• Title/Summary/Keyword: Flow Guide Unit

Search Result 18, Processing Time 0.023 seconds

Performance and Flow Characteristics of Axial Fan (축류팬의 성능 평가 및 주변 유동 특성)

  • 김재원;정윤영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.972-981
    • /
    • 2000
  • Comprehensive work is done for flows by an axial fan by experimental research. The present model fan is used for air handling device for out-door unit of an air conditioner in home appliance. PIV(Particle Image Velocimetry) system and wind tunnel are adopted for measurements of flows and performance evaluation, respectively. Major experimental conditions are the installation depth of a fan into a bellmouth of it. Optimal position of a fan in an inlet guide tube is observed by examination of fan-performance and flows in both upstream and downstream of the fan. Consequently, in the case of the fan inserted in half depth into the inlet tube, the efficiency of fan shows its maximum value and flow patterns is also streamlined.

  • PDF

Study on Separating Performance of Oscillating Sieve in Wet-Paddy Threshing (요동(搖動)체의 벼 생탈곡물(生脱糓物) 선별성능(選別性能)에 관(關)한 연구(硏究))

  • Kim, Sang Hun
    • Journal of Biosystems Engineering
    • /
    • v.7 no.1
    • /
    • pp.33-41
    • /
    • 1982
  • When wet-paddy is threshed by conventional auto-fed thresher, the threshed material under the concave is difficult to separate with pneumatic separation only. The development of thresher with an oscillating sieve in addition to the conventional pneumatic separation has been recommanded to improve the separation of grains from straw and chaff having high moisture content. This study was intended to evaluate the separating performance of an oscillating sieve and to obtain the effective operation conditions of the sieve separation. The sieve with oscillating in an elliptical motion was developed and installed in the experimental unit which can simulate the separating operation of the conventional auto-fed thresher. Results of the study are summarized as follows: 1. The flowing velocity of grains on oscillating sieve was increased as the sieve frequency increased but the feed rate did not significantly affect the flowing velocity of grains on sieve. 2. The effects of sieve frequency and the direction of sieve rotation on the separating performance by oscillating sieve show that increasing the frequency of sieve driving crank above the 460 rpm in the same direction of material flow (con-flow) improved the separating performance. 3. The height of grain guide plate and air velocity through the sieve to optimize the separating performance of oscillating sieve were experimentally determined to give about 10cm above the sieve and 7 m/s, respectively.

  • PDF

Mechanical Properties of Lightweight Foamed Concrete Using Polymer Foam Agent (고분자 기포제를 이용한 경량 기포 콘크리트의 역학적 특성 (II))

  • 박상순;송하원;변근주
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.1
    • /
    • pp.173-181
    • /
    • 1997
  • The objective of this study is to obtain the mechanical characteristics of prefoarmed lightweight foamed concrete using the polymer ham agent which has high lightness. flowability and strength. For this purpose, the prefoarmed lightweight foamed concrete which was developed to have flow value over 180mm. unit weight between 0.38t/$m^3$ and 0.64t/$m^3$, and compressive strength about 30kg/$cm^2$ was used. This paper presents extensive test data on Young's modulus. Poisson's ratio, stress-strain curve, the characteristics of strength of the foamed concrete and also presents the mechanical characteristics of the foamed concrete with different foam sizes. It is expected that this study provides an importance guide to design and manufacture lightweight foam concrete, so that it helps to expand its structural use.

Corona Discharge Characteristics and Particle Losses in a Unipolar Corona-needle Charger Obtained through Numerical and Experimental Studies

  • Intra, Panich;Yawootti, Artit;Rattanadecho, Phadungsak
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.2021-2030
    • /
    • 2017
  • In this paper, the unipolar corona-needle charger was developed and its capabilities were both numerically and experimentally investigated. The experimental corona discharges and particle losses in the charger were obtained at different corona voltage, aerosol flow rate and particle diameter for positive and negative coronas. Inside the charger, the electric field and charge distribution and the transport behavior of the charged particle were predicted by a numerical simulation. The experimental results yielded the highest ion number concentrations of about $1.087{\times}10^{15}ions/m^3$ for a positive corona voltage of about 3.2 kV, and $1.247{\times}10^{16}ions/m^3$ for a negative corona voltage of about 2.9 kV, and the highest $N_it$ product for positive and negative coronas was found to about $7.53{\times}10^{13}$ and $8.65{\times}10^{14}ions/m^3$ s was occurred at the positive and negative corona voltages of about 3.2 and 2.9 kV, respectively, and the flow rate of 0.3 L/min. The highest diffusion loss was found to occur at particles with diameter of 30 nm to be about 62.50 and 19.33 % for the aerosol flow rate of 0.3 and 1.5 L/min, respectively, and the highest electrostatic loss was found to occur at particles with diameters of 75 and 50 nm to be about 86.29 and 72.92 % for positive and negative corona voltages of about 2.9 and 2.5 kV, respectively. The numerical results for the electric field distribution and the charged particles migration inside the charger were used to guide the description of the electric field and the behavior of charged particle trajectories to improve the design and refinement of a unipolar corona-needle charger that otherwise could not be seen from the experimental data.

Design of Pressure Injury Management Mobile Application Structure and User Interface (욕창관리 모바일 어플리케이션 구조 설계 및 사용자 인터페이스 구현)

  • Lee, Jisan;Kim, Jungjae;Lee, Yun Jin;Park, Seungmi
    • Journal of muscle and joint health
    • /
    • v.26 no.3
    • /
    • pp.223-231
    • /
    • 2019
  • Purpose: This study aimed to design user interfaces of a mobile application for managing pressure injury patients in a long-term care hospital based on the user's needs. Methods: To reflect users' needs in the mobile application, the user interfaces in this study were designed in five steps: brainstorming and mind mapping, persona and scenario, needs list and priority, a draft version of flow chart and user interfaces and expert review. These steps were conducted with a step nurse at a long-term care hospital, a professor who majored in nursing informatics, a professor who had lots of research experiences about pressure injury and a wound ostomy continence nurse. Results: Two personas, scenarios and needs' lists were derived. Listed Needs included the followings; Accurate staging of pressure injury; Appropriate management by staging; Acquisition of professional knowledge about pressure injury; Acquisition of easy pressure injury information through text, picture and video; and Sharing pressure injury information in unit. The structure, menus and features of the pressure injury mobile application were visualized with user flow based on two personas' scenarios and needs' lists. Conclusion: Our study suggests and visualizes the key features of the 'Pressure Injury Guide', a pressure injury management mobile application for nurses in a long-term care hospital, which can be utilized by nurses, application developers, and related researchers.

A Study of the Spatial Composition of the Each Generation's Museum Space by Space Syntax Analysis - Focused on Connection Form Changes of the Major Space and Exhibition Space - (공간구문론(Space Syntax) 분석에 의한 세대별 박물관 공간구성에 관한 연구 - 대공간과 전시공간 연결방식의 변화양상을 중심으로 -)

  • Park, Chong-Ku;Lee, Sung-Hoon
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.247-254
    • /
    • 2006
  • The museum has steadily been evolved by time with its function and social idea differently. As the museum makes its evolution, its architecture has also been changed. This study aims to find out the characteristics of museum architecture by applying Space Syntax for space correspondence of museum architecture changed by the time. And the characteristics could be used as project guide by making data for building up museum architecture changed by social concept with efficient and functional system. The method of the study is to divide the museum into three generations, and give case for each generation. And the each chosen case was analyzed by convex space of space syntax. The order of the analysis is to divide the case as the unit space, make out the Convex Map. And finally get the analysis variable by carrying out a mathematical operation. The characteristics found in these operations are as follows. First, the major space has been planed for convenience of spectators. Second, exhibition space located on specific area in entire plot planning makes spectators easy to recognize in terms of the line of flow toward exhibition space and also relieves character of major and exhibition space. Third, it is getting hard to comprehend the entire space as forming diverse space in process that museum accepts many request from spectators.

A Numerical Study on an Optimum Design of a Hybrid Collector Coupled with the Principle of Cyclone, Baffle and Bag-Filter (싸이클론과 배플 및 백필터 원리를 결합한 하이브리드형 집진기의 최적화 설계를 위한 수치해석)

  • Hong, Sung-Gil;Jung, Yu-Jin;Lim, Ki-Hyuk;Yoo, Jeong-Kun;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.983-989
    • /
    • 2013
  • The current research reviewed the design conditions that would maximize the efficiency of the hybrid collector that combines in one unit "cyclone-inertial impaction-bag filter". The computational analysis for the shape of cyclone entry predicts that a design that installs the guide vane at the entry of the tangential type cyclone brings a high-rpm and powerful vortex, very effective in promoting the deflection of coarse particles from the streamline at the cyclone. As the lower part of the cyclone is venturi-shaped, however, a strong flow downward of 4 to 5 m/sec persists through the lower part of the hopper, revealing the likely reentrainment of collected dust. And the removal of the venturi at the lower part of the cyclone would solve the problem of the reentrainment of collected dust. The acceleration of the flow velocity through the adjustment of the gap of the collision baffle would increase the effect of collision, but as the interference with the dust separation is expected, the original design should be kept for the baffle.

Derivation of the Synthetic Unit Hydrograph Based on the Watershed Characteristics (유역특성에 의한 합성단위도의 유도에 관한 연구)

  • 서승덕
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.1
    • /
    • pp.3642-3654
    • /
    • 1975
  • The purpose of this thesis is to derive a unit hydrograph which may be applied to the ungaged watershed area from the relations between directly measurable unitgraph properties such as peak discharge(qp), time to peak discharge (Tp), and lag time (Lg) and watershed characteristics such as river length(L) from the given station to the upstream limits of the watershed area in km, river length from station to centroid of gravity of the watershed area in km (Lca), and main stream slope in meter per km (S). Other procedure based on routing a time-area diagram through catchment storage named Instantaneous Unit Hydrograph(IUH). Dimensionless unitgraph also analysed in brief. The basic data (1969 to 1973) used in these studies are 9 recording level gages and rating curves, 41 rain gages and pluviographs, and 40 observed unitgraphs through the 9 sub watersheds in Nak Oong River basin. The results summarized in these studies are as follows; 1. Time in hour from start of rise to peak rate (Tp) generally occured at the position of 0.3Tb (time base of hydrograph) with some indication of higher values for larger watershed. The base flow is comparelatively higher than the other small watershed area. 2. Te losses from rainfall were divided into initial loss and continuing loss. Initial loss may be defined as that portion of storm rainfall which is intercepted by vegetation, held in deppression storage or infiltrated at a high rate early in the storm and continuing loss is defined as the loss which continues at a constant rate throughout the duration of the storm after the initial loss has been satisfied. Tis continuing loss approximates the nearly constant rate of infiltration (${\Phi}$-index method). The loss rate from this analysis was estimated 50 Per cent to the rainfall excess approximately during the surface runoff occured. 3. Stream slope seems approximate, as is usual, to consider the mainstreamonly, not giving any specific consideration to tributary. It is desirable to develop a single measure of slope that is representative of the who1e stream. The mean slope of channel increment in 1 meter per 200 meters and 1 meter per 1400 meters were defined at Gazang and Jindong respectively. It is considered that the slopes are low slightly in the light of other river studies. Flood concentration rate might slightly be low in the Nak Dong river basin. 4. It found that the watershed lag (Lg, hrs) could be expressed by Lg=0.253 (L.Lca)0.4171 The product L.Lca is a measure of the size and shape of the watershed. For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the watershed characteristics, L and Lca. 5. Expression for basin might be expected to take form containing theslope as {{{{ { L}_{g }=0.545 {( { L. { L}_{ca } } over { SQRT {s} } ) }^{0.346 } }}}} For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the basin characteristics too. It should be needed to take care of analysis which relating to the mean slopes 6. Peak discharge per unit area of unitgraph for standard duration tr, ㎥/sec/$\textrm{km}^2$, was given by qp=10-0.52-0.0184Lg with a indication of lower values for watershed contrary to the higher lag time. For the logarithms, the correlation coefficient qp was 0.998 which defined high sign ificance. The peak discharge of the unitgraph for an area could therefore be expected to take the from Qp=qp. A(㎥/sec). 7. Using the unitgraph parameter Lg, the base length of the unitgraph, in days, was adopted as {{{{ {T}_{b } =0.73+2.073( { { L}_{g } } over {24 } )}}}} with high significant correlation coefficient, 0.92. The constant of the above equation are fixed by the procedure used to separate base flow from direct runoff. 8. The width W75 of the unitgraph at discharge equal to 75 per cent of the peak discharge, in hours and the width W50 at discharge equal to 50 Per cent of the peak discharge in hours, can be estimated from {{{{ { W}_{75 }= { 1.61} over { { q}_{b } ^{1.05 } } }}}} and {{{{ { W}_{50 }= { 2.5} over { { q}_{b } ^{1.05 } } }}}} respectively. This provides supplementary guide for sketching the unitgraph. 9. Above equations define the three factors necessary to construct the unitgraph for duration tr. For the duration tR, the lag is LgR=Lg+0.2(tR-tr) and this modified lag, LgRis used in qp and Tb It the tr happens to be equal to or close to tR, further assume qpR=qp. 10. Triangular hydrograph is a dimensionless unitgraph prepared from the 40 unitgraphs. The equation is shown as {{{{ { q}_{p } = { K.A.Q} over { { T}_{p } } }}}} or {{{{ { q}_{p } = { 0.21A.Q} over { { T}_{p } } }}}} The constant 0.21 is defined to Nak Dong River basin. 11. The base length of the time-area diagram for the IUH routing is {{{{C=0.9 {( { L. { L}_{ca } } over { SQRT { s} } ) }^{1/3 } }}}}. Correlation coefficient for C was 0.983 which defined a high significance. The base length of the T-AD was set to equal the time from the midpoint of rain fall excess to the point of contraflexure. The constant K, derived in this studies is K=8.32+0.0213 {{{{ { L} over { SQRT { s} } }}}} with correlation coefficient, 0.964. 12. In the light of the results analysed in these studies, average errors in the peak discharge of the Synthetic unitgraph, Triangular unitgraph, and IUH were estimated as 2.2, 7.7 and 6.4 per cent respectively to the peak of observed average unitgraph. Each ordinate of the Synthetic unitgraph was approached closely to the observed one.

  • PDF