• Title/Summary/Keyword: Flow Injection Analysis

Search Result 716, Processing Time 0.03 seconds

Development and Validation of HPLC Method for Pharmacokinetic Study of Promethazine in Human (염산프로메타진 체내동태 연구를 위한 혈청 중 프로메타진의 HPLC 정량법 개발 및 검증)

  • Cho, Hae-Young;Kang, Hyun-Ah;Lee, Hwa-Jeong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.1
    • /
    • pp.23-29
    • /
    • 2006
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of promethazine in human serum was developed, validated, and applied to the pharmacokinetic study of promethazine. Promethazine and internal standard, chlorpromazine, were extracted from human serum by liquid-liquid extraction with n-hexane containing 0.8% isopropanol and analyzed on a Capcell Pak CN column with the mobile phase of acetonitrile-0.2 M potassium dihydrogen phosphate (42:58, v/v, adjusted to pH 6.0 with 1 M NaOH). Detection wavelength of 251 nm and flow rate of 0.9 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^{3}$ factorial design using a fixed promethazine concentration (10 ng/mL) with respect to its peak area and retention time. In addition, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of 1-40 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 1 mL of serum was 1 ng/mL, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 96.15 to 105.40% for promethazine with overall precision (% C.V.) being 6.70-11.22%. The relative mean recovery of promethazine for human serum was 63.54%. Stability (freeze-thaw and short-term) studies showed that promethazine was stable during storage, or during the assay procedure in human serum. However, the storage at $-80^{\circ}C$ for 4 weeks showed that promethazine was not stable. Extracted serum sample and stock solution were not allowed to stand at ambient temperature for 12 hr prior to injection. The peak area and retention time of promethazine were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of promethazine in human serum samples for the pharmacokinetic studies of orally administered Himazin tablet (25 mg as promethazine hydrochloride) at three different laboratories, demonstrating the suitability of the method.

Determination of Betaine in Fructus Lycii Using Hydrophilic Interaction Liquid Chromatography with Evaporative Light Scattering Detection

  • Shin, Hyun-Du;Suh, Joon-Hyuk;Kim, Jung-Hyun;Lee, Hye-Yeon;Eom, Han-Young;Kim, Un-Yong;Yang, Dong-Hyug;Han, Sang-Beom;Youm, Jeong-Rok
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.553-558
    • /
    • 2012
  • A simple new method was developed for the determination of betaine in Fructus Lycii using hydrophilic interaction liquid chromatography with evaporative light scattering detection (HILIC-ELSD). Good chromatographic separation and reasonable betaine retention was achieved on a Kinetex HILIC column ($2.1{\times}100mm$, $2.6{\mu}m$) packed with fused-core particle. The mobile phase consisted of (A) acetonitrile and (B) 10 mM ammonium formate (pH 3.0)/acetonitrile (90/10, v/v). It was used with gradient elution at a flow rate of 0.7 mL/min. The column temperature was set at $27.5^{\circ}C$ and the injection volume was $10{\mu}L$. The ELSD drift tube temperature was $50^{\circ}C$ and the nebulizing gas (nitrogen) pressure was 3.0 bar. Stachydrine, a zwitterionic compound, was used as an internal standard. Calibration curve over $10-250{\mu}g/mL$ showed good linearity ($R^2$ > 0.9992) and betaine in the 70% methanol extract of Fructus Lycii was well separated from other peaks. Intraand inter-day precision ranged from 1.1 to 3.0% and from 2.4 to 5.3%, respectively, while intra- and inter-day accuracy ranged from 100.0 to 107.0% and from 94.3 to 103.9%, respectively. The limit of quantification (LOQ) was $10{\mu}g/mL$ and the recoveries were in the range of 98.2-102.7%. The developed HILIC-ELSD method was successfully applied to quantitatively determine the amount of betaine in fourteen Fructus Lycii samples from different locations, demonstrating that this method is simple, rapid, and suitable for the quality control of Fructus Lycii.

Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD (전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선)

  • Kim, Min-Choul;Shon, Byung-Hyun;Lee, Jae-Jeong;Park, Hung-Suck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.460-468
    • /
    • 2021
  • This study investigated the enhanced combustion efficiency of an "air-cooled combustion system" with single F.D. fan, and performed a numerical analysis for the operation and design conditions to increase the combustion efficiency. The combustion efficiency in an actual combustor was compared before and after the structure modification. Numerical analysis for application of a single fan revealed the difficulty of forming a turbulence for circular combustion conditions. This is because the supply ratio of combustion air supplied into 2 flow paths becomes irregular in the combustion furnace due to a change in friction force and pressure in each flow path. Subsequently, two methods of supplying air into the combustion furnace were analyzed numerically to obtain the optimal combustion conditions of an air-cooled combustion system. The first method involved injecting the preheated combustion air after a 180~360 degree rotation from the outer wall, whereas in the second method, the combustion air was injected into the combustion furnace in a tangential direction after primary heat exchange outside the combustion furnace, by applying a rotatable vane structure in the combustion furnace. Results reveal that application of a single F.D. fan to the air injection into a rotatable combustion furnace is desirable for optimization of the combustion conditions for applying a duct structure having a dual cooling wall for the cooling of the outer wall of the combustion furnace, and for maintaining perfect mixing in the combustion furnace. We therefore confirmed enhanced combustion efficiency by comparing the actual combustion efficiency before and after structure modification.

The Clinical Analysis of Sulcus Vocalis (성대구증에 관한 임상적 고찰)

  • 김광문;서장수;오혜경;최홍식;김기령
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.11.2-12
    • /
    • 1982
  • The major advancement in phonosurgery due to recent development of laryngomicrosurgery enabled more accurate diagnosis and treatment of patient with voice disorders. Among large proportion of voice disordered patients, prominent linear furrow running parallel along the free edge of vocal cord extending from the vocal process to anterior commissure can be seen as well as incomplete closure during phonation. These cases were illustrated and coined as sulcus vocalis by Salvi in 1901, since then other similar paper was reported in Europe and Japan, but has not been reported in Korea. The exact etiology and therapeutic methods of sulcus vocalis has not been elaborated. At Department of Otolaryngology of Yonsei University College of Medicine a series of voice analysis were performed among those 35 patients with sulcus vocalis visited to Vocal Dynamics Laboratory from May, 1981 to March, 1982. Following is the result of clinical statistical investgation and therapeutic modality. 1) The incidance of sulcus vocalis among 290 patients with voice disorder visited to Vocal Dynamics Laboratory was approximately 12%(35 cases). 2) Onset of this voice disorder was most frequent among patient under 10 year-old groups; 19 cases (54%) followed by second decade, third decade groups in decreasing frequency respectably. 3) The etiology of sulcus vocalis was mostly unknown. The sequelae after measle (4 cases) and severe upper respiratory infection (3 cases) and congenital deformity (2 cases) were the possible causes of sulcus vocalis. 4) These patients were involved bilaterally in 25 cases (71%), left side only in 8 cases (23%) and right side only in 2 cases (6%). 5) Almost all patients complained hoarseness and 7 patients were suffering from chronic laryngitis. 6) In aerodynamic analysis, Maximal Phonation Time was decreased in 20 cases (57%), Phonation Quotient was increased in 22 cases (63%) and Mean Air Flow Rate was increased in 23 cases (66%). 7) Among them, 33 cases were analyzed with stroboscopy. The findings were as follows; incomplete glottic closure during phonation in 31 cases (93%), regular vocal cord movement in whole cases, asymmetric cord movement in 4 cases (12%), decreased amplitude in 5 cases (21%) and small mucosal wave in 24 cases (73%). 8) Intracordal Teflon injection in 5 cases and Sulcusectomy in 1 cases were performed as therapeutic management, however, the therapeutic results were not effective except one case with Teflon injection.

  • PDF

Thyroplasty for the Restoration of a Normal Voice (음성개선을 위한 갑상연골성형술)

  • 김기령;김광문;정명현;이원상;정승규
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.10.1-10
    • /
    • 1982
  • The use of phonosurgery in the recent development of laryngomicrosurgery has enabled the restoration of a normal voice in respect to functional laryngeal surgery which in Korea in the past limited to simple removal of benign laryngeal tumor such as laryngeal polyp or nodules and cordal injection of $Teflon^{{\circledR}}$ for the treatment of recurrent nerve paralysis under the vision of suspension laryngoscopy. Performance of phonosurgery for the treatment of cord paralysis, mutational dysphonia, vocal cord atrophy, hyperkinetic dysphonia and sulcus vocalis is a happy event in the view point of development of phonosurgery in Korea. In this aspect thyroplasty to change the position and physical characteristics of the cord outside the glottis instead of the direct handling of the vocal cord through direct endoscopy is popular. Among the 4 types of thyroplasty, classified by Insshiki(1974), type I thyroplasty(1ateral compression of vocal cord) and type IV thyroplasty(lengthening of vocal cord) were effective in the treatment of unilateral vocal cord paralysis. Advantages of this operation are the fine adjustment of the degree of lateral compression under local anesthesia according to the phonation of the patient during operation and avoidance of dyspnea and intralaryngeal hemorrhage due to the manipulation outside the internal perichondrium of the thyroid cartilage. We did 7 cases of thyroplasty for the treatment of unilateral vocal cord paralysis in the 7 months from September 1981 to March 1982. Before the operation aerodynamic study, psychoacoustical evaluation, stroboscopy and sound spectrographic analysis were done. Two months after the operation the above procedures were performed again. Results of preoperative and postoperative examination were compared and the following results were obtained. 1) In the aerodynamic study, maximum phonation time increased to 158% of the preoperative value and the phonation quotient and the mean flow rate decreased to 58% and 54% of preoperative values. 2) The degree of hoarseness improved in the psychoacoustical evaluation and the glottic chink during phonation was decreased in the stroboscopic examiantion. 3) In the sound spectrographic analysis, periodicity was much restored and noise distribution decreased especially in the high frequency area.

  • PDF

Ozone-Enhanced Remediation of Diesel-Contaminated Soil (II): A Column Study (Ozone에 의한 유류오염토양 복원 연구 (II) : 토양 컬럼상에서의 오존 산화)

  • Choi, Heechul;Heechul;Lim, Hyung-Nam;Kim, Kwang-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1825-1832
    • /
    • 2000
  • Column experiments were conducted by using soil columns, to investigate feasibility and efficiency of in-situ ozone enhanced remediation for diesel-contaminated soil. The injection of gaseous ozone into soil column revealed the enhanced decomposition of ozone due to the catalytic reaction between ozone and metal (e.g., Fe, Mn etc.) oxides as evidenced by as much as 25 times shorter half-life of ozone in a sand packed column than in a glass beads packed column. Substantial retardation in the transport of and the consumption of ozone were observed in the diesel contaminated field soil and sand packed columns. After 16 hrs ozonation, 80% of the initial mass of diesel (as diesel range organic) concentration of $800{\pm}50mg/kg$, was removed under the conditions of the flow rate of 50mL/min and $6mg-O_3/min$. Whereas, less than 30% of diesel was removed in the case of air injection. Analysis of the residual TPH(total petroleum hydrocarbon) and selected 8 aliphatics of diesel compounds in the inlet and the outlet of the column confirmed that diesel nonselectively reacted with ozone and then shifted to lower carbon numbered molecules. Water content also was found to be an important parameter in employing ozone to the hydrocarbon-contaminated soil.

  • PDF

A Study on Operation Control Technology Required for Introduction of Intelligent Sewage Treatment Plant (스마트 하수처리장 도입에 필요한 운전제어기술에 관한 연구)

  • Lee, Jiwon;Kim, Yuhyeon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.38-43
    • /
    • 2022
  • Smart sewage treatment plant means creating a safe and clean water environment by establishing an ICT-based real-time monitoring, remote control management and intelligent system for the entire sewage treatment process. The core technology of such a smart sewage treatment plant can be operation control technology using measuring instruments. This research team analyzed and suggested the operation control technologies necessary for the establishment of the intelligent business by referring to the intelligent research projects of the sewage treatment plant in progress in Korea. As a result of the analysis, a total of six removal technologies were presented, including control by scale, reflow water control, linked treated water control, chemical quantity control, winter operation control, and total organic carbon control. By size, standards that can be classified into small and medium-sized large-scale are presented, and in the case of reflow water control, the location of water quality and flow sensors capable of managing reflow water is suggested. In the case of the linked treated water control, the influence and control points of the linked treated water on the sewage treatment plant were presented, and in the case of the chemical injection volume control, a system capable of optimizing the amount of chemical injection according to the introduction of an intelligent sewage treatment plant was presented. In the case of winter operation, the sensors and pumps to be controlled are suggested when considering the decrease in nitrification due to the decrease in water temperature. In the case of total organic carbon control, an interlocking system considering the total amount of pollution in the future was proposed. These operation control scenarios are expected to be used as basic data to be used in intelligent sewage treatment algorithms and scenarios in the future.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

The Whole Region Pressure Measurement of Cavity Downstream using PSP Technique (PSP를 이용 다양한 공동 후류의 전역적 압력분포 측정)

  • Seo, Hyung-Seok;Oh, Ju-Young;Jeon, Young-Jin;Lee, Jae-Woo;Byun, Yung-Hwan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.6
    • /
    • pp.50-57
    • /
    • 2007
  • Pressure Sensitive Paint(PSP) means a reacting paint in pressure. PSP can measure continuous pressure field by analyzing the oxygen quantity using optical method. The surface pressure of down stream after the sonic jet that injected transversely into the supersonic freestream was measured by PSP technique. Moreover the effect of various rectangular shaped cavities in front of the jet was measured by PSP technique. A comparison of the PSP results with conventional pressure tap and CFD indicates good agreement. Until now, the results of numerical analysis were compared with the discrete points such as the results of pressure tap. In this study, the whole region pressure was measured using PSP technique and its results were similar to CFD. Therefore, the flow phenonenon of cavity downstream was clearly grasped.

Cellular and Humoral Immune Responses to Sequential Periodontopathic Bacterial Immunization in Animal Model (상이한 치주병원균의 연속적 인공면역에 대한 세포성 및 체액성 면역반응에 대한 동물실험적 연구)

  • Jeon, Soo-Kyung;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.3
    • /
    • pp.687-700
    • /
    • 2000
  • Antigen-specific T cell clones were obtained from mice immunized with Fusobacterium nucleatum ATCC 10953(F .nucleatum) and/or Porphyromonas gingi valis 381(P. gingivalis). 10 Balb/c mice per group were immunized with F. nucleatum followed by P. gingivalis, or with P. gingivalis alone by intraperitoneal injection of viable microorganisms. Spleen T cells were isolated and stimulated in vitro with viable P. gingivalis cells to establish P. gingivalisspecific T cell clones. T cell phenotypes and cytokine profiles were determined along with T cell responsiveness to F .nucleatum or P. gingivalis. Serum IgG antibody titers to F. nucleatum or P. gingivalis were also determined by ELISA. All the T cell clones derived from mice immunized with F. nucleatum followed by P. gingivalis demonstrated Th2 subsets, while those from mice immunized with P. gingivalis alone demonstrated Th1 subsets based on the flow cytometric analysis and cytokine profiles, All T cells clones from both groups were cross-reactive to both P. gingivalis and F. nucleatum antigens. Phenotypes of T cell clones were all positive for CD4. Mean post-immune serum IgG antibody levels to F. nucleatum or P . gingivalis were significantly higher than the pre-immune levels(p <0.01, respectively). There were no significant differences in the antibody titers between the two groups. It was concluded that P. gingivalis-specific T cells initially primed by cross-reactive F. nucleatum antigens were polarized to Th2 subsets, while T cells stimulated with P. gingivalis alone maintained the profile of Th1 subset.

  • PDF