• Title/Summary/Keyword: Flow Detection

Search Result 1,246, Processing Time 0.03 seconds

A study on the development of CW(Continuous-Wave) Doppler System using FFT (FFT를 이용한 연속초음파 도플러 장치에 관한 연구)

  • Lee, Dae-Hyung;Kang, Chung-Shin;Park, Sei-Hyun;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.709-712
    • /
    • 1988
  • Ultrasonic Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. CW(Continuous-Wave) Doppler System uses quadrature detection and phase rotation method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time-domain, had been fabricated. But time-domain analyzing such as audio evaluation and zero- crossing detection for instantaneous and mean frequnecy measurement do not provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency-domain technique to improve system performance. In this paper, we describe a unit which is composed of CW Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of Blood signal.

  • PDF

Transient Analysis and Experiment Considering Unsteady Friction and Leakage in a Pipeline System (단일관망에서 누수효과를 고려한 천이류 분석 및 실험)

  • Lee, Mi-hyun;Song, Yong-sok;Kim, Sang-hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.207-214
    • /
    • 2006
  • The current paper focuses the analysis of leakage detection in water pipeline systems by means of the transient method. In order to obtain essential data for evaluation the existing methodology, an extensive experimental process has been carried out in a single pipeline system, Several experimental tests were performed with and without a leakage in the system. Using the unsteady friction and improved unsteady friction factors gives reasonable match between the computed and measured results on the condition of the flow situations presented in the paper. The transient method attempts to estimate the leakage in water pipelines using observed pressure data collected during transient events on the system.

Anomaly Detection with C3D-based Optical Flow in CCTV (C3D 기반의 광학 흐름을 결합한 CCTV에서의 이상 탐지)

  • Park, SeulGi;Hong, MyungDuk;Jo, GeunSik
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2020.01a
    • /
    • pp.7-9
    • /
    • 2020
  • 기존 CCTV 비디오에서 딥러닝 기반의 이상 탐지 연구는 객체의 행동 값만을 이용하여 이상을 탐지하였기 때문에, 시간 흐름에 따른 정보가 축소되는 문제점이 있었다. 그러나 CCTV 비디오에서의 이상의 원인은 다양한 요소와 시계열 분석에 따른 정보로 이루어져 있어 시간 정보를 유지하면서 다양한 특징 값을 사용한 모델을 설계할 필요가 있다. 따라서 본 논문에서는 C3D에 광학 흐름을 결합한 새로운 앙상블 모델을 제안한다. 실험 결과 본 논문에서 제안하는 모델이 75.83의 AUC를 얻어 기존에 연구되었던 행동 값만을 사용한 모델보다 높은 정확도를 달성하였다. 또한 이상 탐지 모델 설계 시 객체의 행동에 다양한 측면을 고려할 수 있는 여러 특징 값과 시계열 분석에 따른 정보를 사용하는 것이 적절하다는 결론을 도출하였다.

  • PDF

Research on Normalizing Flow-Based Time Series Anomaly Detection System (정규화 흐름 기반 시계열 이상 탐지 시스템 연구)

  • Younghoon Jeon;Jeonghwan Gwak
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.07a
    • /
    • pp.283-285
    • /
    • 2023
  • 이상 탐지는 데이터에서 일반적인 범주에서 크게 벗어나는 인스턴스 또는 패턴을 식별하는 중요한 작업이다. 본 연구에서는 시계열 데이터의 특징 추출을 위한 비지도 학습 기반 방법과 정규화 흐름의 결합을 통한 이상 탐지 프레임워크를 제안한다. 특징 추출기는 1차원 합성곱 신경망 기반의 오토인코더로 구성되며, 정상적인 시퀀스로만 구성된 훈련 데이터를 압축하고 복원하는 과정을 통해 최적화된다. 추출된 시계열 데이터의 특징 맵은 가능도를 최대화하도록 훈련된 정규화 흐름의 입력으로 사용된다. 이와 같은 방식으로 훈련된 이상 탐지 시스템은 테스트 샘플에 대한 이상치를 계산하며, 최종적으로 임계값과의 비교를 통해 이상 여부를 예측한다. 성능 평가를 위해 시계열 이상 탐지를 위한 공개 데이터셋을 이용하여 공정하게 이상 탐지 성능을 비교하였으며, 실험 결과는 제안하는 정규화 흐름 기법이 시계열 이상 탐지 시스템에 활용될수 있는 잠재성을 시사한다.

  • PDF

False Alarm Filtering Algorithm Development of Pipeline Leak Detection System using Flow Volume Balance (유량 밸런스 특성을 활용한 송유관 누유 감지 시스템의 오알람 필터링 알고리즘 개발)

  • Kim, Min-Sung;Kim, Hie-Sik;Jung, Hae-Kyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.95-102
    • /
    • 2016
  • Pipeline is making the most use of transportation of petroleum products on the land. But due to tremendous accident or environmental disaster by oil pipeline leak or pipeline stolen, leak detection systems have been used for preventing it. Leak detection method based on negative pressure wave has been used at the long distance pipeline. But even if it has showed good leak detection quality, due to making a lot of false alarm, it has weak point that disturbs concentration to system. This study suggests algorithm and method of using volume balance to decrease false-alarm of pipeline leak detection system based on negative pressure wave.

Real time Omni-directional Object Detection Using Background Subtraction of Fisheye Image (어안 이미지의 배경 제거 기법을 이용한 실시간 전방향 장애물 감지)

  • Choi, Yun-Won;Kwon, Kee-Koo;Kim, Jong-Hyo;Na, Kyung-Jin;Lee, Suk-Gyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.8
    • /
    • pp.766-772
    • /
    • 2015
  • This paper proposes an object detection method based on motion estimation using background subtraction in the fisheye images obtained through omni-directional camera mounted on the vehicle. Recently, most of the vehicles installed with rear camera as a standard option, as well as various camera systems for safety. However, differently from the conventional object detection using the image obtained from the camera, the embedded system installed in the vehicle is difficult to apply a complicated algorithm because of its inherent low processing performance. In general, the embedded system needs system-dependent algorithm because it has lower processing performance than the computer. In this paper, the location of object is estimated from the information of object's motion obtained by applying a background subtraction method which compares the previous frames with the current ones. The real-time detection performance of the proposed method for object detection is verified experimentally on embedded board by comparing the proposed algorithm with the object detection based on LKOF (Lucas-Kanade optical flow).

Localisation of embedded water drop in glass composite using THz spectroscopy

  • Mieloszyk, Magdalena;Majewska, Katarzyna;Ostachowicz, Wieslaw
    • Smart Structures and Systems
    • /
    • v.21 no.6
    • /
    • pp.751-759
    • /
    • 2018
  • Glass fibre reinforced polymers (GFRP) are widely exploited in many industrial branches. Due to this Structural Health Monitoring systems containing embedded fibre optics sensors are applied. One of the problems that can influence on composite element durability is water contamination that can be introduced into material structure during manufacturing. Such inclusion can be a damage origin significantly decreasing mechanical properties of an element. A non-destructive method that can be applied for inspection of an internal structure of elements is THz spectroscopy. It can be used for identifications of material discontinuities that results in changes of absorption, refractive index or scattering of propagating THz waves. The limitations of THz propagation through water makes this technique a promising solution for detection of a water inclusion. The paper presents an application of THz spectroscopy for detection and localisation of a water drop inclusion embedded in a GFRP material between two fibre optics with fibre Bragg grating sensors. The proposed filtering method allowed to determine a 3D shape of the water drop.

On-line Monitoring of Glucose and Acetate by Flow-Injection Analysis in Escherichia coli Fermentation Process (대장균 발효공정에서 흐름주입분석을 이용한 글루코스와 초산의 온라인 모니터링)

  • 이종일
    • KSBB Journal
    • /
    • v.13 no.3
    • /
    • pp.244-250
    • /
    • 1998
  • Flow-injection analysis (FIA) for on-line monitoring of glucose and acetate are described and employed in E.coli fermentation process. Glucose oxidase (GOD) for the detection of glucose is immobilized on epoxy polymer support, which is packed in a small cartirdge, and applied to a GOD-FIA system. The detection of acetate is based on the inhibition of acetate to the oxidation of sarcosine by sarcosine oxidase (SOD). SOD is also immobilized on epoxy polymer support and used for a SOD-FIA system. GOD-FIA system is characterized as well as SOD-FIA system by the investigation of the effects of pH, temperature and metabolites in samples on the peak height. GOD-FIA and SOD-FIA systems were also applied for on-line On-line measurements buy FIA measurements by FIA were in god agreement with off-line measurements.

  • PDF

Design of Intelligent Servocontroller for Proportional Flow Control Solenoid Valve with Large Capacity (지능형 대용량 비례유량제어밸브 서보컨트롤러 설계)

  • Jung, G.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.3
    • /
    • pp.1-7
    • /
    • 2011
  • As the technologies of electronic device have advanced these days, most of mechanical systems are designed with electronic control unit to take advantage of control parameter adaption to operating conditions and firmware flexibilities as well. On-board diagnosis, which detects the system malfunction and identifies potential source of error with its own diagnostic criteria, and fail-safe that can switch the mode of operation in view of recognized error characteristics enables easy maintenance and troubleshooting as well as system protection. This paper dealt with the development of diagnosis and fail-safe function for proportional flow control valve. All type of errors related to valve control system components are investigated and assigned to a specific hexadecimal codes. Cumulative error detection algorithm is applied in order for the sensitivity and reliability to be appropriate. Embedded simulator which runs simultaneously with system program provides the virtual error simulation environment for expeditious development of error detection algorithm. The diagnosis function was verified both with solenoid valve and embedded simulator test and it will enhance the valve control system monitoring function.

A Sensitive Procedure for the Rapid Determination of Mandelic Acid by Flow Injection Analysis and Chemiluminescence Detection

  • Alam, Seikh Mafiz;Jeon, Chi-Wan;Karim, Mohammad Mainul;Lee, Sang-Hak;Wabaidur, Saikh Mohammad;Suh, Yeoun-Suk;Chung, Hye-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.102-106
    • /
    • 2009
  • A rapid and sensitive chemiluminescence (CL) method using flow-injection (FI) has been developed for the determination of mandelic acid which is based on the enhancement of mandelic acid to the CL intensity of ${Ru(bipy)_{3}}^{2+}$-Ce(IV) system. The enhancement effect was dependent on the concentration of mandelic acid, based on which, CL system was established for the determination of mandelic acid. The concentrations of ${Ru(bipy)_{3}}^{2+}$+, Ce(IV), and $H_2SO_4$ were optimized. Under the optimum experimental conditions, the linear range and detection limit are 1.46-342.0 ${\mu}g/ml$ and 0.072 ${\mu}g/ml$, respectively. The correlation coefficient (R) was 0.99732. The utility of this method was demonstrated by determining mandelic acid in capsules and human urine sample.