• 제목/요약/키워드: Flow Noise Source

검색결과 220건 처리시간 0.02초

냉장고 기계실 축류홴 소음의 수치적 연구 (Numerical study on the machine room axial flow fan of a refrigerator)

  • 전완호;김욱;신대식;김현주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1002-1006
    • /
    • 2006
  • The noise of a refrigerator is consisted of the various flow noises of a refrigerator fan, a compressor and a condenser fan. The demands of high flow rate, compact space and low noise are to be accommodated, especially, in the case of a premium refrigerator. In this study, flow field, noise sources and flow noise are analyzed numerically and compared to the measured data. The flow field is calculated with 3-dimensional CFD solver - SC/Tetra, and the noise source and aeroacoustic noise is analyzed with FlowNoise S/W. Low noise axial fan can be developed by controlling the dominant noise source area.

  • PDF

등/부등피치 횡류홴의 유동 소음 특성 (Flow Induced Noise Characteristics of the Cross Flow Fan with Uniform/Random Pitch Blades)

  • 조용;문영준;박진무
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.621-626
    • /
    • 2001
  • The flow induced noise of the cross-flow fan with uniform/random pitch blades is predicted by computational methods. With the time dependent surface pressure data obtained by solving the incompressible Navier-Stokes equations in moving coordinates, the acoustic pressure is predicted by the Ffowcs Williams-Hawkings equation. The positions of the blade noise source are identified through an investigation of the acoustic pressure history induced by one blade, and it is confirmed that the dominant noise source is near the stabilizer. Since the acoustic pressure of the random pitch fan fluctuates according to the blade passin, the dominant BPF noise of the uniform pitch fan is modulated into some reduced discrete noises which have multiples of a 50Hz difference from BPF.

  • PDF

시로코 팬의 3차원 유동해석 및 소음원에 관한 연구 (A Study on Three-Dimensional Flow Analysis and Noise Source of Sirocco Fan)

  • 강정석;김진택;이철형;백병준
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.896-902
    • /
    • 2018
  • 본 논문에서는 환기를 위한 시로코 팬의 내부에서 유동 및 소음을 해석하기 위해 상용프로그램으로 해석하였다. 소음원의 위치와 크기만을 확인하기 위해 유동해석은 정상 상태 유동 해석을 진행하였다. 유동 해석을 통해 시로코 팬의 내부에서 발생하는 유동의 속도와 속도 벡터로 유동의 흐름을 보았다. 내부의 압력 분포는 contour로 결과를 보았다. 정상 상태 유동 해석 결과에서 Curle surface acoustic power와 Proudman acoustic power를 활용하여 해석결과로부터 소음원의 위치와 크기를 볼 수 있다. Curle surface acoustic power으로 표면에서 발생하는 소음을 볼 수 있다. Proudman acoustic power으로 유동영역에서 발생하는 소음을 볼 수 있다. 정상 상태에서 시로코 팬의 내부에서 발생하는 소음원의 위치와 크기만 볼 수 있기 때문에 발생하는 소음의 주파수를 확인하기 위해서는 추가적으로 비정상 상태 해석을 진행할 필요가 있다. 본 연구를 통해 시로코 팬의 성능을 향상시키고 소음을 저감하기 위한 연구의 기초 자료가 될 것으로 기대된다.

밸브소음 스케일링에 관한 연구 (A study on Acoustic Similarity of Cavitating Valve Noise)

  • 이재환;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.471-477
    • /
    • 1998
  • A constant flow-rate control valve provides effective distributions and controls of running water in a pipe system. The noise characteristics were measured to reveal the noise sources depending on pressure differences across a valve. Valve noise is mostly dominated by bubble dynamics under cavitating conditions. In this study, the sound powers from a flow control valve of constant flow rates are effectively normalized. Flow-excited dynamic systems for which there is no strong coupling between the flow and the system response can be described using a linear source-filter model. On this assumption, the normalized sound powers can be decomposed of noise source function and a response function. The source spectra in, terms of cavitation frequency show cavitation events occurring at narrow banded frequencies greater than 10 kHz. There also possibly exist two kinds of cavitating modes based on our experimental data.

  • PDF

An Experimental Study for Noise Reduction of the Cross-Flow Fan of the Room Air-Conditioners

  • Koo, Hyoung-Mo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.89-100
    • /
    • 2000
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectra of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed, which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared with and without the bounding fence for various flow rates.

  • PDF

에어컨용 직교류홴의 저소음화를 위한 실험적 연구 (An experimental study for noise reduction of the cross-flow fan of the room air-conditioners)

  • 구형모
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.871-879
    • /
    • 1999
  • Present study explains some experimental results on the aerodynamic noise of the cross-flow fan usually installed in the indoor unit of the room air-conditioners and provides a simple reduction method of radiating sound to decrease the total noise level. The spectrums of the noise of the cross-flow fan were analyzed by the spectral decomposition method to characterize the generated sound. The unsteady fluctuating flow field was also measured using the I-type hot-wire probe. Comparing the spectral characteristics of the sound and the flow velocity, a useful noise reduction method was proposed which bounds the region with a fence where the flow fluctuations were noticeably changed in the same fashion as the source spectral distribution functions vary. To validate the proposed method for reducing noise generated by the cross-flow fan, the sound pressure levels of the cross-flow fan system were compared of the experimental rig with and without the bounding fence for various flow rates.

  • PDF

터보형송풍기의 소음 방사특성에 관한 실험적 연구 (A Study on the Noise Emission Characteristics of Turbo Axial Flow Fan by Experimental Method)

  • 김동규;백종진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.271-277
    • /
    • 2003
  • 최근 환경 소음이 사회적인 문제로 대두되고 있는 가운데, 생활수준의 향상으로 저소음화에 대한 요구가 증가되고 있는 실정이다. 이와 같이 소음에 관한 일반인들의 관심이 높아지면서 생환주변에서 주요 소음원으로 지적되고 있는 회전기계, 특히 가전제품을 비롯한 유동관련 기계류의 소음을 낮추기 위한 노력이 절실히 요구되고 있다. 본 소평팬에 대한 연구에서는 음압 및 음향인텐시티를 이용하여 소음원을 해석하였다. 이때, 광센서를 이용한 축류형 팬의 동기화가 수행되어졌고, 팬 형상에서 정확한 소음원의 위치를 규명하기 위한 기록시간의 결정이 제안되어졌다. 소음 발생하는 위치를 규명하였고, 지향성 연구를 통하여 축류형 팬의 방사형태를 결정하였으며, 음의 흐름도를 가시화 하였다.

  • PDF

오리피스 구조내에서 발생한 공동소음의 음향학적 스케일링에 관한 연구 (A study on the acoustic scalings of cavitation noise in an orifice configuration and a constant flow control valve)

  • 이재환;이승배;유선학
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.81-89
    • /
    • 1999
  • The major source of noise in the process of transporting liquids is related to the cavitation phenomenon. The control valve noise is mostly dominated by bubble dynamics under cavitating conditions. In this investigation, an orifice configuration is set-up to correlate its flow-field and acoustic signatures with those from a control valve device. The performance and noise characteristics form the orifice configuration in anechoic surroundings were measured to reveal the noise sources depending on pressure differences across the orifice configuration. The sound powers from the orifice configuration are effectively normalized using proposed scaling parameters. Flow-excited dynamic systems for which there is no strong coupling between the flow and the system response can be described using a linear source-filter model. On this assumption, the normalized sound powers can be decomposed of noise source function and a response function. To find noise sources, pressure spectra measured over a range of pressure differences are transformed into the product of two non-dimensional frequency function : $P_{ss}(He,f_{ca},x/D) = F(f_{ca})\;G(He,x/D)$. This scheme of finding noise sources is shown to be applicable to the cavitation noise from the control valve effectively Two kinds of cavitating modes based on our experimental data are found and discussed.

  • PDF

2차원 공동 유동에서의 소음원 위치 판별을 위한 실험적 연구 (Experiments for the Acoustic Source Localization in 2D Cavity Flow)

  • 이재형;박규철;최종수
    • 한국소음진동공학회논문집
    • /
    • 제14권12호
    • /
    • pp.1241-1248
    • /
    • 2004
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone array. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in an anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures and their spectral contents are affected by the cavity parameter L/D.

마이크로폰 어레이를 이용한 2차원 공동 유동에 대한 소음원 규명 (Acoustic Source Localization in 2D Cavity Flow using a Phased Microphone Array)

  • 이재형;최종수;박규철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.701-708
    • /
    • 2003
  • This paper presents an acoustic source localization technique on 2D cavity model in flow using a phased microphone way. Investigation was performed on cavity flows of open and closed types. The source distributions on 2D cavity flow were investigated in anechoic open-jet wind tunnel. The array of microphones was placed outside the flow to measure the far field acoustic signals. The optimum sensor placement was decided by varying the relative location of the microphones to improve the spatial resolution. Pressure transducers were flush-mounted on the cavity surface to measure the near-filed pressures. It is shown that the propagated far field acoustic pressures are closely correlated to the near-field pressures. It is also shown that their spectral contents are affected by the cavity parameter L/D.

  • PDF