 2007
  • Experimental results of pulsating pressure behavior inside a chamber have been confirmed by computational work. Inside-cylinder pressure shows unstable condition at low rpm. This is caused by plate-type suction valve. It has effect up to inlet of the chamber. But trembling phenomenon is reduced as the pressure is enlarged by increasing the rpm. Result comparison between experimental and numerical analysis shows pulsation reduction is affected by the chamber. We can confirm that compressible effect of the working flow is shown at chamber inlet by increasing rpm. On the other side, this effect is declined at chamber outlet by increasing rpm. It means outlet pressure is going on balance with atmosphere pressure. Buffer plate-type chamber has efficiency of pulsation flow reduction.

기체 중심 동축형 분사기의 접선방향 유입구 지름 변화에 따른 액체 가진 연구 (A Study on Dynamic Characteristics of Gas Centered Swirl Coaxial Injector Varying Tangential Inlet Diameter with Liquid Pulsation)

  • 오석일;박구정;김성주;이형원;윤영빈;최정열
    • 한국분무공학회지
    • /
    • 제22권2호
    • /
    • pp.62-68
    • /
    • 2017
  • It is important to study on the combustion instability to develop liquid rocket engines for preventing lower combustion efficiency and destruction of combustion chamber. There are many researches on simplex injector with liquid pulsation to solve this problem. In real rocket engine system, however, they use coaxial injectors. Therefore, research on coaxial injector with liquid pulsation is essential. In this study, we investigate dynamic characteristics of gas centered swirl coaxial injector varying tangential inlet diameter. A mechanical pulsator was used to generate an excitation in the liquid flow, and the response characteristics of the injector were confirmed. As tangential inlet diameter increased, mass flow rates increased and spray angle decreased. As tangential inlet diamter decreased, gain decreased because the pressure fluctuation in the injector manifold rarely passed through the inlet. Additionally, it was confirmed that a sufficiently small tangential inlet served as a damper.

사판식 피스톤 펌프의 밸브 플레이트 설계와 예압에 따른 맥동 (Pulsation According to Pre-Compression Sections and Valve Plate Design for a Swash Plate Type Piston Pump)

  • 사진웅;정원지;배준형;이정민
    • 한국생산제조학회지
    • /
    • 제25권1호
    • /
    • pp.89-95
    • /
    • 2016
  • This study investigated the design factors of the opening area in order to consider the kinematic stability of a valve plate, conducting an analysis of the reduction effects of pressure pulsation and flow ripple depending on the design factors, using the $SimulationX^{(R)}$ (Germany) hydraulic analysis program. Further, we performed a structure analysis to confirm the kinematic stability of the valve plate in a swash plate type piston pump, and analyzed the effects of pulsation on a 1-step V-type notch, 2-step V-type notch, and 2-step U-type notch to determine the effects of pulsation reduction. Finally, we show the effectiveness of our proposed design of the pre-compression sections on a valve plate in terms of low pulsation by using the hydraulic analysis program, $SimulationX^{(R)}$.

Rijke형 연소기에서 석탄의 맥동연소에 관한 연구 (A study on the pulsating combustion of coal in a Rijke type combustor)

  • 권영필;이동훈
    • 대한기계학회논문집
    • /
    • 제13권3호
    • /
    • pp.508-516
    • /
    • 1989
  • 본 연구는 석탄의 맥동연소과정을 비맥동연소와 빅교실험을 하여 연소특성 을 가시적으로 관찰하고 연소율 등의 연소특성을 구하며 고체연료의 맥동연소과정을 밝히고 맥동연소기 개발의 기초자료를 얻는데 목적을 두었다.

프리필용 체크밸브의 유압진동 특성에 관한 연구 (A Study on the Hydraulic Vibration Characteristics of the Prefill Check Valve)

  • 박정우;한성민;이후승;윤소남
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권3호
    • /
    • pp.8-15
    • /
    • 2021
  • A rear axle steering (RAS) system is attached to the rear of medium and large commercial vehicles that transport large cargo. The existing RAS systems are driven by electro-hydraulic actuator (EHA), and most commercialized EHAs consist of electric motors, hydraulic pumps, relief valves, prefill valves and cylinders. The prefill valve required for such EHAs is a type of check valve with extremely low cracking pressure that should not allow RAS to have noise or vibration, and the prefill valve prevents system negative pressure as well as unstable operation. Most papers on this topic rely on experiments to predict valve performance, and theoretically detailed modeling of valves or pipelines is performed, but it is very rare to evaluate hydraulic vibration characteristics by analysing everything from hydraulic pumps to valves comprehensively. In this study, we proposed an experimental circuit that can predict the performance of the prefill valve. The study also analysed the pressure-flow pulsation that is transmitted to the valve through the pipeline, and how the transmitted pressure-flow pulsation affects the valve vibration.

PIV Analysis of a Pulsating Flow through a Square Channel

  • SAGA Tetsuo;UEDA Toshiyuki;TANIGUCHI Nobuyuki
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.157-168
    • /
    • 2004
  • The effects of pulsation in a pulsating flow through a rectangular channel have been investigated by Particle Image Velocimetry in both laminar and turbulent flow conditions. PIV results on a square channel (aspect ratio:1) have been reported on the cases of Reynolds number Re=80 in laminar and Re=8800 in turbulent region. For both in the laminar and turbulent regions, the influence of the pulsation onto the magnitude changes of the average velocity was negligible. In the turbulent region, the magnitude profiles of the stream-wise pulsating component obtained by the theoretical analysis based on the Stokes analogy were slightly different from the experimental ones due to the influence of the turbulent viscosities onto the pulsating flows.

  • PDF

복합 부수로의 비정상 유동이 유발하는 난류열전달 증진에 대한 LES 해석 (Large Eddy Simulation of Heat Transfer Performance Enhancement due to Unsteady Flow in Compound Channels)

  • 홍성호;신종근;최영돈
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.132-138
    • /
    • 2011
  • In the present article, we investigate numerically turbulent flow of air through compound rectangular channels. Large eddy simulation(LES) is employed for unsteady turbulence modeling. LES gives better predictions for the axial mean velocity distribution than those of other turbulent models. Strong large-scale quasi-periodic flow oscillations are observed in most of the geometries investigated. Such large-scale flow oscillations in compound rectangular channels are similar to the quasi-periodic flow pulsation through the gaps between fuel rod bundle in nuclear reactor. It exists in any longitudinal connecting gap between two flow channels. The frequency of this flow oscillation is determined by the geometry of the gap. The large scale cross motions through the rectangular compound channels induce significant heat transfer enhancement of the compound channel flow.

Performance of water-jet pump under acceleration

  • Wu, Xian-Fang;Li, Ming-Hui;Liu, Hou-Lin;Tan, Ming-Gao;Lu, You-Dong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제13권1호
    • /
    • pp.794-803
    • /
    • 2021
  • The instantaneous acceleration affects the performance of the water-jet pump obviously. Here, based on the user-defined function, the method to simulate the inner flow in water-jet pumps under acceleration conditions was established. The effects of two different acceleration modes (linear acceleration and exponential acceleration) and three kinds of different acceleration time (0.5s, 1s and 2s) on the performance of the water-jet pump were analyzed. The results show that the thrust and the pressure pulsation under exponential acceleration are lower than that under linear acceleration at the same time; the vapor volume fraction in the impeller under linear acceleration is 27.3% higher than that under exponential acceleration. As the acceleration time increases, the thrust gradually increases and the pressure pulsation amplitude at the impeller inlet and outlet gradually decreases, while the law of pressure pulsation is the opposite at the diffuser outlet. The main frequency of pressure pulsation at the impeller outlet is different under different acceleration time. The research results can provide some reference for the optimal design of water-jet pumps.

뜸치료가 뇌졸중 편마비의 요골동맥 혈류변화에 대해 미치는 영향 (Noninvasive Estimation of Moxibustion Effect on Peripheral Blood Flow by Doppler Ultrasound in Stroke Patients with Hemiplegia: Case Series)

  • 윤승규;이상훈;정우상;배영민
    • 대한한의학회지
    • /
    • 제31권4호
    • /
    • pp.178-186
    • /
    • 2010
  • Objectives: This study was to investigate the effect of moxibustion on peripheral blood flow by Doppler ultrasound in post-stroke hemiplegia patients. Methods: Moxibustion was applied on the points of LI4, TE3, TE5 and LI11 on the affected side, and blood flow of the radial artery was measured using the Minimax-Doppler-K device. Blood flow velocity and pulsation index were analyzed before, during, and after moxibustion. Results: The mean value of blood flow velocity in 13 patients showed a tendency of increase during moxibustion, but there was no significant difference in blood flow velocity before and after moxibustion, or pulsation index during and after moxibustion. In addition, among the five patients who showed marked increase tendency on the blood velocity graph, there was significant increase in blood velocity during, and after moxibustion compared with before moxibustion. Conclusions: This study suggests that moxibustion has an effect on peripheral blood flow in stroke patients with hemiplegia. Further validity tests with a larger scale sample are needed for the evidence of its practical use.