• 제목/요약/키워드: Flow Injection Analysis

검색결과 722건 처리시간 0.03초

1차원 수치 해석을 통한 강내탄도 성능해석 (Performance Analysis of Interior Ballistics using 1-D Numerical Method)

  • 장진성;성형건;노태성;최동환
    • 한국군사과학기술학회지
    • /
    • 제15권3호
    • /
    • pp.241-249
    • /
    • 2012
  • Performance analysis of the interior ballistics has been conducted using the 1-D numerical code called IBcode according to the various conditions such as length of ignition-gas injector, amount of ignition-gas, mass of projectile, and drag force of projectile. In case of the length of ignition-gas injector, the 25~100 % of the full-injector length has been considered as well as the mass & mass flow of the ignition-gas. The mass of the projectile 5~70 kg and its drag force of 0~69 MPa have been also considered. Variables such as breech & base pressure, negative differential pressure and muzzle velocity for the performance analysis have been sorted, too. Firing conditions for the optimal performance have been investigated through these variables.

Quantitative Analysis of Twelve Marker Compounds in Palmijihwang-hwan using Ultra-Performance Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Natural Product Sciences
    • /
    • 제20권3호
    • /
    • pp.182-190
    • /
    • 2014
  • An ultra-performance liquid chromatography (UPLC) coupled with electrospray ionization (ESI) tandem mass spectrometry (MS) method was established for quantitative analysis of twelve components, allantoin (1), morroniside (2), 5-hydroxymethyl-2-furfural (5-HMF) (3), loganin (4), coumarin (5), cinnamic acid (6), mesaconitine (7), cinnamaldehyde (8), hypaconitine (9), aconitine (10), alisol B (11), and alisol B acetate (12) in a Palmijihwang-hwan decoction. The twelve constituents were separated on a UPLC BEH C18 column ($2.1{\times}100mm$, $1.7{\mu}m$) at a column temperature of $40^{\circ}C$ by gradient elution with 0.1% (v/v) formic acid in water and acetonitrile as the mobile phase. The flow rate was 0.3 mL/min and the injection volume was $2.0{\mu}L$. Calibration curves of all compounds were acquired with values of the correlation coefficient ${\geq}0.99$ within the test ranges. The limits of detection and quantification for all analytes were 0.01 - 4.53 ng/mL and 0.03 - 13.60 ng/mL, respectively. The concentrations of the compounds 1 - 9 and 12 were 72.83, 4389.00, 4859.00, 3155.17, 223.67, 33.50, 1.97, 518.00, 2.25, and $25.00{\mu}g/g$, respectively. However, compounds 10 and 11 were not detected.

과산화수소 혼합냉각기 내의 노즐배치 및 가스분사 방식 변화에 따른 혼합율 개선에 대한 전산해석적 연구 (CFD Analysis on the Effect of the Nozzle Arrays and Spray Types in the Hydrogen Peroxide Mixing Quencher to Improve the Mixing Efficiency)

  • 구성모;장혁상
    • 청정기술
    • /
    • 제23권1호
    • /
    • pp.42-53
    • /
    • 2017
  • 탈질과 탈황을 동시에 수행하는 과산화수소($H_2O_2$) 수용액 세정탑의 반응효율을 증가시키기 위해 예혼합이 이루어지는 혼합 냉각기(mixing quencher) 영역 내부의 유체유동에 대한 수치해석이 수행되었다. 산업공정에서 상용화되고 있는 세정탑 전단부의 혼합냉각기에서 과산화수소 수용액이 주입되는 노즐의 분사방식은 배기가스와 과산화수소 수용액의 혼합에 중요한 역할을 하며, 혼합냉각기에서의 혼합도는 세정탑 의 효율을 결정하는 중요 요소가 된다. 본 연구에서는 혼합냉각기 내부유체의 농도분포 개선을 목적으로 하여 혼합냉각기 내의 노즐 관의 배열을 조절하거나 노즐 팁 각도를 변경하며 유체혼합을 최적화하였다. 전산해석은 이 냉각기영역의 내부유동 및 각 유체 농도에 대한 RMS (root mean square) 값을 계산하여 내부유체의 혼합도의 개선을 확인하였다. 세부적으로는 노즐 관의 위치를 조절할 때 변경되는 냉각기 영역 후단의 농도 RMS 값을 확인하여 난류형성위치에 따른 최적화된 혼합도를 확인하였으며 기본형상 대비 난류형성방향을 조절하는 목적의 노즐 팁 각도를 증감하여 농도분포의 균질화를 비교하였다. 노즐 관의 배열에 따라 난류형성위치와 그에 따른 유체혼합이 해석되었다. 또한 노즐 팁 각도를 조절하는 경우에는 유동방향과의 각도에 따라, 흐름이 병류와 향류에 따라 혼합도의 최적화를 확인할 수 있었다. 노즐 관의 위치는 0.3 m, 노즐 팁은 병류의 $15^{\circ}$일 때 최적의 조건을 가지며 가장 낮은 RMS 값인 12.4%를 가졌다.

발전소 정전사고 시 Hybrid SIT의 냉각성능 평가를 위한 안전해석에 관한 연구 (Study on the Safety Analysis on the Cooling Performance of Hybrid SIT under the Station Blackout Accident)

  • 류성욱;김재민;김명준;전우진;박현식;이성재
    • 에너지공학
    • /
    • 제26권3호
    • /
    • pp.64-70
    • /
    • 2017
  • 한국원자력연구원에서 제안한 혼합형 안전주입탱크 (Hybrid SIT)는 APR+ 원자로에 적용하기 위해 개발된 피동안전주입시스템이다. 본 연구는 대표적인 고압사고인 발전소정전사고 시 Hybrid SIT의 냉각성능을 평가하기 위해 열수력 안전해석 코드인 MARS-KS 코드를 이용한 예비해석에 대한 것이다. PAFS 구동이 정지되면, 열제거량이 감소하게 되어 가압기와 증기발생기의 압력이 상승하기 시작하며, 가압기의 압력이 안전감압계통(Pilot Operated Safety and Relief Valve) 개방 설정치인 17.03 MPa에 도달하면, 그와 동시에 Hybrid SIT의 증기격리밸브가 열림으로서 가압기 상단의 증기가 Hybrid SIT로 주입되게 된다. 주입된 증기에 의해 압력평형이 빠른시간 안에 이루어졌으며, 주입배관을 통해 냉각수가 주입 되었다. 발전소정전사고시 PAFS와 같은 열제거수단이 상실됨에도 혼합형 Hybrid SIT가 주입되는 시간동안은 노심의 수위가 유지됨을 확인할 수 있었고, 수위가 유지됨에 따라 노심 출구 온도(CET)의 상승을 방지함을 확인하였다.

터널 화재시 연기확산 차단을 위한 양방향 토출 에어커튼 시스템에 대한 연구 (The Study on the Bi-directional Ejection Air Curtain System for Blocking Smoke Diffusion in case of Tunnel Fire)

  • 양상호;최영석;김정엽;김남구;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.43-53
    • /
    • 2014
  • This paper presents a the study on air curtain system of top and bottom bi-directional jet air discharge for blocking the spread of smoke in case of tunnel fire. The five kinds different air curtains of A, B, C, D, and E of models for various performance tested after manufactured. A results of the various performance test obtained the best efficiency from E model air curtain. And optimize the injection angle of the air curtain nozzle through the three-dimensional computational fluid dynamics (CFD) analysis and analyzed the effects of external pressure of tunnel. and also single factor design have been applied. At present, our attention is focused on the velocity distribution(flow width and flow position) of 1.5m on the ground in tunnel. Also, analyzed the influence of draft in the tunnel. Detailed effects of discharge angle of air curtain and velocity at nozzle exit are discussed.

POD와 DMD를 이용한 와류형 분사기의 극저온 질소 분무 동적 특성 분석 (Dynamic Characteristics Analysis of the Cryogenic Nitrogen Injection of Swirl Injector using POD and DMD)

  • 강정석;성홍계;손채훈
    • 한국추진공학회지
    • /
    • 제21권5호
    • /
    • pp.1-9
    • /
    • 2017
  • 초임계 환경에서 와류형 분사기의 극저온 질소 분무 동적 특성 분석을 위하여 3차원 LES 난류 모델을 적용하였다. 초임계 상태에서 질소의 상태량들을 정확하게 예측하기 위해 SRK 실기체 상태방정식을 사용하였고, 점성계수와 열전도도는 Chung의 고압 상태 혼합물에 대한 방정식, 그리고 확산 계수는 Fuller의 이론에 Takahashi의 보정식을 적용하였다. 질소 분무 결과, 분사기 내, 외부에서 유동장과 음향장 사이의 상호작용으로 복잡한 유동구조가 형성된다. 복잡한 유동 현상을 분석하기 위해 FFT, POD 그리고 DMD 기법을 적용하여 해석을 수행하였다. FFT 해석을 수행하여 분사기 내, 외부에서 나타나는 특정 주파수를 파악하였으며, POD와 DMD를 통해 각 주파수가 어떠한 유동 구조를 갖는지에 대한 연구를 수행하였다. 또한, DMD를 통해 각 주파수의 감쇠 계수를 파악하여 이를 실험 결과와 비교하였다.

대수층 축열 에너지(ATES) 시스템 모델에서 지하수 유동 영향에 의한 지반내 온도 분포 예측 시뮬레이션 (Simulation of thermal distribution with the effect of groundwater flow in an aquifer thermal energy storage (ATES) system model)

  • 심병완
    • 한국지열·수열에너지학회논문집
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) can be a cost-effective and renewable geothermal energy source, depending on site-specific and thermohydraulic conditions. To design an effective ATES system having the effect of groundwater movement, understanding of thermohydraulic processes is necessary. The heat transfer phenomena for an aquifer heat storage are simulated by using FEFLOW with the scenario of heat pump operation with pumping and waste water reinjection in a two layered confined aquifer model. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at the both wells during 365 days. The average groundwater velocities are determined with two hydraulic gradient sets according to boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions of three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.001 are shaped circular, and the center is moved less than 5 m to the direction of groundwater flow in 365 days simulation period. However at the hydraulic gradient of 0.01, the contour center of the temperature are moved to the end of east boundary at each slice and the largest movement is at bottom slice. By the analysis of thermal interference data between two wells the efficiency of the heat pump system model is validated, and the variation of heads is monitored at injection, pumping and no operation mode.

  • PDF

오존의 정수처리 적용을 위한 오존소비인자에 관한 연구 (A Study on the Ozone Consumption Rate for Drinking Water Treatment Process with Ozone Application)

  • 강태희;오병수;권순범;손병용;강준원
    • 대한환경공학회지
    • /
    • 제27권6호
    • /
    • pp.663-669
    • /
    • 2005
  • 본 연구에서는 정수처리 공정에서 오존을 보다 효율적으로 적용하기 위하여 수중의 오존소비특성을 파악하고자 하였다. 오존의 소비특성을 측정하기 위하여 흐름주입분석법(FIA: Flow injection analysis)의 원리를 이용하여 오존분해속도 측정 자동화장치를 제작하였다. 수중의 오존농도를 연속적으로 측정함으로써 오존의 소비 경향은 순간적으로 오존이 소모되는 구간(I.D: instantaneous ozone demand)과 의사 1차 반응($k_c$: pseudo first-order rate constant)으로 소모되는 두 구간으로 나누어지며, 각 구간에서 오존 주입량에 의하여 영향을 받는 것으로 나타났다. 또한 I.D와 $k_c$값을 이용하여 구한 모델식으로부터 시간에 따른 오존 잔류농도를 예측할 수 있었으며, 예측된 모델간은 실험값과 비교하였을 때 거의 일치하는 것을 알 수 있었다. OH 라디칼의 농도 및 $R_{ct}$는 OH 라디칼 probe compound를 이용하여 간접적으로 계산하였다. I.D와 $k_c$ 구간에서 OH 라디칼 생성 경향을 파악할 수 있었으며, OH 라디칼 생성 또한 오존 주입량에 의하여 영향을 받는다는 것을 확인하였다. 마지막으로 정수처리 공정 및 계절에 따른 수질 차이에 의해서 오존소비인자가 변화하는 것을 확인하였으며, 이에 따라 오존공정의 적절한 도입위치 및 주입량을 효과적으로 결정해야 할 것으로 판단되었다.

상수도관의 물 흐름 방향을 고려한 공기주입 세척 및 단방향 플러싱 공법의 세척 효과 비교 연구 (Comparative study on cleaning effects of air scouring and unidirectional flushing considering water flow direction of water pipes)

  • 서지원;이규상;김기범;형진석;김태현;구자용
    • 상하수도학회지
    • /
    • 제33권5호
    • /
    • pp.353-366
    • /
    • 2019
  • This research proposes an optimal flushing operation technique in an effort to prevent secondary water pollutions and accidents in aged pipes, and to improve the cleaning effect of unidirectional flushing. Water flow directions were analyzed using EPANET 2.0, while flushing and air scouring experiments in forward and reverse directions were performed in the field. In 42 experiments, average residual chlorine concentration and turbidity were improved after cleaning compared to before cleaning. It was found that even when the same cleaning method was used, further improvement of cleaning effect was possible by applying air injection and reverse direction cleaning techniques. By means of one-way ANOVA(Analysis of variance), it was also possible to statistically verify the need of actively utilizing air injection and reverse direction cleaning. Based on correlation between turbidity and TSS, the total amount of suspended solids removal was estimated for 874 flushing operations and 194 air scouring operations. The result showed that air scouring used more discharge water than flushing by an average of $4.9m^3$ yet with larger amounts of suspended solids removal by an average of 145.9 g. The result of analysis on turbidity values from 887 flushing operations showed low cleaning effect of unidirectional flushing for the pipes with diameters over 300 mm. In addition, the turbidity values measured during cleaning showed an increasing tendency as pipe age increased. The methodology and results of this research are expected to contribute to the efficient maintenance and improvement of water quality in water distribution networks. Follow-up research involving the measurement of water quality at regular time intervals during cleaning would allow a more accurate comparison of discharge water quality characteristics and cleaning effects between different cleaning methods. To this end, it is considered necessary to develop a standardized manual that can be used in the field and to provide relevant trainings.

정적 오염 분석을 활용한 타입스크립트 코드의 보안 취약점 탐지 (Detecting Security Vulnerabilities in TypeScript Code with Static Taint Analysis)

  • 문태근;김형식
    • 정보보호학회논문지
    • /
    • 제31권2호
    • /
    • pp.263-277
    • /
    • 2021
  • 자바스크립트로 작성된 웹 어플리케이션에서 Cross-Site Scripting (XSS), SQL Injection과 같은 검증되지 않은 사용자 입력 데이터로 인해 발생하는 취약점을 탐지하기 위해 오염 분석 기법이 널리 사용되고 있다. 이러한 취약점을 탐지하기 위해서는 사용자 입력 데이터에 영향을 받는 변수들을 추적하는 것이 중요하지만, 자바스크립트의 동적인 특성으로 인해 웹 어플리케이션을 실행해 보지 않고 그러한 변수들을 식별하는 것은 매우 어렵다. 때문에, 기존의 오염 분석 도구들은 대상 어플리케이션을 실행하는 오버헤드가 존재하는 동적 오염 분석을 사용하도록 개발되었다. 본 논문에서는 타입스크립트(자바스크립트의 상위집합) 컴파일러를 활용해 얻은 심볼 정보를 기반으로 데이터의 흐름을 정확히 추적하고, 타입스크립트 코드에서 보안 취약점을 발견하는 새로운 정적 오염 분석 기법을 제안하였다. 제안한 기법은 개발자가 검증되지 않은 사용자 입력 데이터를 포함할 수 있는 변수에 표시를 할 수 있도록 하며, 이를 활용해 사용자 입력 값에 영향을 받는 변수와 데이터를 추적한다. 제안한 기법은 TypeScript 컴파일러에 원활히 통합될 수 있기 때문에, 별도의 도구로 작동하는 기존 분석 도구와 달리 개발자가 개발 과정에서 취약점을 발견할 수 있게 한다. 제안한 기법의 유효성을 확인하기 위해 프로토타입을 구현하였으며, 취약점이 보고된 8개의 웹 어플리케이션을 선정하여 분석을 수행하여 성능을 평가한 결과 기존의 취약점을 모두 탐지할 수 있음을 확인하였다.